• Title/Summary/Keyword: Images of Law

Search Result 97, Processing Time 0.027 seconds

Images of Law and Reality in TV Legal Series: Focusing on (TV 법정 프로그램에 나타난 법 이미지와 현실구성: <실화극장-죄와 벌>을 중심으로)

  • Lee, Hee-Eun
    • Korean journal of communication and information
    • /
    • v.50
    • /
    • pp.121-142
    • /
    • 2010
  • Can law be combined with television entertainment programs? This paper explores the ways in which law systems and law culture are reflected in and reflect the television legal series. TV legal series, such as legal dramas and infotainment shows, provide platforms for the audiences, who otherwise have few opportunity in real life, to engage with legal systems in societies. Adopting loosely dramatized reality programs, these legal series not only entertain and inform audiences but also educate citizens. This paper combines analyses of theoretical debates on law and television with analysis of TV text. The result shows that , dramatized enactment based on true stories and criminal cases, may have an important ideological role in which fictionalized dramas mask the hard realities and authoritative legal systems. By doing so, TV legal shows play their roles not as mere symbolic representation but as powerful institutions that construct the image of law and reality.

  • PDF

Study on 3D Printer Producing of Assistive Devices for Vertical Incidence of Law Method (Law법 수직입사를 위한 보조기구의 3D 프린터 제작 연구)

  • Kim, Sang-Hyun
    • Journal of radiological science and technology
    • /
    • v.43 no.6
    • /
    • pp.489-494
    • /
    • 2020
  • The Law method is observing the temporal bone. There are two types of methods: the double angle method, which manipulates the center ray angle of the tube twice, and the single angle method, which manipulates once. The purpose is to increase the reproducibility of the image by making vertical incidence by making an assistive device using a 3D printer. Two assistive devices with a wedge-shaped 8.5 × 10 × 2.3 cm, an inclined surface of 7.5 cm, and an inclination angle of 15° were fabricated. Assistive devices can be combined with each other in the form of grooves, and PLA (Poly Lactic Acid) is used as a material. In the first experiment, 10 examiners operated the tube 15° in the caudad direction and 15° in the anterior direction, and measured it with a protractor to conduct a reproducibility experiment. Second, two examiners acquired vertically incidence images using the existing law method and assistive devices, and measured the distance between each measurement point to evaluate the reproducibility. The tube center ray angle reproducibility experiment was not statistically significant, but the angle difference was up to 9° between examiners. The reproducibility experiment of radiographic images was not statistically significant with the conventional method, and the method using an assistive device was statistically significant. Therefore, regardless of skill level, an image capable of securing reproducibility, which is the advantage of vertical incidence, could be obtained.

Evaluation of the Usefulness of Images according to the Use of the Field Size in Mastoid Process Radiography (유양돌기 방사선검사 시 조사야 사용법에 따른 영상의 유용성 평가)

  • Jung, Hong-Ryang
    • Journal of radiological science and technology
    • /
    • v.44 no.5
    • /
    • pp.435-441
    • /
    • 2021
  • The purpose of this study was to evaluate the quality of images and to quantitatively measure and analyze the dose of scattered ray to the organs, which were highly sensitive to radiation according to the use of cylinder cone in mastoid process radiography. When the cylinder cone was not used, the SID was 100cm and the field size was 24 × 36 cm(864 cm2). When using the cylinder cone which was a circle, the SID was 70 cm, the radius was 10.5 cm and field size was 86.59 cm2. As a result of the study, SNR of the image quality evaluation was measured to be 2.58 for Law method and 3.90 for Stenver's method when not using cylinder cone, and 2.87 for Law method and 14.67 for Stenver's method when using cylinder cone. CNR was measured to be 0.03 for Law method and 0.04 for Stenver's method when cylinder cone was not used, and 0.04 for Law method and 0.05 for Stenver's method when using cylinder cone. When the cylinder cone was not used, the scattered ray dose was measured to be 0.10 mGy in the right eyeball, 0.30 mGy in the left eyeball, 2.02 mGy in the parotid gland, and 0.29 mGy in the thyroid gland for Law method and to be 0.03 mGy in the right eyeball, 0.12 mGy in the left eyeball, 1.43 mGy in the parotid gland, and 0.09 mGy in the thyroid gland for Stenver's method. When the cylinder cone was used, the scattered ray dose was measured to be 0.05 mGy in the right eyeball, 0.03 mGy in the left eyeball and the parotid and thyroid gland were below the measurable values for Law method and all areas were below the measurable values for Stenver's method. This was found to be statistically significant(p<0.000).

The Study on image correction of geometric distortion in digital radiography image (방사선투과영상의 기하학적 왜곡 보정에 관한 연구)

  • Park, S.K.;Ahn, Y.S.;Gil, D.S.
    • Journal of Power System Engineering
    • /
    • v.15 no.4
    • /
    • pp.25-30
    • /
    • 2011
  • This study is made to provide with a method for correcting the geometric distortion of the digital radiography image by analytical approach based upon the inverse square law and Beer's law. This study is aimed to find out and improve a mathematic model of nonlinear type. Variations in the alignment of the X-ray source, the object, and imaging plate affect digital radiography images. A model which is expressed in parameter values; e.g, angle, position, absorption coefficient, length, width and pixel account of radiography source, is developed so as to match the sample image. For the best correction of the digital image that is the most similar to the model image, a correction technique based upon tangent is developed; then applied to the digital radiography images of steel tubes. As a result, the image correction is confirmed to be made successfully.

Image Recovery Using Nonlinear Modeling of Industrial Radiography (산업용방사선영상의 비선형모델링에 의한 영상복구)

  • Hwang, Jung-Won;Hwang, Jae-Ho
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.45 no.4
    • /
    • pp.71-77
    • /
    • 2008
  • This paper presents a methodology for recovering the industrial radiographic images from the effects of nonlinear distortion. Analytical approach based on the inverse square law and Beer's law is developed in order to improve a mathematic model of nonlinear type. The geometric effect due to dimensions of the radioactive source appeals on the digitized images. The relation that expresses parameters values(angle, position, absorption coefficient, length, width and pixel account) is defined in this model, matching with the sample image. To perform the search for image recovery most similar to the model, a correction procedure is designed. The application of this method on the radiographic images of steel tubes is shown and recovered results are discussed.

Study for Guideline of CD copy Issue to Secure Personal Information (개인정보 보호를 위한 의료영상 복사발급 지침에 대한 고찰)

  • Lee, Jong-Woong;Kang, Ji-Yeon;Kim, Eun-Jeong
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.10 no.2
    • /
    • pp.11-16
    • /
    • 2008
  • Images of medical treatment on PACS environment are digitized and they make saving and transmission of patient's information easy with CD format causing increase of patients transfer rate between hospital and data transmission as well. Figuring out the configuration of confining status of copied images of medical treatment with CD format and present the appropriate way of identification for personal information. 20 general hospital over 500 beds which are utilizing PACS currently. Questionnaire investigation focusing on PACS operation center and it's management people. In accordance with the law of securing personal information of public organizations, it says "Anyone who wants to see his or her information via representative he or she needs to make a letter of attorney and turn in this to the president of it's possessing facility" in the article 16. Based on the investigation of general hospital for CD copy issue status near metropolitan area, 8 out of 20, were issuing CD copy through personal identification process(the person oneself and representative) and 10 general hospital were doing by getting signature of receiptor only without identification of the person oneself and 2 general hospital confirmation process is not at all. By the law of securing personal information of public organization, article 16, confirmation process is supposed to mandate lawfully with a letter of attorney when there is any request of reading and/or copies of one's information. But in reality, there were no consistent rules on reading, the process and coverage of copy issue, rejection coverage of copy issue of CD copy in each general hospital PACS operation center. Therefore there is a big need for consolidated format which is applicable by law when the representative requests to issue of CD copy that is storing medical treatment images. By issue through this consolidated format, securing medical information of individual and systemic operation and management will be valid and effective.

  • PDF

Classification of Restaurant Table Settings with Gestalt's Law of Visual Perception (외식 상차림의 게슈탈트 시지각 법칙에 따른 분류)

  • Joo, Seon Hee;Han, Kyung Soo
    • Journal of the Korean Society of Food Culture
    • /
    • v.28 no.2
    • /
    • pp.177-185
    • /
    • 2013
  • This study analyzed restaurant table settings with Gestalt's law of visual perception to obtain basic data for future marketing strategies. The research uses methods that involve applying images of restaurant table settings to Gestalt's law of visual perception, doing content analysis, and conducting a frequency analysis as well as a Chi-square test for classification analysis by visual perception. Results show a significant difference in the laws of visual perception, especially in the laws of nearness and closure, between table settings of different countries and backgrounds, such as Korean, Japanese, Chinese, Western cultures. In terms of the law of nearness, Chinese dishes were low, while other countries' dishes and Korean dishes showed high figures. In terms of the law of closure, Japanese dishes and western dishes had low values, while other countries' dishes and Korean dishes were high in their closure. Further studies on consumer awareness by visual perception classification need to be conducted.

Experimental Examination of the Beer's law for Quantitative Electron Tomography (정량적 전자토모그래피를 위한 Beer's law의 실험적 검증)

  • Kim, Jin-Gyu;Song, Kyung;Lee, Su-Jeong;Jou, Hyeong-Tae;Kim, Youn-Joong
    • Applied Microscopy
    • /
    • v.40 no.2
    • /
    • pp.117-123
    • /
    • 2010
  • This study has examined experimentally the Beer's law which is a precondition for quantitative electron tomography. We used carbon support film and latex spheres, which have similar absorption coefficients with biological samples, as the test samples to take a tilt-series of images for electron tomography. First, the 3D information of carbon film and latex spheres was obtained by electron tomography. Then, the regression analysis on the relationship between the intensities of the incident and the transmitted beams in a tilt series was carried out to examine the Beer's law. The regression results with RMS error of 0.976 show the linear intensity variations of the transmitted beam as the tilt angles were increased. In addition, the relative absorption coefficients of carbon support film and latex spheres calculated experimentally through the Beer's law were 1.71 (5) and 2.67 (6)/${\mu}m$, respectively. The absorption coefficients remained constant within a full tilt range. Therefore, it is expected that quantitative electron tomography could be performed for biological samples by applying Beer's law provided the exact intensity of incident beam can be obtained under the thoroughly controlled experimental conditions.

A Study on the DCT Image Coding Considering Weber's law (웨버의 법칙을 고려한 DCT 영상 부호화에 관한 연구)

  • 이은국;김장복
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.18 no.5
    • /
    • pp.663-674
    • /
    • 1993
  • In this paper, a DCT image coding algorithm using the human visual property is proposed. Human visual is relatively sensitive to noise in the darker region, insensitive to noise in the brighter region. This property was proved by Weber's law through psycovisual experiment. Weber's law states that the just noticeable difference (j.n.d.) is proportional to intensity. Therefore, the implication of this observation for image processing is that reducing noise in the darker region is more important than reducing noise in the brighter region. In this proposed coding scheme AC coefficients in the darker region are more finely quantized than those in the brighter region. Results showed that, at low bit rate, the subjective quality of reconstructed images by proposed coding scheme is improved than that of coding scheme without considering human visual property.

  • PDF

Comparison of CME mean density based on a full ice-cream cone structure and its corresponding ICME one

  • Na, Hyeonock;Moon, Yong-Jae
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.43 no.1
    • /
    • pp.54.1-54.1
    • /
    • 2018
  • For space weather forecast, it is important to determine three-dimensional parameters of coronal mass ejections (CMEs). To estimate three-dimensional parameters of CMEs, we have developed a full ice-cream cone model which is a combination of a symmetrical flat cone and a hemisphere. By applying this model to 12 SOHO/LASCO halo CMEs, we find that three-dimensional parameters from our method are similar to those from other stereoscopic methods. For several geoeffective CME events, we determine CME mass by applying the Solarsoft procedure (e.g., cme_mass.pro) to SOHO/LASCO C3 images. CME volumes are estimated from the full ice-cream cone structure. We derive CME mean density as a function of CME height for these CMEs, which are approximately fitted to power-law functions. We find that the ICME mean densities extrapolated from the power law functions, are correlated with their corresponding ICME ones in logarithmic scales.

  • PDF