• 제목/요약/키워드: Image motion analysis

검색결과 421건 처리시간 0.031초

Demineralized Bone Matrix (DBM) as a Bone Void Filler in Lumbar Interbody Fusion : A Prospective Pilot Study of Simultaneous DBM and Autologous Bone Grafts

  • Kim, Bum-Joon;Kim, Se-Hoon;Lee, Haebin;Lee, Seung-Hwan;Kim, Won-Hyung;Jin, Sung-Won
    • Journal of Korean Neurosurgical Society
    • /
    • 제60권2호
    • /
    • pp.225-231
    • /
    • 2017
  • Objective : Solid bone fusion is an essential process in spinal stabilization surgery. Recently, as several minimally invasive spinal surgeries have developed, a need of artificial bone substitutes such as demineralized bone matrix (DBM), has arisen. We investigated the in vivo bone growth rate of DBM as a bone void filler compared to a local autologous bone grafts. Methods : From April 2014 to August 2015, 20 patients with a one or two-level spinal stenosis were included. A posterior lumbar interbody fusion using two cages and pedicle screw fixation was performed for every patient, and each cage was packed with autologous local bone and DBM. Clinical outcomes were assessed using the Numeric Rating Scale (NRS) of leg pain and back pain and the Korean Oswestry Disability Index (K-ODI). Clinical outcome parameters and range of motion (ROM) of the operated level were collected preoperatively and at 3 months, 6 months, and 1 year postoperatively. Computed tomography was performed 1 year after fusion surgery and bone growth of the autologous bone grafts and DBM were analyzed by ImageJ software. Results : Eighteen patients completed 1 year of follow-up, including 10 men and 8 women, and the mean age was 56.4 (32-71). The operated level ranged from L3/4 to L5/S1. Eleven patients had single level and 7 patients had two-level repairs. The mean back pain NRS improved from 4.61 to 2.78 (p=0.003) and the leg pain NRS improved from 6.89 to 2.39 (p<0.001). The mean K-ODI score also improved from 27.33 to 13.83 (p<0.001). The ROM decreased below 2.0 degrees at the 3-month assessment, and remained less than 2 degrees through the 1 year postoperative assessment. Every local autologous bone graft and DBM packed cage showed bone bridge formation. On the quantitative analysis of bone growth, the autologous bone grafts showed significantly higher bone growth compared to DBM on both coronal and sagittal images (p<0.001 and p=0.028, respectively). Osteoporotic patients showed less bone growth on sagittal images. Conclusion : Though DBM alone can induce favorable bone bridging in lumbar interbody fusion, it is still inferior to autologous bone grafts. Therefore, DBM is recommended as a bone graft extender rather than bone void filler, particularly in patients with osteoporosis.

도시철도 차량 주행시 곡선스킬소음 실험 및 고찰 (Field Measurements and Review of the Curve Squeal Noise of Urban Railways)

  • 김재철;김관주;이준헌;김지용
    • 한국철도학회논문집
    • /
    • 제20권2호
    • /
    • pp.165-172
    • /
    • 2017
  • 도심을 지나는 철도 궤도는 급격한 곡선 구간이 존재하며, 철도차량이 곡선부를 주행하며 발생시키는 높은 주파수의 스킬소음은 곡선부 인근에 소음 민원을 야기하고, 해당 구간 궤도의 마모를 과도하게 발생시킨다. 본 논문에서는 대표적 비선형, 과도 특성인 스킬소음의 현상을 정확하게 파악하기 위해서 실차를 대상으로 곡선부 스킬 소음실험을 수행하였다. 특정 대차내 4 차륜을 대상으로 스킬소음의 음압의 크기, 주파수 특성, 주행 속도 변화에 따른 영향, 차륜의 진동응답특성과 스킬소음의 연관관계를 파악하였다. 동시에 차륜과 레일의 접촉 위치의 변화를 촬영한 영상을 분석하여 스킬소음 발생시 차륜의 레일에 대한 상대적 움직임에 대한 현상을 살펴보았다. 철도 차량 곡선 주행시 스킬소음은 내측 전륜에서 가장 크게 발생하며, 이는 차륜의 횡방향 진동 응답 특성과 관련이 있다고 생각된다. 이 발생 스킬소음의 크기는 차량 속도 증가와는 직접적인 관련이 없음을 알 수 있었다.

3차원 동영상의 시각 주의 확률 모델 도출 및 시각 주의 기반 입체감 추정 (Modeling of Visual Attention Probability for Stereoscopic Videos and 3D Effect Estimation Based on Visual Attention)

  • 김보은;송원석;김태정
    • 정보과학회 논문지
    • /
    • 제42권5호
    • /
    • pp.609-620
    • /
    • 2015
  • 시청자들은 영상을 시청할 때 화면상 시각이 집중된 곳 주변의 정보를 영향력 있게 받아들일 가능성이 크다. 이러한 사실을 이용하여 최근 연구들은 시각 주의 모델을 영상 제작 및 평가 방법에 이용하고 있다. 본 연구에서는 실제로 사람들의 시각 주의도가 어떠한 인자에 영향을 많이 받는지, 또 시각 주의 모델은 구체적으로 어떠한 형태가 되는지를 통계적 실험 계획법을 이용하여 추정하였다. 분산 분석법을 이용하여 속도, 화면으로부터의 거리, 비초점흐림 정도가 시각 주의에 영향을 미치는 유의한 인자인 것을 확인하였고 반응 표면 계획법을 이용하여 이 세가지 인자들에 따른 시각 주의 점수 모델을 도출하였다. 이 시각 주의 점수 모델로부터 영상 각 픽셀의 시각 주의 확률을 구하였다. 본 연구의 뒷부분에서는 시각주의 확률 모델을 기존의 기울기(gradient) 기반 3차원 영상의 입체감 측정법에 적용하는 방법을 제안하였다. 화면 상에서 시선을 집중할 확률이 큰 부분에 높은 비중을 둠으로써 기존의 방법 보다 시청자가 느끼는 입체감을 더욱 정확하게 측정할 수 있도록 하였다. 제안한 방법의 성능을 검증하기 위해 주관적 평가를 실시하여 피실험자들이 느끼는 입체감과 제안된 방법으로부터 도출한 결과를 비교하였다. 실험 결과 제안한 방법이 기존의 방법에 비해 성능이 높은 것을 확인하였다.

피부색과 무게중심 프로필을 이용한 손동작 인식 알고리즘 (Hand Motion Recognition Algorithm Using Skin Color and Center of Gravity Profile)

  • 박영민
    • 문화기술의 융합
    • /
    • 제7권2호
    • /
    • pp.411-417
    • /
    • 2021
  • 인간과 컴퓨터의 상호작용을 연구하는 분야를 HCI(Human-computer interaction)라고 한다. 이 분야는 인간과 컴퓨터 간에 서로 소통하면서 정보를 인식하는 방법에 대해 연구하는 학문 분야이다. 본 연구는 사람과의 상호작용을 위한 손동작 인식에 대한 연구로써 기존 인식방법의 문제점을 살펴보고 인식률을 개선하기 위한 알고리즘을 제시한다. 사람의 손 모양이 포함된 영상을 대상으로 피부색 정보를 바탕으로 손 영역을 추출하고, 주성분 분석을 이용하여 무게중심 프로필을 계산한다. 이렇게 얻은 정보를 미리 정의된 형상들과 비교하여 손동작을 인식률을 높이는 방법을 제안하였다. 기존의 무게중심 프로필은 회전으로 인한 손의 변형에 대해 잘못된 손동작 인식을 결과를 보여주었으나, 본 연구에서는 무게중심 프로필을 이용하고 모든 윤곽선의 점들과 무게중심 사이의 거리가 가장 긴 점을 시작점으로 하여 무게중심 프로필을 다시 개선함으로써 강건한 알고리즘을 제시하였다. 손동작 인식을 위하여 센서가 부착된 장갑이나 특별한 마커를 사용하지 않으며, 별도의 청색 스크린을 설치하지도 않는다. 이 결과에 대해 가장 가까운 거리의 특징벡터를 찾아 잘못된 인식을 해결하고, 적당한 경계치를 구하여 성공과 실패를 구분한다.

무릎 이상에 대한 자화전이 위상감각에 의한 정량분석법 (Quantitative Analysis of Magnetization Transfer by Phase Sensitive Method in Knee Disorder)

  • 윤문현;성미숙;인창식;이흥규;최보영
    • Investigative Magnetic Resonance Imaging
    • /
    • 제10권2호
    • /
    • pp.98-107
    • /
    • 2006
  • 자화전이영상 (MTI)은 무릎의 연골조직, 활액, 연대 등에 있는 거대분자에 붙어 분자운동에 제한을 받은 수소와 비교적 자유로운 물 분자의 수소가 두 가지 자화 상태로 서로 교환되고 있는 상태에서 한쪽 자화상태를 RF 펄스를 사용하여 포화시키면 다른 자화 상태가 교환 상황에 따라 그 신호강도가 달라지면서 영상의 대조도를 이룬다. 교차이완은 수소의 T2 이완시간이 다르면서 생기는 두 스핀 풀로 모델화하여 물 분자와 거대분자 사이의 쌍극자들의 상호교환 뿐만 아니라 물분자와 거대분자의 수소 화학교환으로 설명된다. 이에 의학영상에서 가장 필수적 요소인 신호강도와 대조도를 조절하는 능력으로서 양성자 밀도와 T2 강조 무릎영상을 획득하여 비정상적 조직과 그 변화 위에 시퀀스와 더불어 무릎 조인트의 중간신호들에 의해 무릎 연골주위의 다른 조직과의 신호강도 차이를 더욱 높이기도 한다. 또한 지방억제 기술은 조직 대조도를 증대시키고 화학전이 인공물을 제거할 뿐 아니라 움직임과 관련한 고스트 인공물을 감소시킨다. 이와 같은 지방 포화억제는 위상감각 방법 (Phase Sensitive Method)에서 물과 지방의 세차운동 주파수에 차이를 나타낸다. 본 연구에서 위상감각 방법은 Larmor 주파수 차이를 직접 사용하기 보다는 그 주파수 차이결과를 축적하여 생기는 위상 차이를 보고자 하였다. 자화전이영상이 어떻게 작동하는가는 무릎조직의 자화전이(MT)에 대한 정량적 모델로 유도되는 임상적 증거에서 주어지지만 그 자화전이 효과를 설명하는 수학적 공식화는 전방 십자형 인대 (Anterior Cruciate Ligament)파열과 관절간연골 파열과 같은 무릎관절질환을 평가하는 데 적용하였고, 자화전이 포화 효과의 계산은 MT 펄스에 의한 신호강도에 상대적 감소를 정량적으로 측정하는 자화전이률에 의해 주어졌다.糖) 및 이성화당(異性化糖)의 개발생산(開發生産)이 시급(時急)하며 이런 감미원(甘味源) 생산공장(生産工場)의 대규모화(大規模化)로 경제적(經濟的) 양산(量産)을 서둘러야 될 줄 생각(生覺)한다. 우선적(優先的)으로 소요(所要)의 효소생산(酵素生産)에 대(對)한 개발연구(開發硏究)가 앞서야 하며, 이어서 전분(澱粉)으로부터 이성화당(異性化糖)에 이르기까지 단계적(段階的) 효소처리공정(酵素處理工程)의 확립(確立)과 새로운 공정(工程)의 개발연구(開發硏究)가 이루어져야 하겠다. 나아가서 보다 더 경제적(經濟的) 감미료(甘味料)의 생산(生産)과 생산공정(生産工程)의 능율화(能率化)를 위(爲)하여 전분당화(澱粉糖化) 및 이성화(異性化) 공정(工程)의 연속화(連續化)가 필연적(必然的)이며, 이에 소요(所要) 및 불용성(不溶性) 효소(酵素)의 생산공정(生産工程)도 연구(硏究)되어야 한다.>$16.8{\sim}30.1$ kcal/mole의 범위 안에 있으며 ginsenoside-Re 및 $-Rg_1$$ginsenoside-Rb_1,\;-Rb_2$, -Rc 및 -Rd 보다 훨씬 높으므로 troil saponin이 diol saponin보다 온도(溫度)의 영향(影響)을 더 많이 받고 있었다. 마. total ginsenosides의 분해반응시(分解反應時)의 활성화(活性化)에너지($E_a$)는 17.7kcal/mole이었고 분해속도상수(分解速度常數)의 온도의존성(溫度依存性)은 $k=4.574{\times}10^8{\exp}(-8898.8/T)$의 관계식(關係式)으로 표시(表示)할 수 있다rc}C,\;30^{\circ}C,\;45^{\circ}C$ 별로 각 fine spirit에 oak chip을 넣고 숙성시킨

  • PDF

시각적 연출에 의한 3D 입체 애니메이션 표현 연구: 〈드래곤 길들이기〉를 중심으로 (A Study on Expressing 3D Animation by Visual Direction : focused on 〈 How to train your dragon 〉)

  • 김정현
    • 만화애니메이션 연구
    • /
    • 통권26호
    • /
    • pp.1-30
    • /
    • 2012
  • 애니메이션의 목적은 움직임을 통해 재미있는 스토리를 관객에게 전달하는 것이라고 할 수 있다. 이러한 목적을 달성하기 위해 애니메이션은 탄생 이후 지금까지 100여년 이상의 시간동안 수많은 기술들을 도입하면서 다양한 내러티브 방법과 시각 표현 방법을 개발해 왔다. 또한 표현 기술력이 발달하면서 애니메이션을 구성하는 모든 요소들도 점점 체계화되어 왔고, 동시에 현실 그 이상의 세계를 표현할 수 있도록 해 주었다. 말 그대로 애니메이션을 제작하는 감독이 상상하는 모든 것들을 스크린을 통해 관객이 눈으로 볼 수 있는 시대가 된 것이다. 그리고 현재에는 애니메이션을 관람하는 관객이 마냥 프레임 안에서 움직이는 그림에 의해 즐거움을 느끼게 되는 시대를 넘어서도록 많은 노력이 이루어지고 있다. 즉, 수동적으로 바라보는 애니메이션을 넘어 관객이 직접 느끼며, 체감하는 애니메이션으로 목적성이 변화하고 있다는 것이다. 이런 과정에서 그 중심에 3D 입체라는 기술이 애니메이션의 새로운 즐거움을 표현할 수 있도록 해주고 있다. 얼마 전, 국내에서도 극장용 3D 입체 애니메이션이 제작되었으나, 해외의 3D 입체 애니메이션과 같은 완성도 높은 영상미를 기대했던 관객에게 새로운 즐거움을 주지 못해 흥행 면에서 이렇다 할 성적을 거두지 못하였다. 이것은 국내의 입체 애니메이션 제작 산업이 아직 초보적인 단계에 불과하여 3D 입체 애니메이션 제작에 대한 인력 및 기술, 경험이 절대적으로 부족한 상태에서 제작되었기 때문이다. 그리고 대부분의 입체에 대한 연구가 재현 기술적 문제에 집중되어 있어 관객들이 직접적으로 접하게 되는 영상 그 자체에 대한 연구 또한 부족하거나 미흡한 실정인 것도 커다란 문제라 할 수 있다. 이러한 국내 상황 속에서 2010년에 개봉되었고, 현재까지 최고의 3D 입체 애니메이션 흥행작으로 손꼽히고 있는 드림웍스 작품인 <드래곤 길들이기>의 입체영상 화면은 연구될 가치가 충분하다 할 수 있다. 따라서 본 논문은 양질의 국내 3D 입체 애니메이션 제작 및 전문 인력 양성 시기초자료로 활용되고자 풍부한 입체감을 전달하기 위해 화면을 담아내는 시각적 연출을 중심으로 이론적 고찰과 사례를 분석하여 연구하였다. 그 결과 3D 입체 애니메이션은 새로운 분야가 아닌 기존 영상미학의 원리를 기반으로 입체영상의 특성이 적용되어져 확장되고 변화된 영역인 것을 알 수 있었다. 이러한 연구를 통해 실재감 재현을 위한 3D 입체 애니메이션 콘텐츠 제작에 필요한 이론적 기초연구의 토대를 구축하는데 도움이 될 것으로 본다.

인터랙티브 내러티브에 관한 연구 - VR 애니메이션 <Wolves in the Walls>의 분석을 중심으로 (A Study on the Interactive Narrative - Focusing on the analysis of VR animation <Wolves in the Walls>)

  • 성호장
    • 트랜스-
    • /
    • 제15권
    • /
    • pp.25-56
    • /
    • 2023
  • VR 콘텐츠는 정보의 밀도가 매우 높은 동적 이미지 시뮬레이션 기술을 기반으로 공간감과 현실감 확보를 통해 체험자에게 깊은 몰입감을 가져다준다. 하지만 높은 정보 밀도의 내부 정보들은 한편 객관적이지 않은 착각을 형성하기도 한다. 때문에 사용자에게 높은 밀도의 동적 이미지 정보를 해석할 수 있는 적절한 안내가 필요하다. 게임에서 네비게이션 인터페이스와 상호작용 기능을 설정하는 것처럼, 가상현실에서의 상호작용은 가상 콘텐츠를 해석, 향유하는 기본적 토대이다. 본 연구는 VR 콘텐츠 제작의 중요한 부분인 상호작용적인 스토리텔링 설계에 대한 사례 분석을 기반으로 한다. 가상현실 콘텐츠에서 더 우수한 상호작용적인 스토리텔링 모델을 탐색하기 위해 기본적인 주요개념들을 고찰하고 VR 애니메이션 <Wolves in the Walls>의 상호작용적인 스토리텔링 특징을 분석한다. 분석의 결과로 정리된 결론은 첫째, VR 환경이 사용자에게 자유롭게 이동할 수 있는 장점을 충분히 활용해야 하며, 상호작용 모듈 설계시 사용자의 현장감을 충분히 고려해야 한다는 점이다. 이를 통해 관객의 상호작용을 유도하여 참여도를 높힘으로서 VR이라는 핫미디어를 쿨미디어적 참여를 유도할 수 있다. 둘째, 사용자가 자유도가 매우 높은 가상 환경에 처음 들어갔을 때 모호한 세계 상황에 대해 당황하지 않도록, 작품의 초기 단계에서는 개발자 주도의 서술을 제공해야 한다. 셋째, 일부 게임에서 텍스트를 통해 사용자에게 안내하는 것과 달리, 사용자와 스토리 캐릭터(NPC)와의 자연스러운 대화를 추가하는 더 자연스러운 상호작용 방식을 통해 안내할 수 있다. 본 연구는 VR 애니메이션 <Wolves in the Walls>의 상호작용적인 스토리텔링 특징을 분석하고 정리함으로써 다양한 형태로 진화되고 있는 VR 콘텐츠의 설계의 한 가이드라인을 제공한다.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

'오브제(Object) 애니메이션'의 미학적 정서와 창의성에 관한 연구 -문화예술교육 결과물의 '오브제(Object)' 유형 분석을 중심으로- (A Study on the Aesthetic Emotion and Creativity of 'Objet Animation' -Focused on the analysis of 'Objet' type of cultural arts education outcomes-)

  • 김현영;김재웅
    • 만화애니메이션 연구
    • /
    • 통권50호
    • /
    • pp.43-73
    • /
    • 2018
  • 연구는 애니메이션 문화예술교육 중 '오브제(Object)'에 관한 연구이다. 현대 예술에서 오브제의 활용에 관한 연구는 활발하게 진행되고 있다. 큐비즘부터 다다이즘, 초현실주의, 미래파, 팝아트에 이르기까지 오브제는 현대미술과 발걸음을 함께 한다고 해도 과언이 아닐 것이다. 또한 오브제는 키네틱 아트, 비디오 아트, 미디어 아트, 애니메이션 등 '움직임'을 표현하는 영상예술 분야에서도 주목할 만한 가치를 가지고 있다. 그러나 예술작품에 사용되는 오브제의 유형을 분류하고 연구한 사례는 많지 않다. 이에 본 연구자는 초현실주의 담론에서 영향을 받아 6가지 오브제 유형분석 틀을 마련하고 오브제 애니메이션의 '미학적 정서와 창의성 향상의 교육적 측면'을 고찰하는 연구를 진행하였다. 유형분석틀은 드로잉 오브제, 실재(존재)의 오브제, 몰핑 오브제, 표피의 오브제, 대입된 오브제, 아상블라주 오브제로 명명하였고 이 유형을 사례 이미지와 함께 제시하며 분석하였다. 본 연구에 사용된 자료는 문화예술교육에서 비전문가를 대상으로 교육한 오브제 애니메이션 결과물을 중심으로 하였다. 미학적 정서는 프로이드가 말한 생명에 대한 욕구(Eros)를 Attraction(매혹)으로, 죽음에 관한 욕구(Thanatos)를 Uncanny(두려운 낯설음)으로 칭하며 상반된 개념을 토착신앙인 Animism과 연결하여 설명하였다. 다음으로 게슈탈트 심리학자인 카를 던커(Karl Duncker, 1903-1940)가 말한 '기능적 고정성(Functional fixedness)'이란 용어와 관련지어 오브제 애니메이션의 교육적 측면인 '창의성'에 관하여 논하였다. 기능적 고정성 극복이란 사물이 가진 기능적인 측면에만 고착되어 발상의 전환을 하지 못하는 현상이다. 본 연구에서는 '오브제 애니메이션' 문화예술교육을 통해 기능적 고정성을 극복한 사례로 창의성 향상의 교육적 측면을 논하였다. 궁극적으로 본 연구는 오브제 애니메이션의 미학적 정서와 창의성 향상의 교육적 측면을 '오브제 유형 분석'을 통해 고찰하는 것이다. 나아가 '오브제 애니메이션'을 문화예술교육에서 활용할 때 방향성을 제시하는 것에 의의가 있다.