• 제목/요약/키워드: Immunochromatography assay

검색결과 11건 처리시간 0.023초

Chemiluminescence immunochromatographic analysis for the quantitative determination of algal toxins

  • Pyo, Dongjin;Kim, Taehoon
    • ALGAE
    • /
    • 제28권3호
    • /
    • pp.289-296
    • /
    • 2013
  • For the quantitative detection of algal toxin, microcystin, a chemiluminescence immunochromatographic assay method was developed. The developed system consists of four parts, chemiluminescence assay strip (nitrocellulose membrane), horse radish peroxidase labeled microcystin monoclonal antibodies, chemiluminescence substrate (luminol and hydrogen peroxide), and luminometer. The performance of the chemiluminescence immunochromatographic assay system was compared with high performance liquid chromatography (HPLC) detection. The detection limit of chemiluminescence immunochromatographic assay system is several orders of magnitude lower than with HPLC. The chemiluminescence immunochromatography and HPLC results correlated very well with the correlation coefficient ($r^2$) of 0.979.

Microcystin Detection Characteristics of Fluorescence Immunochromatography and High Performance Liquid Chromatography

  • Pyo, Dong-Jin;Park, Geun-Young;Choi, Jong-Chon;Oh, Chang-Suk
    • Bulletin of the Korean Chemical Society
    • /
    • 제26권2호
    • /
    • pp.268-272
    • /
    • 2005
  • Different detection characteristics of fluorescence immunochromatography method and high performance liquid chromatography (HPLC) method for the analysis of cyanobacterial toxins were studied. In particular, low and high limits of detection, detection time and reproducibility and detectable microcystin species were compared when fluorescence immunochromatography method and high performance liquid chromatography method were applied for the detection of microcystin (MC), a cyclic peptide toxin of the freshwater cyanobacterium Microcystis aeruginosa. A Fluorescence immunochromatography assay system has the unique advantages of short detection time and low detection limit, and high performance liquid chromatography detection method has the strong advantage of individual quantifications of several species of microcystins.

쏨뱅이(Sebastiscus marmoratus)의 Vitellogenin 분석을 위한 효소면역측정법(ELISA) 및 면역크로마토그래피분석법(ICG) 개발 (Enzyme-linked Immunosorbent Assays (ELISA) and Immunochromatography Assays (ICG) for Analysis of Vitellogenin in the Scorpion Fish Sebastiscus marmoratus)

  • 여인규;임윤규
    • 한국수산과학회지
    • /
    • 제48권4호
    • /
    • pp.459-465
    • /
    • 2015
  • We tested biomarker systems [enzyme-linked immunosorbent assay (ELISA) and immunochromatography assay (ICG) kits] for the screening of endocrine-disrupting chemicals in contaminated environments using antibodies resulting from $17{\beta}$-Estradiol-induced vitellogenin (Vtg) in the wild scorpion fish Sebastiscus marmoratus. Monoclonal antibodies of two clones (S28 and S15) were used as capture and tracer antibodies for ELISA and ICG assays. ELISA detected Vtg at levels greater than $0.1{\mu}g/mL$, while ICG detected Vtg at levels greater than $1{\mu}g/mL$. However, the ICG system was able to detect antibodies from $17{\beta}$-Estradiol-induced Vtg serum that had been diluted 1,000 times. Our results suggest that previously developed biomarker assays can be used as detection systems to detect known endocrine-disrupting chemicals in contaminated environments, and to measure their activity.

B형 간염항원 및 항체 검사를 위한 화학발광면역검사법(CIA)과 면역크로마토그래피법(ICA)의 비교분석 (Comparison of chemiluminescence immunoassay (CIA) and immunochromatography assay(ICA) for Detecting HBsAg and Anti-HBs)

  • 김혜정;김은희
    • 한국산학기술학회논문지
    • /
    • 제14권7호
    • /
    • pp.3419-3424
    • /
    • 2013
  • B형간염표면 항원 및 항체(HBsAg와 anti-HBs)에 대한 검사 방법으로 화학발광면역검사법(CIA)을 포함한 면역검사법을 주로 사용하고 있으나 최근 간편한 면역크로마토그래피법(ICA)의 사용이 늘고 있는 추세이다. 본 연구에서는 CIA법을 이용한 정량검사법과 비교하여 신속검사인 ICA법의 민감도를 평가하고자 하였다. 대학병원에 간염검사를 의뢰한 검체 중 CIA법에서 양성 및 음성으로 나온 120 검체를 선정하여 ICA법으로 분석하였다. ICA법과 CIA법의 일치율은 항원 97%와 항체 90%로 나타났다. 항원검사의 ICA법 민감도, 특이도, 양성예측도, 음성예측도는 각각 97%, 100%, 100% 및 96.8%로 나타났으며, 항체검사는 각각 90%, 93.3%, 93.1% 및 90.3%로 나타났다. ICA법을 임상에서 사용 시 결과판독에 주의가 필요하며, 낮은 역가의 경우 검출되지 않는 제한점이 있으므로 예민도가 높은 다른 검사법을 이용하여 이중검사를 시행해야 할 것으로 사료된다.

Development of Novel Method for the Detection of Microcystin Using Chemiluminescence Immunochromatography

  • Pyo, Dong-Jin;Yoo, Ji-Sun
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권1호
    • /
    • pp.149-152
    • /
    • 2011
  • A new chemiluminescence immunochromatographic analysis system with high sensitivity and high reproducibility was developed for the determination of microcystins (MCs) in water. Horse radish peroxidase (HRP) labeled microcystin monoclonal antibody was used for the sensitive chemiluminescence detection. The chemiluminescence immunochromatographic analysis system was composed of microcystin LR (MCLR)-monoclonal antibody (mAb)-Horse Radish Peroxidase (HRP) conjugate, MCLR-BSA conjugate, luminol, hydrogen peroxide mixture solution, an immunochromatographic assay strip and luminometer. To detect the concentration of microcystins in water, we utilized one spot analysis of the strip instead of flow type analysis. We could detect the microcystins in water at a concentration as low as 9.45 pg/mL with the chemiluminescence (CL) detection.

A rapid and quantitative fluorescent microsphere immunochromatographic strip test for detection of antibodies to porcine reproductive and respiratory syndrome virus

  • Wei, Yanqiu;Yang, Baozhi;Li, Yunlong;Duan, Yongcheng;Tian, Deyu;He, Baoxiang;Chen, Chuangfu;Liu, Wenjun;Yang, Limin
    • Journal of Veterinary Science
    • /
    • 제21권4호
    • /
    • pp.68.1-68.8
    • /
    • 2020
  • A fluorescent microsphere-based immunochromatographic strip test (FICT) was developed for the rapid, sensitive, and quantitative detection of porcine reproductive and respiratory syndrome virus (PRRSV) antibodies at the pen-side. The assay was based on the formation of a sandwich immune-complex (anti-pig IgG-PRRSV antibodies-NSP7/N), which was validated by a comparison with IDEXX-ELISA using 3325 clinical specimens. The diagnostic specificity, sensitivity, and accuracy of FICT were 97.28, 93.41, and 94.95%, respectively. FICT showed a good correlation with the virus neutralization assay. Overall, a promising pen-side diagnostic tool was developed for the rapid and quantitative detection of PRRSV antibodies within 15 min.

One-Step Simultaneous Immunochromatographic Strip Test for Multianalysis of Ochratoxin A and Zearalenone

  • Shim, Won-Bo;Dzantiev, Boris B.;Eremin, Sergei A.;Chung, Duck-Hwa
    • Journal of Microbiology and Biotechnology
    • /
    • 제19권1호
    • /
    • pp.83-92
    • /
    • 2009
  • Individual immunochromatographic assays (ICG) for ochratoxin A (OTA) and zearalenone (ZEA) were optimized and used in the development of a one-step simultaneous immunochromatographic assay (OS-ICG) for the rapid multianalysis of two mycotoxins in corn samples. The nitrocellulose membrane of the OS-ICG was treated with OTA-bovine serum albumin (BSA), ZEA-ovalbumin (OVA), and anti-mouse IgG in the OTA test, ZEA test, and control zones, respectively. Monoclonal antibody-gold conjugates (OTA3 MAb-gold and ZEA2C5 MAb-gold) were sprayed onto the conjugate pad. The visual detection limits were 2.5 and 5 ng/ml for OTA and ZEA, respectively, and the results were obtained within 15 min after starting the analysis. An efficient, simple, and rapid extraction method using 30% MeOH/PBS was established and validated by analyzing the corn samples spiked with OTA/ZEA mixtures (0/0, 5/10, 10/20, and $20/30\;{\mu}g/kg$). The cut-off values of the OS-ICG for the spiked corn were 5 and $10\;{\mu}g/kg$ for OTA and ZEA, respectively. Natural corn samples were analyzed by OS-ICG, direct competitive enzyme-linked immunosorbent assay (DC-ELISA), and HPLC. Results of the OS-ICG were in good agreement with those obtained by DC-ELISA and HPLC. The developed OS-ICG offers a rapid, easy-to-use, and portable analytical system and can be used as a convenient qualitative tool for the on-site simultaneous determination of OTA and ZEA in cereals, food, and agricultural products in one analytical cycle.

육류 및 새싹채소에 오염된 Escherichia coli O157:H7의 신속검출을 위한 면역크로마토그래피법의 개발 (Development of Immunochromatography for Detection of Escherichia coli O157:H7 Contaminated in Meats and Sprouts)

  • 이원경;류희정;송정언;김경열;정도영;김정숙;심원보;정덕화
    • 한국식품과학회지
    • /
    • 제43권5호
    • /
    • pp.618-623
    • /
    • 2011
  • E. coli O157:H7은 요독증후군, 출혈성 대장염 및 설사 등을 유발하는 원인균으로, 전세계적으로 이들의 오염에 따른 식중독 발생이 증가하고 있어, 본 연구에서는 E. coli O157:H7을 신속 정확하게 분석할 수 있는 면역크로마토그래피법을 개발하였고, 보다 신속한 검출을 위하여 육류와 새싹시료를 대상으로 최소 증균시간을 확인하였다. 먼저, 면역크로마토그래피법의 개발을 위해 colloidal gold와 EC MAb를 합성하여 EC MAb-gold conjugate를 제작한 다음, 접합여부를 확인한 결과, test line과 control line에 각각 처리되는 EC MAb와 anti-mouse IgG에 특이적으로 반응하였다. 제작된 EC MAb-gold conjugate를 이용하여 개발된 면역크로마토그래피법의 검출한계는 $1{\times}10^5$ CFU/mL 수준까지 검출이 가능한 것으로 확인되었고, 다른 대장균속 및 주요 식중독균과의 교차반응성은 나타나지 않았다. 개발된 면역크로마토그래피법을 이용하여 임의로 E. coli O157:H7을 오염시킨 돼지고기, 소고기, 닭고기 및 새싹채소를 증균하는 동안 분석한 결과, 돼지고기와 닭고기는 6시간, 소고기는 10시간, 특히 새싹채소는 2시간 후부터 $1{\times}10$ CFU/100 ${\mu}L$ 수준까지 검출이 가능한 것으로 나타났다. 따라서 본 연구에서 개발된 면역크로마토그래피법을 이용하여 육류와 채소 등에 오염된 E. coli O157:H7을 최대 10시간 이내로 신속히 분석할 수 있을 것으로 판단된다.

Sero-positivity and Recognition of Anti-HAV and Anti-HBs in a University of Gumi city

  • Ko, Eun-Eip;Jo, Seon-Min;Kim, Keum-Hwa;Kim, Hyun-Ji;Jin, Cho-Rong;Kim, Hye-Jeong
    • 대한임상검사과학회지
    • /
    • 제44권4호
    • /
    • pp.210-215
    • /
    • 2012
  • Hepatitis virus infection is one of the major problems in Korea. To establish preventive measures for hepatitis A and B virus infection, study on sero-positivity of serum anti-HAV (aHAV) and anti-HBs (aHBs) is needed. The aim of this study was to analyze the sero-positivity and related factors of aHAV and aHBs. We analysed the sero-positivity of serum aHAV and aHBs using ICA (Immunochromatography Assay) method from 102 university students and employees and questionnaire survey was obtained characteristics, vaccination history, past history test, knowledge and information sources of the study subjects. Overall sero-positivity rates of serum aHAV and aHBs were 20.6% and 52.9%, respectively. The sero-positivity rate of aHBs was significantly different by gender (M, 34.9%; F,66.1%) and that of aHAV was significantly different by age (20 age group, 2.7%; 30 age group, 14.3%; 40 age group, 70%; 50 age group, 91.7%). Overall sero-positivity rates of serum aHAV and aHBs by vaccination history rates were 4.9% and 43.1%, respectively. Overall sero-positivity rates of serum aHAV and aHBs by past history test were 10.8% and 52.9%, respectively. Sero-positivity rates of serum aHAV was low in university students. The results of this study could be used effectively as a basic data for establishing effective preventive measures for hepatitis A including vaccination.

  • PDF

Rapid Detection of Infectious Bursal Disease Virus (IBDV) in Chickens by an Immunochromatographic Assay Kit

  • Choi, Kang-Seuk;Oh, Jin-Sik;Jeon, Woo-Jin;Na, Keon-Sok;Lee, Eun-Kyoung;Lee, Youn-Jeong;Sung, Hwan-Woo;Ha, Gun-Woo;Kwon, Jun-Hun
    • 한국가금학회지
    • /
    • 제37권2호
    • /
    • pp.167-172
    • /
    • 2010
  • 닭 전염성 F낭병 (IBD)은 닭에서 전염성이 강하고 발병으로 인하여 양계 산업에 막대한 경제적 피해를 입히는 닭의 바이러스성 전염병이다. 이 연구에서는 수 분 이내에 검사 시료로부터 닭 전염성 F낭병 바이러스를 검출할 수 있는 시판용 면역크로마토그래피법 검사 킷트를 이용하여 IBD 진단에 있어서의 유용성을 조사하였다. 사용한 면역크로마토그래피법 검사 킷트는 닭 전염성 F낭병 바이러스 VP2에 특이적인 단클론 항체를 이용하여 닭 전염성 F낭병 바이러스를 검출하도록 고안되었다. 바이러스 감염 역가를 알고 있는 IBDV를 사용하여 조사한 결과, IC 검사 킷트의 검출 한계는 $10^{3.1}$ 내지 $10^{3.9}$ $EID_{50}$/mL이었다. 이 검사 킷트는 닭의 다른 전염성 바이러스인 뉴캣슬병 바이러스, 닭 전염성 기관지염 바이러스, 조류인플루엔자 바이러스 및 전염성 후두기관염 바이러스에 대하여 비특이 반응을 나타내지 않았다. 고병원성의 IBDV를 실험적으로 감염시킨 후 3일 내지 4일에 폐사한 닭의 장기별로 조사한 결과, 모든 폐사 닭의 F낭, 장편도, 비장, 신장 시료들은 면역크로마토그래피법 검사 킷트에서 강한 양성반응을 나타내었다. 검사 시료 중 F낭 시료가 IC 검사 킷트에서 가장 강한 양성반응을 나타내었다. 폐사 닭의 간, 흉선, 선위의 경우, 각각 검사시료의 87.5%, 37.5% and 0%가 양성 반응을 나타내었다. 면역크로마토그래피법 검사 킷트에서 음성이었던 시료 중 흉선 시료 한 점을 제외한 모든 시료는 DAS-ELISA와 동일한 검사 결과를 나타내었으나, 검사 시료 중 흉선과 선위 일부에서 RT-PCR 검사에서 양성 반응을 나타내었다. 야외 IBD 발생 농장과 비발생 농장에서 수거한 폐사닭 231수의 조직을 면봉으로 도말하여 채취한 시료를 조사하여 RT-PCR법과 비교한 결과, 상대적 민감도와 특이도는 각각 100% (109/109) 및 97.5% (119/122)를 나타났으며, 두 검사 방법간 kappa value는 0.97이었다. 우리의 연구 결과는 IC 검사 킷트는 야외 양계 농장에서 폐사 닭을 대상으로 IBD를 진단하는 데 적용하기에 매우 유용하다는 것을 말해준다.