• Title/Summary/Keyword: Image guided implant

Search Result 16, Processing Time 0.026 seconds

Time efficiency and operator convenience of using a micro-screw in image registration for guided implant surgery (마이크로스크류가 가이드 임플란트 수술을 위한 영상정합 과정에서 작업시간과 술자편의성에 미치는 영향)

  • Mai, Hai Yen;Lee, Du-Hyeong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.57 no.3
    • /
    • pp.219-224
    • /
    • 2019
  • Purpose: The image registration of radiographic image and digital surface data is essential in the computer-guided implant guide system. The purpose of this study was to examine the effects of using micro-screw on the working time and convenience of operators in the process of image matching for guided implant surgery. Materials and methods: A mandibular dental model was prepared in partial edentulism for Kennedy class I classification. Two micro-screws were placed on the each side of retromolar area. Radiographic and scan images were taken using computed-tomography and digital scanning. The images were superimposed by 12 operators in software in two different conditions: using remaining teeth image alone and using teeth and micro-screws images. Working time, operator convenience and satisfaction were obtained, and analyzed using the Mann-Whitney U test (${\alpha}=.05$). Results: The working time was not statistically different between image registration conditions (P>.05); however, operator convenience and satisfaction were higher in the teeth and micro-screw assisted condition than in the teeth-alone assisted condition (P<.001). Conclusion: The use of micro-screw for the image registration has no effect in working time reduction, but improves operator convenience and satisfaction.

Registration of 3D CT Data to 2D Endoscopic Image using a Gradient Mutual Information based Viewpoint Matching for Image-Guided Medialization Laryngoplasty

  • Yim, Yeny;Wakid, Mike;Kirmizibayrak, Can;Bielamowicz, Steven;Hahn, James
    • Journal of Computing Science and Engineering
    • /
    • v.4 no.4
    • /
    • pp.368-387
    • /
    • 2010
  • We propose a novel method for the registration of 3D CT scans to 2D endoscopic images during the image-guided medialization laryngoplasty. This study aims to allow the surgeon to find the precise configuration of the implant and place it into the desired location by employing accurate registration methods of the 3D CT data to intra-operative patient and interactive visualization tools for the registered images. In this study, the proposed registration methods enable the surgeon to compare the outcome of the procedure to the pre-planned shape by matching the vocal folds in the CT rendered images to the endoscopic images. The 3D image fusion provides an interactive and intuitive guidance for surgeon by visualizing a combined and correlated relationship of the multiple imaging modalities. The 3D Magic Lens helps to effectively visualize laryngeal anatomical structures by applying different transparencies and transfer functions to the region of interest. The preliminary results of the study demonstrated that the proposed method can be readily extended for image-guided surgery of real patients.

Chest Wall Lipogranuloma after Hydrogel Implant Rupture: Case Report

  • Park, So Yoon;Han, Boo-Kyung;Cho, Eun Yoon;Bang, Sa-Ik
    • Investigative Magnetic Resonance Imaging
    • /
    • v.19 no.3
    • /
    • pp.191-195
    • /
    • 2015
  • We present a 53-year-old woman with a large chest wall mass in the interpectoral space, which was eventually confirmed as a lipogranuloma resulting from hydrogel implant rupture. Ultrasonography (US) showed reduced implant volume with surrounding peri-implant fluid collection, suggesting the possibility of implant rupture. A heterogeneously hypoechoic mass was found between the pectoralis major and minor muscles adjacent to the ruptured implant. On magnetic resonance imaging (MRI), there was a large mass in the left interpectoral space of the upper inner chest wall. The mass showed slightly high signal intensity (SI) on pre-contrast T1-weighted image (WI) with mixed iso and high SI on T2-WI. The signal of the mass was suppressed using the water suppression technique but not with the fat suppression technique on T2-WI. The mass showed diffuse enhancement upon contrast enhancement. The enhancing kinetics showed persistent enhancement pattern. US-guided core needle biopsy revealed a lipogranuloma and removal confirmed a ruptured PIP hydrogel implant.

Comparison of accuracy between free-hand and surgical guide implant placement among experienced and non-experienced dental implant practitioners: an in vitro study

  • Dler Raouf Hama;Bayad Jaza Mahmood
    • Journal of Periodontal and Implant Science
    • /
    • v.53 no.5
    • /
    • pp.388-401
    • /
    • 2023
  • Purpose: This study investigated the accuracy of free-hand implant surgery performed by an experienced operator compared to static guided implant surgery performed by an inexperienced operator on an anterior maxillary dental model arch. Methods: A maxillary dental model with missing teeth (No. 11, 22, and 23) was used for this in vitro study. An intraoral scan was performed on the model, with the resulting digital impression exported as a stereolithography file. Next, a cone-beam computed tomography (CBCT) scan was performed, with the resulting image exported as a Digital Imaging and Communications in Medicine file. Both files were imported into the RealGUIDE 5.0 dental implant planning software. Active Bio implants were selected to place into the model. A single stereolithographic 3-dimensional surgical guide was printed for all cases. Ten clinicians, divided into 2 groups, placed a total of 60 implants in 20 acrylic resin maxillary models. Due to the small sample size, the Mann-Whitney test was used to analyze mean values in the 2 groups. Statistical analyses were performed using SAS version 9.4. Results: The accuracy of implant placement using a surgical guide was significantly higher than that of free-hand implantation. The mean difference between the planned and actual implant positions at the apex was 0.68 mm for the experienced group using the free-hand technique and 0.14 mm for the non-experienced group using the surgical guide technique (P=0.019). At the top of the implant, the mean difference was 1.04 mm for the experienced group using the free-hand technique and 0.52 mm for the non-experienced group using the surgical guide technique (P=0.044). Conclusions: The data from this study will provide valuable insights for future studies, since in vitro studies should be conducted extensively in advance of retrospective or prospective studies to avoid burdening patients unnecessarily.

Implant surgery based on computer simulation surgical stent and the assessment with the image fusion technique (컴퓨터 시뮬레이션 기반의 외과용 스텐트를 이용한 임플란트 시술과 영상융합기술을 이용한 평가)

  • Lee, Jee-Ho;Kim, Soung-Min;Paeng, Jun-Young;Kim, Myung-Jin
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.36 no.5
    • /
    • pp.402-407
    • /
    • 2010
  • Introduction: The planning of implant surgery is an important factor for the implant prosthesis. Stereolithographic (SLA) surgical stents based on a computer simulation are quite helpful for clinicians to perform the surgery as planned. Although many clinical and technical trials have been performed for computed tomography (CT)-guided implant stents to improve the surgical procedures and prosthetic treatment, there are still many problems to solve. We developed a system of a surgical guide based on 3 dimensional (3D) CT for implant therapy and achieved satisfactory results in the terms of planning and operation. Materials and Methods: Fifteen patients were selected and 30 implant fixtures were installed. The preoperative CT data for surgical planning were prepared after obtaining informed consent. Surgical planning was performed using the simulation program, Ondemend3D In2Guide. The stents were fabricated based on the simulation data containing information of the residual bone, the location of the nerve, and the expected design of the prostheses. After surgery with these customized stents, the accuracy and reproducibility of implant surgery were evaluated based on the computer simulation. The data of postoperative CT were used to confirm this system using the image fusion technique and compare the implant fixtures between the planned and implanted. Results: The mean error was 1.18 (${\pm}0.73$) mm at the occlusal center, 1.23 (${\pm}0.67$) mm at the apical center, and the axis error between the two fixtures was $3.25^{\circ}C$ (${\pm}3.00$). These stents showed superior accuracy in maxilla cases. The lateral side error at the apical center was significantly different from the error at the occlusal center but there were no significant differences between the premolars, 1st molars and 2nd molars. Conclusion: SLA surgical stents based on a computer simulation have the satisfactory accuracy and are expected to be useful for accurate planning and surgery if some errors can be improved.

Accuracy of 5-axis precision milling for guided surgical template (가이드 수술용 템플릿을 위한 5축 정밀가공공정의 정확성에 관한 연구)

  • Park, Ji-Man;Yi, Tae-Kyoung;Jung, Je-Kyo;Kim, Yong;Park, Eun-Jin;Han, Chong-Hyun;Koak, Jai-Young;Kim, Seong-Kyun;Heo, Seong-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.4
    • /
    • pp.294-300
    • /
    • 2010
  • Purpose: The template-guided implant surgery offers several advantages over the traditional approach. The purpose of this study was to evaluate the accuracy of coordinate synchronization procedure with 5-axis milling machine for surgical template fabrication by means of reverse engineering through universal CAD software. Materials and methods: The study was performed on ten edentulous models with imbedded gutta percha stoppings which were hidden under silicon gingival form. The platform for synchordination was formed on the bottom side of models and these casts were imaged in Cone beam CT. Vectors of stoppings were extracted and transferred to those of planned implant on virtual planning software. Depth of milling process was set to the level of one half of stoppings and the coordinate of the data was synchronized to the model image. Synchronization of milling coordinate was done by the conversion process for the platform for the synchordination located on the bottom of the model. The models were fixed on the synchordination plate of 5-axis milling machine and drilling was done as the planned vector and depth based on the synchronized data with twist drill of the same diameter as GP stopping. For the 3D rendering and image merging, the impression tray was set on the conbeam CT and pre- and post- CT acquiring was done with the model fixed on the impression body. The accuracy analysis was done with Solidworks (Dassault systems, Concord, USA) by measuring vector of stopping’s top and bottom centers of experimental model through merging and reverse engineering the planned and post-drilling CT image. Correlations among the parameters were tested by means of Pearson correlation coefficient and calculated with SPSS (release 14.0, SPSS Inc. Chicago, USA) ($\alpha$ = 0.05). Results: Due to the declination, GP remnant on upper half of stoppings was observed for every drilled bores. The deviation between planned image and drilled bore that was reverse engineered was 0.31 (0.15 - 0.42) mm at the entrance, 0.36 (0.24 - 0.51) mm at the apex, and angular deviation was 1.62 (0.54 - 2.27)$^{\circ}$. There was positive correlation between the deviation at the entrance and that at the apex (Pearson Correlation Coefficient = 0.904, P = .013). Conclusion: The coordinate synchronization 5-axis milling procedure has adequate accuracy for the production of the guided surgical template.

Development and application of stent-based image guided navigation system for oral and maxillofacial surgery (구강외과 수술용 스텐트 기반 영상유도 수술 시스템의 개발)

  • Lee, Woo-Jin;Kim, Dae-Seung;Yi, Won-Jin;Lee, Sam-Sun;Choi, Soon-Chul;Heo, Min-Suk;Huh, Kyung-Hoe;Kim, Myung-Jin;Lee, Jee-Ho
    • Imaging Science in Dentistry
    • /
    • v.39 no.3
    • /
    • pp.149-156
    • /
    • 2009
  • Purpose : The purpose of this study was to develop a stent-based image guided surgery system and to apply it to oral and maxillofacial surgeries for anatomically complex sites. Materials and Methods : We devised a patient-specific stent for patient-to-image registration and navigation. Three-dimensional positions of the reference probe and the tool probe were tracked by an optical camera system and the relative position of the handpiece drill tip to the reference probe was monitored continuously on the monitor of a PC. Using 8 landmarks for measuring accuracy, the spatial discrepancy between CT image coordinate and physical coordinate was calculated for testing the normality. Results : The accuracy over 8 anatomical landmarks showed an overall mean of $0.56{\pm}0.16\;mm$. The developed system was applied to a surgery for a vertical alveolar bone augmentation in right mandibular posterior area and possible interior alveolar nerve injury case of an impacted third molar. The developed system provided continuous monitoring of invisible anatomical structures during operation and 3D information for operation sites. The clinical challenge showed sufficient accuracy and availability of anatomically complex operation sites. Conclusion : The developed system showed sufficient accuracy and availability in oral and maxillofacial surgeries for anatomically complex sites.

  • PDF

Immediate restorations in a fully edentulous patient utilizing digital system: A case report (완전 무치악 환자에서 디지털 시스템을 이용한 임플란트 즉시 보철수복 증례)

  • Fang, Jeong-Whan;Jeong, Seung-Mi;Kang, Se-Ha;Hwang, Chan-Hyeon;Kim, Dae-Hwan;Choi, Byung-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.53 no.2
    • /
    • pp.157-166
    • /
    • 2015
  • This article describes how to use CBCT and an intraoral scanner in a fully edentulous case that enables the clinician to place implants with flapless guided surgery and to engage prefabricated, customized implant abutments at the time of implant surgery, with only 1 clinical consultation before implant surgery. The patient's existing denture is used to simulate the teeth, the soft tissue and the vertical dimension of occlusion, and jaw relationship in the fully edentulous jaw. It provides clinicians with a fast workflow and improves clinical efficiency.

Open healing of contained and non-contained extraction sockets covered with a ribose cross-linked collagen membrane: a pilot study

  • Friedmann, Anton;Meskeleviciene, Viktorija;Yildiz, Mehmet Selim;Gotz, Werner;Park, Jung-Chul;Fischer, Kai R.
    • Journal of Periodontal and Implant Science
    • /
    • v.50 no.6
    • /
    • pp.406-417
    • /
    • 2020
  • Purpose: This study investigated whether the placement of ribose cross-linked collagen (RCLC) membranes without primary soft tissue closure predictably resulted in sufficient alveolar ridge preservation in contained and non-contained extraction sockets. Methods: Membranes were positioned across extraction sockets, undermining full-thickness flaps, and the gingival margins were fixed by double-interrupted sutures without crossed horizontal mattress sutures for 1 week. In non-contained sockets, a bone substitute was used to support the membrane within the bony envelope. Radiographs and clinical images obtained 4 months later were analyzed by ImageJ software using non-parametric tests. Results: In 18 patients, 20 extraction sockets healed uneventfully and all sites received standard-diameter implants (4.1, 4.8, or 5.0 mm) without additional bone augmentation. Soft tissues and the muco-gingival border were well maintained. A retrospective analysis of X-rays and clinical photographs showed non-significant shrinkage in the vertical and horizontal dimensions (P=0.575 and P=0.444, respectively). The new bone contained vital bone cells embedded in mineralized tissues. Conclusions: Within the limitations of this pilot study, open healing of RCLC membranes may result in sufficient bone volume for implant placement without additional bone augmentation in contained and non-contained extraction sockets.

Study on the histomorphometry of guided bone regeneration using automated image analysis system (자동 영상분석 계기를 이용한 골 유도재생능력의 분석에 관한 조직계측학적 연구)

  • Kim, T.I.;Ku, Y.;Rhyu, I.C.;Chung, C.P.;Han, S.B.;Choi, S.M.;Son, S.H.
    • Journal of Periodontal and Implant Science
    • /
    • v.26 no.3
    • /
    • pp.771-778
    • /
    • 1996
  • The assessment of alveolar bone changes on dental radiographs to indicate progression of periodontal diseases or healing response to therapy is routine procedure. However, the diagnostic accuracy in detecting small alveolar bone changes is very limited. Recently, guided bone regeneration therapy is popular, but the quantification of new bone is somewhat difficult with conventional evaluation method. To quantificate the amount of new bone, various evaluating methods have been introduced including histomorphometry, radiomorphometry, biochemical analysis, X-ray probe microanalysis, scanning electron microscope backscatter method. In this study, guided bone regeneration using resorbable membrane with & without PDGF-BB is quatificated through histomorphmetry to evaluate the efficacy of histomorphometric analysis. 4 beagle dogs and 8 Sprague-Dawley rats were selected as experimental animals. In beagle dog experiment, $4{\times}4mm$ Class II defects were created in maxillary both second premolars, and biodegradable membrane containing PDGF-BB(experimental group) were covered over one defect, and same membrane without PDGF-BB(control group) were covered over the other defect. At 2 weeks, 5 weeks after surgery, each beagle dogs were sacrificed, and the tissues were treated by undecalcified fixation. In Sprague-Dawley rat experiment, 5mm round defect were created in temporal bone, the same membranes were covered on the defects. At 1 week, 2 weeks after surgery, each rats were sacrificed, and undecalcified fixation were taken. After grinding tissue specimen, we analyse them histomorphometrically using image analysis system. In beagle dog 2 weeks specimens, new bone formation area were $0.03123mm^2$ in experimental group,and $0.03012mm^2$ in control group. At 5 weeks specimens, $0.15324mm^2$ in experimental group, and $0.09123mm^2$ in control group. In Sprague-Dawley rat specimens, new bone fomation area were $0.20448mm^2$ in 1 week experimental group, $0.03604mm^2$ in 1 week control group. At 2 weeks specimens, $0.46349mm^2$ in experimental group, $0.17741mm^2$ in control group. The results indicated that histomorphometric analysis of new bone formation using image analysis system is very effective quantification method to evaluate the efficacy of treatment modalities.

  • PDF