• Title/Summary/Keyword: Image depth penetration

Search Result 28, Processing Time 0.035 seconds

Analysis of Printed Image Depending on Mixing Ratios of Softwood and Hardwood fibers Using Image Analyzer and CLSM (화상분석기와 CLSM을 이용한 침.활엽수 섬유의 배합비에 따른 인쇄화상 분석)

  • 이장호;박종문
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.34 no.3
    • /
    • pp.25-31
    • /
    • 2002
  • The purpose of this study was to analyze how the fiber properties and mixing ratio of softwood and hardwood pulp affect on roundness of printed image. Softwood pulp and hardwood pulp were refined to 400 and 600ml CSF by Valley beater and handsheets of 70 g/$m^2$ basis weight were made at different mixing ratios of hardwood and softwood pulp. The roundness, dot area, and shape of the printed dot were measured by Image Analyzer. The depths and shapes of the acridine orange penetration into paper were measured by CLSM. With higher mixing ratio of hardwood pulp, the paper showed higher air-permeability and better formation, especially at lower freeness. The roundness of the printed image became better and the dot size became smaller when the amount of hardwood pulp increased. Penetration depth of acridine orange by CLSM became greater and roundness increased to real circle when the amount of hardwood pulp increased. It was thought that higher mixing ratio of hardwood fibers resulted in efficient penetration by better formation with uniform micro-pore distribution and it increased roundness. It was thought that fiber properties and mixing ratio affected the structure of paper and the shape of the printed dot. This study showed that the measurement of depth of the liquid penetration into paper without destruction and contact was feasible. Moreover, this method showed that the shape of the liquid penetration was measurable.

Dentinal tubule penetration of sodium hypochlorite in root canals with and without mechanical preparation and different irrigant activation methods

  • Renata Aqel de Oliveira;Theodoro Weissheimer;Gabriel Barcelos So ;Ricardo Abreu da Rosa ;Matheus Albino Souza;Rodrigo Goncalves Ribeiro ;Marcus Vinicius Reis So
    • Restorative Dentistry and Endodontics
    • /
    • v.48 no.1
    • /
    • pp.1.1-1.11
    • /
    • 2023
  • Objectives: This study evaluated the dentinal penetration depth of 2.5% sodium hypochlorite (NaOCl) in root canals with and without preparation and different irrigant activation protocols. Materials and Methods: Sixty-three bovine mandibular incisors were randomly allocated to 6 groups (n = 10): G1, preparation + conventional needle irrigation (CNI); G2, preparation + passive ultrasonic irrigation (PUI); G3, preparation + Odous Clean (OC); G4, no preparation + CNI; G5, no preparation + PUI; G6, no preparation + OC; and CG (negative control; n = 3). Samples were filled with crystal violet for 72 hours. Irrigant activation was performed. Samples were sectioned perpendicularly along the long axis, 3 mm and 7 mm from the apex. Images of the root thirds of each block were captured with a stereomicroscope and analyzed with an image analysis software. One-way analysis of variance, followed by the Tukey post hoc test, and the Student's t-test were used for data analysis, with a significance level of 5%. Results: The NaOCl penetration depth was similar when preparation was performed, regardless of the method of irrigation activation (p > 0.05). In the groups without preparation, G6 showed greater NaOCl penetration depth (p < 0.05). The groups without preparation had a greater NaOCl penetration depth than those with preparation (p = 0.0019). Conclusions: The NaOCl penetration depth was similar in groups with root canal preparation. Without root canal preparation, OC allowed deeper NaOCl penetration. The groups without preparation had greater NaOCl penetration than those undergoing root canal preparation.

Manufacture and Image Characteristic Changes Observation by Temperature of Ultrasound Tissue Mimicking Phantom (초음파 Tissue Mimicking 팬텀의 제작과 온도 변화에 따른 영상 특성 변화 관찰)

  • Ma, Sang-Chull
    • Journal of radiological science and technology
    • /
    • v.39 no.2
    • /
    • pp.157-161
    • /
    • 2016
  • The purpose of this study is that in measures the acoustic propagate characteristics and temperature sensitivity of ultrasound tissue mimicking phantom(TM phantom). TM phantom manufacture according to the International Electronical Committee(IEC) guidelines for acoustic propagate characteristics of soft tissue. TM phantom was observed to have the image brightness and the image depth penetration decreases changes convergence which was the subject of ultrasound image characteristics in accordance with an external temperature that the change is reduced in temperature below $22^{\circ}C$. This study provide a basis t o create another TM Phantom and TM Phantom has been determined that it is appropriate for use in more than $22^{\circ}C$.

Remote Sensing of Soil Moisture Change Using a Differential Interferometry Technique (차분 간섭 기법을 이용한 지표면 수분함유량 변화 탐지)

  • Park, Sin-Myeong;Oh, Yisok
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.4
    • /
    • pp.459-465
    • /
    • 2013
  • This paper presents a differential interferometry technique for soil moisture change detection by measuring surface-height variation. COSMO-SkyMed SAR images were used to verify the DInSAR(differential interferometric SAR) technique. The soil penetration depth changes according to soil moisture, that causes phase change of the received signal. The height of soil surface and its displacement can be detected by a radar interferometry technique using phase difference of two received signals. To retrieve displacement variation, one of three SAR images is used as a reference image. Reference image and other two images are processed by the differential interferometry technique in the same area. The soil moisture was measured for the test sites to verify the DInSAR technique. The penetration depth is calculated by using the in-situ measured soil moisture data and it is compared with the displacement values acquired by the DInSAR technique.

Quantifying Chloride Ingress in Cracked Concrete Using Image Processing (이미지 분석을 이용한 균열 콘크리트 내 염화물 침투 정량화 평가)

  • Kim, Kun-Soo;Park, Ki-Tae;Kim, Jaehwan
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.4
    • /
    • pp.57-64
    • /
    • 2022
  • Chloride, which is one of the main deterioration factors in reinforced concrete structures, can degrade the performance of the structure due to chloride-induced corrosion of steel. Chloride content at steel depth or the rate of chloride penetration is necessary to determine deterioration of reinforced concrete or to calculate initiation time of steel corrosion caused by chloride attack. Chlorides in concrete are generally identified with typical two methods including chloride profiling using potentiometric titration method and discoloration method using AgNO3 solution. The former is advantageous to estimate chloride penetration rate (diffusion coefficient in general) with measured chloride contents directly, but it is laborious. In the case of latter, while the result is obtained easily with the range of discoloration, the error may occur depending on workmanship when the depth of chloride ingress is measured. This study shows that chloride penetrated depth is evaluated with the results obtained from discoloration method through image analysis, thereby the error is minimized by workmanship. In addition, the effect of micro-crack in concrete is studied on chloride penetration. In conclusion, the depth of chloride penetration was quantified with image analysis and as it was confirmed that chlorides can rapidly penetrate through micro-cracks, caution is especially required for cracks in concrete structure.

Coaxial Monitoring during Laser Lap Welding (겹치기 이음부의 레이저용접 동축 모니터링)

  • Kim, Jung-Hak;Kim, Cheol-Hee;Kim, Jeong-Han;Rhee, Se-Hun
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1294-1298
    • /
    • 2007
  • Welding process monitoring is advantageous for maintaining weld quality and numerous sensing techniques have been developed for laser welding. Coaxial image monitoring enables direct monitoring of the weld pool shape and keyhole behavior, but requires the complex optical system and the image processing technique. In this study, we coaxially acquired the weld pool images during laser lap welding by using the camera and special illumination. The welding characteristics - pool width and length, keyhole shape, etc - were extracted by using image processing and the relationship between these characteristics and the penetration depth were investigated.

  • PDF

Recent Trends of the Material Processing Technology with Laser - ICALEO 2014 Review - (레이저를 이용한 소재가공기술 동향 - ICALEO 2014를 중심으로 -)

  • Lee, Mokyoung
    • Journal of Welding and Joining
    • /
    • v.33 no.4
    • /
    • pp.7-16
    • /
    • 2015
  • New lasers such as high power, high brightness and short wavelength laser are using diverse industry. Also new technologies are developing actively to solve various issues such as spattering, process monitoring, deep penetration and key-hole stability. ICALEO is the international congress where recent technology for laser material processing and laser system are present. At 2014, it was held at San Diego in USA and more than 260 papers were presented from 28 country. The effect of the laser beam shape such as Gaussian like and top-hat was investigated on acoustic emission signal and pore formation in welding. Inline penetration depth was measured with ICI(Inline Coherent Imaging) technique and the data was verified with real time X-ray image on laser welding. The laser welding performance at low pressure environment was evaluated for the thick plate alloy steel. UV laser was used to weld various metals such as Cu, Aluminum, steel and stainless steel. The effect of the wavelength of the laser on the formation of the wave at the wall of the key-hole front and the absorptivity was investigated.

Diagnostic Utilization of Laser Fluorescence for Resin Infiltration in Primary Teeth (유치의 레진침투법을 위한 레이저 형광법의 진단적 활용)

  • Park, Soyoung;Jeong, Taesung;Kim, Jiyeon;Kim, Shin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.46 no.3
    • /
    • pp.265-273
    • /
    • 2019
  • This study was performed to evaluate clinical use of laser fluorescence (LF) to identify early childhood caries lesions suitable for applying resin infiltration. 20 exfoliated primary molars with proximal caries were selected and cut buccolingually cross the central pit for regarding the mesial and distal surfaces respectively. 27 specimens corresponding to ICDAS code 1 and 2 were selected and the LF values were measured. When infiltrant resin was applied, double staining for microscopy detection has done simultaneously. Tooth samples were sliced with 0.7 mm thick. The maximum lesion depth, maximum penetration depth, and average penetration rate were measured from the confocal scanning laser microscope image. Pearson correlation analysis was performed. The intraclass correlation coefficient of LF values shows excellent agreement. LF values had positive correlation with penetration rate, but not lesion depth and penetration depth. Significant correlation between LF readings and penetration rate was verified in deep enamel caries and dentin caries except shallow enamel caries. Infiltrant resin could penetrate with a higher rate and LF values could be increased in more active caries lesions. In assessing radiologically similar caries lesion, laser fluorescence might be useful for identifying caries activity.

Mapping Urban Inundation Using Flood Depth Extraction from Flood Map Image (침수지도 영상의 침수심 추출기법을 활용한 내수 침수 위험지도 작성)

  • Na, Seo Hyeon;Lee, Su Won;Kim, Joo Won;Byeon, Seong Joon
    • Journal of Korean Society of Water Science and Technology
    • /
    • v.26 no.6
    • /
    • pp.133-142
    • /
    • 2018
  • Increasing localized torrential rainfall caused by abnormal climate are making higher damage to human and property through urban inundation So The need of preventive measures is being highlighted. In this study, the methodology for calculating flood depth in domestic water map using an interpolation method in order to utilizing the results of flood analysis provided only in the form of a report is suggested. In the Incheon Metropolitan City S area as the test-bed, the flood depth was calculated using the interpolating the actual flood analysis by image and verification was performed. Verification results showed that the error rate was 5.2% for the maximum flooding depth, and that the water depth value was compared to 10 random points, which showed a difference of less than 0.030 m. Also, as the results of the flood analysis were presented in various ways, the flood depth was extracted from the image of the result of the flood analysis, which changed the presentation method, and then compared and analyzed. The results of this study could be available for the use of basic data from the research on the urban penetration of domestic consumption and for decision-making of policy.

Assessment of Underwater Penetration Performance for the Shape of the External Device of Shaped Charge (성형폭약 외부장치 형상에 따른 수중 관입성능 평가)

  • Suk, Chul-Gi;Noh, You-Song;Ko, Young-Hun;Park, Hoon;Cho, Sang-Ho;Yang, Hyung-Sik
    • Explosives and Blasting
    • /
    • v.34 no.4
    • /
    • pp.1-9
    • /
    • 2016
  • For underwater steel structure, cut that underwater shaped charge device that combines a spring hose, which is an external device of pressure resistance and flexibility with flexible shaped charge, was invented. As a basic experiment for an optimum condition design, an penetration performance was compared by external device shape. To evaluate the result of an experiment, image analysis was carried out after obtaining the model by using the liquid rubber for the penetrated steel plate. To simulate the penetrating process of shaped charge, the AUTODYN program has been used. As a result of analysis, while the average penetration depth of circular and square shaped external devices were similar, the penetration quality was more uniform in the case of circle. In addition, water infiltration occurred in square case, displacement and strain rate according to the increase of the water pressure were measured high.