• 제목/요약/키워드: Image intensifier

검색결과 64건 처리시간 0.023초

DUPIC 핵연료봉 봉단 용접부 건전성 확인을 위한 미세초점 X-선 투과시험에 관한 연구 (A Study on the Micro-Focus X-Ray Inspection for Confirming the Soundness of End Closure Weld of DUPIC Fuel Elements)

  • 김웅기;김수성;이정원;양명승
    • Journal of Welding and Joining
    • /
    • 제19권1호
    • /
    • pp.88-94
    • /
    • 2001
  • DUPIC (Direct use of spent PWR fuel in CANDU reactors) nuclear fuel is a CANDU fuel fabricated remotely from spent PWR fuel materials in a hot cell. The soundness of the end closure welds of nuclear fuel elements is an important factor for the safety and performance of nuclear fuel. To evaluate the soundness of the end closure welds of DUPIC fuel element, a precise X-ray inspection system is developed using a micro-focus X-ray generator with an image intensifier and a real time camera system. The fuel elements made of Zircaloy-4 and stainless steel by an Nd:YAG laser welding and a TIG welding aye inspected by the developed inspection system. The soundness of the welds of the fuel elements was confirmed by the X-ray inspection process, and the irradiation test of DUPIC fuel elements has been successfully completed at the HANARO research reactor.

  • PDF

Optimal Localization through DSA Distortion Correction for SRS

  • Shin, Dong-Hoon;Suh, Tae-Suk;Huh, Soon-Nyung;Son, Byung-Chul;Lee, Hyung-Koo;Choe, Bo-Young;Shinn, Kyung-Sub
    • 한국의학물리학회지:의학물리
    • /
    • 제11권1호
    • /
    • pp.39-47
    • /
    • 2000
  • 신경 외과적 수술의 한분야인 정위적 방사선 수술은 두 개강 내의 병변의 위치 계산 후, 고선량의 방사선을 조사하여 병변을 치료하는 방법이기 때문에, 효과적인 수술을 위해서는 병변의 정확한 위치 정보가 무엇보다도 중요하다. 본 연구에서는 DSA(Digital Subtraction Angiography) 영상이 내재적으로 이미지 왜곡이라는 문제점을 가지고 있기 때문에, 이것의 보정을 통하여 더욱 정확한 target 위치를 계산하였다 이미지 왜곡을 보정하기 위하여 grid 팬텀을 제작하였고, localization 알고리즘의 정확도를 평가하기 위하여, target 팬텀을 제작하였다. Image Intensifier의 앞쪽에 grid 팬텀을 부착하고, target 팬텀을 Leksell Frame에 고정시킨 후, DSA 영상을 얻었다. 본 실험을 위하여 개발된 프로그램을 이용하여, Anterior and Posterior, Left and Right 영상에서 bilinear transform을 적용하여 왜곡을 보정한 후, target 위치를 계산하였다. 그리고, 이와 같은 방법을 통하여 계산된 target 위치 좌표와 target 팬텀의 절대 좌표의 비교를 통하여 localization 오차가 계산되었다. 이번 실험의 결과는 왜곡을 보정하지 않은 경우, localization 오차는 $\pm$0.41mm, 왜곡 보정을 한 경우는 $\pm$0.34mm이었다. 따라서 본 연구에서 개발된 알고리즘 정밀도가 인정되며, 환자의 치료에 적합한 것으로 사료된다.

  • PDF

Night Scope 광학계의 설계 및 개발 (Development and Design of the Optical System of a Night Scope)

  • 이동희;임용무
    • 한국안광학회지
    • /
    • 제9권1호
    • /
    • pp.11-17
    • /
    • 2004
  • 레저 스포츠 분야에서 사용되는 Night Scope를 설계 제작해 보았다. 전체 구성은 IR조명계, objective결상계, IR촬상 튜브부, eye_piece 결상계로 이루어진다. objective 결상계는 색수차가 감소되도록 BK7, FD4의 재질로 만들었는데 40% MTF(Modulation Transfer Function) 기준치에 대해 25lines/mm의 분해능을 가지도록 하였다. 이 시스템은 초점거리가 80mm, 유효구경이 40mm 결상면의 크기가 직경 14mm인 광학계로 설계되어졌다. eye_piece 결상계는 제품 비용을 절감하기 위해 상용제품을 채택하였다. 이번 개발에서 얻은 개발 기술은 향후 Dot, Sight, Day/Night Riflescope System 등의 유사 제품의 개발에도 크게 이용할 수 있을 것으로 판단된다.

  • PDF

복부투시조영 검사 시 Added filter와 Grid 변화에 따른 선량 및 화질에 관한 연구 (Study on dose and image quality by Added filter and Grid change when exam abdominal fluoroscopy)

  • 홍선숙;강경미;성민숙;이종웅
    • 대한디지털의료영상학회논문지
    • /
    • 제14권2호
    • /
    • pp.47-56
    • /
    • 2012
  • Amount of radiation exposure by seeing through fluoroscopy examination while is many patient exposure administration and unprepared misgovernment be. In this study, abdominal fluoroscopy during the scan, the dose and image quality change according to the use of grid and added filter optimized by measuring the test condition is proposed. Uses seeing through fluoroscopy examination equipment of Image Intensifier of Easy Diagnost Eleva (Philips), under tube type and uses Human phantom and measures average area dose according to grid insertion existence and nonexistence and added filter kind change. Measure sum of 29 organ dose and effective dose through PCXMC imagination simulation program and image J program through noise, SNR, image distortion was measured. Resolution, sharpness, and analyzed using the MTF curves. Fluorography the grid to insert the filter thickness and thickening and increased the average area dose and organ doses and effective dose. In the case of spot examination, when inserted grid, average area dose and organ dose and effective dose increased. Filter thickens the average area dose decreased, but the organ doses and effective dose were increased when use 0.2mmCu+1mmAl filter, decreased slightly. Noise and SNR measurements without inserting the gird, if you do not use the added filter was the lowest and when measure the distortion, 0.1mmCu+1mmAl filter was no difference of image quality in case insert grid was judged that when did not use occasion added filter that do not use grid, difference of image quality does not exist. Did not show a big difference, according to the grid and uses of the added filter sharpness, and resolution. Patient dose increases with factors that reduce the quality of the image so reckless grid and the use of the added filter when abdominal fluoroscopy examination should be cautious in using.

  • PDF

디젤엔진에서의 PCCI 연소 특성과 화염 가시화에 관한 연구 (A Study on the PCCI Combustion Characteristics and Flame Visualization in a Diesel Engine)

  • 박진규;이재민;김형익;김영진;이기형
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2012년도 제45회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.191-193
    • /
    • 2012
  • The use of diesel engines has recently increased due to the need for internal combustion engines with a high thermal efficiency and low harmful exhaust gas. The PCCI(premixed charged compression ignition) technology has been studied specifically to simultaneously reduce NOx and PM. While the PCCI means has the merit of reducing NOx and PM, control of the combustion phase is difficult. In this study, Flame visualization was then performed with an endoscope system in order to compare combustion flame characteristics in an commercial diesel engine.

  • PDF

조사시험용 핵연료봉 용접부 비파괴검사에 관한 연구 (A Study on the Non-destructive Inspection for End Closure Welding of Nuclear Fuel Elements for the Irradiation Test)

  • 김웅기;김수성;이철용;이도연;이정원
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2004년도 춘계 학술발표대회 개요집
    • /
    • pp.302-304
    • /
    • 2004
  • Nuclear fuel elements containing dry recycling nuclear fuel pellets for the irradiation test in a reactor were remotely fabricated from spent PWR fuel materials in a hot cell. End closure welding as well as seal tube welding for thermal sensor of the elements was performed by Nd:YAG laser. The soundness of the end closure welds and seal tube welds for the elements were evaluated by a precise X-ray inspection system composed of a micro-focus X-ray generator with an image intensifier and a real time camera system. Then, helium leak test was performed for the elements. The soundness of the welds of the fuel elements was confirmed by the X-ray inspection and helium leak test. The irradiation test for the fuel elements were successfully completed at the HANARO research reactor.

  • PDF

중간극 (20cm) 정극성 리-더의 진전 특성 (Characteristics of Positive Leader in Medium Gap)

  • 오철한;최영수;서욱창
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1987년도 정기총회 및 창립40주년기념 학술대회 학회본부
    • /
    • pp.484-485
    • /
    • 1987
  • The characteristics of leader development in rod -to- plane air gap (20cm gap length) under positive impulse potentials have been studied by means of 2-photomultiplier technique and image intensifier camera. It was shown that the streamers radiate relatively short wavelength light (${\sim}340nm$) while the leaders radiate a plenty of long wave length light ($400{\sim}800nm$). It was also known that the streamers propagate very fast with a velocity of $6{\times}l0^7cm/sec$ but the leaders have average velocity of $5{\times}10^6cm/sec$ and they proceed gradually fast by step-wise development.

  • PDF

암성 상복부 통증 환자의 내장신경 차단시 관찰한 체열촬영 소견 (Thermographic Finding at Splanchnic Nerve Block for Cancer Pain)

  • 이상훈;우남식;이예철
    • The Korean Journal of Pain
    • /
    • 제7권1호
    • /
    • pp.59-64
    • /
    • 1994
  • Splanchnic nerve block is effective in relief of upper abdominal cancer pain. But we often get confused at the unexpected complaints of pain accompanying a metastatic of referred origin in spite of the precise block under image intensifier. We could found aut a thermographic change from the diffuse hyperemission state of abdomen before the block to the localized state after the block. It may be helpful in differentiating objectively the accuracy of the block at the unexpected complaints of pain by using thermography before and after the block.

  • PDF

내장 신경 차단후 합병된 양측 서혜부의 지각 탈실 (Dysaesthesia of Inguinal Area Following Splanchnic Nerve Block with Alcohol)

  • 이자원;윤덕미;오흥근
    • The Korean Journal of Pain
    • /
    • 제7권1호
    • /
    • pp.116-118
    • /
    • 1994
  • 무수 알코올로 내장신경차단 완료후 양측 서혜부 상하의 지각 탈실, 이상감감이 합병되었다, 차단 6일 후부터 지속적 경막외차단을 시작하여 점차 이상감각 및 통증은 조절되었으며 지각탈실 부위도 점차 축소되었다.

  • PDF

X-ray microtomography를 이용한 치아의 3차원 재구성 (THREE DIMENSIONAL RECONSTRUCTION OF TEETH USING X-RAY MICROTOMOGRAPHY)

  • 신동훈
    • Restorative Dentistry and Endodontics
    • /
    • 제28권6호
    • /
    • pp.485-490
    • /
    • 2003
  • Complete understanding of the exterior and interior structure of the tooth would be prerequisite to the successful clinical results, especially in the restorative and endodontic treatment. Although three-dimensional reconstruction method using x-ray microtomography could not be used in clinical cases, it may be the best way to reconstruct the morphologic characteristics of the tooth structure in detail without destructing the tooth itself. This study was done to three dimensionally reconstruct every teeth in the arch in order to increase the understanding about the endodontic treatment and to promote the effective restorative treatment by upgrading the knowledge of the tooth morphology. After placing tooth between the microfocus x-ray tube and the image intensifier to obtain two-dimensional images of each level. scanning was done under the condition of 80 keV, $100{\;}\mu\textrm{m}$, 16.8 magnification with the spot size of $8{\;}\mu\textrm{m}$. Cross-section pixel size of $16.28{\;}\mu\textrm{m}$ and 48.83 cross-section to cross-section distance were also used. From the results of this study, precise three dimensional reconstructed images of every teeth could be obtained. Furthermore, it was possible to see image that showed interested area only, for example. enamel portion only, pulp and dentin area without enamel structure, pulp only, combination image of enamel and pulp, etc. It was also possible to see transparent image without some part of tooth structure. This image might be used as a guide when restoring and preparing the full and partial crown by showing the positional and morphological relationship between the pulp and the outer tooth structure. Another profit may be related with the fact that it would promote the understanding of the interior structure by making observation of the auto-rotating image of AVI file from the various direction possible.