• Title/Summary/Keyword: Image System

Search Result 13,347, Processing Time 0.043 seconds

A Comparison of System Performances Between Rectangular and Polar Exponential Grid Imaging System (POLAR EXPONENTIAL GRID와 장방형격자 영상시스템의 영상분해도 및 영상처리능력 비교)

  • Jae Kwon Eem
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.31B no.2
    • /
    • pp.69-79
    • /
    • 1994
  • The conventional machine vision system which has uniform rectangular grid requires tremendous amount of computation for processing and analysing an image especially in 2-D image transfermations such as scaling, rotation and 3-D reconvery problem typical in robot application environment. In this study, the imaging system with nonuiformly distributed image sensors simulating human visual system, referred to as Ploar Exponential Grid(PEG), is compared with the existing conventional uniform rectangular grid system in terms of image resolution and computational complexity. By mimicking the geometric structure of the PEG sensor cell, we obtained PEG-like images using computer simulation. With the images obtained from the simulation, image resolution of the two systems are compared and some basic image processing tasks such as image scaling and rotation are implemented based on the PEG sensor system to examine its performance. Furthermore Fourier transform of PEG image is described and implemented in image analysis point of view. Also, the range and heading-angle measurement errors usually encountered in 3-D coordinates recovery with stereo camera system are claculated based on the PEG sensor system and compared with those obtained from the uniform rectangular grid system. In fact, the PEC imaging system not only reduces the computational requirements but also has scale and rotational invariance property in Fourier spectrum. Hence the PEG system has more suitable image coordinate system for image scaling, rotation, and image recognition problem. The range and heading-angle measurement errors with PEG system are less than those of uniform rectangular rectangular grid system in practical measurement range.

  • PDF

DEVELOPMENT OF ROI PROCESSING SYSTEM USING QUICK LOOK IMAGE

  • Ahn, Sang-Il;Kim, Tae-Hoon;Kim, Tae-Young;Koo, In-Hoi
    • Proceedings of the KSRS Conference
    • /
    • 2007.10a
    • /
    • pp.526-529
    • /
    • 2007
  • Due to its inherent feature of high-resolution satellite, there is strong need in some specific area to minimize the processing time required to get a standard image on hand from downlink signal acquisition. However, in general image processing system, it takes considerable time to get image data up to certain level from raw data acquisition because the huge amount of data is dealt sequentially as input data. This paper introduces the high-speed image processing system which generates the image data only for the area selected by user. To achieve the high speed performance, this system includes Quick Look Image display function with sampling, ROI selection function, Image Line Index function, and Distributed processing function. The developed RPS was applied to KOMPSAT-2 320Mbps downlink channel and its effectiveness was successfully demonstrated. This feature to provide the image product very quickly is expected to promote the application of high resolution satellite image.

  • PDF

An X-ray Image Panorama System Using Robust Feature Matching and Per ception-Based Image Enhancement

  • Wang, Weiwei;Gwun, Oubong
    • Journal of Korea Multimedia Society
    • /
    • v.15 no.5
    • /
    • pp.569-576
    • /
    • 2012
  • This paper presents an x-ray medical image panorama system which can overcome the smallness of the images that exist on a source computer during remote medical processing. In the system, after the standard medical image format DICOM is converted to the PC standard image format, a MSR algorithm is used to enhance X-ray images of low quality. Then SURF and Multi-band blending are applied to generate a panoramic image. Also, this paper evaluates the proposed SURF based system through the average gray value error and image quality criterion with X-ray image data by comparing with a SIFT based system. The results show that the proposed system is superior to SIFT based system in image quality.

Development of 32-Channel Image Acquisition System for Thickness Measurement of Retina (망막 두께 측정을 위한 32채널 영상획득장치 개발)

  • 양근호;유병국
    • Proceedings of the Korea Institute of Convergence Signal Processing
    • /
    • 2003.06a
    • /
    • pp.110-113
    • /
    • 2003
  • In this paper, the multi-channel high speed data acquisition system is implemented. This high speed signal processing system for 3-D image display is applicable to the manipulation of a medical image processing, multimedia data and various fields of digital image processing. In order to convert the analog signal into digital one, A/D conversion circuit is designed. PCI interface method is designed and implemented, which is capable of transmission a large amount of data to computer. In order to, especially, channel extendibility of images acquisition, bus communication method is selected. By using this bus method, we can interface each module effectively. In this paper, 32-channel A/D conversion and PCI interface system for 3-dimensional and real-time display of the retina image is developed. The 32-channel image acquisition system and high speed data transmission system developed in this paper is applicable to not only medical image processing as 3-D representation of retina image but also various fields of industrial image processing in which the multi-point realtime image acquisition system is needed.

  • PDF

Implementation of an Image Board Remote Control System using PDA based on Embedded Linux in Wireless Internet (무선 인터넷 망에서 임베디드 리눅스 기반 PDA를 이용한 영상보드 원격 제어 시스템 구현)

  • Kim, Sung-Yong;Lee, Sang-Min
    • The Journal of Information Systems
    • /
    • v.17 no.1
    • /
    • pp.155-171
    • /
    • 2008
  • This thesis proposed a method that connecting step motor to image send board which can acquire image to move and remote controlling via streaming image board of PDA(personal digital assistant) based on embedded Linux which is using wireless network There are three embedded Linux system to embody movable image send board. First, though the wireless network a signal of PDA is transmitted to the board which has embedded Linux and a system which is controlled by the expansion I/O port of the board. Second, it's a system streaming realtime image at a PDA which has embedded Linux. The last is a system which controls a process of image board using TCP/IP communication and image send board at PC. These are the system which can use industrial settings and homes. It can also make use of an embodiment method about travelling image robot.

A Study on the Implementation of Multimedia Remote Ultrasound Image Transfer System through ISDN (ISDN(Integrated Services Digital Network)을 통한 멀티미디어 원격 초음파 영상 전달 시스템 구현에 관한 연구)

  • 이영훈;민경선
    • Journal of Biomedical Engineering Research
    • /
    • v.17 no.1
    • /
    • pp.33-42
    • /
    • 1996
  • A multimedia remote ultrasound image transfer system for tole-medical services was implemented. The image data of the ultrasound scanner system of the slave is compressed using image compression system. It is transferred to the master PC via ISDN UNI(User-Network Interface) and decompressd by image decompression system. The total system is composed of three parts; first, the image capture card which transfers bidirection- al data between ultrasound scanner system and PC, second, image compression and decompression card, finally, ISDN TA(Terminal Adaptor) card for transferring the image. This system has a easy user interface because it is executed on the basis of MS-WINDOWS. So it is capable of serving medical services at a remote place.

  • PDF

An Expert System for Content-based Image Retrieval with Object Database (객체 데이터베이스를 이용한 내용기반 이미지 검색 전문가 시스템)

  • Kim, Young-Min;Kim, Seong-In
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.14 no.5
    • /
    • pp.473-482
    • /
    • 2008
  • In this paper we propose an expert system for content-based image retrieval with object database. The proposed system finds keyword by using knowledge-base and feature of extracted object, and retrieves image by using keyword based image retrieval method. The system can decrease error of image retrieval and save running time. The system also checks whether similar objects exist or not. If not, user can store information of object in object database. Proposed system is flexible and extensible, enabling experts to incrementally add more knowledge and information. Experimental results show that the proposed system is more effective than existing content-based image retrieval method in running time and precision.

Realization of a Parallel Network System for Image Processing Techniques (영상 처리 기법을 위한 병렬화 네트워크 시스템의 구성)

  • 서원찬;조강현;김우열
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.6 no.6
    • /
    • pp.492-499
    • /
    • 2000
  • In this paper, realization techniques of the parallel processing and the parallel network system for image processing are described. The parallel image processing system is constructed by the characterization of image processing and processor. Several problems are solved to achieve effective parallel processing and processor networking with the particular properties of image processing, which are reduction of communication quantity, equalization of load and delay depreciation on communication. A parallel image input device is developed for the flexible networking of parallel image processing. An abnormal region detection algorithm which is the basic function in machine vision is applied to evaluate the constructed parallel image processing system. The performance and effectiveness of the system are confirmed by experiments.

  • PDF

Developing Management System of Medical Image Information with USB 2.0 (USB 2.0을 활용한 의료 영상정보 관리시스템 개발)

  • Choi, Jung-Sang
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.29 no.2
    • /
    • pp.51-57
    • /
    • 2006
  • This study is concerned with image information management system for small scale hospital. We intended to developing image management system which is used of the existing analog devices such as medical camera, supersonic analyser, endoscope etc. We developed a video in interface board based USB 2.0 for handling image in real time. It is capable of transmitting image input signal like as NTSC, PAL to personal computer through USB 2.0. The developed the board of 40 speeds compared with the exiting system based USB 1.0. Especially the developed system is very helpful for small hospital like as dental clinic, because it is easy and convenient to manage image information without expert. So it will provide reduction of time and cost for handling image information(collecting, saving, retrieval, transmitting image).

Development of Basic Application Software for KOMPSAT High Resolution Images

  • Park S. Y.;Lee K. J.;Kim Y. S.
    • Proceedings of the KSRS Conference
    • /
    • 2004.10a
    • /
    • pp.509-511
    • /
    • 2004
  • This paper outlines the development of image processing system, which will allow the general users in Government and Public organizations easily to use and apply KOMPSAT EOC images in their own business. The system includes an import/export module of EOC image distributed in Hierarchical Data Format (HDF) file and various image processing analysis modules. Especially, the image mosaic and subset functions are designed to use EOC image as an image map, generating the Ortho-image module. To update the various spatial data with EOC image, some essential modules such as change detection by pattern recognition, overlay between images and vector data, and modification of vector data are implemented in the system. The system is developed based on the user request analysis of government agency, and suited for more efficient use of satellite image in public applications. Such system is expected to contribute to practical application of KOMPSAT-2 that will be launched in 2005. Further efforts will be made to accommodate the KOMPSAT -2 MSC data.

  • PDF