• Title/Summary/Keyword: Image analyser

Search Result 42, Processing Time 0.037 seconds

Image Analyser을 이용한 종이내의 Pattern 분석사례

  • 손창만;조신환;전성재;이해성;임정우
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 1999.11a
    • /
    • pp.87-91
    • /
    • 1999
  • Image Analyser를 이용하여 종이표면에 존재하는 특정패턴을 조사하여 이 패턴의 유래를 분석 확인하였다. 종이내에 존재하는 패턴을 Image Analyser에 입력하여 2차원 고속 Fourier 변환처리에 의하여 특징을 추출한 후 잡음으로 간주되는 신호를 제거하여 이를 다시 화상으로 변환시켰다. 재구성된 화상의 패턴이 잡음이 아닌 것을 확인한 후, 이 패턴이 초지기상의 어느부분에서 유래되었는가를 조사.분석하였다. 나아가 이를 바탕으로 초지기의 특정부분의 제반조건을 재설정.조정함으로써 종이품질의 향상은 물론 생산성 향상에도 기여하게 되었다.

  • PDF

New Evaluation System of Cosmetic Effects on Morphology of Skin Surface Using TSRLM with Image Analyser

  • Kim, Jong-Il;Lee, Joa-Hoon;Lee, Yoo-Young;Kim, Chang-Kew
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.16 no.1
    • /
    • pp.47-63
    • /
    • 1990
  • Image analyser was used to understand the condition of skin surface and to evaluate the efficacy of cosmetic treatment. It was unsatisfactory to analyse skin surface structure although several methods using image analyser had been presented. We developed the new system composed of image analyser and Tandem Scanning Reflected Light Microscope (TSRLM) having the remarkable optical sectioning property as image input device. By using this new system, we quantitatively measured the change of skin surface, the depth and width of furrow in micron unit, resulted by cosmetic treatments. And also three dimensional image of skin was reconstructed with serial sectioned images, which were captured through TSRLM, for better understanding of the effect of cosmetic treatment. It was found that skin relief was more easily understood and the change of skin surface caused by cosmetic treatment was more accurately measured by using this system. In addition, we was also aware of the possibility of in vivo direct measurement of skin furrow without replica. It was conceivable that our system could be applicable for study of cosmetic effects further.

  • PDF

Analysis of Medical Image with CD-RAD Phantom (CD-RAD Phantom을 이용한 의료영상의 분석)

  • Kim, Chang-Bok;Kim, Young-Keun;Cho, Yong-Sung;Lee, Kyung-Sup
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.369-369
    • /
    • 2007
  • The physical and visual evaluation of the identical X-rays are analyzed for medical image clarity with CD-RAD Phantom on this study. The method of measurement is to research CD-RAD by X-rays and to acquire images through image processing equipment, the image analyses are carried out by physical evaluation with statistical method through CD-RAD analyser program, and the visual evaluation of the identical X-rays is carried out by blind test for 20 observers. The result of it is that IQF value of the physical evaluation of Contrast-detail curve is 25 and IQF value of the visual evaluation is 30, so it is revealed that the physical evaluation is superior to the visual one. The special qualities of medical images have much importance of the transmission capacity of information to the image analyser, so it is concluded that 0비ective methods of the physical and visual analyses should be carried out side by side.

  • PDF

Dimensions of Structural Elements in Fusiform Ray of Sitka Spruce (Picea sitchensis (Bong.) Carr.) Affecting Radial Permeability

  • Usta, Ilker
    • Journal of the Korean Wood Science and Technology
    • /
    • v.33 no.5 s.133
    • /
    • pp.1-6
    • /
    • 2005
  • The anatomical structure of fusiform ray was examined by scanning electron microscopy (and microscopic images were analysed by image analyser) to explain the differences in radial fluid uptake between the extremes in the radial treatment data, i.e. between the selected trees of QCI (Queen Charlotte Islands in Rhondda, South Wales) and SO (South Oregon in Dalby, North-East England) planted in the UK. The ray structure of these two seed origins was examined microscopically and different patterns of ray composition were observed. The most important anatomical features influencing radial permeability were the nature of fusiform ray, and the condition of the resin canals, epithelial cells and intercellular spaces in particular.

Morphological Measurement of the Spermatogenic Cells in the Korean Native Pheasant(Phasianus colchicus korpowi) with Image Analyser (영상분석기를 이용한 한국산 꿩의 정자발생세포들의 형태학적 계측)

  • 박영석;양홍현;김인식
    • Korean Journal of Animal Reproduction
    • /
    • v.23 no.1
    • /
    • pp.37-43
    • /
    • 1999
  • The image analyser was used for the measurement of the morphological changes of the spermatogenic cells and seminiferous tubules in the pheasant during the breeding and non breeding season. 1. The seminiferous tubules were enlarged 2.57 times during the breeding season than during the non breeding season. Only Sertoli cells and spermatogonia in the seminiferous tubules can be found during the non breeding season. 2. There is no significantly difference in the ratio of nucleus area against that of cell size in the spermatogonium between breeding and non breeding season. The ratio of area was 28.71% and 29.11%, respectively. However, the enlargement of spermatogonium was noticed during the non breeding season. 3. The highest value of the ratio of the nucleus area against that of cell size among the germ cells was measured 37.40% in the pachytene phase of the spermatocyte during the breeding season. 4. The ratio of nucleus area against that of cell size in the spermatid was 22.53%.

  • PDF

Developing Management System of Medical Image Information with USB 2.0 (USB 2.0을 활용한 의료 영상정보 관리시스템 개발)

  • Choi, Jung-Sang
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.29 no.2
    • /
    • pp.51-57
    • /
    • 2006
  • This study is concerned with image information management system for small scale hospital. We intended to developing image management system which is used of the existing analog devices such as medical camera, supersonic analyser, endoscope etc. We developed a video in interface board based USB 2.0 for handling image in real time. It is capable of transmitting image input signal like as NTSC, PAL to personal computer through USB 2.0. The developed the board of 40 speeds compared with the exiting system based USB 1.0. Especially the developed system is very helpful for small hospital like as dental clinic, because it is easy and convenient to manage image information without expert. So it will provide reduction of time and cost for handling image information(collecting, saving, retrieval, transmitting image).

The Manufacturing of Electromagnetic Shielding Sheet Using the Carbon and Wood Fiber Mixture (탄소와 목재섬유 혼합물을 이용한 전자기파 차폐용 시트의 제조)

  • Kim, Hyoung-Jin;Um, Gi-Jeung
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.38 no.4 s.117
    • /
    • pp.68-75
    • /
    • 2006
  • Electromagnetic shielding sheet using the carbon and wood fiber mixture was manufactured in an effort to develop an electromagnetic shielding packaging material. Carbon fibers were cut into 5, 10, and 15 mm using the automatic cutting device and blown and dispersed using compression air passed through the fine nozzle. Then carbon fibers were slurried with water (0.1% consistency), and softwood kraft pulp along with cone starch were added. The wet mats were manufactured by dewatering in modified hand-sheet machine. The wet mats were pressed upto $4kgf/cm^2$ in the carbon and wood fiber mixture mat press. The wet mats were dried in the automatic controlled plate dryer. Investigation on the formation and surface structure of the newly developed carbon and wood fiber mixture electromagnetic shielding sheet were carried out using the scanning electron microscopy and the image analyzer. Finally electromagnetic shielding characteristics of the newly developed carbon and wood mixture sheet were measured using net-work analyser. The result was promising in the light of the fact that this method could open a new way to substitute the expensive imported electromagnetic shielding sheet.

A STUDY ON THE GLOSS AND ROUGHNESS OF THE COMPOSITE RESIN (복합레진의 광택 및 표면조도에 관한 연구)

  • Cho, Seung-Joo;Lee, Myung-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.15 no.1
    • /
    • pp.67-80
    • /
    • 1990
  • This study was performed for elucidating the effects on surface polishing of composite resins. In this study, Silux(microfilled), Graft(hybrid), Bisfil- I (hybrid posterior) and Hi-pol(conventional) were used. Sixty specimens were made with 4 brands of composite resins and Optilux system in $2.0{\times}1.3{\times}1.0cm$ resin block which has a cavity with 0.5cm diameter and 0.5cm depth. Polishing was done with #600 sand paper and Soflex, Super-snap, Micron finishing system, or Composite polishing kit. Final polished surfaces were measured by roughness tester(Kasaka Lab. Ltd., Japan) and image analyser(Omnimet Image Analyser, Buehler, USA). The results were as follows, 1. The celluloid strip produced the smoothest surfaces. 2. Light curing microfilled composite resin, Silux, had smoother surface than any others. 3. The surfaces polished by Soflex were smoothest. 4. Aluminum oxide disk, Soflex and Super-Snap, made smoother surface than diamond bur, M.F.S., or silicon point, Composite polishing kit. 5. The roughness values of surface polished by M.F.S. composed of diamond burs, were less than those of Composite polishing kit made from silicone points.

  • PDF

Next Generation Fiber Length Measurement

  • Tiikkaja, Esa;Sopenlehto, Taina
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.32 no.5
    • /
    • pp.54-59
    • /
    • 2000
  • The next generation fibre size analyser has been developed in Kajaani based on over 15 years experience in fibre measurement. This new FiberLab-analyser can measure fibre length both along the fibre centre line and as projected. The cross-sectional measurements of fibre are in principle similar to the earlier version FiberLab. Measured data are generally displayed in distributions. Some new calculations have been added, for example the fibres cross sectional area and fibre volume index both available as distributions as well. The performance of the FiberLab measurement is verified against the manual microscopic testing. These tests show that the new image analysis-based measurement well matches with the manual methods.

  • PDF

Micro Sampling System for Highly Radioactive Specimen by Laser Ablation (Laser Ablation에 의한 고방사성시편의 미세영역 시료채취 장치개발)

  • Han Sun Ho;Ha Yeong Keong;Han Ki Chul;Park Yang Soon;Jee Kwang Yong;Kim Won Ho
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.3 no.1
    • /
    • pp.17-21
    • /
    • 2005
  • Shielded laser ablation system composed of laser system, image analyser, XYZ translator with motion controller, ablation chamber, manipulator and various optics was designed. Nd:YAG laser which can be tunable from 1064 nm to 266 m was selected as light source. CCD camera(< $\pm$200) was chosen to analyze a crater less than 50 un in diameter. XYZ translator was composed of three linear stage which can travel 50 w with a minimum movement of 1 um and motion controller. Before the performance test, each part of system was optically aligned. To perform the ablation test, the specimen was ablated by 50 um interval and observed by image analyser The shape of crater was almost round, indicating laser beam has homogeneous energy distribution. The resolution and magnification of image system were compatible with the design.

  • PDF