• 제목/요약/키워드: Image intensifier

검색결과 63건 처리시간 0.023초

사각탱크 내부의 기포구동유동에 대한 동특성 연구 (Dynamic Analysis of Bubble-Driven Liquid Flows in a Rectangular Tank)

  • 김상문;이승재;김현동;김종욱;김경천
    • 한국가시화정보학회지
    • /
    • 제8권1호
    • /
    • pp.31-38
    • /
    • 2010
  • An experimental study to evaluate dynamic structures of flow and turbulence characteristics in bubble-driven liquid flow in a rectangular tank with a varying flow rate of compressed air is conducted. Liquid flow fields are measured by time-resolved particle image velocimetry (PIV) with fluorescent tracer particles to eliminate diffused reflections, and by an image intensifier to acquire enhanced clean particle images. Instantaneous vector fields are investigated by using the two frame cross-correlation function and bad vectors are eliminated by magnitude difference technique. By proper orthogonal decomposition (POD) analysis, the energy distributions of spatial and temporal modes are acquired. When Reynolds number increases, bubble-induced turbulent motion becomes dominant rather than the recirculating flow near the side wall. The total kinetic energy transferred to the liquid from the rising bubbles shows a nonlinear relation regarding the energy input because of the interaction between bubbles and free surface.

Diagnostics of Magnetron Sputtering Plasmas: Distributions of Density and Velocity of Sputtered Metal Atoms

  • Sasaki, Koichi
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제42회 동계 정기 학술대회 초록집
    • /
    • pp.98-99
    • /
    • 2012
  • Deposition of thin films using magnetron sputtering plasmas is a well-developed, classical technology. However, detailed investigations using advanced diagnostics are insufficient in magnetron sputtering, in comparison with plasma-aided dry etching and plasma-enhanced chemical vapor deposition. In this talk, we will show examples of diagnostic works on magnetron sputtering employing metal targets. Diagnostic methods which have fine spatial resolutions are suitable for magnetron sputtering plasmas since they have significant spatial distributions. We are using two-dimensional laser-induced fluorescence spectroscopy, in which the plasma space is illuminated by a tunable laser beam with a planer shape. A charge-coupled device camera with a gated image intensifier is used for taking the picture of the image of laser-induced fluorescence formed on the planer laser beam. The picture of laser-induced fluorescence directly represents the two-dimensional distribution of the atom density probed by the tunable laser beam, when an intense laser with a relatively wide line-width is used. When a weak laser beam with a relatively narrow linewidth is used, the laser-induced fluorescence represents the density distribution of atoms which feel the laser wavelength to be resonant via the Doppler shift corresponding to their velocities. In this case, we can obtain the velocity distribution function of atoms by scanning the wavelength of the laser beam around the line center.

  • PDF

요추디스크 수핵감압술을 위한 투시영상의 교정 (Correction of Fluoroscopic Image for Nucleoplasty in Lumbar Disc)

  • 윤영우;강세식;최석윤
    • 한국방사선학회논문지
    • /
    • 제10권5호
    • /
    • pp.359-365
    • /
    • 2016
  • 투시조영촬영은 인체 내부의 조직이나 장기를 검사할 때 시행하며 특히 척추 질환의 진단 및 시술에 사용된다. 영상증배관(image intensifier tube)을 사용하는 투시조영 촬영장비는 영상에서 중심부보다 주변부에 왜곡이 나타난다. 본 연구에서는 교정 알고리즘을 적용하여 교정전과 교정후의 수직길이비 왜곡비율과 대각길이비의 왜곡비율을 측정하였다. 수직길이비의 측정결과는 교정후의 표준편차가 교정전보다 0.04감소하였고 대각길이비의 측정결과는 교정후의 표준편차가 교정전보다 0.06감소하여 교정 후 투시영상의 왜곡이 감소되었다. 향후 교정 알고리즘의 적용과 성능향상을 통해서 영상왜곡을 감소시키면 요추디스크의 치료를 위한 수핵감압술시 요추천자의 정확한 위치를 찾는데 도움을 줄 것으로 사료된다.

감마선 분포 측정을 위한 섬광필름 기반의 감마 영상 검출기 제작 및 성능평가 (Fabrication and Performance Evaluation of a Scintillating Film-based Gamma Imaging Detector to Measure Gamma-ray Distribution)

  • 신상훈;유욱재;장경원;조승현;이봉수
    • 센서학회지
    • /
    • 제24권3호
    • /
    • pp.202-207
    • /
    • 2015
  • As a feasibility study on development of a gamma imaging probe, we developed a scintillating film-based gamma imaging detector that can obtain scintillation images with information of gamma-ray distribution. The scintillating film-based gamma imaging detector was composed of a sensing probe, an image intensifier, and a beam profiler. To detect and transmit scintillation image, the sensing probe was fabricated by coupling a scintillating film, a fiber-optic image conduit, and a fiber-optic taper, consecutively. First, the optical images of USAF 1951 resolution target were obtained and then, modulation transfer function values were calculated to test the image quality of the sensing probe. Second, we measured the scintillation images according to the activity of the 137Cs and the distance between the surface of 137Cs and the distal-end of sensing probe. Finally, the intensities of scintillating light as functions of the activity and the distance were evaluated from the region of interest in the scintillation image. From the results of this study, it is expected that a fiber-optic gamma imaging detector can be developed to detect gamma-rays emitted from radiopharmaceuticals during radioimmunoguided surgery.

The Performance of Heavy Ion CT System with Fluorescent Screen and CCD Camera

  • Tomida, Tetsuya;Nishimura, Katsuyuki;Abe, Shinji;Sato, Hitoshi;Muraishi, Hiroshi;Inada, Tetsuo;Tazawa, Shuichi;Kanai, Tatsuaki;Yusa, Ken;Kawachi, Kiyomitsu
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.432-435
    • /
    • 2002
  • We have developed and proposed the heavy ion CT system which consists of fluorescent screen and CCD camera equipped with image intensifier. In our system, we have measured the residual range of particles that passed a phantom and reconstructed the CT image for the distribution of relative stopping power by filtered back projection method with Shepp '||'&'||' Logan filter. The heavy ion $\^$12/C accelerated up to 400 MeV/u by HIMAC (Heavy Ion Medical Accelerator in Chiba) was used. Intensity of the beam output changes like macro pulse, the period being 3.3 sec and the width being 2 sec. The series of data was acquired in synchronizing with the pulse, leading to the improvement of S/N in the CT image. The fundamental performance was experimentally evaluated in the proposed system. The spatial resolution was estimated to be about 1 mm and the density resolution (electron density referred to water) to be about 0.01.

  • PDF

휴대용 적외선 야시경을 위한 전자회로설계 (Electronic Circuit Design for Portable Infrared Night Vision Scope)

  • 엄기환;김두환
    • 전자공학회논문지SC
    • /
    • 제43권2호
    • /
    • pp.33-39
    • /
    • 2006
  • 본 논문에서는 휴대용 적외선 야시경의 소형 경량화 및 저전력을 위한 전자회로부를 설계하였다. 설계한 전자회로부는 전압자동변환부와 전원공급부로 구성한다. 전압자동변환부는 배터리, 스위치부, 승압부, 전압선택부 등으로 구성한다. 전원공급부는 고광원 감지회로, 배터리 전압감지회로, 적외선 발광회로, 연결감지회로, 공급제어회로 등으로 구성한다. 설계한 전자회로부의 성능은 AN/PVS-14에 비하여 소모전력 및 상온 연속사용 시간에서 우수하였다.

Extravascular Migration of a Fractured Inferior Vena Cava Filter Strut

  • Lim, Jung Hyeon;Lee, Weon Yong;Ra, Yong Joon;Jeong, Jae Han;Park, Bong Suk;Ko, Ho Hyun
    • Journal of Chest Surgery
    • /
    • 제50권3호
    • /
    • pp.224-227
    • /
    • 2017
  • A 20-year-old man presented with a femur fracture and epidural hemorrhage (EDH) following a fall. One month after fracture surgery, swelling developed in both legs, and he was diagnosed as having a deep-vein thrombosis and pulmonary embolism. A retrievable inferior vena cava filter (IVCF) was inserted, because EDH is a contraindication to anticoagulants. Four months later, he complained of abdominal pain, and a computed tomography scan showed a fractured IVCF strut. After percutaneous removal failed 3 times, the IVCF was surgically removed by orthopedists using a portable image intensifier without cardiopulmonary bypass.

유조선 화물취급구역내 동력환기특성에 관한 연구 (A Study on Mechanical Ventilation Characteristics in Cargo Handling Area of Tanker)

  • 조대환
    • 해양환경안전학회지
    • /
    • 제7권1호
    • /
    • pp.15-23
    • /
    • 2001
  • In regulation of IGC code 12.1 mechanical ventilation should be arranged to ensure sufficient air movement through the space to avoid the accumulation of flammable or toxic vapours and ensure a safe working environment, but in no case should the ventilation system have a capacity of less than 30 changes of air per hour baed upon the total volume of the space. In this study, a scaled mode chamber was constructed to investigate the ventilation characteristics and stagnation area in the hood room of LNG carrier and pump room in tanker. An experimental study was performed on the model by using visualization equipment with a laser apparatus and an image intensifier CCD camera. Twelve different kinds of measuring areas were selected as the experimental condition. Instant simultaneous velocity vectors in the whole fields were measured by a 2-D PIV system A three-dimensional numerical simulation was also carried out for three different Reynolds numbers. Then the CFD predictions were discussed with the experimental results. The results show the spiral L-shape flow that moves from the opening on the left wall diagonally to the upper right part dominates the ventilation structure. The stationary area of hood room in the velcoity distributions was located in the upper left stern part.

  • PDF

Time-resolved PIV와 POD기법을 이용한 유량에 따른 단일노즐 버블링 유동 특성에 관한 연구 (Characteristics of Bubble-driven Flow with Varying Flow Rates by Using Time-resolved PIV and POD Technique)

  • 이승재;김종욱;김현동;김경천
    • 한국가시화정보학회지
    • /
    • 제6권2호
    • /
    • pp.14-19
    • /
    • 2008
  • In this paper, the recirculation flow motion and mixing characteristics driven by air bubble flow in a rectangular water tank is studied. The Time-resolved PIV technique is adopted for the quantitative visualization and analysis. 532 nm Diode CW laser is used for illumination and orange fluorescent particle images are acquired by a PCO 10bit high-speed camera. To obtain clean particle images, 545 nm long pass optical filter and an image intensifier are employed and the flow rates of compressed air is changed from 2 l/min to 4 l/min at 0.5 MPa. The recirculation and mixing flow field is further investigated by the POD analysis technique. It is observed that the large scale counterclockwise rotation and main vortex is generated in the upper half depth from the free surface and one quarter width from the sidewall. When the flow rates are increased, the main vortex core is moved to the side and bottom wall direction.

Time-resolved PIV와 POD기법을 이용한 단일노즐 버블링 유동 특성에 관한 연구 (Characteristics of Bubble-driven Flow by Using Time-resolved PIV and POD Technique)

  • 이승재;김종욱;김현동;김경천
    • 한국가시화정보학회지
    • /
    • 제6권1호
    • /
    • pp.41-46
    • /
    • 2008
  • In this paper, the recirculation flow motion and mixing characteristics driven by air bubble stream in a rectangular water tank is studied. The time-resolved PIV technique is adopted for the quantitative visualization and analysis. 488 nm Ar-ion CW laser is used for illumination and orange fluorescent ($\lambda_{ex}=540nm,\;\lambda_{em}=560nm$) particle images are acquired by a PCO 10bit high-speed CCD camera (1280$\times$1024). To obtain clean particle images, 545 nm long pass optical filter and an image intensifier are employed and the flow rates of compressed air is 3 l/min at 0.5 MPa. The recirculation and mixing flow field is further investigated by time-resolved POD analysis technique. It is observed that the large scale recirculation resulting from the interaction between rising bubble stream and side wall is the most dominant flow structure and there are small scale vortex structures moving along with large scale recirculation flow. It is also verified that the sum of 20 modes of velocity field has about 67.4% of total turbulent energy.