• Title/Summary/Keyword: Immediate implants

Search Result 181, Processing Time 0.02 seconds

Analysis of time to failure of orthodontic mini-implants after insertion or loading

  • Jeong, Jong-Wha;Kim, Jong-Wan;Lee, Nam-Ki;Kim, Young-Kyun;Lee, Jong-Ho;Kim, Tae-Woo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.41 no.5
    • /
    • pp.240-245
    • /
    • 2015
  • Objectives: This study was performed to evaluate patterns of failure time after insertion, failure rate according to loading time after insertion, and the patterns of failure after loading. Materials and Methods: A total of 331 mini-implants were classified into the non-failure group (NFG) and failure group (FG), which was divided into failed group before loading (FGB) and failed group after loading (FGA). Orthodontic force was applied to both the NFG and FGA. Failed mini-implants after insertion, ratio of FGA to NFG according to loading time after insertion, and failed mini-implants according to failed time after loading were analyzed. Results: Percentages of failed mini-implants after insertion were 15.79%, 36.84%, 12.28%, and 10.53% at 4, 8, 12, and 16 weeks, respectively. Mini-implant failure demonstrated a peak from 4 to 5 weeks after insertion. The failure rates according to loading time after insertion were 13.56%, 8.97%, 11.32%, and 5.00% at 4, 8, 12, and 16 weeks, respectively. Percentages of failed mini-implants after loading were 13.79%, 24.14%, 20.69%, and 6.9% at 4, 8, 12, and 16 weeks, respectively. Conclusion: Mini-implant stability is typically acquired 12 to 16 weeks after insertion, and immediate loading can cause failure of the mini-implant. Failure after loading was observed during the first 12 weeks.

Bone response around immediately placed titanium implant in the extraction socket of diabetic and insulin-treated rat maxilla (인슐린으로 조절되는 당뇨쥐 상악에서 발치 후 즉시 임플란트 주변에서 골형성)

  • Kim, Dae-Won;Heo, Hyun-A;Lim, Sang-Gyu;Lee, Won;Kim, Young-Sil;Pyo, Sung-Woon
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.37 no.1
    • /
    • pp.30-35
    • /
    • 2011
  • Introduction: Dental implants are used routinely with high success rates in generally healthy individuals. By contrast, their use in patients with diabetes mellitus is controversial because altered bone healing around implants has been reported. This study examined the bone healing response around titanium implants placed immediately in rats with controlled and uncontrolled diabetes. Materials and Methods: Twenty rats were divided into the control, insulin-treated and diabetic groups. The rats received streptozotocin (60 mg/kg) to induce diabetes; animals in the insulin-treated group also received three units of subcutaneous slow-release insulin. A titanium implant ($1.2{\times}3\;mm$) was placed in the extraction socket of the maxillary first molar and bone block was harvested at 1, 2 and 4 weeks. Results: Bone formation around the implants was consistently (from 1 to 4 week post-implantation) slower for the diabetic group than the control and insulin-treated group. Bone morphogenesis in the diabetic rats was characterized by fragmented bone tissues and extensive soft tissue intervention. Conclusion: The immediate placement of titanium implants in the maxilla of diabetic rats led to an unwanted bone healing response. These results suggest that immediate implant insertion in patients with poorly controlled diabetes might be contraindicated.

Marginal bone level change during sequential loading periods of partial edentulous rehabilitation using immediately loaded self-tapping implants: a 6.5-year retrospective study

  • Wang, Jing;Zhang, Zhengchuan;Deng, Feilong
    • The Journal of Advanced Prosthodontics
    • /
    • v.14 no.3
    • /
    • pp.133-142
    • /
    • 2022
  • PURPOSE. A large number of studies have suggested the practicability and predictability of immediate implant function, but few studies have reported marginal bone level changes during sequential loading periods. The purpose of this study was to evaluate the marginal bone remodeling of immediately loaded self-tapping implants both at each time point and during each loading period between two time points. MATERIALS AND METHODS. The patients included in this retrospective study were treated with immediately loaded NobelSpeedy Replace implants between August 2008 and July 2009. Differences in the marginal bone level (MBL) at each time point and the marginal bone level change (ΔMBL) between two time points were analyzed with Bonferroni correction (P < .05). RESULTS. Overall, 24 patients (mean age, 47.3 ± 12.8 years) with 42 immediately loaded implants and a median follow-up of 6.5 years (IQR, 67.8 months) were included. The cumulative survival rate after 10 - 12 years was 95.2%. Continuous but slow marginal bone loss was observed during long-term follow-up. MBL at both 7.5 years and 11 years was significantly lower than that at loading, 6 months, 2 years and 4 years (P < .05). No bone loss difference was found in any period before 4 years of follow up (P > .05). The loading period of 4 years to 7.5 years showed the largest ΔMBL compared to those of other time periods (P < .05). CONCLUSION. Slight bone loss occurred continuously, and more radical changes of marginal bone can be observed during the period of 4-7.5 years. Thus, long-term effective follow-up of immediately loaded implants is needed.

Retrospective Study of Wide-Diameter Implants in Maxillary & Mandibular Molar regions (상하악 대구치 부위에서 넓은 직경 임플란트의 생존율에 대한 후향적 연구)

  • Park, Kyung-Ah;Jeong, Cheol-Woong;Ryoo, Gyeong-Ho;Park, Kwang-Bum;Kim, Young-Joon
    • Journal of Periodontal and Implant Science
    • /
    • v.37 no.4
    • /
    • pp.825-838
    • /
    • 2007
  • Endosseous implants are used in the treatment of various types of tooth loss, and numerous long-term studies have demonstrated the excellent reliability of this method of treatment. However, the increase of implant failure are associated with inadequate quality and/or height of bone. At the end of the 1980s, Wide(>3.75mm) implants were initially used for managing these difficult bone situations. The recommended indications for its use included poor bone quality, inadequate bone height. immediate placement in fresh extraction sockets, and immediate replacement of failed implants. At the 2000s, wider implants(6.0mm and 6.5mm) were used in a few studies. Although good clinical outcomes have been reported in recent years, there is still a controversy on this topic. Therefore, the purpose of this study was to estimate the survival rate of wide implants($6.0{\sim}8.0mm$) in molar regions, evaluating the clinical outcome. In this study, 1135 RBM surfaced wide implants($Rescue^{TM}$, MEGAZEN Co., Korea/595 maxillary, 540 mandibular) were placed in 650 patients(403 male, 247 female/age mean: $51.2{\pm}11.1$ years, range 20 to 83 years). Of the total, 68.3% were used to treat fully or partially edentulous situations, including single-tooth losses and 31.7% were placed immediately after teeth extraction or removal of failed implants, of which all were in the molar regions. Implant diameter and length ranged from 6.0 to 8.0mm and from 5.0 to 10.0mm respectively. The implants were followed for up to 42 months (mean: $14.6{\pm}9.5$ months). Of 1135 placed implants, 58 implants were lost. Among them, 53 implants were lost within 12 months after implant placement. The survival rate was 93.6% in the maxilla and 96.3% in the mandible, yielding an overall survival rate of 94.9%, for up to 42 months. As the result of Cox regression model, prosthetic type, sinus graft, and patient gender have an statistical significance on the implant survival rate in this study. This study suggests that the use of wide implants($6.0{\sim}8.0mm$) would provide a predictable treatment alternative in posterior areas.

Retrospective study on marginal bone resorption around immediately loaded implants (즉시 하중 임플란트에서 변연골 흡수량에 관한 후향적 연구)

  • Lee, Sung-Hoon;Jung, Ji-Hye;Lee, Jin-Han;Cho, Hye-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.2
    • /
    • pp.114-119
    • /
    • 2018
  • Purpose: Patients who treated implant immediate loading within a week after implant placement at Wonkwang University Dental Hospital Implant Center were evaluated marginal bone resorption. These retrospective analyses are intended to reinforce the clinical evidence for the implant immediate loading. Materials and methods: Medical history and radiographic data were investigated, which were the patients' who treated implant immediate loading and restoration with provisional prostheses between January 2005 and June 2016, at Wonkwang University Dental Hospital Implant Center. Total number of implants was 70, marginal bone resorption was measured according to implant length, diameter and connection type. To measure marginal bone resorption, periapical radiographs were taken when the implants were placed and after 6 month. Statistical analysis was done in Mann-whitney U test and Kruskal-wallis test with SPSS 22.0 software (P<.05). Results: Mean marginal bone resorption around immediately loaded implants according to implant connection type was shown $1.24{\pm}0.72mm$ in internal hexagon connection type and $1.73{\pm}1.27mm$ in external hexagon connection type. There was no statically significant difference in marginal bone resorption with implant length and diameter. Conclusion: Implants with immediated loading in internal hexagon connection type showed less marginal bone resorption significantly than in external hexagon connection type.

CT and scintigraphic evaluation of osseointegration following immediate versus delayed implantation in dogs (개에서 즉시형과 지연형 인공치아 식립후 골유합에 대한 CT와 신티그라피 평가)

  • Kim, Juoog-Hyun;Lee, Jae Yeong;Lee, Won-Guk;Oh, Won Young;Kim, So-Seob;Kang, Seong Soo;Choi, Seok Hwa
    • Korean Journal of Veterinary Research
    • /
    • v.44 no.1
    • /
    • pp.131-136
    • /
    • 2004
  • Osseointegration involves anchoring dental implants to stable bone rather than to soft-tissue. Clinical osseointegration is currently defined as the process whereby alloplastic material is asymptomatically and rigidly fixed and maintained in bone during functional loading. Full osseointegration is necessary for the success of long-term dental implants. Recent developments in computer assisted measurement of bone formation have improved maxillofacial examination and osseointegration. Computer assisted examination has also proved effective in dental implantology. This investigation was aimed to determine osseointegration in immediate and delayed implantation in the dog mandible using dental computed tomography (CT) and bone scintigraphy. Five adult (mean age of 2 years) mongrel dogs with a mean weight of 9.1 kg were used in this investigation. Titanium alloy implant systems with 4 mm in diameter and 10 mm in length were chosen for insertion. The second and third left mandibular premolars in each dog were extracted for the delayed implant insertion. Twelve weeks later, the second and third right mandibular premolars were extracted for the immediate implant insertion. Before the delayed and immediate implantation procedures and 0, 4, 8, and 12 weeks after the insertions, dental CT and scintigraphy were conducted. The CT and scintigraphic images indicate that reconstruction of bone surrounding of the immediate implant can be as successful as reconstruction of bone surrounding of the delayed implant.

AN EVALUATION OF THE PRIMARY IMPLANT STABILITY AND THE IMMEDIATE LOAD-BEARING CAPACITY ACCORDING TO THE CHANGE OF CORTICAL BONE THICKNESS (치밀골 두께 변화에 따른 임플랜트 1차안정성과 즉시하중부담능 평가)

  • Yi Yang-Jin;Park Chan-Jin;Cho Lee-Ra
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.2
    • /
    • pp.248-257
    • /
    • 2005
  • Statement of problem. Cortical bone plays an important role in the primary implant stability, which is essential to immediate/early loading. However, immediate load-bearing capacity and primary implant stability according to the change of the cortical bone thickness have not been reported. Purpose. The objectives of this study were (1) to measure the immediate load-bearing capacity of implant and primary implant stability according to the change of cortical bone thickness, and (2) to evaluate the correlation between them. Material and methods.48, screw-shaped implants (3.75 mm$\times$7 mm) were placed into bovine rib bone blocks with different upper cortical bone thickness (0-2.5 mm) and resonance frequency (RF) values were measured subsequently. After fastening of healing abutment. implants were subjected to a compressive load until tolerated micromotion threshold known for the osseointegration and load values at threshold were recorded. Thereafter, RF measurement after loading, CT taking and image analysis were performed serially to evaluate the cortical bone quality and quantity. Immediate load-bearing capacity and RF values were analyzed statistically with ANOVA and post-hoc method at 95% confidence level (P<0.05). Regression analysis and correlation test were also performed. Results. Existence and increase of cortical bone thickness increased the immediate load-bearing capacity and RF value (P<0.05) With the result of regression analysis, all parameter's of cortical bone thickness to immediate load-bearing capacity and resonance frequency showed significant positive values (P<0.0001). A significant high correlation was observed between the cortical bone thickness and immediate load-beating capacity (r=0.706, P<0.0001), between the cortical bone thickness and resonance frequency (r=0.753, P<0.0001) and between the immediate load-bearing capacity and resonance frequency (r=0.755, P<0.0001). Conclusion. In summary, cortical bone thickness change affected the immediate load-baring capacity and the RF value. Although RF analysis (RFA) is based on the measurement of implant/bone interfacial stiffness, when the implant is inserted stably, RFA is also considered to reflect implant/bone interfacial strength of immediately after placement from high correlation with the immediate load-baring capacity. RFA and measuring the cortical bone thickness with X-ray before and during surgery could be an effective diagnosis tool for the success of immediate loading of implant.

CLINICAL APPLICATION OF TRANSITIONAL IMPLANTS (Transitional implant를 이용한 임시수복과 최종 수복)

  • Kim, Yu-Lee;Min, Seung-Ki
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.27 no.6
    • /
    • pp.575-580
    • /
    • 2005
  • Transitional implants were developed to support provisional restorations and to allow for load-free osseointegration of conventional implants while a patient was provided with immediate esthetics and function and are usually placed simultaneously at the time of definitive implant placement. Transitional implants are placed in a non-submerged fashion in a single-stage surgery and are designed to be immediately loaded. They generally are made of commercially pure titanium or titanium alloy and are designed as 1-piece implants composed of root and crown replacement segments. Transitional implants can be used in a wide range of indications, such as basic use as temporary implant, to support and protect the primary implants during the healing phase, single crown in the edentulous anterior region of mandibular, anchorage for orthodontic treatment, support a surgical and radiographic template, and primary implant to extremely atrophied alveolar crests of the mandible and maxilla. This article describes the clinical use of transitional implants to support the provisional complete denture and single crown in the restricted edenturous central incisor region of mandible.

Numerical Analysis on Posterior Prosthesis of Implant Temporary Teeth Combination Bridge (임플란트 임시치아 결합형 브리지의 구치부 보철물에 대한 수치해석)

  • Seo, Kyung-Hyo;Lee, Chi-Woo;Moon, Byung-Cheol
    • Journal of Power System Engineering
    • /
    • v.18 no.5
    • /
    • pp.60-65
    • /
    • 2014
  • This research examined an immediate loading capable of providing a masticatory function and financial affordability while satisfying every requirement of a useful immediate loading. In this research, numerical value analysis was performed on couple-type posterior teeth implants developed by making up for the problems of extant implants. As a result of examining the effects of external impacts on extant implants and their deformation, relatively lager deformations separated from a molar were found concerning molar deformation implant with the maximum deformation level being approximately 1.657mm. In this research, the improved implant showed much improvement in terms of impact analysis in its deformation dispersion status after unloading the impulsive load from a punch. As for the case of hepf, about 1.657mm occurred but the improved model showed about 0.9217mm, exhibiting 55.6% advancement.

Immediate Direct-To-Implant Breast Reconstruction Using Anatomical Implants

  • Kim, Sung-Eun;Jung, Dong-Woo;Chung, Kyu-Jin;Lee, Jun Ho;Kim, Tae Gon;Kim, Yong-Ha;Lee, Soo Jung;Kang, Su Hwan;Choi, Jung Eun
    • Archives of Plastic Surgery
    • /
    • v.41 no.5
    • /
    • pp.529-534
    • /
    • 2014
  • Background In 2012, a new anatomic breast implant of form-stable silicone gel was introduced onto the Korean market. The intended use of this implant is in the area of aesthetic breast surgery, and many reports are promising. Thus far, however, there have been no reports on the use of this implant for breast reconstruction in Korea. We used this breast implant in breast reconstruction surgery and report our early experience. Methods From November 2012 to April 2013, the Natrelle Style 410 form-stable anatomically shaped cohesive silicone gel-filled breast implant was used in 31 breasts of 30 patients for implant breast reconstruction with an acellular dermal matrix. Patients were treated with skin-sparing mastectomies followed by immediate breast reconstruction. Results The mean breast resection volume was 240 mL (range, 83-540 mL). The mean size of the breast implants was 217 mL (range, 125-395 mL). Breast shape outcomes were considered acceptable. Infection and skin thinning occurred in one patient each, and hematoma and seroma did not occur. Three cases of wound dehiscence occurred, one requiring surgical intervention, while the others healed with conservative treatment in one month. Rippling did not occur. So far, complications such as capsular contracture and malrotation of breast implant have not yet arisen. Conclusions By using anatomic breast implants in breast reconstruction, we achieved satisfactory results with aesthetics better than those obtained with round breast implants. Therefore, we concluded that the anatomical implant is suitable for breast reconstruction.