• Title/Summary/Keyword: Image-based Scanning

Search Result 286, Processing Time 0.033 seconds

The Precise Three Dimensional Phenomenon Modeling of the Cultural Heritage based on UAS Imagery (UAS 영상기반 문화유산물의 정밀 3차원 현상 모델링)

  • Lee, Yong-Chang;Kang, Joon-Oh
    • Journal of Cadastre & Land InformatiX
    • /
    • v.49 no.1
    • /
    • pp.85-101
    • /
    • 2019
  • Recently, thank to the popularization of light-weight drone through the significant developments in computer technologies as well as the advanced automated procedures in photogrammetry, Unmanned Aircraft Systems have led to a growing interest in industry as a whole. Documentation, maintenance, and restoration projects of large scaled cultural property would required accurate 3D phenomenon modeling and efficient visual inspection methods. The object of this study verify on the accuracies achieved of 3D phenomenon reconstruction as well as on the validity of the preservation, maintenance and restoration of large scaled cultural property by UAS photogrammetry. The test object is cltural heritage(treasure 1324) that is the rock-carved standing Bodhisattva in Soraesan Mountain, Siheung, documented in Goryeo Period(918-1392). This standing Bodhisattva has of particular interests since it's size is largest stone Buddha carved in a rock wall and is wearing a lotus shaped crown that is decorated with arabesque patterns. The positioning accuracy of UAS photogrammetry were compared with non-target total station survey results on the check points after creating 3D phenomenal models in real world coordinates system from photos, and also the quantified informations documented by Culture Heritage Administration were compared with UAS on the bodhisattva image of thin lines. Especially, tests the validity of UAS photogrammetry as a alternative method of visual inspection methods. In particular, we examined the effectiveness of the two techniques as well as the relative fluctuation of rock surface for about 2 years through superposition analysis of 3D points cloud models produced by both UAS image analysis and ground laser scanning techniques. Comparison studies and experimental results prove the accuracy and efficient of UAS photogrammetry in 3D phenomenon modeling, maintenance and restoration for various large-sized Cultural Heritage.

A Study of Image Quality Improvement Through Changes in Posture and Kernel Value in Neck CT Scanning (경부 CT검사 시 Kernel 값과 검사자세 변화를 통한 화질개선에 관한 연구)

  • Kim, Hyeon-Ju;Chung, Woo-Jun;Cho, Jae-Hwan
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.2
    • /
    • pp.59-66
    • /
    • 2011
  • There is a difficulty because of classifying the anatomical structure in the neck CT scan by the beam hardening artifact no more than disease and it including the 6, 7 number cervical spine and intervertebral disk. In case of enforcing the neck CT scan cause of the inner diameter of beam artifact tried to be inquired by the image evaluation according to the change of the image evaluation according to the direction of the shoulder joint applying the variation method of a posture and location and Kernel value and it was most appropriate, the lion tax and Kernel value try to be searched for through an experiment. Somatom Sensation 16 (Siemens, Enlarge, Germany) equipment was used in a patient 30 people coming to the hospital for the neck CT scan. A workstation used the AW 4.4 version (GE, USA). According to a direction and location of the shoulder joint, the patient posture gave a change to the direction of the shoulder joint as the group S it gave a change as three postures and placed the both arms comfortably and helps a group N and augmented unipolar left in the wealthy merchant and group P it memorized the both hands and ordered the eversion and drops below to the utmost and enforced a scan. By using a reconstructing method as the second opinion, it gave and reconstructed the Kernel value a change based on scan data with B 10 (very smooth), B 20 (smooth), B 30 (medium smooth), B 40 (medium), B 50 (medium sharp), B 60 (sharp), and B 70 (very sharp). By using image data which gave the change of the examination posture and change of the Kernel value and are obtained, we analyzed through the noise value measurement and image evaluation of. The outside wire eversion orders the both hands and the examination posture is cost in the neck CT scan with the group P it drops below to the utmost. And in case of when reconstructing with B 40 (medium) or B 50 (medium sharp) being most analyzed into the inappropriate posture and Kernel value and applying the Kernel value to a clinical, it is considered to be very useful.

Characterization of the a-Se Film for Phosphor based X-ray light Modulator (형광체 기반 X선 광 변조기를 위한 비정질 셀레늄 필름 특성)

  • Kang, Sang-Sik;Park, Ji-Koon;Cho, Sung-Ho;Cha, Byung-Youl;Shin, Jung-Wook;Lee, Kun-Hwan;Mun, Chi-Woong;Nam, Sang-Hee
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.2
    • /
    • pp.306-309
    • /
    • 2007
  • PXLM(Phosphor based x-ray light modulator) has a combined structure by phosphor, photoconductor, and liquid crystal and it can realize x-ray image of high resolution in clinical diagnosis area. In this study, we fabricated a photoconductor and investigated electrical and optical properties to confirm application possibility of radiator detector of PXLM structure. As photoconductor, amorphous selenium(a-Se), which is used most in DR(Digital radiography) of direct conversion method, was used and for formation of thin film, it was formed as $20{\mu}m-thick$ by using thermal vacuum evaporation system. For a produced a-Se film, through XRD(X-ray diffraction) and SEM(Scanning electron microscope), we investigated that amorphous structure was uniformly established and through optical measurement, for visible light of 40 $0\sim630nm$, it had absorption efficiency of 95 % and more. After fabricated a-Se film on the top of ITP substrate, hybrid structure was manufactured through forming $Gd_2O_3:Eu$ phosphor of $270{\mu}m-thick$ on the bottom of the substrate. As the result to confirm electrical property of the manufactured hybrid structure, in the case of appling $10V/{\mu}m$, leakage current of $2.5nA/cm^2$ and x-ray sensitivity of $7.31nC/cm^2/mR$ were investigated. Finally, we manufactured PXLM structure combined with hybrid structure and liquid crystal cell of TN(Twisted nematic) mode and then, investigated T-V(Transmission vs. voltage) curve of external light source for induced x-ray energy. PXLM structure showed a similar optical response with T-V curve that common TN mode liquid crystal cell showed according to electric field increase and in appling $50\sim100V$, it showed linear transmission efficiency of $12\sim18%$. This result suggested an application possibility of PXLM structure as radiation detector.

Assessing the Positioning Accuracy of High density Point Clouds produced from Rotary Wing Quadrocopter Unmanned Aerial System based Imagery (회전익 UAS 영상기반 고밀도 측점자료의 위치 정확도 평가)

  • Lee, Yong Chang
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.23 no.2
    • /
    • pp.39-48
    • /
    • 2015
  • Lately, Unmanned Aerial Vehicles(UAV), Unmanned Aerial Systems(UAS) or also often known as drones, as a data acquisition platform and as a measurement instrument are becoming attractive for many photogrammetric surveying applications, especially generation of the high density point clouds(HDPC). This paper presents the performance evaluation of a low-cost rotary wing quadrocopter UAS for generation of the HDPC in a test bed environment. Its performance was assessed by comparing the coordinates of UAS based HDPC to the results of Network RTK GNSS surveying with 62 ground check points. The results indicate that the position RMSE of the check points are ${\sigma}_H={\pm}0.102m$ in Horizonatal plane, and ${\sigma}_V={\pm}0.209m$ in vertical, and the maxium deviation of Elevation was 0.570m within block area of ortho-photo mosaic. Therefore the required level of accuracy at NGII for production of ortho-images mosaic at a scale of 1:1000 was reached, UAS based imagery was found to make use of it to update scale 1:1000 map. And also, since this results are less than or equal to the required level in working rule agreement for airborne laser scanning surveying of NGII for Digital Elevation Model generation of grids $1m{\times}1m$ and 1:1000 scale, could be applied with production of topographic map and ortho-image mosaic at a scale of 1:1000~1:2500 over small-scale areas.

The Effect of Children's Beverages on Degradation of Dental Resin-Based Pit and Fissure Sealant (어린이 음료가 레진계 치면열구전색제의 화학적 분해에 미치는 영향)

  • Min, Hee-Hong;Kim, Hyun-Jin;Lee, Hye-Jin
    • Journal of dental hygiene science
    • /
    • v.18 no.6
    • /
    • pp.367-373
    • /
    • 2018
  • The consumption of beverages among children is rising. The purpose of this study was to examine the effect of kid's drink on dental resin-based pit and fissure sealant. Pororo, I-kicker, Sunkist kids were included in the experimental groups, and Samdasu was included in the control group. A conventional dental sealant material ($Clinpro^{TM}Sealant^{(R)}$) was selected for this study. Resin specimens (8 mm in diameter and 1 mm in thickness) were prepared according to manufacturers' instructions and the initial roughness (Ra) was then measured. The pH of all the four groups was measured using a pH meter. The specimens were individually immersed in 5 ml of the experimental solutions and stored at $37^{\circ}C$ for 72 hours. Following this, the surface roughness of the resin specimens was measured by Surftest. The concentration of residual monomer released was determined by high performance liquid chromatography (HPLC). The surface morphology of the resin specimen was evaluated before and after storage by scanning electron microscopy (SEM). Data were statistically analyzed using Kruskal-Wallis and Duncan's test. The results showed that all the children's beverages examined in this study contained citric acid. The pH of I-kicker was the lowest ($3.03{\pm}0.01$), followed by that of Sunkist kids ($3.26{\pm}0.02$) and Pororo ($3.47{\pm}0.02$). We observed an increase in the surface roughness of resin specimens after 72 h of immersion in all the beverages tested (p<0.05). There was matrix degradation after immersion, visualized on SEM image, in all the beverage groups. Bisphenol-A-glycidyl methacrylate was not detected after 72 hours, but triethylene glycol dimethacrylate levels were increased in all the beverages tested during the 72 hours by HPLC. These results suggest that intake of beverages containing acid can cause degradation of the resin-based pit and fissure sealants in children.

Micro-CT System for Small Animal Imaging (소동물영상을 위한 마이크로 컴퓨터단층촬영장치)

  • Nam, Ki-Yong;Kim, Kyong-Woo;Kim, Jae-Hee;Son, Hyun-Hwa;Ryu, Jeong-Hyun;Kang, Seoung-Hoon;Chon, Kwon-Su;Park, Seong-Hoon;Yoon, Kwon-Ha
    • Progress in Medical Physics
    • /
    • v.19 no.2
    • /
    • pp.102-112
    • /
    • 2008
  • We developed a high-resolution micro-CT system based on rotational gantry and flat-panel detector for live mouse imaging. This system is composed primarily of an x-ray source with micro-focal spot size, a CMOS (complementary metal oxide semiconductor) flat panel detector coupled with Csl (TI) (thallium-doped cesium iodide) scintillator, a linearly moving couch, a rotational gantry coupled with positioning encoder, and a parallel processing system for image data. This system was designed to be of the gantry-rotation type which has several advantages in obtaining CT images of live mice, namely, the relative ease of minimizing the motion artifact of the mice and the capability of administering respiratory anesthesia during scanning. We evaluated the spatial resolution, image contrast, and uniformity of the CT system using CT phantoms. As the results, the spatial resolution of the system was approximately the 11.3 cycles/mm at 10% of the MTF curve, and the radiation dose to the mice was 81.5 mGy. The minimal resolving contrast was found to be less than 46 CT numbers on low-contrast phantom imaging test. We found that the image non-uniformity was approximately 70 CT numbers at a voxel size of ${\sim}55{\times}55{\times}X100\;{\mu}^3$. We present the image test results of the skull and lung, and body of the live mice.

  • PDF

The study on Standard Uptake Value(SUV) change according to time input difference in PET/CT scan (PET/CT 검사에서 시간 입력 차이에 따른 표준화섭취계수(SUV) 변화에 대한 고찰)

  • Kim, Kyung-Sik;Lee, Ju-Young;Jung, Woo-Young;Kim, Jung-Sun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.21-25
    • /
    • 2011
  • Purpose: $^{18}F$-FDG Fusion Whole Body PET scan is performed approximately 1 hour after injecting $^{18}F$-FDG. At this point in the injection procedure, as a tool of the criteria of time input, time of clocks or computers can be used and in the scan procedure, time of workstation can be used. In case that synchronized time input is not done in the injection and scan procedures for PET scan, time error from injection to scan can occur. This time error may affect Standard Uptake Value (SUV) being used as quantitative assessment. Therefore, in this study, we analyzed the change of SUV according to time input difference and necessity of time synchronization. Materials and Methods: The analysis was performed to 30 patients ($54.8{\pm}15.5$ years old) who examined $^{18}F$-FDG Fusion Whole Body PET scan in Department of nuclear medicine, Asan Medical Center from December 2009 to February 2010. To observe the change of SUV according to time input difference, the image was reconstructed and analyzed by artificially changing time difference of 1, 2, 3, 5, 10, 20 min against the same patients based on 60 minutes. Result: SUV of the image that reconstructed the images of 30 patients by giving intervals of 1, 2, 3, 5, 10, 20 min respectively and the image that entered original time was compared and analyzed through paired t-test. Based on 0 minute, mean SUV of aorta was changed by 0.3, 1.1, 1.4, 3.2, 4.7, 12.5% respectively and there was no statistically significant difference in 1, 2 minutes (p>0.05) but there was significant difference in 3, 5, 10, 20 min (p<0.05). The changes of $SUV_{avg}$ of liver were 1.6, 2.5, 3.0, 4.2, 6.6, 12.8% in 1, 2, 3, 5, 10, 20 min respectively and the changes of $SUV_{max}$ of primary lesion were 1.0, 1.5, 2.2, 3.5, 6.6, 12.8% respectively (p<0.05). Conclusion: Errors may occur in the process of measuring or recording variables affecting SUV such as height and weight of patients, $^{18}F$-FDG dose, Emission scan start time etc. and as these errors are more, the accurate assessment of SUV is interfered. Therefore, in order to assess SUV more accurately, it is thought that efforts to minimize these errors should be made. Of these efforts, time synchronization will be a cornerstone for accurate scanning.

  • PDF

Facile Fabrication of Animal-Specific Positioning Molds For Multi-modality Molecular Imaging (다중 분자 영상을 위한 간편한 동물 특이적 자세 고정틀의 제작)

  • Park, Jeong-Chan;Oh, Ji-Eun;Woo, Seung-Tae;Kwak, Won-Jung;Lee, Jeong-Eun;Kim, Kyeong-Min;An, Gwang-Il;Choi, Tae-Hyun;Cheon, Gi-Jeong;Chang, Young-Min;Lee, Sang-Woo;Ahn, Byeong-Cheol;Lee, Jae-Tae;Yoo, Jeong-Soo
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.5
    • /
    • pp.401-409
    • /
    • 2008
  • Purpose: Recently multi-modal imaging system has become widely adopted in molecular imaging. We tried to fabricate animal-specific positioning molds for PET/MR fusion imaging using easily available molding clay and rapid foam. The animal-specific positioning molds provide immobilization and reproducible positioning of small animal. Herein, we have compared fiber-based molding clay with rapid foam in fabricating the molds of experimental animal. Materials and Methods: The round bottomed-acrylic frame, which fitted into microPET gantry, was prepared at first. The experimental mice was anesthetized and placed on the mold for positioning. Rapid foam and fiber-based clay were used to fabricate the mold. In case of both rapid foam and the clay, the experimental animal needs to be pushed down smoothly into the mold for positioning. However, after the mouse was removed, the fabricated clay needed to be dried completely at $60^{\circ}C$ in oven overnight for hardening. Four sealed pipet tips containing $[^{18}F]FDG$ solution were used as fiduciary markers. After injection of $[^{18}F]FDG$ via tail vein, microPET scanning was performed. Successively, MRI scanning was followed in the same animal. Results: Animal-specific positioning molds were fabricated using rapid foam and fiber-based molding clay for multimodality imaging. Functional and anatomical images were obtained with microPET and MRI, respectively. The fused PET/MR images were obtained using freely available AMIDE program. Conclusion: Animal-specific molds were successfully prepared using easily available rapid foam, molding clay and disposable pipet tips. Thanks to animal-specific molds, fusion images of PET and MR were co-registered with negligible misalignment.

Hydrogen and Ethanol Gas Sensing Properties of Mesoporous P-Type CuO

  • Choi, Yun-Hyuk;Han, Hyun-Soo;Shin, Sun;Shin, Seong-Sik;Hong, Kug-Sun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.222-222
    • /
    • 2012
  • Metal oxide gas sensors based on semiconductor type have attracted a great deal of attention due to their low cost, flexible production and simple usability. However, most works have been focused on n-type oxides, while the characteristics of p-type oxide gas sensors have been barely studied. An investigation on p-type oxides is very important in that the use of them makes possible the novel sensors such as p-n diode and tandem devices. Monoclinic cupric oxide (CuO) is p-type semiconductor with narrow band gap (~1.2 eV). This is composed of abundant, nontoxic elements on earth, and thus low-cost, environment-friendly devices can be realized. However, gas sensing properties of neat CuO were rarely explored and the mechanism still remains unclear. In this work, the neat CuO layers with highly ordered mesoporous structures were prepared by a template-free, one-pot solution-based method using novel ink solutions, formulated with copper formate tetrahydrate, hexylamine and ethyl cellulose. The shear viscosity of the formulated solutions was 5.79 Pa s at a shear rate of 1 s-1. The solutions were coated on SiO2/Si substrates by spin-coating (ink) and calcined for 1 h at the temperature of $200{\sim}600^{\circ}C$ in air. The surface and cross-sectional morphologies of the formed CuO layers were observed by a focused ion beam scanning electron microscopy (FIB-SEM) and porosity was determined by image analysis using simple computer-programming. XRD analysis showed phase evolutions of the layers, depending on the calcination temperature, and thermal decompositions of the neat precursor and the formulated ink were investigated by TGA and DSC. As a result, the formation of the porous structures was attributed to the vaporization of ethyl cellulose contained in the solutions. Mesoporous CuO, formed with the ink solution, consisted of grains and pores with nano-meter size. All of them were strongly dependent on calcination temperature. Sensing properties toward H2 and C2H5OH gases were examined as a function of operating temperature. High and fast responses toward H2 and C2H5OH gases were discussed in terms of crystallinity, nonstoichiometry and morphological factors such as porosity, grain size and surface-to-volume ratio. To our knowledge, the responses toward H2 and C2H5OH gases of these CuO gas sensors are comparable to previously reported values.

  • PDF

A study of Brain Micro-PET Imaging and Bindingpotential with a Different Specific Activity of 18F-Fallypride in the Small Animal (소동물에서 18F-Fallypride의 비방사능에 따른 뇌의 PET이미지와 Binding Potential 차이에 대한 연구)

  • Cho, Kyu-Sang;Ahn, Sung-Min
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.9
    • /
    • pp.418-424
    • /
    • 2015
  • In this study, we proceed if there are any changes in binding ability of receptor-ligand in some degree of SA and in radioactive uptake from the corpus striatum based on small animal experiment in vivo based on the S.A values. By dividing 18F-Fallypride into 3 S.A values(high S.A : 43.29~74 GBq/umol, ordinary S.A : 20.72~29.23 GBq/umol, low S.A : 6.29~8.51 GBq/umol), we injected directly into the veins and performed 90 minutes of dynamic scan using Micro PET. After scanning, we compared and analyzed with Binding Potential (Binding Potential) from the bilateral striatum. high SA and low SA, ordinary SA and low SA showed significant differences. Also, in the image comparison using 18F-Fallypride show high radioactive uptake in the striatum at high SA and ordinary SA, but the radioactive uptake at low SA is lower than other two SA. Since 18F-Fallypride has affinity to dopamine D2/3 pharmacokinetic, the difference of Binding Potentials at decreased level of SA values was not that significant. However, further PET research of the corpus striatum using 18F-Fallypride is necessary because the differences in images and Binding Potentials at 6.5 times smaller SA values compared to high SA value showed were significant.