• 제목/요약/키워드: Immunochromatographic strip

검색결과 16건 처리시간 0.025초

One-Step Simultaneous Immunochromatographic Strip Test for Multianalysis of Ochratoxin A and Zearalenone

  • Shim, Won-Bo;Dzantiev, Boris B.;Eremin, Sergei A.;Chung, Duck-Hwa
    • Journal of Microbiology and Biotechnology
    • /
    • 제19권1호
    • /
    • pp.83-92
    • /
    • 2009
  • Individual immunochromatographic assays (ICG) for ochratoxin A (OTA) and zearalenone (ZEA) were optimized and used in the development of a one-step simultaneous immunochromatographic assay (OS-ICG) for the rapid multianalysis of two mycotoxins in corn samples. The nitrocellulose membrane of the OS-ICG was treated with OTA-bovine serum albumin (BSA), ZEA-ovalbumin (OVA), and anti-mouse IgG in the OTA test, ZEA test, and control zones, respectively. Monoclonal antibody-gold conjugates (OTA3 MAb-gold and ZEA2C5 MAb-gold) were sprayed onto the conjugate pad. The visual detection limits were 2.5 and 5 ng/ml for OTA and ZEA, respectively, and the results were obtained within 15 min after starting the analysis. An efficient, simple, and rapid extraction method using 30% MeOH/PBS was established and validated by analyzing the corn samples spiked with OTA/ZEA mixtures (0/0, 5/10, 10/20, and $20/30\;{\mu}g/kg$). The cut-off values of the OS-ICG for the spiked corn were 5 and $10\;{\mu}g/kg$ for OTA and ZEA, respectively. Natural corn samples were analyzed by OS-ICG, direct competitive enzyme-linked immunosorbent assay (DC-ELISA), and HPLC. Results of the OS-ICG were in good agreement with those obtained by DC-ELISA and HPLC. The developed OS-ICG offers a rapid, easy-to-use, and portable analytical system and can be used as a convenient qualitative tool for the on-site simultaneous determination of OTA and ZEA in cereals, food, and agricultural products in one analytical cycle.

Sputum Processing Method for Lateral Flow Immunochromatographic Assays to Detect Coronaviruses

  • Aram Kang;Minjoo Yeom;Hyekwon Kim;Sun-Woo Yoon;Dae-Gwin Jeong;Hyong-Joon Moon;Kwang-Soo Lyoo;Woonsung Na;Daesub Song
    • IMMUNE NETWORK
    • /
    • 제21권1호
    • /
    • pp.11.1-11.10
    • /
    • 2021
  • Coronavirus causes an infectious disease in various species and crosses the species barriers leading to the outbreak of zoonotic diseases. Due to the respiratory diseases are mainly caused in humans and viruses are replicated and excreted through the respiratory tract, the nasal fluid and sputum are mainly used for diagnosis. Early diagnosis of coronavirus plays an important role in preventing its spread and is essential for quarantine policies. For rapid decision and prompt triage of infected host, the immunochromatographic assay (ICA) has been widely used for point of care testing. However, when the ICA is applied to an expectorated sputum in which antigens are present, the viscosity of sputum interferes with the migration of the antigens on the test strip. To overcome this limitation, it is necessary to use a mucolytic agent without affecting the antigens. In this study, we combined known mucolytic agents to lower the viscosity of sputum and applied that to alpha and beta coronavirus, porcine epidemic diarrhea virus (PEDV) and Middle East respiratory syndrome coronavirus (MERS-CoV), respectively, spiked in sputum to find optimal pretreatment conditions. The pretreatment method using tris(2-carboxyethyl)phosphine (TCEP) and BSA was suitable for ICA diagnosis of sputum samples spiked with PEDV and MERS-CoV. This sensitive assay for the detection of coronavirus in sputum provides an useful information for the diagnosis of pathogen in low respiratory tract.

측방유동방식 신속 DNA 교잡 분석법의 개발 (Development of a Method for Rapid Analysis of DNA Hybridization)

  • 정동석;최의열
    • 미생물학회지
    • /
    • 제39권2호
    • /
    • pp.114-117
    • /
    • 2003
  • 유전자의 기능을 분석하는 과정에서 특정한 염기 서열의 존재여부를 확인하는 분석법은 필수적이다. 현재 사용되고 있는 Southern및 Northern blotting방법은 시간이 오래 걸리며, 온도 등과 같은 외부 조건을 엄격하게 조절하여야 한다. 본 연구에서는 측방유동방식을 이용한 크로마토그라피법을 응용하여 새로운 간편용 DNA분석법을 개발하였다. 이 측방유동형 DNA 분석 스트립은 시료가 적용되는 샘플패드, 이동하여 분리되고 교잡반응이 일어나는 전개용 막, 그리고 시료가 계속하여 이동하기 위한 흡수패드로 구성되어 있다. 모델 시스템으로 HIV와 HCV에 대한 포획 및 표적 DNA를 합성하고 스트립을 제조하였다. 시료를 샘플패드에 적하한 후 교잡반응체의 생성여부와 상대적인 양은 GSI형광 스캐너로 분석하였다. 교잡반응이 매우 빠르게 진행되고 세척과정이 없음에도 불구하고 비특이적인 교차 반응이 거의 관찰되지 않았다. 기존의 DNA 교잡방법과 비교하여 볼 때 이 새로운 방법으로 DNA/DNA 교잡 실험을 보다 더 쉽고, 간편하고, 그리고 빠르게 할 수가 있을 것으로 예상된다.

A Modified Quantum Dot-Based Dot Blot Assay for Rapid Detection of Fish Pathogen Vibrio anguillarum

  • Zhang, Yang;Xiao, Jingfan;Wang, Qiyao;Zhang, Yuanxing
    • Journal of Microbiology and Biotechnology
    • /
    • 제26권8호
    • /
    • pp.1457-1463
    • /
    • 2016
  • Vibrio anguillarum, a devastating pathogen causing vibriosis among marine fish, is prevailing in worldwide fishery industries and accounts for grievous economic losses. Therefore, a rapid on-site detection and diagnostic technique for this pathogen is in urgent need. In this study, two mouse monoclonal antibodies (MAbs) against V. anguillarum, 6B3-C5 and 8G3-B5, were generated by using hybridoma technology and their isotypes were characterized. MAb 6B3-C5 was chosen as the detector antibody and conjugated with quantum dots. Based on MAb 6B3-C5 labeled with quantum dots, a modified dot blot assay was developed for the on-site determination of V. anguillarum. It was found that the method had no cross-reactivity with other than V. anguillarum bacteria. The detection limit (LOD) for V. anguillarum was 1 × 103 CFU/ml in cultured bacterial suspension samples, which was a 100-fold higher sensitivity than the reported colloidal gold immunochromatographic test strip. When V. anguillarum was mixed with turbot tissue homogenates, the LOD was 1 × 103 CFU/ml, suggesting that tissue homogenates did not influence the detection capabilities. Preenrichment with the tissue homogenates for 12 h could raise the LOD up to 1 × 102 CFU/ml, confirming the reliability of the method.

Cronobacter Species의 검출에 관한 연구동향: 총설 (Research Trend of Cronobacter Species Detection Methods: A Review)

  • 권희준;김명희
    • 한국식품영양학회지
    • /
    • 제28권4호
    • /
    • pp.728-736
    • /
    • 2015
  • Cronobacter spp.는 Salmonella spp.와 함께 조제분유에서 발견되는 미생물 중 위험도가 가장 높은 category A에 속하는 균으로 알려져 있다. 1958년 영국에서 처음으로 유아의 뇌수 막염의 원인균으로 보고되었으며, 감염 후 신생아에게서 괴사성 장염, 패혈증 등을 일으켜 후유증으로 시력과 청력 상실 및 신경마비를 일으키기도 한다. 이러한 위험성 때문에 Cronobacter spp.의 신속 검출 및 진단은 식중독 예방에 있어서 중요하다. 따라서 2002년 미국 식품의약품안전국에서는 분유에서의 Cronobacter spp.를 EE broth, VRBG 배지를 이용해 균을 분리 하고, TSA 배지에 순수분리 후 노란색을 발하는 colony를 생화학적 실험을 통해 검출하는 방법을 제시했다. 또한, 우리나라 식품공전에서도 배지를 이용하여 Cronobacter spp.를 검출 하는 방법에 대해 등재하였다. 하지만 배지배양법을 기반으로 하는 Cronobacter spp.의 검출방법은 검출에 소요되는 시간과 노동력 등이 비효율적이라는 단점이 있다. 따라서 많은 시간이 소요되는 배지배양법을 보완하고자 PCR, real-time PCR 방법 및 최근에는 PCR기법과 ELISA, CE-LIF 등을 결합하여 검출하는 방법이 개발되어 Cronobacter spp.의 검출에 사용되기도 하였다. Cronobacter spp.의 검출에 사용되고 있는 분자생물학적 기반의 PCR 및 real-time PCR 기법은 민감도와 특이도가 좋으며, 배지배양법에 의한 검출방법에 비해 검출 시간을 획기적으로 줄일 수 있다는 장점이 있다. 하지만 까다로운 실험과정과 조작에 있어서 필요한 전문적인 기술이 필요함은 한계점으로 사료된다. 면역학적 방법에 의한 Cronobacter spp. 검출에 관한 연구를 통해, 분석에 소요되는 상당시간을 단축할 수 있었으며, 민감하고 특이적인 검출이 가능함을 보여주었다. 특히 일부 연구보고에서 면역학적 검출방법은 고가의 장비가 필요 없으며, 간단한 지침에 따라 모니터링 업무의 수행이 가능하다고 하였다. 면역학적 검출방법에는 ELISA 방법 외에도 immunomagnetic bead, liposome, immunochromatographic strip 등이 개발되고 있다. 우리나라 식품의약품안전처에서는 영 유아 대상 식품의 안전관리를 강화하고자 Cronobacter spp.에 대해서는 '불검출'로 기준을 설정 운영하고 있으며, 지속적으로 이에 관한 규정을 강화하고 있는 실정이다. 따라서, 식품산업체 및 식품 의 제조, 가공, 유통 현장에서 쉽게 모니터링이 가능하며, 신속, 민감하고 특이적인 검출방법의 개발은 지속되어야 한다.

결핵균 분비항원을 이용한 결핵의 혈청학적 진단 방법에 대한 평가 (Evaluation of a Serodiagnostic Method for Tuberculosis by Using Secreted Protein Antigens of Mycobacterium Tuberculosis)

  • 배길한;박은미;김상재
    • Tuberculosis and Respiratory Diseases
    • /
    • 제48권3호
    • /
    • pp.315-323
    • /
    • 2000
  • 연구배경 : 현행 도말 및 배양등의 미생물학적 검사법의 제한점을 보완 또는 보조할 수 있는 신속한 결핵진단 방법의 하나로서 가장 많이 연구 되어온 분야가 혈청학적인 방법이다. 이 중 현재까지 결핵의 혈청학적 진단에 유용성이 높은 것으로 평가되는 항원의 하나가 38KDa으로 대표되는 결핵균 분비항원이다. 마침, 이 38KDa 항원을 주항원 성분으로 하여, 간편하게 실험할 수 있도록 kit화된 제품이 국내외에서 널리 시판되고 있기에(ICT-TB, 호주 ICT Diagnostics사) 이를 이용, 결핵의 혈청학적 진단이 얼마나 유용할 것인지를 평가하고자 하였다. 방 법 : 결핵이 없는 7세 이하 아동 21명과 건강 성인 47명 등 총 68명의 대조군과, 치료 개시 전에는 균양성이었으나 ICT 검사 당시는 균이 나오지는 않았던 치료 중인 폐결핵환자 82명 (결핵성 흉막염 환자 3명 포함) 및 균양성으로 당시 치료 중이던 폐결핵환자 40명 등, 총 122명의 결핵환자를 대상으로 하여 결핵의 혈청학적 진단용 kit인 ICT를 이용하여 시험하였다. 결 과 : 1. 결핵환자가 아닌 대조용 대상자 68명(7세 이하 아동 21명 포함)에 대한 ICT의 양성반응률 (위양성률)은 13.2%였고, 음성반응률 (결핵환자가 아닌 것으로 판정되는 율, true negative)은 86.8%였다. 2. 시험된 대상 결핵환자 122명에 대한 ICT에 의한 양성반응률은 86.9%, 음성반응률은 13.1%였다. 3. 균양성 폐결핵 환자 40명에 대한 ICT 양성률은 95.0% (38명), 음성률은 5.0% (2명)였다. 4. 폐외결핵환자 3명을 포함한, 현재 치료 중에 있는 균음성 결핵환자에 82명에 대한 ICT의 양성반응률은 82.9%(68 명), 음성반응률은 17.1%(14명)였다. 그러나, 균양성 결핵환자와 균음성인 결핵환자간 ICT 양성률에는 통계적으로 유의한 차이가 없었다(P>0.05). 5.ICT의 민강도와 특이도는 모두 87%였으며, 위양성률과 위음성률도 같은 13%였다. 또 유병율이 64% 수준일 때의 양성예측률은 92.2%, 음성예측률은 78.7%였다. 결 론 : ICT의 높은 위양성률과 진단능률(diagnosability) 등을 고려할 때, 결핵이 의심되지만 기존의 도말 및 배양검사 결과를 얻기 어려운 대상자에게만 필요에 따라 제한적으로 활용해볼 수 있는 검사인 것으로 판단되었다.

  • PDF