• 제목/요약/키워드: Image detector data

검색결과 205건 처리시간 0.026초

적외선 센서를 이용한 열상장비의 구현 (Thermal Imager Implementation Using Infrared Sensor)

  • 유위경;윤은숙;김창우;송인섭;홍석민
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 B
    • /
    • pp.1250-1254
    • /
    • 1992
  • This paper describes the designed and fabricated thermal imaging system with the SPRITE(Signal PRocessing in The Element) detector, operating in the 3-12 micron band. This system consists of an afocal telescope, a scan unit containing the SPRITE detector, an electronic processor unit and a cooler. The optical scan system utilizing rotating polygon and oscillating mirror, is 2-dimensional serial/parallel scan type using five elements of the detector. And the electronic processor unit performs digital scan conversion to reform the parallel data stream into serial analog data compatable with conventional RS-170 video. The scan field of view is 40 ${\times}$ 26.7 and the MRTD(Minium Resolvable Temperature Difference) is 0.6 K at 7.5 cycles/mm. The acquired thermal image indicates that this system has a satisfactory performance.

  • PDF

영상검지기 교정주기 설정방안 (Video Image Detector Calibration Period Decision)

  • 이청원;백남철;송영화;장진환
    • 대한교통학회지
    • /
    • 제23권5호
    • /
    • pp.177-185
    • /
    • 2005
  • 각종 환경적, 기술적 요인으로 인하여 영상검지기는 사용연한에 따라 정확도는 감소하기 마련인데 변화정도에 대해서 체계적으로 연구된 바가 없다. 영상검지기의 정확도를 적정수준으로 유지하기 위해서는 교정작업이 필수적이지만 예산적, 제도적 문제로 인해 엄밀한 교정이 실시되지 못해 양질의 교통관리에 제약으로 작용하고 있다. 본 연구는 실제 현장에서 쓰이고 있는 영상검지기들을 대상으로 정확도 검사방안을 개발하였고, 현장 조사를 통해 수집된 자료를 기반으로 최적 교정주기 설정방안을 개발하였다. 이는 정보의 질을 중시하는 ITS센터의 유지관리업무와 연계하여 정책적으로도 활용될 수 있을 것이다.

Impact of Photon-Counting Detector Computed Tomography on Image Quality and Radiation Dose in Patients With Multiple Myeloma

  • Alexander Rau;Jakob Neubauer;Laetitia Taleb;Thomas Stein;Till Schuermann;Stephan Rau;Sebastian Faby;Sina Wenger;Monika Engelhardt;Fabian Bamberg;Jakob Weiss
    • Korean Journal of Radiology
    • /
    • 제24권10호
    • /
    • pp.1006-1016
    • /
    • 2023
  • Objective: Computed tomography (CT) is an established method for the diagnosis, staging, and treatment of multiple myeloma. Here, we investigated the potential of photon-counting detector computed tomography (PCD-CT) in terms of image quality, diagnostic confidence, and radiation dose compared with energy-integrating detector CT (EID-CT). Materials and Methods: In this prospective study, patients with known multiple myeloma underwent clinically indicated whole-body PCD-CT. The image quality of PCD-CT was assessed qualitatively by three independent radiologists for overall image quality, edge sharpness, image noise, lesion conspicuity, and diagnostic confidence using a 5-point Likert scale (5 = excellent), and quantitatively for signal homogeneity using the coefficient of variation (CV) of Hounsfield Units (HU) values and modulation transfer function (MTF) via the full width at half maximum (FWHM) in the frequency space. The results were compared with those of the current clinical standard EID-CT protocols as controls. Additionally, the radiation dose (CTDIvol) was determined. Results: We enrolled 35 patients with multiple myeloma (mean age 69.8 ± 9.1 years; 18 [51%] males). Qualitative image analysis revealed superior scores (median [interquartile range]) for PCD-CT regarding overall image quality (4.0 [4.0-5.0] vs. 4.0 [3.0-4.0]), edge sharpness (4.0 [4.0-5.0] vs. 4.0 [3.0-4.0]), image noise (4.0 [4.0-4.0] vs. 3.0 [3.0-4.0]), lesion conspicuity (4.0 [4.0-5.0] vs. 4.0 [3.0-4.0]), and diagnostic confidence (4.0 [4.0-5.0] vs. 4.0 [3.0-4.0]) compared with EID-CT (P ≤ 0.004). In quantitative image analyses, PCD-CT compared with EID-CT revealed a substantially lower FWHM (2.89 vs. 25.68 cy/pixel) and a significantly more homogeneous signal (mean CV ± standard deviation [SD], 0.99 ± 0.65 vs. 1.66 ± 0.5; P < 0.001) at a significantly lower radiation dose (mean CTDIvol ± SD, 3.33 ± 0.82 vs. 7.19 ± 3.57 mGy; P < 0.001). Conclusion: Whole-body PCD-CT provides significantly higher subjective and objective image quality at significantly reduced radiation doses than the current clinical standard EID-CT protocols, along with readily available multi-spectral data, facilitating the potential for further advanced post-processing.

Novel Structure of 21.6 inch a-Si:H TFT Array for the Direct X-ray Detector

  • Kim, Jong-Sung;Joo, In-Su;Choo, Kyo-Seop;Park, June-Ho;Chung, In-Jae
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2000년도 제1회 학술대회 논문집
    • /
    • pp.13-14
    • /
    • 2000
  • 21.6" a-Si:H TFT array for direct conversion X-ray detector with 2480 by 3072 pixel is successfully developed. To obtain good X-ray image quality, novel structure, storage on BCB structure, is proposed. The structure reduces the parasitic capacitance of data line, one of the main sources of signal noise. Also, the structure shows higher failure resistance against defects than that of the old design.

  • PDF

위성용 전자광학시스템 카메라전자부의 인터페이스 설계 (Interface Design of Camera Electronic Module for a Satellite Eletro-Optic System)

  • 공종필;김보관
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2008년도 하계종합학술대회
    • /
    • pp.1157-1158
    • /
    • 2008
  • This paper describes the interface designs of Optical-Camera Electronic unit with a DFPA(Detector Focal Plane Assembly) and IDHU(Image Data Handling Unit) which meet the top-level requirement of a satellite system. Especially, the designs on the image format and timing of the Header information for the correct reconstruction of the image in the Groundstation are explained in detail.

  • PDF

Reference based simulation study of detector comparison for BNCT-SPECT imaging

  • Kim, Moo-Sub;Shin, Han-Back;Choi, Min-Geon;Monzen, Hajime;Shim, Jae Goo;Suh, Tae Suk;Yoon, Do-Kun
    • Nuclear Engineering and Technology
    • /
    • 제52권1호
    • /
    • pp.155-163
    • /
    • 2020
  • To investigate the optimal detector material for prompt gamma imaging during boron neutron capture therapy, in this study, we evaluated the characteristic regarding radiation reaction of available detector materials using a Monte Carlo simulation. Sixteen detector materials used for radiation detection were investigated to assess their advantages and drawbacks. The estimations used previous experimental data to build the simulation codes. The energy resolution and detection efficiency of each material was investigated, and prompt gamma images during BNCT simulation were acquired using only the detectors that showed good performance in our preliminary data. From the simulation, we could evaluate the majority of detector materials in BNCT and also could acquire a prompt gamma image using the six high ranked-detector materials and lutetium yttrium oxyorthosilicate. We provide a strategy to select an optimal detector material for the prompt gamma imaging during BNCT with three conclusions.

Combined X-ray CT-SPECT System with a CZT Detector

  • Kwon, Soo-Il;Koji Iwata;Hasegawa, B-H
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.379-381
    • /
    • 2002
  • A single CdZnTe detector is tested for suitability in a prototype CT/ SPECT system designed to acquire both emission and transmission data. The detector has the size of 1${\times}$l-cm$^2$ with 4${\times}$4 1.5${\times}$l.5mm$^2$ pixellated anodes. Since the detector is smaller than imaged object, we translated it in an arc centered at the x-ray tube to image larger objects. Pulse counting electronics with very short shaping time (50 ns) are used to satisfy high photon rates in x-ray imaging, and response linearity up to 3${\times}$10$\^$5/ counts per second per detector element is achieved. The energy resolution of 122-keV gamma-ray is measured to be 14%. We have characterized the system performance by scanning a radiographic resolution phantom .and the Hoffman brain phantom. The spatial resolution of CT and SPECT are about 1 mm and 7 mm, respectively.

  • PDF

FEASIBILITY OF IMAGE PROCESSING TECHNIQUES FOR LAKE LEVEL EXTRACTION WITH C-BAND SRTM DEM

  • Bhang, Kon-Joon;Schwartz, Franklin Walter;Park, Seok-Soon
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2008년도 International Symposium on Remote Sensing
    • /
    • pp.173-176
    • /
    • 2008
  • Lake studies play an important role in water management, ecology, and other environmental issues. Typically, monitoring lake levels is the first step on the lake studies. However, for the Prairie Pothole Region (PPR) of North America having millions of small lakes and potholes, on-site measurement for lake levels is almost impossible with the conventional gage stations. Therefore, we employed Geographic Information System (GIS) and remote sensing approach with the Shuttle Radar Topography Mission data to extract lake levels. Several image processing techniques were used to extract lake levels for January, 2000 as a one-time snapshot which will be useful in historic lake level reconstruction. This study is associated with other remote sensing datasets such as Landsat imagery and Digital Orthophoto Quadrangle (DOQ). In this research, firstly, image processing techniques like FFT filtering, Lee-sigma, masking with Canny Edge Detector, and contouring were tested for lake level estimation. The semi-automated contouring technique was developed to accomplish the bulk processing for large amount of lakes in this region. Also, effectiveness of each method for bulk processing was evaluated.

  • PDF

영상처리를 이용한 여행시간 및 속도 계측 알고리즘의 개발 (The Development for Vision-Based Realtime Speed Measuring Algorithm)

  • 오영태;조형기;정의환
    • 대한교통학회지
    • /
    • 제14권4호
    • /
    • pp.107-129
    • /
    • 1996
  • Recently, surveillance system designed to collect various trsffic information are becoming new areas of development . Among these, the image detector is a ayatem which can measure the travel time and speed in realtime and this is emerging as the most effcient tool to be available in future related areas. But in measuring wide-area information in realtime, the image detector are yet full of problem in its accuracy. The aim of this ahesis is to develop an algorithms which can collect wide-area information such as travel time and travel speed in urban networks and freeways in realtime. The information on wide-area such as travel time and travel speed is important in accomplishing strategic function in traffic control. The algorithm developed from this study is based on the image tracking model which tracks a moving vehicle form image datas collected continuously, and is constructed to perform realtime measurement. To evaluate the performance of the developed algorithms, 600 ind vidual vehicles in total were used as data for the study, and this evaluation was carried out with the differenciation of day and night condition at the access roads in front of AJou University, In the statistical analysis results, the error rate was recorded as 5.69% and it has proved to be applicable on the field in both day and noght conditions.

  • PDF

유사물체 치환증강을 통한 기동장비 물체 인식 성능 향상 (Object Detection Accuracy Improvements of Mobility Equipments through Substitution Augmentation of Similar Objects)

  • 허지성;박지훈
    • 한국군사과학기술학회지
    • /
    • 제25권3호
    • /
    • pp.300-310
    • /
    • 2022
  • A vast amount of labeled data is required for deep neural network training. A typical strategy to improve the performance of a neural network given a training data set is to use data augmentation technique. The goal of this work is to offer a novel image augmentation method for improving object detection accuracy. An object in an image is removed, and a similar object from the training data set is placed in its area. An in-painting algorithm fills the space that is eliminated but not filled by a similar object. Our technique shows at most 2.32 percent improvements on mAP in our testing on a military vehicle dataset using the YOLOv4 object detector.