• Title/Summary/Keyword: Immersion Method

Search Result 632, Processing Time 0.021 seconds

A Research for Possibility of Interactive Cartoon as Edutainment Contents (에듀테인먼트 콘텐츠로서 인터랙티브 만화의 가능성 탐색)

  • Song, Su-Mi;Ahn, Seong-Hye
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2006.11a
    • /
    • pp.190-194
    • /
    • 2006
  • Recently, the education is trying to increase educational effect in self-directed teaming to attract learners' interest and concentration. For that reason, as interaction which makes learners step into lessons spontaneously than a simple convey of knowledge is getting more important, edutainment contents that introduce entertainment for education is being in the limelight. Especially, it needs how to design interaction in which the factors of pleasure and entertainment are emphasized for learners' immersion regarding with edutainment contents based on digital mediums. So, I'm going to present a method of curriculum design on educational factors and how to design interaction on enjoyment factors of interactive cartoon in order to increase educational effect. Through this research, I wish to provide the groundwork which makes interactive cartoon that carries infinite possibility become a new part of edutainment contents.

  • PDF

A Study of the Acoustic Microscope System by Large Aperture Probe (대구경 탐촉자를 이용한 초음파 현미경 시스템 연구)

  • Cho, Yong-Sang;Kim, Jae-Hoon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.23 no.5
    • /
    • pp.475-479
    • /
    • 2003
  • Traditional ultrasonic evaluation to detect micro/small surface cracks is the pulse-echo technique using the normal immersion transducer with high frequency, or the angle beam transducer with surface wave. It is difficult to make the automatic ultrasonic system that is to detect micro and small surface crack and position on the large structure like steel and ceramic rolls, because of the huge data of inspection and the ambiguous position data of transducer. The aim of this study using the high precision scanning acoustic microscope with 10MHz large aperture transducer was to display the real time A, B, C-scan for the automatic ultrasonic system in order to detect the existence and position of surface crack. The ultrasonic method with large aperture transducer was improved the scanning time and speed over 10times faster than traditional methods.

A STUDY ON THE COLOR STABILITY OF PORCELAIN REPAIR RESINS (도재 수리용 레진의 색안정성에 관한 연구)

  • Kim Nan-Young;Jin Tai-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.2
    • /
    • pp.133-141
    • /
    • 2004
  • Statement of problem : Porcelain restorations are widely used in restorative dentistry with a high degree of general success. However, porcelain is brittle and may fracture intraorally. Sometimes a repair may be attempted using composite resin and bonding system available. Color stability of porcelain repair resins affects esthetics and prognosis of prosthesis, so that provides important criteria for the choice of porcelain repair resins. Purpose : The purpose of this study was to investigate the color stability of composite resins used widely as porcelain repair system. Materials and method : Composite resins used for this study were Carisma(Kulzer, Germany), Tetric ceram(Ivoclar, Liechtenstein), Filtek Z250(3M, USA), and Arabesk Top(VOCO, Germany). Thirty disc-shaped specimens($10{\times}2mm$) were fabricated from each composite resin. Color changes of specimens after treatment using thermocycling system(KD-TCS30, Kwang-duk F.A. Korea) and after immersion in methylene blue(0.05% by Wt) were measured with colorimeter(Model Tc-6Fx, Tokyo Denshoku Co.) and obtained data were analyzed. Results and Conclusion: The results obtained from this study were as fo11ows. 1. The color change of Filtek Z250 was lesser than those of Tetric ceram and Arabesk Top after thermocycling (12000 times). 2. All of the composite resins in this study showed increase of color change according to increase of thermocycling frequency. 3. After treatment with methylene blue, the color change of Arabesk Top was greater than those of Carisma and Tetric ceram, and Tetric ceram was more stable than others.

Field Application of Egg and Larval Parasitic Fungi and Chemicals for Controlling Root-knot Nematodes on Some Medicinal Herb (몇종의 선충천적 진균과 화학약제를 이용한 약용작물 뿌리혹선충 방제효과 검토)

  • 박소득;추연대;정기채;심용구;최영연
    • Korean journal of applied entomology
    • /
    • v.32 no.1
    • /
    • pp.105-114
    • /
    • 1993
  • Series of studies were conducted to establish biological and chemical control method for Meloidogyne spp to medical herbs by applied of nematophagous fungi, Arthrobotrys spp, Fusarium spp, and egg parastic fungi, Paecilomyces lilacinus were applied for root-knot nematodes on medicinal herbs, Paeonia albiflora, Codonopsis lanceolata, Cnidium officinale. The results are as follow. In pot experiments, The no. of root gall and egg mass and larvae of Cnidium officinale. The results are as follow. In pot experiments. The no. of root gall and egg mass and larvae of Cnidium officinale, Codonopsis lanceolata, Paeonia japonica lowered in P. Lilacinus treated plots compare to untreated control plots. But A. thaumasia F. oxysporum treated plots were less effective. Effect of egg parasitic fungi and chemical treatment at divided root of Paeonia japonica after sterilized in pot were increased in the fresh weight, root weight, control effect in P. lilacinus treated plots as chemical, Carbo G treated plots compare to untreted control plots. I field experiment, the number of root gall, egg mass and nematode density of Paeonia were also suppressed in P. lilacinus treated plots. It was very effective continuous 2 years and transplanting time on Paeonia japonica infested soil with the M. hapla in field in both region, Chillgok and Euisung treated P. lilacinus as chemical treated plots. Soaking effect of insecticide for Paeonia japonica at diving shoot before transplating in pot were effective for 12hours immersion into 1,000 ppm of Benlate T + Mep Ec, Benlate T + Fenthion EC in pot and field Experiment. In the Examination of fungi activily on P.japonica field 1 year after soil treatment, Number of spore of P. lilacinus were 1,000~1,300 in 3 region except Euisung.

  • PDF

A Study on Systematic Review of Learning with a Robot (로봇활용교육의 체계적 문헌고찰에 관한 연구)

  • Kim, Chul
    • Journal of The Korean Association of Information Education
    • /
    • v.17 no.2
    • /
    • pp.199-209
    • /
    • 2013
  • The study is to review the effects of learning with a robot among regular courses of elementary and middle schools so that the research method of systematic review for papers from 2001 and 2013 was conducted. The database for review were KISS, DBpia, and E-article and it was searched with two options of 'robot & education' and 'learning with a robot'. Initially, 481 papers were searched; but finally 50 were selected after monitoring and extraction execution in line with protocol. Great volume of researches focused on academic skill such as a creativity, problem solving skills and as for research methods, Pretest-Posttest Control Group Design and t-test took the lion's share. As for educational effects, improvements of course interest, immersion, attitude, motivation, creativeness and problem solving skills were identified; but in some researches, insignificant research outcomes were reported. Based on analysis results, considerations for learning with a robot were suggested.

  • PDF

EFFECT OF WATER CONTENT ON THE FLEXURAL STRENGTH DURING REFIRING IN DENIAL PORCELAIN (치과용 도재의 재소성 과정중 수분 함량이 강도에 미치는 영향)

  • Park Hye-Yang;Shim June-Sung;Lee Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.5
    • /
    • pp.656-673
    • /
    • 2003
  • Statement of problem : Long-term exposure of dental porcelain to saliva during temporary cementation of a porcelain-fused to metal (PFM) restoration could affect mechanical strength of dental porcelain if the restoration is refired. Purpose : This work was performed to verify the effect of water on the mechanical strength in aged dental porcelain. Material and method : 63 specimens(Vintage Metalbond opaque and opal powder) were distributed to three experimental groups ; non-water immersed control, immersed and pedried, and immersed and non-predired groups. The changes in flexural strength and fracture toughness after specimen refiring related to Fourier Transform Infrared (FT-IR) spectroscopy. Results : 1. The FT-IR reflectances assigned to molecular bonds of $H_2O$ were noted as significantly different between the first-fired group and three refired groups and between two water-immersed groups and control group after refiring(p<0.05). They were also significantly different between predried group and non-predried group after refiring(p<0.05) 2. For opal specimens, FT-IR absorbances for hydrogen bond of $H_2O$ and silanols were significantly higher in non-predried group than in predreid group(p<0.05). 3 Predried opal group showed the highest mean flexural strength(p<0.05). Non-predried group indicated higher mean flexural strength than control group(p<0.05). 4. The mean fracture toughness for predired group was higher than non-predried group(p<0.05). 5. The difference of leucite crystal size is noted between control group and water-immersed, predried group in scanning electron microscopic study(${\times}10000$).

Evaluation of the Surface Crack by a Large Aperture Ultrasonic Probe (대구경 초음파 탐촉자를 이용한 표면균열 평가)

  • Cho, Yong-Sang;Kim, Jae-Hoon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.24 no.2
    • /
    • pp.180-185
    • /
    • 2004
  • Conventional ultrasonic examination to detect micro and small surface cracks is based on the pulse-echo technique using a normal immersion focused transducer with high frequency, or an angle-beam transducer generating surface waves. It is difficult to make an automatic ultrasonic system that can detect micro and small surface cracks and position in a large structure like steel and ceramic rolls, because of the huge data of inspection and the ambiguous position data of the transducer. In this study, a high-precision scanning acoustic microscope with a 10MHz large-aperture transducer has been used to assess the existence, position and depth of a surface crack from the real-time A, B, C scans obtained by exploiting the ultrasonic diffraction. The ultrasonic method with large aperture transducer has improved the accuracy of the crack depth assessment and also the scanning speed by ten times, compared with the conventional ultrasonic methods.

Characteristics of the AlON-Al2O3 Ceramic Coatings on the Al2021 Alloy by Electrolytic Plasma Processing

  • Wang, Kai;Byeon, Sang-Sik;Kim, Geun-Woo;Park, Keun-Young;Ahmed, Faheem;Koo, Bon-Heun
    • Korean Journal of Materials Research
    • /
    • v.22 no.3
    • /
    • pp.155-158
    • /
    • 2012
  • In this work, AlON-$Al_2O_3$ coatings were prepared on Al2021 alloy by the electrolytic plasma processing (EPP) method. The experimental electrolytes include: 2 g/l NaOH as the electrolytic conductive agent, 10 g/l $Na_2AlO_2$ as the alumina formative agent, and 0.5 g/l $NaNO_2$, $NaNO_3$, and $NH_4NO_3$ as the nitride inducing agents. The effects of different nitrogen inducing agents were studied by a combined compositional and structural analyses of the ceramic coatings carried out by Xray diffractometry (XRD) and scanning electron microscopy (SEM) for the specimens EPP-treated at room temperature for 15 min under a hybrid voltage of 260 DC along with an AC 50 Hz power supply (200 V). Microhardness tests and wear tests were carried out to correlate the evolution of the microstructure and the resulting mechanical properties. Potentiodynamic polarizations and immersion corrosion tests were carried out in 3.5wt% NaCl water solutions under static conditions in order to evaluate the corrosion behavior of the coated samples. The results demonstrate that $NaNO_2$ is proven to be a good nitrogen inducing agent to produce high quality AlON-$Al_2O_3$ ceramic coatings.

Preparation of an Inorganic Scintillator Loaded Film for the Measurement of Surface Contamination and its Performance Test (표면오염 측정용 무기섬광 함침 필름의 제조 및 성능 평가)

  • 서범경;이근우;임난주;박진호;한명진
    • Journal of Energy Engineering
    • /
    • v.13 no.2
    • /
    • pp.93-100
    • /
    • 2004
  • The smear media possible to sampling and radiation detection was prepared and evaluated for the surface contamination using indirect method. The films were made by impregnating Cerium Activated Yttrium Silicate (CAYS) in a polysulfone membrane. The membranes used solution as a dimethylformamide (DMF) and methylene chloride (MC), polysulfone as a polymer matrix and CAYS as a inorganic scintillator. The proximity membranes were prepared with single- and double-layered structure. The solidified methods were immersion to the nonsolvent bath such at water and ethanol and solvent evaporation. The measurement of the photon produced by interaction with radiation and inorganic scintillator used a photomultiflier tube (PMT), amplifier, and counter. In the comparison with the low background alpha/beta counter, the counter rate using inorganic scintillator proximity membrane for the $\^$14/C surface contamination was about 50%. Also. the $^3$H counting results revealed that the prepared membranes were efficient to monitor the surface contaminated with the low energy be-ray emitter nuclides.

The Design and Performance Test of Tracking Actuator for NFR system (근접장 기록 장치를 위한 트랙킹 구동기의 설계 및 실험)

  • Kim, Gi-Hyeon;Lee, Mun-Gu;Gwon, Dae-Gap
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.18 no.8
    • /
    • pp.174-181
    • /
    • 2001
  • Nowadays, the improvement and development of Multi-media and information & communication technology is rapidly processed. They need large data storage capacity. So that, many studies and researches in data storage have been carried out. According to them, the data storage capacity has been increased. But the limitation of storage capacity is happened for several problems. One of them is spot & pit size in optical and magnetic data storage and another is the resolution of actuators. The problems in spot & pit size are covered by new data storage methods-- for examples, AFM(Atomic Force Microscopy), MO(Magneto-optical) system, and NFR(Near-Field decoding) system etc. But the resolution limit of an actuator was not developed and doesn\`t follow up the development of spot & pit size. Because of them, we should improve a resolution of an actuator. Especially, in this paper an actuator if studied and designed for NFR (in using SIL(Solid Immersion Lens) system. It is a dual stage actuator, which consists of a Fine actuator and a Coarse actuator. and should desire 100nm accuracy. Its actuating force generation method is VCM(Voice Coil Motor). The Fine actuator is composed of 4-leaf springs and a bobbin wrapped by coil. The Coarse actuator has Coils and 3-Roller bearings. Also, The Characteristics of designed actuator for NFR system is estimated by Sine-Swept mode and LDV(Laser Doppler Vibro-meter).

  • PDF