• 제목/요약/키워드: Impact Collapse Experiment

검색결과 14건 처리시간 0.017초

해수 환경에서 슈퍼 오스테나이트 스테인리스강의 전기화학적 거동에 미치는 캐비테이션 진폭의 영향 (Effect of Cavitation Amplitude on the Electrochemical Behavior of Super Austenitic Stainless Steels in Seawater Environment)

  • 허호성;김성종
    • Corrosion Science and Technology
    • /
    • 제21권2호
    • /
    • pp.138-146
    • /
    • 2022
  • The cavitation and potentiodynamic polarization experiments were conducted simultaneously to investigate the effect of cavitation amplitude on the super austenitic stainless steel (UNS N08367) electrochemical behavior in seawater. The results of the potentiodynamic polarization experiment under cavitation condition showed that the corrosion current density increased with cavitation amplitude increase. Above oxygen evolution potential, the current density in a static condition was the largest because the anodic dissolution reaction by intergranular corrosion was promoted. In the static condition, intergranular corrosion was mainly observed. However, damage caused by erosion was observed in the cavitation environment. The micro-jet generated by cavity collapse destroyed the corrosion product and promoted the repassivation. So, weight loss occurred the most in static conditions. After the experiment, wave patterns were formed on the surface due to the compressive residual stress caused by the impact pressure of the cavity. Surface hardness was improved by the water cavitation peening effect, and the hardness value was the highest at 30 ㎛ amplitude. UNS N08367 with excellent mechanical performance due to its high hardness showed that cavitation inhibited corrosion damage.

외부 정수압을 받는 복수 원통의 연쇄 내파에 관한 실험연구 (Tests on the Serial Implosion of Multiple Cylinders Subjected to External Hydrostatic Pressure)

  • 태구무타퀴;박상현;손정민;조상래;노인식;이필승;조윤식
    • 대한조선학회논문집
    • /
    • 제57권4호
    • /
    • pp.213-220
    • /
    • 2020
  • In the present paper, implosion responses of two adjacent cylindrical tubes under external hydrostatic pressure were experimentally investigated. The cylinder models were fabricated of aluminium alloy 6061-T6 commercial tubes. In the experiment, a pair of two-cylinders were placed inside of a support frame in a medium-size pressure chamber, whose design pressure was 6.0MPa. The distance between the two-cylinders was 30 millimeter measured from outer shell at the mid-length. The implosion tests were performed with water and compressed nitrogen gas as the pressurizing media. The ambient static pressure of the chamber and local dynamic pressure near the two-imploded models were measured simultaneously. It was found that the energy released during an implosion from the first, weaker cylinder triggered the instability of the second, stronger cylinders. In other words, the resulting shock wave of the first implosive impact from the weaker cylinder could cause the premature failure of the neighboring stronger cylinders. The non-contact implosion phenomena from the two-cylindrical tube were clearly observed.

단면의 형상에 따른 철근콘크리트 기둥의 폭발저항 성능 평가 (An Evaluation of Blast Resistance Performance of RC Columns According to the Shape of Cross Section)

  • 김한수;박재표
    • 한국전산구조공학회논문집
    • /
    • 제23권4호
    • /
    • pp.387-394
    • /
    • 2010
  • 현재 연쇄붕괴를 방지하기 위한 설계 방법으로 기둥제거 시나리오를 이용한 대체하중경로법을 주로 적용하고 있다. 하지만 실제로 폭발이 발생하여 기둥이 완전히 제거되지 않는 경우에 기둥제거 시나리오를 적용하면 보수적인 결과를 얻게 된다. 본 논문에서는 단일 기둥이 폭발하중을 받을 때의 거동을 평가함으로써 폭발이후에도 기둥이 연쇄붕괴 방지에 기여할 수 있는지 여부를 판단하였다. 하이드로코드인 AUTODYN을 이용하였으며, 같은 단면적과 높이를 갖는 사각형 기둥과 원형 기둥의 폭발저항성능을 비교하였다. 우선 AUTODYN을 이용한 폭발하중 산정 결과를 폭발실험값과 비교한 다음 간단한 폭발 예제를 통해 계산된 폭발압력파가 실제와 유사함을 입증하였다. 단면 형상에 따른 기둥의 폭발저항 성능 해석을 수행한 후 잔류변형을 이용한 평가법을 이용해 원형기둥이 사각형 기둥보다 폭발저항 성능이 더 우수함을 확인하였다.

광주광역시 광산구 소재 초등학교 라돈가스 농도 계측 (Elementary School in Gwangju Gwangsan Radon gas Density Measurement)

  • 안병주;오지훈
    • 한국방사선학회논문지
    • /
    • 제8권4호
    • /
    • pp.211-216
    • /
    • 2014
  • 자연방사선 물질인 라돈($^{222}Rn$)은 암석이나 토양 또는 건축자재 중에 들어있는 우라늄($^{238}U$)이 몇 단계의 방사성 붕괴 과정을 거친 후 생성되는 무색무취의 불활성기체로 지하 근무지나 밀폐된 공간과 같은 곳에서 잘 축적된다. 호흡기를 통하여 허파로 유입되고 라돈의 딸핵종이 허파나 기관지에 침적되어 폐암을 일으키는 원인이 된다. 본 연구에서는 초등학교 교실내의 공기 중 라돈가스농도을 비교하였으며 계측된 값을 이용하여 연간내부피폭량을 계산하였다. 초등학교 교실에서 측정된 라돈가스 피폭은 최소 5개교에서 층별 평균치가 창문을 닫을 때의 경우 1층 0.56mSv, 2층 0.48mSv, 3층 0.384mSv의 평균치가 나왔으며, 창문을 열었을 때의 경우 1층과 2층은 0.31mSv 수치로 같고 3층은 0.296mSv로평균치가 나왔다. 라돈에 대한 인체 피폭은 1층에서 피폭이 많고 3층에서는 피폭이 적었다. 창문을 닫았을 때의 경우 최대 0.56mSv 최소 0.384mSv로 자연방사선에 의한 연간피폭량에 2.4mSv 16%에서 23.3%를 차지하고 있다. 창문을 열었을 때의 경우 최대 0.31mSv 최소 0.296mSv로 연간피폭량 2.4mSv의 12.3%에서 12.91%를 차지한다. 결과로 보아 라돈가스 계측을 실시한 5개 초등학교의 경우 국내의 라돈기준치 이하로 나왔으며 내부피폭 역시 정상범위 내에 속한다. 사람에게 있어서 방사선피폭이 적으면 적을수록 인체에 대한 영향이 줄어들기 때문에 초등학교 교실 내에서 창문을 자주 환기한다면 즉, 공기 중 라돈농도를 최대한 줄인다면 라돈가스에 대한 피폭량을 줄일 수 있을 것이며 면역력이 약한 초등학생에게 도움이 될 것이다. 실험에 있어서 향후 더 많은 초등학교 기관에 대해 라돈가스 조사가 이루어지고 그에 따른 조치를 행한다면 보다 더 안전한 초등학교 건물시설 확립에 도움이 될 것이라 생각된다.