• Title/Summary/Keyword: Imaging Module

Search Result 130, Processing Time 0.025 seconds

3DentAI: U-Nets for 3D Oral Structure Reconstruction from Panoramic X-rays (3DentAI: 파노라마 X-ray로부터 3차원 구강구조 복원을 위한 U-Nets)

  • Anusree P.Sunilkumar;Seong Yong Moon;Wonsang You
    • The Transactions of the Korea Information Processing Society
    • /
    • v.13 no.7
    • /
    • pp.326-334
    • /
    • 2024
  • Extra-oral imaging techniques such as Panoramic X-rays (PXs) and Cone Beam Computed Tomography (CBCT) are the most preferred imaging modalities in dental clinics owing to its patient convenience during imaging as well as their ability to visualize entire teeth information. PXs are preferred for routine clinical treatments and CBCTs for complex surgeries and implant treatments. However, PXs are limited by the lack of third dimensional spatial information whereas CBCTs inflict high radiation exposure to patient. When a PX is already available, it is beneficial to reconstruct the 3D oral structure from the PX to avoid further expenses and radiation dose. In this paper, we propose 3DentAI - an U-Net based deep learning framework for 3D reconstruction of oral structure from a PX image. Our framework consists of three module - a reconstruction module based on attention U-Net for estimating depth from a PX image, a realignment module for aligning the predicted flattened volume to the shape of jaw using a predefined focal trough and ray data, and lastly a refinement module based on 3D U-Net for interpolating the missing information to obtain a smooth representation of oral cavity. Synthetic PXs obtained from CBCT by ray tracing and rendering were used to train the networks without the need of paired PX and CBCT datasets. Our method, trained and tested on a diverse datasets of 600 patients, achieved superior performance to GAN-based models even with low computational complexity.

Fabrication of the Imaging Lens for Mobile Camera using Embossing Method (엠보싱 공법에 의한 카메라 모듈용 광학렌즈 성형기법에 대한 연구)

  • Lee, C.H.;Jin, Y.S.;Noh, J.E.;Kim, S.H.;Jang, I.C.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2007.05a
    • /
    • pp.79-83
    • /
    • 2007
  • We have developed a compact and cost-effective camera module on the basis of wafer-scale replication technology. A multiple-layered structure of several aspheric lenses in a mobile camera module is first assembled by bonding multiple glass-wafers on which 2-dimensional replica arrays of identical aspheric lenses are UV-embossed, followed by dicing the stacked wafers and packaging them with image sensor chips. We have demonstrated a VGA camera module fabricated by the wafer-scale replication processing with various UV-curable polymers having refractive indices between 1.4 and 1.6, and with three different glass-wafers of which both surfaces are embossed as aspheric lenses having 200 um sag-height and aspheric-coefficients of lens polynomials up to tenth-order. We have found that precise compensation in material shrinkage of the polymer materials is one of the most technical challenges, in order to achieve a higher resolution in wafer-scaled lenses for mobile camera modules.

  • PDF

Development of an Infrared Imaging-Based Illegal Camera Detection Sensor Module in Android Environments (안드로이드 환경에서의 적외선 영상 기반 불법 촬영 카메라 탐지 센서 모듈 개발)

  • Kim, Moonnyeon;Lee, Hyungman;Hong, Sungmin;Kim, Sungyoung
    • Journal of Sensor Science and Technology
    • /
    • v.31 no.2
    • /
    • pp.131-137
    • /
    • 2022
  • Crimes related to illegal cameras are steadily increasing and causing social problems. Owing to the development of camera technology, the miniaturization and high performance of illegal cameras have caused anxiety among many people. This study is for detecting hidden cameras effectively such that they could not be easily detected by human eyes. An image sensor-based module with 940 nm wavelength infrared detection technology was developed, and an image processing algorithm was developed to selectively detect illegal cameras. Based on the Android smartphone environment, image processing technology was applied to an image acquired from an infrared camera, and a detection sensor module that is less sensitive to ambient brightness noise was studied. Experiments and optimization studies were conducted according to the Gaussian blur size, adaptive threshold size, and detection distance. The performance of the infrared image-based illegal camera detection sensor module was excellent. This is expected to contribute to the prevention of crimes related to illegal cameras.

Implementation of BSCT $320{\times}240$ IR-FPA for Uncooled Thermal Imaging System (비냉각 열 영상 시트템용 BSCT $320{\times}240$ IR-FPA의 구현)

  • Kang, Dae-Seok;Shin, Gyeong-Uk;Park, Jae-U;Yoon, Dong-Han;Song, Seong-Hae;Han, Myeong-Su
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.39 no.11
    • /
    • pp.7-13
    • /
    • 2002
  • BSCT 320${\times}$240 IRFPA detector module is implemented, which is a key component in uncooled thermal imaging systems. The detector module consists of two parts, infrared sensitive pixel array and read-out integrated circuit(ROIC). The BSCT 320${\times}$240 pixels are made by laser scribe process and 10-${\mu}m$ micro-bump to satisfy 50-${\mu}m$ pitch and 95-% fill-factor. The ROIC has been designed to electrically address the pixels sequentailly and to improve signal-to-noise ratio with single transistor amplifier, HPF, tunable LPF and clamp circuit. The fabricated hybrid chip of detector and ROIC has been mounted on the TEC built-in ceramic package for more stable operation and tested for lots of electrical and optical properties. The IRFA sample has shown successful properties and met with good results of fill-factor, detectivity and responsivity.

Spaceborne Data Link Design for High Rate Radar Imaging Data Transmission (고속 레이다 영상자료 전송을 위한 위성탑재 데이터 링크 설계)

  • Gwak, Yeong-Gil
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.39 no.3
    • /
    • pp.117-124
    • /
    • 2002
  • A high speed data link capability is one of the critical factors in determining the performance of the spaceborne SAR system with high resolution because of the strict requirement for the real-time data transmission of the massive SAR data in a limited time of mission. In this paper, based on the data link model characterized by the spaceborne small SAR system, the high rate multi-channel data link module is designed including link storage, link processor, transmitter, and wide-angle antenna. The design results are presented with the performance analysis on the data link budget as well as the multi-mode data rate in association with the SAR imaging mode of operation from high resolution to the wide swath. The designed data link module can be effectively used for the spaceborne and airborne applications which requires to expand the high speed data link capability.

Automated radiochemical synthesis of [18F]FET on TRACERlab FX2N module and its quality control

  • Dong Hyun Kim;Eun-bi Shin;Iljung Lee;Heejung Kim;Kyo Chul Lee;Kyeong Min Kim;Joo Hyun Kang;Sang Moo Lim
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.7 no.2
    • /
    • pp.147-152
    • /
    • 2021
  • C-11 Radiolabeled amino acid-based radiopharmaceuticals such as [11C]MET for brain tumor PET imaging have limitations due to their short half-life (20 min). F-18 radiolabeled amino acid derivatives have been developed to overcome for the short half-life, one of which is [18F]FET. Brain tumor imaging using [18F]FET showed high uptake in tumor region and no non-specific uptake in inflammatory tissue, which was useful in discriminating the difference between inflammation and tumor especially. In this study, [18F]FET was synthesized using an automatic synthesis module and quality tests were carried out including enantiomeric purity analysis with reference compounds. Radiochemical yield was 50.3 ± 4.9% (n=7, decay-corrected) with molar activity of 76 ± 17 GBq/mmol. The radiochemical purity of >99%. Enantiomeric purity of [18F]FET using chiral HPLC analysis showed >99%, which was confirmed by co-injection with the L-FET and D-FET authentic standards. [18F]FET was prepared with high radiochemical yield and molar activity including no racemate mixture.

Design of Two Zoom Infrared Camels using Noise Uniformity Correction by Shutter Lens (셔터렌즈에 의한 검출기 불균일 보정을 적용한 이중배율 적외선 카메라 설계)

  • Ahn, Gyou-Bong;Kim, Seo-Hyun;Jung, Jae-Chul;Jo, Mun-Shin;Kim, Chang-Woo;Kim, Hyun-Sook
    • Korean Journal of Optics and Photonics
    • /
    • v.18 no.2
    • /
    • pp.135-141
    • /
    • 2007
  • This paper describes the design technology for a third generation thermal imaging system, which is more compact than before, using a $320\times240$ mid-IR focal plane detector. The third generation non-scanning thermal imaging system was constructed as a compact thermal imaging module as a reconnaissance, surveillance and navigation sensor for helicopter and infantry vehicles in the $1980's\sim1990's$ and now, we designed a new compact infrared camera and studied a new type of non-uniformity correction lens fer this camera.

An Ultrasonic Vessel-Pattern Imaging Algorithm with Low Computational Complexity (낮은 연산 복잡도를 지니는 초음파 혈관 패턴 영상 알고리즘)

  • Um, Ji-Yong
    • Journal of IKEEE
    • /
    • v.26 no.1
    • /
    • pp.27-35
    • /
    • 2022
  • This paper proposes an ultrasound vessel-pattern imaging algorithm with low computational complexity. The proposed imaging algorithm reconstructs blood-vessel patterns by only detecting blood flow, and can be applied to a real-time signal processing hardware that extracts an ultrasonic finger-vessel pattern. Unlike a blood-flow imaging mode of typical ultrasound medical imaging device, the proposed imaging algorithm only reconstructs a presence of blood flow as an image. That is, since the proposed algorithm does not use an I/Q demodulation and detects a presence of blood flow by accumulating an absolute value of the clutter-filter output, a structure of the algorithm is relatively simple. To verify a complexity of the proposed algorithm, a simulation model for finger vessel was implemented using Field-II program. Through the behavioral simulation, it was confirmed that the processing time of the proposed algorithm is around 54 times less than that of the typical color-flow mode. Considering the required main building blocks and the amount of computation, the proposed algorithm is simple to implement in hardware such as an FPGA and an ASIC.

Development of Optical Molecular Imaging System for the Acquisition of Bioluminescence Signals from Small Animals (소동물 발광영상 측정을 위한 광학분자영상기기의 개발)

  • Lee, Byeong-Il;Kim, Hyeon-Sik;Jeong, Hye-Jin;Lee, Hyung-Jae;Moon, Seung-Min;Kwon, Seung-Young;Choi, Eun-Seo;Jeong, Shin-Young;Bom, Hee-Seung;Min, Jung-Joon
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.4
    • /
    • pp.344-351
    • /
    • 2009
  • Purpose: Optical imaging is providing great advance and improvement in genetic and molecular imaging of animals and humans. Optical imaging system consists of optical imaging devices, which carry out major function for monitoring, tracing, and imaging in most of molecular in-vivo researches. In bio-luminescent imaging, small animals containing luciferase gene locally irradiate light, and emitted photons transmitted through skin of the small animals are imaged by using a high sensitive charged coupled device (CCD) camera. In this paper, we introduced optical imaging system for the image acquisition of bio-luminescent signals emitted from small animals. Materials and Methods: In the system, Nikon lens and four LED light sources were mounted at the inside of a dark box. A cooled CCD camera equipped with a control module was used. Results: We tested the performance of the optical imaging system using effendorf tube and light emitting bacteria which injected intravenously into CT26 tumor bearing nude mouse. The performance of implemented optical imaging system for bio-luminescence imaging was demonstrated and the feasibility of the system in small animal imaging application was proved. Conclusion: We anticipate this system could be a useful tool for the molecular imaging of small animals adaptable for various experimental conditions in future.

Implementation of ATE to Maintain Pre-Amplifier of Thermal Imaging System (열상장비 전단증폭부 정비용 ATE의 구현)

  • Park, Jai-Hyo;Kim, Han-Kyung
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.49 no.1
    • /
    • pp.80-87
    • /
    • 2012
  • We have developed the ATE(Automatic Test Equipment) system for the performance test of pre-amplifier of thermal imaging devices. The device regenerates the electronic signals of photon detection module which is normally in weak energy, for the image signals processing. Previous ATE system was primarily and actively developed in the field of semiconductor devices quality parts inspection. Recently, it has been studied in the field of performance testing of equipment. In the field of thermal performance test equipment, however, it lacks the study of ATE compared to other areas, which causes the maintenance related to the core of military thermal imaging system maintenance to be limited. In this paper, a new study of ATE in the field of thermal imaging system is done. It is designed to be used universally for the ATE system with different types of circuit card of thermal imaging system by adopting matrix relays. Using the developed ATE measuring the pre-amplifier amplitude, an average amplified amplitude of 2.71Vpp was measured which confirms that it is within the range of theoretical analysis and also verifies the good performance of the developed ATE.