• Title/Summary/Keyword: Immunochromatography assay

Search Result 11, Processing Time 0.03 seconds

Chemiluminescence immunochromatographic analysis for the quantitative determination of algal toxins

  • Pyo, Dongjin;Kim, Taehoon
    • ALGAE
    • /
    • v.28 no.3
    • /
    • pp.289-296
    • /
    • 2013
  • For the quantitative detection of algal toxin, microcystin, a chemiluminescence immunochromatographic assay method was developed. The developed system consists of four parts, chemiluminescence assay strip (nitrocellulose membrane), horse radish peroxidase labeled microcystin monoclonal antibodies, chemiluminescence substrate (luminol and hydrogen peroxide), and luminometer. The performance of the chemiluminescence immunochromatographic assay system was compared with high performance liquid chromatography (HPLC) detection. The detection limit of chemiluminescence immunochromatographic assay system is several orders of magnitude lower than with HPLC. The chemiluminescence immunochromatography and HPLC results correlated very well with the correlation coefficient ($r^2$) of 0.979.

Microcystin Detection Characteristics of Fluorescence Immunochromatography and High Performance Liquid Chromatography

  • Pyo, Dong-Jin;Park, Geun-Young;Choi, Jong-Chon;Oh, Chang-Suk
    • Bulletin of the Korean Chemical Society
    • /
    • v.26 no.2
    • /
    • pp.268-272
    • /
    • 2005
  • Different detection characteristics of fluorescence immunochromatography method and high performance liquid chromatography (HPLC) method for the analysis of cyanobacterial toxins were studied. In particular, low and high limits of detection, detection time and reproducibility and detectable microcystin species were compared when fluorescence immunochromatography method and high performance liquid chromatography method were applied for the detection of microcystin (MC), a cyclic peptide toxin of the freshwater cyanobacterium Microcystis aeruginosa. A Fluorescence immunochromatography assay system has the unique advantages of short detection time and low detection limit, and high performance liquid chromatography detection method has the strong advantage of individual quantifications of several species of microcystins.

Enzyme-linked Immunosorbent Assays (ELISA) and Immunochromatography Assays (ICG) for Analysis of Vitellogenin in the Scorpion Fish Sebastiscus marmoratus (쏨뱅이(Sebastiscus marmoratus)의 Vitellogenin 분석을 위한 효소면역측정법(ELISA) 및 면역크로마토그래피분석법(ICG) 개발)

  • Yeo, In-Kyu;Lim, Yoon-Kyu
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.48 no.4
    • /
    • pp.459-465
    • /
    • 2015
  • We tested biomarker systems [enzyme-linked immunosorbent assay (ELISA) and immunochromatography assay (ICG) kits] for the screening of endocrine-disrupting chemicals in contaminated environments using antibodies resulting from $17{\beta}$-Estradiol-induced vitellogenin (Vtg) in the wild scorpion fish Sebastiscus marmoratus. Monoclonal antibodies of two clones (S28 and S15) were used as capture and tracer antibodies for ELISA and ICG assays. ELISA detected Vtg at levels greater than $0.1{\mu}g/mL$, while ICG detected Vtg at levels greater than $1{\mu}g/mL$. However, the ICG system was able to detect antibodies from $17{\beta}$-Estradiol-induced Vtg serum that had been diluted 1,000 times. Our results suggest that previously developed biomarker assays can be used as detection systems to detect known endocrine-disrupting chemicals in contaminated environments, and to measure their activity.

Comparison of chemiluminescence immunoassay (CIA) and immunochromatography assay(ICA) for Detecting HBsAg and Anti-HBs (B형 간염항원 및 항체 검사를 위한 화학발광면역검사법(CIA)과 면역크로마토그래피법(ICA)의 비교분석)

  • Kim, Hye-Jeong;Kim, Eun-Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.7
    • /
    • pp.3419-3424
    • /
    • 2013
  • Diverse immunoassays including a chemiluminescent immunoassay (CIA) are used to detect hepatitis B surface antigen (HBsAg) and antibody (anti-HBs). Recently, an increasing number of institutions have been utilizing an immunochromatography assay (ICA), which is easy to use. In this study, We evaluated ICA kits for the rapid detection of HBsAg and anti-HBs by comparing them with a CIA. A total of 120 serum hospital samples, were collected for the whole month, were assayed using ICA kit. The Concordance rate, sensitivity, specificity, positive predictive value and negative predictive value of the ICA for HBsAg based on CIA results were 97%, 97%, 100%, 100%, and 96.8%, respectively. The diagnostic performances of the ICA for Anti-HBs were 90%, 90%, 93.3%, 93.1%, and 90.3%, respectively. The ICA kit failed to detect HBsAg and anti-HBs in low reactive samples. The ICA kits for the rapid detection of HBsAg might be recommended for interpreted with caution and dual analysis in the clinical laboratory.

Development of Novel Method for the Detection of Microcystin Using Chemiluminescence Immunochromatography

  • Pyo, Dong-Jin;Yoo, Ji-Sun
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.1
    • /
    • pp.149-152
    • /
    • 2011
  • A new chemiluminescence immunochromatographic analysis system with high sensitivity and high reproducibility was developed for the determination of microcystins (MCs) in water. Horse radish peroxidase (HRP) labeled microcystin monoclonal antibody was used for the sensitive chemiluminescence detection. The chemiluminescence immunochromatographic analysis system was composed of microcystin LR (MCLR)-monoclonal antibody (mAb)-Horse Radish Peroxidase (HRP) conjugate, MCLR-BSA conjugate, luminol, hydrogen peroxide mixture solution, an immunochromatographic assay strip and luminometer. To detect the concentration of microcystins in water, we utilized one spot analysis of the strip instead of flow type analysis. We could detect the microcystins in water at a concentration as low as 9.45 pg/mL with the chemiluminescence (CL) detection.

A rapid and quantitative fluorescent microsphere immunochromatographic strip test for detection of antibodies to porcine reproductive and respiratory syndrome virus

  • Wei, Yanqiu;Yang, Baozhi;Li, Yunlong;Duan, Yongcheng;Tian, Deyu;He, Baoxiang;Chen, Chuangfu;Liu, Wenjun;Yang, Limin
    • Journal of Veterinary Science
    • /
    • v.21 no.4
    • /
    • pp.68.1-68.8
    • /
    • 2020
  • A fluorescent microsphere-based immunochromatographic strip test (FICT) was developed for the rapid, sensitive, and quantitative detection of porcine reproductive and respiratory syndrome virus (PRRSV) antibodies at the pen-side. The assay was based on the formation of a sandwich immune-complex (anti-pig IgG-PRRSV antibodies-NSP7/N), which was validated by a comparison with IDEXX-ELISA using 3325 clinical specimens. The diagnostic specificity, sensitivity, and accuracy of FICT were 97.28, 93.41, and 94.95%, respectively. FICT showed a good correlation with the virus neutralization assay. Overall, a promising pen-side diagnostic tool was developed for the rapid and quantitative detection of PRRSV antibodies within 15 min.

One-Step Simultaneous Immunochromatographic Strip Test for Multianalysis of Ochratoxin A and Zearalenone

  • Shim, Won-Bo;Dzantiev, Boris B.;Eremin, Sergei A.;Chung, Duck-Hwa
    • Journal of Microbiology and Biotechnology
    • /
    • v.19 no.1
    • /
    • pp.83-92
    • /
    • 2009
  • Individual immunochromatographic assays (ICG) for ochratoxin A (OTA) and zearalenone (ZEA) were optimized and used in the development of a one-step simultaneous immunochromatographic assay (OS-ICG) for the rapid multianalysis of two mycotoxins in corn samples. The nitrocellulose membrane of the OS-ICG was treated with OTA-bovine serum albumin (BSA), ZEA-ovalbumin (OVA), and anti-mouse IgG in the OTA test, ZEA test, and control zones, respectively. Monoclonal antibody-gold conjugates (OTA3 MAb-gold and ZEA2C5 MAb-gold) were sprayed onto the conjugate pad. The visual detection limits were 2.5 and 5 ng/ml for OTA and ZEA, respectively, and the results were obtained within 15 min after starting the analysis. An efficient, simple, and rapid extraction method using 30% MeOH/PBS was established and validated by analyzing the corn samples spiked with OTA/ZEA mixtures (0/0, 5/10, 10/20, and $20/30\;{\mu}g/kg$). The cut-off values of the OS-ICG for the spiked corn were 5 and $10\;{\mu}g/kg$ for OTA and ZEA, respectively. Natural corn samples were analyzed by OS-ICG, direct competitive enzyme-linked immunosorbent assay (DC-ELISA), and HPLC. Results of the OS-ICG were in good agreement with those obtained by DC-ELISA and HPLC. The developed OS-ICG offers a rapid, easy-to-use, and portable analytical system and can be used as a convenient qualitative tool for the on-site simultaneous determination of OTA and ZEA in cereals, food, and agricultural products in one analytical cycle.

Development of Immunochromatography for Detection of Escherichia coli O157:H7 Contaminated in Meats and Sprouts (육류 및 새싹채소에 오염된 Escherichia coli O157:H7의 신속검출을 위한 면역크로마토그래피법의 개발)

  • Lee, Won-Gyeong;Ryu, Hee-Jeong;Song, Jeong-Un;Kim, Kyeong-Yeol;Chung, Do-Yeong;Kim, Jeong-Sook;Shim, Won-Bo;Chung, Duck-Hwa
    • Korean Journal of Food Science and Technology
    • /
    • v.43 no.5
    • /
    • pp.618-623
    • /
    • 2011
  • Escherichia coli O157:H7 has been considered as a significant food-borne pathogen since its role in causing hemorrhagic colitis and hemolytic uremic syndrome in humans was recognized. In this study, we developed an immunochromatography (ICG) assay for the detection of E. coli O157:H7. E. coli O157:H7 monoclonal antibody (EC MAb) and colloidal gold were conjugated and its specificity was determined by the ICG treated with EC MAb and antimouse IgG at test and control lines, respectively. The detection limit of the ICG was $1{\times}10^5$ CFU/mL, and no crossreactivity was observed to other E. coli strains and major food-borne pathogens. To determine the minimum enrichment time for the ICG, meats and sprouts were inoculated with $1{\times}10$ CFU/100 ${\mu}L$ of E. coli O157:H7. After enrichment time of 10 and 2 h for meats and sprouts, respectively, up to $1{\times}10$ CFU/100 ${\mu}L$ of E. coli O157:H7 could be detected by ICG.

Sero-positivity and Recognition of Anti-HAV and Anti-HBs in a University of Gumi city

  • Ko, Eun-Eip;Jo, Seon-Min;Kim, Keum-Hwa;Kim, Hyun-Ji;Jin, Cho-Rong;Kim, Hye-Jeong
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.44 no.4
    • /
    • pp.210-215
    • /
    • 2012
  • Hepatitis virus infection is one of the major problems in Korea. To establish preventive measures for hepatitis A and B virus infection, study on sero-positivity of serum anti-HAV (aHAV) and anti-HBs (aHBs) is needed. The aim of this study was to analyze the sero-positivity and related factors of aHAV and aHBs. We analysed the sero-positivity of serum aHAV and aHBs using ICA (Immunochromatography Assay) method from 102 university students and employees and questionnaire survey was obtained characteristics, vaccination history, past history test, knowledge and information sources of the study subjects. Overall sero-positivity rates of serum aHAV and aHBs were 20.6% and 52.9%, respectively. The sero-positivity rate of aHBs was significantly different by gender (M, 34.9%; F,66.1%) and that of aHAV was significantly different by age (20 age group, 2.7%; 30 age group, 14.3%; 40 age group, 70%; 50 age group, 91.7%). Overall sero-positivity rates of serum aHAV and aHBs by vaccination history rates were 4.9% and 43.1%, respectively. Overall sero-positivity rates of serum aHAV and aHBs by past history test were 10.8% and 52.9%, respectively. Sero-positivity rates of serum aHAV was low in university students. The results of this study could be used effectively as a basic data for establishing effective preventive measures for hepatitis A including vaccination.

  • PDF

Rapid Detection of Infectious Bursal Disease Virus (IBDV) in Chickens by an Immunochromatographic Assay Kit

  • Choi, Kang-Seuk;Oh, Jin-Sik;Jeon, Woo-Jin;Na, Keon-Sok;Lee, Eun-Kyoung;Lee, Youn-Jeong;Sung, Hwan-Woo;Ha, Gun-Woo;Kwon, Jun-Hun
    • Korean Journal of Poultry Science
    • /
    • v.37 no.2
    • /
    • pp.167-172
    • /
    • 2010
  • An immunochromatograhy (IC) based infectious bursal disease virus (IBDV) detection kit, which employed two anti-IBDV VP2 monoclonal antibodies, was evaluated for rapid diagnosis of infectious bursal disease virus (IBD). The detection limit of the IC kit for IBDV was $10^{3.1}$ to $10^{3.9}$ $EID_{50}$/mL, indicating that the IC kit detected IBDV sensitively as same as double antigen capture ELISA but less than a RT-PCR assay. The IC kit did not detect other viral pathogens such as Newcastle disease virus, infectious bronchitis, avian influenza virus, and infectious larynotracheitis virus. When applied to tissue samples of experimental chickens died 3 or 4 days post infection after very virulent IBDV (strain Kr/D62) infection, the IC kit detected IBDV in all samples of the bursa of Fabricius, spleen, kidney, cecal tonsil and in 87.5%, 37.5% and 0% of liver, thymus and proventriculus samples. In particular, BF tissue samples showed stronger signal bands than other tissues. Positive signal was observed. All except for one thymus sample of samples having negative results by the IC kit showed the same result with DAS-ELISA but RT-PCR assay detected IBDV in some of IC kit negative samples of thymus and proventriculus. When swab samples from the bursa of Fabricius of dead chickens (n=231) on field farms were tested, the sensitivity and specificity of the IC assay relative to RT-PCR was 100% (109/109) and 97.5% (119/122), respectively and kappa value between both assay was 0.97. The kit can provide a useful aid for rapid detection of IBDV in chickens under field circumstances.