• Title/Summary/Keyword: Imaging studies

Search Result 1,638, Processing Time 0.028 seconds

Significance of the Failure Patterns in Cervical Lymph Nodes Achieving a Complete Response to Radical Radiotherapy (근치적 방사선치료에 완전반응을 보인 경부 림프절에서의 재발 양상 및 그 의의)

  • Nam, Ji-Ho;Kim, Won-Taek;Ki, Yong-Kan;Kim, Dong-Hyun;Choi, Young-Jin;Cho, Kyu-Sup;Lee, Jin-Choon;Lee, Byung-Joo;Kim, Dong-Won
    • Radiation Oncology Journal
    • /
    • v.28 no.1
    • /
    • pp.9-15
    • /
    • 2010
  • Purpose: This study was performed to examine the neck failure patterns after a complete response (CR) to definitive radiotherapy for advanced head and neck cancer patients, as well as evaluate the clinical significance of the results of this study. Materials and Methods: Between 1987 and 2008, the clinical data of patients who had been treated with radical radiotherapy for primary squamous cell carcinomas and enlarged cervical lymph nodes was analyzed retrospectively. Ultimately, the cases that showed CR of the cervical lymph node lesions to full-dose radiotherapy were included in this study. The recurrent rate and sites in the cervical lymphatic area were evaluated periodically by radiologic imaging studies, along with some factors which might have affected the rate of recurrence. Results: A total of 73 patients who achieved CR in neck area after radiotherapy were included in this study. The rate of subsequent neck failure among those patients was 19.2%. There was only a 5.5% failure rate in the 55 patients who underwent radiotherapy in their primary site. Eighty percent of the recurrent cases were found within 3 years (median follow-up, 68 months). The majority of neck recurrent cases (47%) were accompanied with the failure of the primary lesions. The initial response of the primary site and the method of radiotherapy simulation were significant prognostic factors associated with the nodal recurrence rate. Conclusion: The recurrence rate of cervical nodes in patients with CR to radiotherapy in the primary site and neck area was about 5%. These patients could be followed up with close observation without a planned neck dissection.

A Study of Dopamine Transporter Imaging and Comparison of Noninvasive Simplified Quantitative Methods in Normal Controls and Parkinson's Patients ([I-123]IPT SPECT를 이용한 정상인과 파킨슨 환자의 도파민 운반체의 영상화 및 단순화된 정량분석 방법들의 비교연구)

  • Bong, Jung-Kyun;Kim, Hee-Joung;Im, Joo-Hyuck;Yang, Seoung-Oh;Moon, Dae-Hyuk;Ryu, Jin-Sook;Nam, Ki-Pyo;Cheon, Jun-Hong;Kwon, Soo-Il;Lee, Hee-Kyung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.30 no.3
    • /
    • pp.315-324
    • /
    • 1996
  • The purpose of this study was to compare the specific binding ratio method with model-based methods in estimating the transporter parameter $k_3/k_4$ in normal controls and Parkinson's patients with [I-123]IPT SPECT and to evaluate the usefulness of [I-123]IPT SPECT. $6.5{\pm}1.1$ mCi ($239.0{\pm}40.3$ MBq) of [$^{123}I$]IPT was intravenouly injected as a bolus into six normal controls(age:$45{\pm}13$) and seventeen patients(age:$55{\pm}8$) with Pakinson's disease(PD). The transporter parameter $k_3/k_4$ was derived using the Ichise's graphical method($R_v$) and Lassen's area ratio method($R_A$) for the dynamic IPT SPECT data without blood samples. Then, the relationships between the transporter parameter $R-v,\;R_A$ and the ratio of (BG-OCC)/OCC at 115 minutes were evaluated by linear regression analysis. $R_vs$ by Ichise's graphical method for NC and PD were $2.08{\pm}0.29$ and $0.78{\pm}0.31$, respectively. $R_As$ by Lassen's area ratio method for NC and PD were $1.48{\pm}0.16$ and $0.65{\pm}0.24$, respectively. The correlation coefficients between (BG-OCC)/OCC and $R_v$, (BG-OCC)/OCC and $R_A$, and $R_v$ and $R_A$ were 0.93, 0.90, 0.99 and their corresponding slopes were 0.54, 0.34, and 0.65, respectively. The $R_v$ and $R_A$ of NC were significantly higher than the ones of PD. That is, the $k_3/k_4$ of NC was clearly separated from the one of PD. $k_3/k_4$ showed a good correlation with the ratio of (BG-OCC)/OCC. The results indicate that the noninvasive simplified quantitative methods may be useful to measure the transporter parameter $k_3/k_4$ and the specific binding ratio method can be used for quantitative studies of dopamine transporter with [I-123]IPT SPECT in humans brains.

  • PDF

Limb Salvage in the Treatment of the Upper Extremity Bone Tumors (상지에 발생한 악성 및 침윤성 양성골종양에 대한 사지 구제술)

  • Hahn, Soo-Bong;Shin, Kyoo-Ho;Kim, Bum-Soo
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.1 no.2
    • /
    • pp.154-163
    • /
    • 1995
  • With the development of anticancer chemotherapy and improved radiographic imaging studies, limb salvage operation became possible in the treatment of malignant and aggressive benign tumors. High grade sarcomas of the shoulder or the upper extremity can be surgically treated with a forequarter amputation, shoulder disarticulation or limb salvage surgery such as Tikhoff-Linberg procedure, segmental resection and replacement with endoprosthesis, segmental resection and replantation, or segmental resection and free vascularized bone graft. Among them the limb salvage surgery showed not only preservation of the remained upper extremity but also the excellent functional results. When comparing amputation and limb salvage operation while performing anticancer chemotherapy in both cases, 5 year survival rate, local recurrence, and distant metastasis did not show much difference. We studied 13 cases of limb salvage for the malignant and aggressive benign bone tumor of the upper extremity from March 1986 to December 1993 at Severance hospital. The summarized results were as follows. 1. There were 21 cases of malignant bone tumors and 5 cases of benign aggressive ones. 2. Of the 26 cases of malignant and benign aggressive bone tumors, limb salvage procedures such as Tikhoff-Linberg operation(8 cases), endoprosthetic replacement(2 cases), segmental resection and replantation(2 cases), and segmental resection and free vascularized fibular graft(l case) were done in 13 cases. 3. In 13 patient on whom the limb salvage procedure was performed, there were 3 osteosarcomas, 4 chondrosarcomas, 3 giant cell tumors, 1 Ewing's sarcoma, 1 leiomyosarcoma and 1 chondroblastoma. 4. In 13 patients, there was no local recurrence nor distant metastasis except one who had a segmental resection of the entire humerus part including glenoid and then postoperative anticancer chemotherapy for the treatment of the Ewing's sarcoma of the entire shaft of the humerus with pathological fracture. Local recurrence occurred 2 years and 6 months postoperatively in this Ewing's sarcoma patient, so forequarter amputation was performed and the irradiation and the anticancer chemontherapy were performed, but multiple bony metastasis developed and died of the disease 22 months after local recurrence. 5. The patients were followed-up for I year to 7 years and 5 months(average 4 years 5 months). 6. In 8 cases in which Tikhoff-Linberg procedure was performed, the function of the hand was almost normal. 7. Segmental resection and endoprosthetic replacement was performed in 2 cases, and the function of the remained upper extremity was good with no evidence of aseptic loosening or nerve palsy. 8. In 1 case of segmental resection and free vascularized fibular graft for the patient of the chon drosarcoma in the humerus, the function of the shoulder, elbow and hand was nearly normal. 9. In I case of leiomyosarcoma which involved both forearm muscles and bone near wrist joint, segmental resection and replantation was performed, and the patient has useful hand function.

  • PDF

Evaluation of Cerebral Aneurysm with High Resolution MR Angiography using Slice Interpolation Technique: Correlation wity Digital Subtraction Angiography(DSA) and MR Angiography(MRA) (Slice Interpolation기법의 고해상도 자기공명혈관조영술을 이용한 뇌동맥류의 진단 : 디지탈 감산 혈관조영술과 자기공명 혈관조영술의 비교)

  • ;;;Daisy Chien;Gerhard Laub
    • Investigative Magnetic Resonance Imaging
    • /
    • v.1 no.1
    • /
    • pp.94-102
    • /
    • 1997
  • Purpose: There have been some efforts to diagnose intracranial aneurysm through a non-invasive method using MRA, although the process may be difficult when the lesion is less than 3mm. The present study prospectively compares the results of high resolution, fast speed slice interpolation MRA and DSA thereby examing the potentiality of primary non-invasive screening test. Materials and Methods: A total of 26 cerebral aneurysm lesions from 14 patients with subarachnoid hemorrhage from ruptured aneurysm (RA) and 5 patients with unruptured aneurysm(UA). In all subjects, MRA was taken to confirm the vessel of origin, definition of aneurysm neck and the relationship of the aneurysm to nearby small vessels, and the results were compared with the results of DSA. The images were obtained with 1.5T superconductive machine (Vision, Siemens, Erlangen, Germany) on 4 slabs of MRA using slice interpolation. The settings include TR/TE/FA=30/6.4/25, matrix $160{\times}512$, FOV $150{\times}200$, 7minutes 42 seconds of scan time, effective thickness of 0.7 mm and an entire thickness of 102. 2mm. The images included structures from foramen magnum to A3 portion of anterior cerebral artery. MIP was used for the image analysis, and multiplanar reconstruction (MPR) technique was used in cases of intracranial aneurysm. Results: A total of 26 intracranial aneurysm lesions from 19 patients with 2 patients having 3 lesion, 3 patients having 2 lesions and the rest of 14 patients having 1 lesion each were examined. Among those, 14 were RA and 12 were UA. Eight lesions were less than 2mm in size, 9 lesions were 3-5mm, 7 were 6-9mm and 2 were larger than IOmm. On initial exams, 25 out of 26 aneurysm lesions were detected in either MRA or DSA showing 96% sensitivity. Specificity cannot be estimated since there was no true negative of false positive findings. When MRA and MPR were used concurrently for the confirmation of size and shape, the results were equivalent to those of DSA, while in the confirmation of aneurysm neck and parent vessels, the concurrent use of MRA and MPR was far superior to the sole use of either MRA or DSA. Conclusion: High resolution MRA using slice interpolation technique showed equal results as those of DSA for the detection of intracranial aneurysm, and may be used as a primary non-invasive screening test in the future.

  • PDF

FDG Uptake in the Pathologically Proven Papillary Thyroid Cancer (수술전에 시행한 PET에서 갑상선 유두상암의 FDG 섭취양상)

  • Kim, Tae-Sung;Yun, Mi-Jin;Cho, Arthur;Lee, Jong-Doo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.41 no.1
    • /
    • pp.22-29
    • /
    • 2007
  • Purpose: Metastatic thyroid cancers with I-131 uptake have been known to show no increase of FDG uptake whereas those without I-131 uptake tend to demonstrate increased uptake on PET. In this study, we evaluated the degree of FDG uptake in primary thyroid cancers of papillary histology before surgery. Material & Methods: Forty FDG PET studies were performed on the patients who had papillary cancer proven by fine needle aspiration. The degree of FDG uptake was visually categorized as positive or negative (positive if the tumor showed discernible FDG; negative if the tumor didn't) and the peak standard uptake value (peak SUV) of the papillary thyroid cancer (PTC) were compared with the size of PTC. Results: The mean size of 26 PTC with positive FDG uptake was $1.9{\pm}1.4\;cm(0.5{\sim}5\;cm)$. In 13 PTC with negative FDG uptake, the mean size of those was $0.5{\pm}0.2\;cm\;(0.2{\sim}0.9\;cm)$. All PTC larger than 1cm ($2.5{\pm}1.4\;cm,\;1{\sim}5\;cm$) have positive FDG uptake (peak $SUV=6.4{\pm}5.7,\;1.7{\sim}22.7$). Among the micropapillary thyroid cancer (microPTC; PTC smaller than 1cm), 8 microPTC show positive FDG uptake(peak $SUV=2.9{\pm}1.3,\;1.7{\sim}5.5$), while 13 microPTC show negative finding(peak $SUV=1.3{\pm}0.2,\;1.1{\sim}1.7$). The size of microPTC with positive FDG uptake is significantly larger than that of microPTC with negative FDG uptake ($0.7{\pm}0.1\;cm$ vs $0.4{\pm}0.2\;cm$, p=0.01). Conclusion: All PTCs larger than 1cm show positive FDG uptake in our study. In other words, thyroid lesions larger than 1cm with negative FDG uptake are unlikely to be PTC. So far, only poorly differentiated thyroid cancers are known to show increased FDG uptake. Our results seem to be contradictory to what is known in the literature. Further study is needed to understand better the significance of increased FDG uptake in PTC in relation to expression of NIS and GLUT.

The Short Term and Intermediate Term Results of using a T-tube in Patients with Tracheal Stenosis (기관 협착 환자에서의 T-튜브의 중단기 결과)

  • Sa, Young Jo;Moon, Seok-Whan;Kim, Young-Du;Jin, Ung;Park, Jae-Kil;Kim, Jae Jun;Kim, Chi-Kyung;Jo, Keon Hyon;Park, Chan Beom;Yim, Hyeon Woo
    • Journal of Chest Surgery
    • /
    • v.42 no.1
    • /
    • pp.63-71
    • /
    • 2009
  • Background: The treatment of tracheal stenosis includes less invasive bronchoscopic intervention and more invasive segmental resection & anastomosis. Depending on the patient's clinical features, sometimes all these methods are inappropriate. Silicone T-tube stenting has recently been used as an alternative, safe management of tracheal stenosis. We studied the short term and Intermediate term results of using T-tubes in patients with tracheal stenosis, and this tracheal stenosis was caused by various underlying diseases. Material and Method: We retrospectively reviewed 57 patients with tracheal stenosis and who were treated with T-tubes between Jan 1997 and Apr 2007. Based on the patient's medical records and the imaging studies, we evaluated the clinical findings and status of T-tube removal. Result: There was no T-tube related morbidity or mortality in this series. On follow-up, one patient underwent sleeve resection and end-to-end anastomosis. The T-tube could be successfully removed from 13 patients (13/57, 22.8%) without additional interventions. For another four patients, a T-tube was again inserted after removal of the first T-tube due to tracheomalacia or recurrent stenosis. Four patients died of underlying disease and cancer. The patients' gender and previous tracheostomy significantly affected T-tube removal. By contrast, multiple logistic regression analysis identified gender as a predictor of successfully removing a T-tube. Gender (p=0.033) and previous tracheostomy (p=0.036) were the two factors for success or failure of T-tube removal. Conclusion: A T-tube provided reliable patency of a stenotic airway that was caused by any etiology. We have proven that using a T-tube is safe and effective therapy for patients with tracheal stenosis for the short term or the intermediate term.

Effects of 166Holmium and 166Holmium-chitosan Complex(166Ho-CHICO) on Normal Brain of Rats (홀뮴 및 홀뮴-키토산 복합체가 정상 백서 뇌에 미치는 효과에 대한 연구)

  • Sun, Jing He;Joh, Chul W;Ahn, Young Hwan;Park, Chan Hee;Shim, Chull;Park, Kyung Bae;Cho, Kyung Gi
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.10
    • /
    • pp.1309-1315
    • /
    • 2000
  • Objectives : We performed an in vivo experiment to investigate the effect of $^{166}Holmium$ and $^{166}Holmium$-chitosan complex($^{166}Ho$-CHICO) on the normal brain of rats and to determine the sublethal dose of $^{166}Ho$-CHICO. Materials and Methods : $^{166}Ho$ is a beta and gamma ray emitter. $^{166}Ho$-CHICO is a novel radio-pharmaceutical complex with chitosan to facilitate the transport of $^{166}Ho$ obtained from Korea Atomic Energy Research Center(Taejon, Korea). It is in acidic form and becomes gel state at alkaline pH. One hundred and seventy consecutive rats were divided into four groups : $^{166}Ho$ treated(n=50), $^{166}Ho$-CHICO treated(n=57), saline treated(n=5) and chitosan treated(n=5) groups. $^{166}Ho$ and $^{166}Ho$-CHICO were injected into the rat brain stereotactically with various doses of 0.1mCi/$20{\mu}l$, 0.2mCi/$20{\mu}l$, 0.3mCi/$20{\mu}l$, and 0.4mCi/$20{\mu}l$ using an automated microinjector. Nuclear imaging, histopathological and hematological studies were performed in 10 rats in each group at 1 day, 3days, 7 days, 1 month and 3 months after the injections. Results : An infiltration of inflammatory cells and necrotic changes were noted in $^{166}Ho$ treated group at 1 week after the injection. A wedge-shaped tissue defect due to necrosis, lined with infiltrated glial cells in $^{166}Ho$ treated group and a cystic defect lined with reactive astroglial cells in $^{166}Holmium$-CHICO treated group at 3 months after the injection were observed. $^{166}Ho$ alone without chitosan leaked out and caused necrotic lesion on the cerebral surface but $^{166}Holmium$-CHICO treated group did not show this feature. As the dose of $^{166}Ho$ increased, the mortality rates were also increased. The mortality rate of the $^{166}Holmium$-CHICO group was higher than the $^{166}Ho$ treated group at a dose of 0.4mCi/$20{\mu}l$/300g. There was no detectable radioactivity due to the leakage or extravasation from the injected site of the brain on the scintigraphy performed at 1 hour, 24 hours and 48 hours after the injection. There was also no detectable activity of $^{166}Holmium$-CHICO in other organs including spleen, liver and kidney. Conclusions : $^{166}Ho$-CHICO did not leak out to the critical cortical surface of the brain from the injection site and induced radiation changes of the parenchyma around the injection site without cortical damage. The sublethal dose of $^{166}Ho$-CHICO for the normal brain in rats was determined to be 0.2mCi/$20{\mu}l$/300g.

  • PDF

Comparison of using CBCT with CT simulator for radiation dose of treatment planning (CBCT와 Simulation CT를 이용한 치료계획의 선량비교)

  • Cho, jung-keun;Kim, dae-young;Han, tae-jong
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2009.05a
    • /
    • pp.1159-1166
    • /
    • 2009
  • The use of cone-beam computed tomography(CBCT) has been proposed for guiding the delivery of radiation therapy. A kilovoltage imaging system capable of radiography, fluoroscopy, and cone-beam computed tomography(CT) has been integrated with a medical linear accelerator. A standard clinical linear accelerator, operating in arc therapy mode, and an amorphous-silicon (a-Si) with an on-board electronic portal imager can be used to treat palliative patient and verify the patient's position prior to treatment. On-board CBCT images are used to generate patient geometric models to assist patient setup. The image data can also, potentially, be used for dose reconstruction in combination with the fluence maps from treatment plan. In this study, the accuracy of Hounsfield Units of CBCT images as well as the accuracy of dose calculations based on CBCT images of a phantom and compared the results with those of using CT simulator images. Phantom and patient studies were carried out to evaluate the achievable accuracy in using CBCT and CT stimulator for dose calculation. Relative electron density as a function of HU was obtained for both planning CT stimulator and CBCT using a Catphan-600 (The Phantom Laboratory, USA) calibration phantom. A clinical treatment planning system was employed for CT stimulator and CBCT based dose calculations and subsequent comparisons. The dosimetric consequence as the result of HU variation in CBCT was evaluated by comparing MU/cCy. The differences were about 2.7% (3-4MU/100cGy) in phantom and 2.5% (1-3MU/100cGy) in patients. The difference in HU values in Catphan was small. However, the magnitude of scatter and artifacts in CBCT images are affected by limitation of detector's FOV and patient's involuntary motions. CBCT images included scatters and artifacts due to In addition to guide the patient setup process, CBCT data acquired prior to the treatment be used to recalculate or verify the treatment plan based on the patient anatomy of the treatment area. And the CBCT has potential to become a very useful tool for on-line ART.)

  • PDF

Clinical Significance of Tumor Markers in Gastric Cancer Patients after Curative Resection (근치적 절제술을 시행한 위암 환자에서 종양 표지자의 임상적 의미)

  • Kim, Sa-Young;Ha, Tae-Kyung;Kwon, Sung-Joon
    • Journal of Gastric Cancer
    • /
    • v.9 no.3
    • /
    • pp.136-142
    • /
    • 2009
  • Purpose: This clinical study was conducted to evaluate the predictive value of tumor markers for recurrence and the clinical significance of false positive findings after curative gastrectomy in patients with gastric cancer. Materials and Methods: Two hundred ninety patients with gastric cancer who underwent gastrectomy with curative intent were evaluated retrospectively. We analyzed the correlations between changes in tumor markers (CEA, CA 19-9, AFP, and CA-125) and clinicopathologic data, and basis for changes in tumor markers without recurrence during the follow-up period. Results: The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of tumor markers for recurrence were 75.0%, 64.6%, 23.1%, 94.8%, and 65.9% respectively. Among 36 patients with recurrences, 10 patients (27.8%) had elevated tumor markers prior to positive findings on imaging studies, while 13 patients (36.1%) had concomitant elevation in tumor markers. At least 1 of the 4 tumor markers increased in 90 of 290 patients during the follow-up period; however, there was no evidence of tumor recurrence. Twenty patients had persistently elevated tumor markers, while the tumor marker levels in 70 patients returned to normal level within $9.08\pm7.2$ months. The patients with pulmonary disease, hepatobiliary disease, diabetes, hypertension, or herbal medication users had elevated tumor markers more frequently than patients without disease (P<0.001). Conclusion: Although detecting recurrence of gastric cancer with tumor markers may be useful, false positive findings of tumor markers are common, so surgeons should consider other chronic benign diseases and medical conditions when tumor markers increase without evidence of recurrence.

  • PDF

Effectiveness of Positron Emission Tomography in the Pre-operative Staging of Gastric Cancer (위암환자의 술 전 병기 결정에서 PET-CT의 유용성)

  • Park, Shin-Young;Bae, Jung-Min;Kim, Se-Won;Kim, Sang-Woon;Song, Sun-Kyo
    • Journal of Gastric Cancer
    • /
    • v.9 no.3
    • /
    • pp.110-116
    • /
    • 2009
  • Purpose: The aim of this study was to examine the usefulness of positron emission tomography (PET)-computed tomography (CT) in the pre-operative staging of gastric cancer. Materials and Methods: Between February 2006 and August 2008, PET-CT and CT were performed on 70 patients diagnosed with gastric cancer by gastrofiberscopic biopsy. The sensitivities, specificities, Positive predictive value (PPV), and negative predictive value (NPV) of PET-CT and CT imaging for the detection of gastric cancer TNM staging were compared. Results: The detection rates for the primary tumor were as follows: PET-CT, 81.4% (57/70); and CT, 42.9% (30/70). For both early gastric cancer (EGC) and advanced gastric cancer (AGC), PET-CT was more accurate than CT in detecting the lesions. As the size of the tumor exceeded 3 cm, the detection rate increased. The sensitivities, specificities, PPV, and NPV of PET-CT for lymph node staging were 55.6%, 81%, 86.2%, and 45.9%, while the sensitivities, specificities, PPV, and NPV of CT were 40.0%, 85.7%, 85.7% and 40%, respectively. One case of multiple liver metastasis and two cases of dual primary cancer (rectal and pancreatic cancers) were detected by PET-CT. PET-CT also had a higher detection rate for all histologic types of primary tumors. PET-CT was more accurate than CT in detecting primary gastric cancer lesions. The detection of nodal metastasis by PET-CT was similar to CT; small-sized tumors or EGC detection rates were not high. However, PET-CT provided additional information to detect distant metastases and dual primary cancers and reduced unnecessary laparotomies to detect peritoneal seeding or carcinomatosis. Conclusion: It would be useful to make a pre-operative diagnosis of gastric cancer and determine treatment if PET-CT were added to other routine pre-operative studies.

  • PDF