• Title/Summary/Keyword: Images of Seoul

Search Result 2,048, Processing Time 0.038 seconds

Effect of Patient Size on Image Quality and Dose Reduction after Added Filtration in Digital Chest Tomosynthesis (부가필터를 적용한 디지털 흉부단층합성검사에서 환자 체형에 따른 화질 평가와 선량감소 효과)

  • Bok, Geun-Seong;Kim, Sang-Hyun
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.1
    • /
    • pp.23-30
    • /
    • 2018
  • To evaluate the effect of patient size on effective dose and image quality for Digital Chest Tomosynthesis(DTS) using additional 0.3 mm copper filtration. Eighty artificial nodules were placed in the thorax phantom("Lungman," Kyoto Kagaku, Japan), and Digital Chest Tomosynthesis(DTS) images of the phantom were acquired both with and without added 0.3 mm Cu filtration. To simulate patients of three sizes: small, average size and oversize, one or two 20-mm-thick layer of PMMA(polymethyl methacrylatek) blocks were placed on the phantom. The Effective dose was calculated using Monte Carlo simulations. Two evaluations of image quality methods have been employed. Three readers counted the number of nodules detected in the lung, and the measured contrast-to-noise ratios(CNRs) were used. Data were analyzed statistically. The ED reduced $26{\mu}Sv$ in a phantom, $33{\mu}Sv$ in one 20-mm-thick layer of PMMA block placed on the phantom, and $48{\mu}Sv$ in two 20-mm-thick layer of PMMA blocks placed on the phantom. The Effective dose(ED) differences between DTS with and without filtration were significant(p<0.05). In particular, when we used two 20-mm-thick layer of PMMA blocks placed on the phantom, the ED was significantly reduced by 36% compared with those without additional filtration. Nodule detection sensitivities were not different between with and without added filtration. Differences of CNRs were statistically insignificant(p>0.05). Use of additional filtration allows a considerable dose reduction during Digital Chest Tomosynthesis(DTS) without loss of image quality. In particular, additional filtration showed outstanding result for effective dose reduction on two 20-mm-thick layer of PMMA blocks placed on the phantom. It applies to overweight patients.

Analysis of masseter muscle in facial asymmetry before and after orthognathic surgery using 3-dimensional computed tomography (3차원 전산화 단층 사진을 이용한 안면비대칭 환자의 악교정 수술 전, 후 교근 분석)

  • Seo, Seung-Ah;Baik, Hyoung-Seon;Hwang, Chung-Ju;Yu, Hyung-Seog
    • The korean journal of orthodontics
    • /
    • v.39 no.1
    • /
    • pp.18-27
    • /
    • 2009
  • Objective: The purpose of this study was to understand the differences in masseter muscle(MM) between the shifted and non-shifted sides in facial asymmetry patients, and the changes shown by MM after mandibular surgery. Methods: Pre- and post-operative CT scans were performed on 12 Class III patients with facial asymmetry who were treated by intraoral vertical ramus osteotomy and 10 subjects with normal occlusion. Using the V-works 4.0 program(Cybermed, Seoul, Korea), 3-dimensional images of the mandible, and MM were reconstructed, and evaluated. Results: In the asymmetry group, the MM angle between the shifted and non-shifted sides was only significantly different(p<0.05). Compared with normal occlusion, the asymmetry group showed a significantly smaller volume and maximum cross-sectional area in both sides of MM(p<0.05). After mandibular surgery, the angle of MM(p<0.01) and differences in angle between the shifted and non-shifted sides of MM(p<0.05) were significantly decreased. The thickness in the maximum cross-sectional area was significantly increased(p<0.01). After surgery, MM in facial asymmetry patients was similarly changed to those in the normal occlusion group except for widths. Conclusions: MM in facial asymmetry was definitely different from those in normal occlusion. However, this study suggests that MM changed symmetrically in conjunction with the mandible after proper mandibular surgery.

Evaluation of TOF MR Angiography and Imaging for the Half Scan Factor of Cerebral Artery (유속신호증강효과의 자기공명혈관조영술을 이용한 뇌혈관검사에서 Half Scan Factor 적용한 영상 평가)

  • Choi, Young Jae;Kweon, Dae Cheol
    • Journal of the Korean Magnetics Society
    • /
    • v.26 no.3
    • /
    • pp.92-98
    • /
    • 2016
  • To aim of this study was to assess the full scan and half scan of imaging with half scan factor. Patients without a cerebral vascular disease (n = 30) and were subject to the full scan half scan, and set a region of interest in the cerebral artery from the three regions (C1, C2, C3) in the range of 7 to 8 mm. MIP (maximum intensity projection) to reconstruct the images in signal strength SNR (signal to noise ration), PSNR (peak signal noise to ratio), RMSE (root mean square error), MAE (mean absolute error) and calculated by paired t-test for use by statistics were analyzed. Scan time was half scan (4 minutes 53 seconds), the full scan (6 minutes 04 seconds). The mean measurement range (7.21 mm) of all the ROI in the brain blood vessel, was the SNR of the first C1 is completely scanned (58.66 dB), half-scan (62.10 dB), a positive correlation ($r^2=0.503$), for the second C2 SNR is completely scanned (70.30 dB), half-scan (74.67 dB) the amount of correlation ($r^2=0.575$), third C3 of a complete scan SNR (70.33 dB), half scan SNR (74.64 dB) in the amount of correlation between the It was analyzed with ($r^2=0.523$). Comparative full scan with half of SNR ($4.75{\pm}0.26dB$), PSNR ($21.87{\pm}0.28dB$), RMSE ($48.88{\pm}1.61$), was calculated as MAE ($25.56{\pm}2.2$). SNR is also applied to examine the half-scans are not many differences in the quality of the two scan methods were not statistically significant in the scan (p-value > .05) image takes less time than a full scan was used.

A Study on Commemoration Characteristics of Vietnam War Memorials in the United States of America (미국에 있는 베트남전쟁 메모리얼에 나타난 기념성)

  • Lee, Sang-Seok
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.43 no.1
    • /
    • pp.1-15
    • /
    • 2015
  • The purpose of this study was to analyze the commemoration characteristics of Vietnam War Memorials(VWM) in the United States(VWMUS). Through site survey and internet research, the researcher selected 87 VWMUS except monuments simply with markers, and analyzed 5 analysis items: design concepts, spatial characteristics, landscape details, sculptures, and interpretive texts and symbols. The results are as follows: 1. The analysis revealed that the main concepts of VWMUS were to cherish victims of the Vietnam War(85 sites (97.7%)), show veteran's dedication for country(85 sites(97.7%)), and publicize the contribution of groups by troop, regional, and membership(84 sites(96.6%)). 2. Most VWMUS were located in memorial parks and plazas. 59 memorials(67.8%) were designed to pursue the completion of each memorial assuming the form of symmetry and circles. On the other hand, 12 memorials(13.8%) were typed memorial walls and 11 memorials(12.6%) were formed by spatial sequence including various landscape details and grading. 3. Stone walls were mainly used to cherish victims of the War at 65 memorials(74.7%), and also, Flags like the Stars and Stripes, POW MIA flags, and state flags were hoisted to symbolize memorial's identity at all memorials. Additionally, Benches, monuments, markers, posts and columns, ponds and channels, Helicopters were partially introduced some memorials. 4. Sculptures were used 21 memorials(24.1%) which were smaller in numbers than other War Memorial in the U.S.A., for black stonewall were used for the main element of VWMUS. Except for a few sculptures that aimed to represent the Vietnam War symbolically and narratively, 16 memorials(18.4%) were formed to realistically express the image of wounded soldiers and their hardship in the Vietnam War. 5. KIA, MIA, Veteran's name were written and their images depicted on walls, Also, the symbolic phrase, 'ALL GAVE SOME, SOME GAVE ALL' and 'DUTY, HONOR, COUNTRY' were written on the memorials walls, and the POW MIA symbols were printed on the flags and engraved on walls. 6. In the United States of America, Democratic patriotism was considered a main ideological value in VWMUS by engraving KIA MIA's names on the walls, hoisting flags Stars and Stripes and POW MIA, and writing symbolic phrases 'ALL GAVE SOME, SOME GAVE ALL' and 'DUTY, HONOR, COUNTRY'. On the contrary, in Vietnam, nationalism, patriotism, and socialism were emphasized as main ideologies through raising war victory and resistance to foreign power as well as writing the symbolic phrase 'TO-QUOC-GUI-CONG' meaning 'our country remember your achievement' on memorial towers. Further study will be required to comparatively analyze VWM in order to understand national characteristics in Korea, Australia, U.S.A, and Vietnam.

The reliability of the cephalogram generated from cone-beam CT (Cone-beam CT로부터 제작된 측모 두부계측방사선사진의 정확도 평가)

  • Kang, Ji-Young;Kim, Kwang-Won;Lim, Sung-Hoon
    • The korean journal of orthodontics
    • /
    • v.37 no.6
    • /
    • pp.391-399
    • /
    • 2007
  • Three-dimensional approaches for the diagnosis and analysis of the dentofacial area are becoming more popular in accordance with the development of cone-beam CT (CBCT). The purposes of this study were to evaluate the reliability of cephalometric measurements of lateral cephalograms generated from a CBCT image by making comparisons with the traditional digital lateral cephalogram, and to evaluate the possibility of the clinical application of CBCT generated cephalogram images. Methods: Twenty patients whose external auditory meatus could be identified in the CBCT image were selected, and both CBCT and digital cephalograms were taken. Differences between the measurements of both cephalograms were tested by paired t-test. Results: Among the 22 measurements used, only U1-FH, Mx6 to PTV, and maxillomandibular difference showed statistically significant differences between the CBCT generated cephalogram and the digital cephalogram. Conclusions: The results suggest that the CBCT generated cephalogram can be used for some cephalometric measurements not requiring porion, PTV, condylion as a landmark (SNA, SNB, U1 to SN, IMPA, interincisal angle, etc.).

The Evaluation of Image Correction Methods for SPECT/CT in Various Radioisotopes with Different Energy Levels (SPECT/CT에서 서로 다른 에너지의 방사성동위원소 사용시 영상보정기법의 유용성 평가)

  • Shin, Byung Ho;Kim, Seung Jeong;Yun, Seok Hwan;Kim, Tae Yeop;Lim, Jung Jin;Woo, Jae Ryong;Oh, So Won;Kim, Yu Kyeong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.53-58
    • /
    • 2013
  • Purpose: To optimize correction method for SPECT/CT, image quality consisting of resolution and contrast was evaluated using three radioisotopes ($^{99m}Tc$, $^{201}Tl$ and $^{131}I$) and three different correction methods; attenuation correction (AC), scatter correction (SC) and both attenuation and scatter correction (ACSC). Materials and Methods: Images were acquired with a SPECT/CT scanner and a conventional CT protocol with an OESM reconstruction algorithm (2 iterations and 10 subsets). For resolution measurement, fixed radioactivity (2.22 kBq) was infused into a spatial resolution phantom and full width at half maximum (FWHM) was measured using a vendor-provided software. For contrast evaluation, radioactive source with a ratio of 1:8 to background was filled in a Flanged Jaszczak phantom and percent contrast (%) were calculated. All the parameters for image quality were compared with non-correction (NC) method. Results: As compared with NC, image resolution of all three isotopes were significantly improved by AC and ACSC, not by SC. In particular, ACSC showed better resolution than AC alone for $^{99m}Tc$ and $^{201}Tl$. Image contrast of all three radioisotopes in a sphere with the largest diameter were enhanced by all correction methods. ACSC showed the highest contrast in all three radioisotopes, which was the most accurate in $^{99m}Tc$ (85.9%). Conclusion: Image quality of SPECT/CT was improved in all the radioisotopes by CT-based attenuation correction methods, except SC alone. SC failed to improve resolution in any radioisotopes, but it was effective in contrast enhancement. ACSC would be the best correction method as it improved resolution in radioisotopes with low energy levels and contrast in radioisotope with low energy levels. However, in radioisotope with high energy level, AC would be better than ACSC for resolution improvement.

  • PDF

Process development of a virally-safe dental xenograft material from porcine bones (바이러스 안전성이 보증된 돼지유래 골 이식재 제조 공정 개발)

  • Kim, Dong-Myong;Kang, Ho-Chang;Cha, Hyung-Joon;Bae, Jung Eun;Kim, In Seop
    • Korean Journal of Microbiology
    • /
    • v.52 no.2
    • /
    • pp.140-147
    • /
    • 2016
  • A process for manufacturing virally-safe porcine bone hydroxyapatite (HA) has been developed to serve as advanced xenograft material for dental applications. Porcine bone pieces were defatted with successive treatments of 30% hydrogen peroxide and 80% ethyl alcohol. The defatted porcine bone pieces were heat-treated in an oxygen atmosphere box furnace at $1,300^{\circ}C$ to remove collagen and organic compounds. The bone pieces were ground with a grinder and then the bone powder was sterilized by gamma irradiation. Morphological characteristics such as SEM (Scanning Electron Microscopy) and TEM (Transmission Electron Microscopy) images of the resulting porcine bone HA (THE Graft$^{(R)}$) were similar to those of a commercial bovine bone HA (Bio-Oss$^{(R)}$). In order to evaluate the efficacy of $1,300^{\circ}C$ heat treatment and gamma irradiation at a dose of 25 kGy for the inactivation of porcine viruses during the manufacture of porcine bone HA, a variety of experimental porcine viruses including transmissible gastroenteritis virus (TGEV), pseudorabies virus (PRV), porcine rotavirus (PRoV), and porcine parvovirus (PPV) were chosen. TGEV, PRV, PRoV, and PPV were completely inactivated to undetectable levels during the $1,300^{\circ}C$ heat treatment. The mean log reduction factors achieved were $${\geq_-}4.65$$ for TGEV, $${\geq_-}5.81$$ for PRV, $${\geq_-}6.28$$ for PRoV, and $${\geq_-}5.21$$ for PPV. Gamma irradiation was also very effective at inactivating the viruses. TGEV, PRV, PRoV, and PPV were completely inactivated to undetectable levels during the gamma irradiation. The mean log reduction factors achieved were $${\geq_-}4.65$$ for TGEV, $${\geq_-}5.87$$ for PRV, $${\geq_-}6.05$$ for PRoV, and $${\geq_-}4.89$$ for PPV. The cumulative log reduction factors achieved using the two different virus inactivation processes were $${\geq_-}9.30$$ for TGEV, $${\geq_-}11.68$$ for PRV, $${\geq_-}12.33$$ for PRoV, and $${\geq_-}10.10$$ for PPV. These results indicate that the manufacturing process for porcine bone HA from porcine-bone material has sufficient virus-reducing capacity to achieve a high margin of virus safety.

Prevalence of Intimal Defect in the Patients urith Surgically Treated Acute Type A Intramural Hematoma of the Aorta (외과적으로 치료한 급성 A형 대동맥벽내 혈종 환자에서 대동맥 내막 결손의 존재 빈도)

  • Park, Kay-Hyun
    • Journal of Chest Surgery
    • /
    • v.40 no.11
    • /
    • pp.733-744
    • /
    • 2007
  • Background: There is a controversy regarding the pathogenesis and management principle of an acute intramural hematoma (IMH) of the aorta, Recent studies have reported intimal defects in many patients diagnosed with IMH, and suggested that intimal defects play important roles in the pathogenesis, progression of the pathology, and prognosis. Material and Method: This study reviewed the preoperative and postoperative computed tomography (CT) scan images of 36 patients who underwent surgical treatment for Stanford type A acute IMH of the aorta. The surgical findings were also reviewed retrospectively from the medical records. Result: In 15 patients (41.7%), the findings suggestive of the intimal defects were found in the preoperative CT. During the operation, 20 patients (72.2%) were found to have small intimal defects in the ascending aorta or the arch, of which 13 patients (50.5%) did not have the CT findings suggestive of intimal defects. In 17 patients, the intimal defects were located in the aortic arch or distal ascending aorta, where a gross examination would have been impossible without total circulatory arrest. In all patients, the intimal defects identified were included in the resected aortic segment, or locally closed. Follow-up CT at 4 months or longer after surgery showed that the IMH in the descending aorta had disappeared or was markedly improved. Conclusion: Most patients undergoing surgical treatment for acute type A IMH had intimal defects. This suggests that a large proportion of IMH might have a similar pathogenic mechanism as classic dissection. Consequently, it is believed that those two entities of acute aortic syndrome should be treat-ed using the same principles.

Estimation of Near Surface Air Temperature Using MODIS Land Surface Temperature Data and Geostatistics (MODIS 지표면 온도 자료와 지구통계기법을 이용한 지상 기온 추정)

  • Shin, HyuSeok;Chang, Eunmi;Hong, Sungwook
    • Spatial Information Research
    • /
    • v.22 no.1
    • /
    • pp.55-63
    • /
    • 2014
  • Near surface air temperature data which are one of the essential factors in hydrology, meteorology and climatology, have drawn a substantial amount of attention from various academic domains and societies. Meteorological observations, however, have high spatio-temporal constraints with the limits in the number and distribution over the earth surface. To overcome such limits, many studies have sought to estimate the near surface air temperature from satellite image data at a regional or continental scale with simple regression methods. Alternatively, we applied various Kriging methods such as ordinary Kriging, universal Kriging, Cokriging, Regression Kriging in search of an optimal estimation method based on near surface air temperature data observed from automatic weather stations (AWS) in South Korea throughout 2010 (365 days) and MODIS land surface temperature (LST) data (MOD11A1, 365 images). Due to high spatial heterogeneity, auxiliary data have been also analyzed such as land cover, DEM (digital elevation model) to consider factors that can affect near surface air temperature. Prior to the main estimation, we calculated root mean square error (RMSE) of temperature differences from the 365-days LST and AWS data by season and landcover. The results show that the coefficient of variation (CV) of RMSE by season is 0.86, but the equivalent value of CV by landcover is 0.00746. Seasonal differences between LST and AWS data were greater than that those by landcover. Seasonal RMSE was the lowest in winter (3.72). The results from a linear regression analysis for examining the relationship among AWS, LST, and auxiliary data show that the coefficient of determination was the highest in winter (0.818) but the lowest in summer (0.078), thereby indicating a significant level of seasonal variation. Based on these results, we utilized a variety of Kriging techniques to estimate the surface temperature. The results of cross-validation in each Kriging model show that the measure of model accuracy was 1.71, 1.71, 1.848, and 1.630 for universal Kriging, ordinary Kriging, cokriging, and regression Kriging, respectively. The estimates from regression Kriging thus proved to be the most accurate among the Kriging methods compared.

Evaluation of Standardized Uptake Value applying Prompt Gamma Correction on 68Ga-DOTATOC PET/CT Image (68Ga-DOTATOC PET/CT에서 Prompt Gamma Correction을 적용한 SUV의 평가)

  • Yoon, Seok Hwan
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.1
    • /
    • pp.1-7
    • /
    • 2018
  • $^{68}Ga$ was eluted from a $^{68}Ge/^{68}Ga$ radionuclide generator. $^{68}Ga$ decays into $^{68}Zn$, with a half life=67.8min. The decay is 88.9 % by ${\beta}$+ and 11.1 % by EC. The main ${\beta}$+ decay (87.7 %) is to the ground level of $^{68}Zn$ and it is a pure positron emission branch. A small fraction decays ${\beta}$+ (1.2 %) into an excited level of $^{68}Zn$, which promptly decays into the ground level with a ${\gamma}$ (1.077 Mev). This can constitute prompt gamma contamination in the PET data, if the 1.077 Mev ${\gamma}$ has a scatter interaction in the patient, and generates a lower energy ${\gamma}$ in coincidence with the positron annihilation pair. The purpose of this study was to evaluate standardized uptake value(SUV) before and after applying prompt gamma rays correction on $^{68}Ga$-DOTATOC PET/CT image. Fifty patient underwent PET/CT 1 hour after injection of the $^{68}Ga$-DOTATOC. The SUVmax and SUVmean of lesions and normal tissues (Pituitary, Lung, Liver, Spleen, Kidney, Intestine) were evaluated before and after applying prompt gamma correction on $^{68}Ga$-DOTATOC PET/CT image. Additionally, the SUVmax of each lesions and SUVmean of the soft tissues were measured on images. and target to background ratios (TBR) were calculated as quantitative indices. Among 15 patients, 25 of lesions (Pancreas, Liver, Thoracic Spine, Brain) with increased uptake on $^{68}Ga$-DOTATOC PET/CT image. SUVmax and SUVmean were increased in lesion site and normal tissue after prompt gamma rays correction. TBR was $51.51{\pm}49.28$ and $55.50{\pm}53.12$ before and after prompt gamma rays correction, respectively. (p<0.0001)