• Title/Summary/Keyword: Image transfer system

Search Result 367, Processing Time 0.023 seconds

A Study on the Implementation of Multimedia Remote Ultrasound Image Transfer System through ISDN (ISDN(Integrated Services Digital Network)을 통한 멀티미디어 원격 초음파 영상 전달 시스템 구현에 관한 연구)

  • 이영훈;민경선
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.1
    • /
    • pp.33-42
    • /
    • 1996
  • A multimedia remote ultrasound image transfer system for tole-medical services was implemented. The image data of the ultrasound scanner system of the slave is compressed using image compression system. It is transferred to the master PC via ISDN UNI(User-Network Interface) and decompressd by image decompression system. The total system is composed of three parts; first, the image capture card which transfers bidirection- al data between ultrasound scanner system and PC, second, image compression and decompression card, finally, ISDN TA(Terminal Adaptor) card for transferring the image. This system has a easy user interface because it is executed on the basis of MS-WINDOWS. So it is capable of serving medical services at a remote place.

  • PDF

An Efficient Image Information Transfer System for Wireless Image Sensor Network Environments (무선 이미지 센서네트워크 환경을 위한 효율적인 영상 정보 전송 시스템)

  • Lee, Sang-Shin;Kim, Jae-Ho;Won, Kwang-Ho;Kim, Joong-Hwan
    • Journal of KIISE:Information Networking
    • /
    • v.35 no.3
    • /
    • pp.207-214
    • /
    • 2008
  • There are lots of studies on application systems using wireless sensor networks. As the application systems are adapted to industrial field, the reliability of these systems becomes new key feature. The lack of reliability is an obstacle to extension of wireless sensor networks. In this paper, we propose the monitoring system framework that can offer the reliability of wireless sensor networks using a micro camera module and wireless sensor network nodes. And also we propose the efficient transfer method for image information over low rate wireless networks. Using these system framework and transfer method, we implement WiSN(Wireless image Sensor Network) based fire monitoring system.

Development of a transfer learning based detection system for burr image of injection molded products (전이학습 기반 사출 성형품 burr 이미지 검출 시스템 개발)

  • Yang, Dong-Cheol;Kim, Jong-Sun
    • Design & Manufacturing
    • /
    • v.15 no.3
    • /
    • pp.1-6
    • /
    • 2021
  • An artificial neural network model based on a deep learning algorithm is known to be more accurate than humans in image classification, but there is still a limit in the sense that there needs to be a lot of training data that can be called big data. Therefore, various techniques are being studied to build an artificial neural network model with high precision, even with small data. The transfer learning technique is assessed as an excellent alternative. As a result, the purpose of this study is to develop an artificial neural network system that can classify burr images of light guide plate products with 99% accuracy using transfer learning technique. Specifically, for the light guide plate product, 150 images of the normal product and the burr were taken at various angles, heights, positions, etc., respectively. Then, after the preprocessing of images such as thresholding and image augmentation, for a total of 3,300 images were generated. 2,970 images were separated for training, while the remaining 330 images were separated for model accuracy testing. For the transfer learning, a base model was developed using the NASNet-Large model that pre-trained 14 million ImageNet data. According to the final model accuracy test, the 99% accuracy in the image classification for training and test images was confirmed. Consequently, based on the results of this study, it is expected to help develop an integrated AI production management system by training not only the burr but also various defective images.

A Method to Prevent Transfer Device of Image Stabilizer from Blunting by Artificial Vibration (가진입력에 의한 손떨림 보정용 이송장치의 둔화현상 방지대책)

  • Yeom, Dong-Hae
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.15 no.11
    • /
    • pp.1076-1079
    • /
    • 2009
  • This article deals with an optical image stabilizer which moves an image sensor in the direction of cancelling the vibration caused by hand shaking to prevent a photographed image from blurring. The ball-guide way method adopted as a transfer device of the image sensor is easy to be manufactured because of its simple structure and is suitable to minimize the friction between mechanisms, but has weakness of a chance of physical defect such as groove and rising. In case that the movement of the transfer device equipped with the image sensor is blunted because a ball is stuck in defects of guide way, the performance of the image stabilizer falls down drastically. We propose a method to prevent the transfer device from blunting by applying artificial vibration. At this time, the artificial vibration should be designed under consideration of dynamic characteristics and specifications of the system to be discriminated from the vibration caused by hand shaking.

Implementation Of Moving Picture Transfer System Using Bluetooth (Bluetooth를 이용한 동영상 전송 시스템 구현)

  • 조경연;이승은;최종찬
    • Proceedings of the IEEK Conference
    • /
    • 2001.06a
    • /
    • pp.25-28
    • /
    • 2001
  • In this paper we implement moving picture transfer system using bluetooth Development Kit (DK). To reduce the size of the image data, we use M-JPEG compression. We use bluetooth Synchronous Connection-Oriented (SCO) link to transfer voice data. Server receive image data from camera and compress the image data in M-JPEG format, and then transmit the image data to client using bluetooth Asynchronous connection-less (ACL) link. Client receive image data from bluetooth ACL link and decode the compressed image and then display the image to screen. Sever and Client can transmit and receive voice data simultaneously using bluetooth SCO link. In this paper bluetooth HCI commands and events generated by host controller to return the results of HCI commands are explained and the flow of bluetooth connection procedure is presented.

  • PDF

A Development of Image Transfer Remote Maintenance Monitoring System for Hand Held Device (휴대용 화상전송 원격정비 감시시스템의 개발)

  • Kim, Dong-Wan;Park, Sung-Won
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.3
    • /
    • pp.276-284
    • /
    • 2009
  • In this paper, we develop the image transfer remote maintenance monitoring system for hand held device which can compensate defects of human mistake. The human mistakes always happen when the worker communicate information each other to check and maintenance the equipment of the power plant under bad circumstance such as small place and long distance in power plant. A worker couldn't converse with other when in noisy place like Power plant. So, we make some hand device for handy size and able to converse in noisy place. The developed system can have improvement of productivity through increasing plant operation time. And developed system is composed of advanced H/W(hard ware) system and S/W(soft ware)system. The H/W system consist of media server unit, communication equipment with hand held device, portable camera, mike and head set. The advanced s/w system consist of data base system, client pc(personal computer) real time monitoring system which has server GUI(graphic user interface) program, wireless monitoring program and wire ethernet communication program. The client GUI program is composed of total solution program as pc camera program, and phonetic conversation program etc.. We analyzed the required items and investigated applicable part in the image transfer remote maintenance monitoring system with hand held device. Also we investigated linkage of communication protocol for developed prototype, developed software tool of two-way communication and realtime recording skill of voice with image. We confirmed the efficiency by the field test in preventive maintenance of plant power.

Film Image Transfer System (FITS): An Efficient Method for Proper Positioning of Orthodontic Mini-implants

  • Go, Taek-Su;Kim, Seong-Hun;Nelson, Gerald
    • Journal of Korean Dental Science
    • /
    • v.4 no.1
    • /
    • pp.20-25
    • /
    • 2011
  • Purpose: To describe the newly developed Film image transfer system (FITS) for proper positioning of the orthodontic mini-implant in the narrow interdental space and considerations for better application. Materials and Methods: A patient who was planning to have orthodontic mini-implant treatment on the posterior maxilla was recruited to assess the feasibility of FITS. Dental radiographic film and bite record was taken. And then the film image was transferred on the photographic emulsion coated model using transfer light through film projector (enlarger). After exposing the photo emulsion coating on the model, the image was developed with a working solution for a paper developer and fixed. The surgical guide for the mini-implant was fabricated from the transported FITS data. Results: The completed surgical guide was easily placed intraorally, and allowed a simple and rapid placement of the mini-implant. The site of the implant placement was accurate as planned position. Conclusion: In the reported case, The FITS technique represents an effort to minimize risk to the patient and produce consistently good results based upon accurate information about the anatomy of the implant site.

Digital X-ray Imaging in Dentistry (치과에서 디지털 x-선 영상의 이용)

  • Kim Eun-Kyung
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.29 no.2
    • /
    • pp.387-396
    • /
    • 1999
  • In dentistry. RadioVisioGraphy was introduced as a first electronic dental x-ray imaging modality in 1989. Thereafter. many types of direct digital radiographic system have been produced in the last decade. They are based either on charge-coupled device(CCD) or on storage phosphor technology. In addition. new types of digital radiographic system using amorphous selenium. image intensifier etc. are under development. Advantages of digital radiographic system are elimination of chemical processing, reduction in radiation dose. image processing, computer storage. electronic transfer of images and so on. Image processing includes image enhancement. image reconstruction. digital subtraction, etc. Especially digital subtraction and reconstruction can be applied in many aspects of clinical practice and research. Electronic transfer of images enables filmless dental hospital and teleradiology/teledentistry system. Since the first image management and communications system(IMACS) for dentomaxillofacial radiology was reported in 1992. IMACS in dental hospital has been increasing. Meanwhile. researches about computer-assisted diagnosis, such as structural analysis of bone trabecular patterns of mandible. feature extraction, automated identification of normal landmarks on cephalometric radiograph and automated image analysis for caries or periodontitis. have been performed actively in the last decade. Further developments in digital radiographic imaging modalities. image transmission system. imaging processing and automated analysis software will change the traditional clinical dental practice in the 21st century.

  • PDF

A Robot System Maintained with Renewable Energy

  • Kim, Jaehyun;Moon, Chanwoo
    • International journal of advanced smart convergence
    • /
    • v.8 no.1
    • /
    • pp.98-105
    • /
    • 2019
  • Energy autonomy is a system that is sustained by energy from an independent and distributed source such as renewable energy. In this paper, we propose a robotic energy autonomy in which a robot obtains energy from a renewable energy source with a limited storage capacity. As an energy transfer method, wireless power transfer is used to solve the problem of the conventional contact charging method, mechanical complexity, and to obtain high energy transfer efficiency, the image information is used to align the transmitting and receiving coils accurately. A small scale thermoelectric energy source with boost converter, battery charger, and wireless power transfer coil is constructed and an actual charging experiment is conducted to verify the proposed autonomy system.

Comparison of Image Quality of the Amorphous Silicon DR System and the Film-screen Systems (비정질 실리콘 디지털 방사선 촬영기와 X-ray film과의 영상질 비교 평가)

  • Youn, Je-Woong;Lee, Hyoung-Koo;Suh, Tae-Suk;Choe, Bo-Young;Shin, Kyung-Sub;Mun, In-K.;Kim, Hong-Kwon;Han, Yong-Woo;Nam, Seung-Bae
    • Journal of Radiation Protection and Research
    • /
    • v.24 no.3
    • /
    • pp.161-170
    • /
    • 1999
  • System performances in terms of image quality between an amorphous silicon DR system and a conventional film-screen system were evaluated. Various aspects of image quality MTF (modulation transfer function), NPS (noise power spectrum), SNR(signal-to-noise ratio) and contrast were measured and calculated. The MTF of the DR system was comparable to the film-screen systems. The noise was mainly dominated by the quantum mottle in both systems and the electronic noise was found in the DR system. The contrast of the DR system was better than the film-screen systems by virtue of high sensitivity and image processing. Compared to the film-screen systems in general radiography, the DR system had similar resolution and showed better contrast with the same exposure condition after contrast manipulation. The results of this study provide some useful information about the performance of the DR system in connection with medical applications.

  • PDF