• Title/Summary/Keyword: Image Simulation

Search Result 2,746, Processing Time 0.03 seconds

IMAGE SIMULATIONS FOR THE KVN USING THE VLBA IMAGE OF SiO MASERS (SiO MASERS의 VLBA 이미지를 이용한 KVN 이미지 모의실험)

  • Yi, Ji-Yune;Jung, Tae-Hyun
    • Publications of The Korean Astronomical Society
    • /
    • v.23 no.2
    • /
    • pp.37-45
    • /
    • 2008
  • We present the results of image simulations of 43.1 GHz SiO maser emission toward a Mira variable using the KVN (Korean VLBI Network) and other facilities which can make joint VLBI experiments with the KVN. To test the imaging capability of the KVN we used the image of SiO masers in the simulation obtained by the VLBA, which is considered to be the optimum VLBI facility at present to study SiO masers toward evolved stars. The simulated images of SiO maser emission confirm that coordinate VLBI expriments of KVN with several more stations in Japan or in the neighborhood of Korean Peninsula are necessary to exert the functional benefit of the KVN as the first mm VLBI facility which can perform simultaneous observations at four different frequency bands.

Single Image-Based 3D Tree and Growth Models Reconstruction

  • Kim, Jaehwan;Jeong, Il-Kwon
    • ETRI Journal
    • /
    • v.36 no.3
    • /
    • pp.450-459
    • /
    • 2014
  • In this paper, we present a new, easy-to-generate system that is capable of creating virtual 3D tree models and simulating a variety of growth processes of a tree from a single, real tree image. We not only construct various tree models with the same trunk through our proposed digital image matting method and skeleton-based abstraction of branches, but we also animate the visual growth of the constructed 3D tree model through usage of the branch age information combined with a scaling factor. To control the simulation of a tree growth process, we consider tree-growing attributes, such as branching orders, branch width, tree size, and branch self-bending effect, at the same time. Other invisible branches and leaves are automatically attached to the tree by employing parametric branch libraries under the conventional procedural assumption of structure having a local self-similarity. Simulations with a real image confirm that our system makes it possible to achieve realistic tree models and growth processes with ease.

An Image Improvement for Microwave Diffraction Tomography under the Born Approximation Based on the Projection Function (Born 근사하에 투영함수를 이용한 초고주파 회절단층촬영의 영상개선)

  • 서경환;김상기;라정웅;김세윤
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.29A no.2
    • /
    • pp.1-7
    • /
    • 1992
  • A consideration for image improvement under the Born approximation in the microwave diffraction tomography is suggested by using a projection function. The limiting factors in the degrading reconstructed image due to Born approximation are identified in terms of projection function and its modification is suggested to improve the degraded image based upon the Born approximation. In order to verify the proposed method, the reconstructed images are shown by computer simulation from the back-scattered data of angular and frequency diversity for squared dielectric cylinder with a various relative dielectric constant. From simulation results, it was shown that the proposed method can lead to a fairly good improved image for a severe degraded one irrespective of homogeneous and inhomogeneous dielectric object. In the future, the analysis on the limitation of this method should be considered and performed by means of more quantitative method.

  • PDF

Validity of LIGHTSCAPE As a Visualization Tool for Daylighting Performance (자연채광 성능의 가시화도구로서 LIGHTSCAPE의 유용성 평가)

  • 문기훈;김정태
    • Korean Institute of Interior Design Journal
    • /
    • no.37
    • /
    • pp.110-118
    • /
    • 2003
  • Computer simulation is one of the most useful techniques to predict daylighting performance and present visual image. In architectural and interior design practice, the Lightscape is commonly used often to produce persuasive images rather than physically accurate results. Therefore, this study is to validity the Lightscape as daylighting evaluation tool, in particularly performance and realistically visualization. For the purpose, an evaluation test model (12.0m$\times$7.2m$\times$3.0m) of side lighting window with lightshelf was selected. A 1:6 scale plywood physical model was made. Under clear sky condition, illuminance of 84 Interior point were measured. Lightscape was run on a 750 MHz Pentium PC running Windows 2000 under the same sky condition. And a photography image was compared to rendering image. The physical results of interior illuminance were within 8% between the scale model and Lightscape simulation. There were no differences between the photograph image and rendering image by Lightscape in the sight. Lightscape as visualization tool for daylighting performance was validated.

Comparison Evaluation of Image Quality with Different Thickness of Aluminum added Filter using GATE Simulation in Digital Radiography (GATE 시뮬레이션을 사용한 알루미늄 부가필터 두께에 따른 Digital Radiography의 영상 화질 비교 평가)

  • Oh, Minju;Hong, Joo-Wan;Lee, Youngjin
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.1
    • /
    • pp.81-86
    • /
    • 2019
  • In X-ray image, the role of filtration through the filter is to reduce the exposure of the patient by using photon which is useful in formation of the image, and at the same time, enhance the contrast of the image. During interaction between photon and object, low energy X-rays are absorbed from the site of a few cm of the first patient's tissue, and high energy X-rays are the one which form the image. Therefore, the radiation filter absorbs low energy X-ray in order to lower the exposure of the patient and improve the quality of the image. The purpose of this study is to compare the effect on the image quality by differences of added filter through simulation image and actual radiation image. For that purpose, we used Geant4 Application for Tomographic Emission (GATE) as a tool for Monte Carlo simulation. We set actual size, shape and material of Polymethylmethacrylate (PMMA) Phantom on GATE and differentiated the parameter of added filter. Also, we took image of PMMA phantom with same parameter of added filter by digital radiography (DR). Than we performed contrast-to-noise ratio (CNR) evaluation on both simulation image and actual DR image by Image J. Finally, we observed the effect on image quality due to different thickness of added filter, and compared two images' CNR evaluation's transitions of change. The result of this experiment showed decreasing in the progress of CNR on both DR and simulation image. It is ultimately caused by decreasing in contrast on image. In theory, contrast decrease with kVp increased. Given that condition, this study found out that filter makes not only decreasing total dose by absorbing low energy of X-ray, but also increasing average energy of X-ray.

The Analysis of Resolution on the Image Reconstnlction Algorithms for Ultrasonic Diffraction Tomography (초음파 회절 토모그라피 영상복원 알고리즘의 분해능 분석)

  • 구길모;황기환
    • The Journal of the Acoustical Society of Korea
    • /
    • v.18 no.5
    • /
    • pp.83-90
    • /
    • 1999
  • In this paper, we studied resolution to the FBP and BFP image reconstruction algorithms for ultrasonic diffraction tomography. In order to analyze the resolution to the tomographic images which can be reconstructed from the modified FBP image reconstruction algorithm by using fixed coordinate system and BFP image reconstruction algorithm which is suitable for plane structure object, we derived ambiguity functions to these algorithms and then analyzed lateral and depth resolution through simulation respectively. Simulation results show that the lateral and depth resolution to the FBP image reconstruction algorithm and the BFP image reconstruction algorithm was determined 0.27 λ, 0.70 λ and 0.39 λ, 0.98 λ at the 3dB respectively. These results imply that modified FBP and BFP image reconstruction algorithms for diffraction tomography is useful in the tomographic image reconstruction.

  • PDF

Synthetic Infra-Red Image Dataset Generation by CycleGAN based on SSIM Loss Function (SSIM 목적 함수와 CycleGAN을 이용한 적외선 이미지 데이터셋 생성 기법 연구)

  • Lee, Sky;Leeghim, Henzeh
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.25 no.5
    • /
    • pp.476-486
    • /
    • 2022
  • Synthetic dynamic infrared image generation from the given virtual environment is being the primary goal to simulate the output of the infra-red(IR) camera installed on a vehicle to evaluate the control algorithm for various search & reconnaissance missions. Due to the difficulty to obtain actual IR data in complex environments, Artificial intelligence(AI) has been used recently in the field of image data generation. In this paper, CycleGAN technique is applied to obtain a more realistic synthetic IR image. We added the Structural Similarity Index Measure(SSIM) loss function to the L1 loss function to generate a more realistic synthetic IR image when the CycleGAN image is generated. From the simulation, it is applicable to the guided-missile flight simulation tests by using the synthetic infrared image generated by the proposed technique.

A cosmic ray muons tomography system with triangular bar plastic scintillator detectors and improved 3D image reconstruction algorithm: A simulation study

  • Yanwei Zhao;Xujia Luo;Kemian Qin;Guorui Liu;Daiyuan Chen;R.S. Augusto;Weixiong Zhang;Xiaogang Luo;Chunxian Liu;Juntao Liu;Zhiyi Liu
    • Nuclear Engineering and Technology
    • /
    • v.55 no.2
    • /
    • pp.681-689
    • /
    • 2023
  • Purpose: Muons are characterized by a strong penetrating ability and can travel through thousands of meters of rock, making them ideal to image large volumes and substances typically impenetrable to, for example, electrons and photons. The feasibility of 3D image reconstruction and material identification based on a cosmic ray muons tomography (MT) system with triangular bar plastic scintillator detectors has been verified in this paper. Our prototype shows potential application value and the authors wish to apply this prototype system to 3D imaging. In addition, an MT experiment with the same detector system is also in progress. Methods: A simulation based on GEANT4 was developed to study cosmic ray muons' physical processes and motion trails. The yield and transportation of optical photons scintillated in each triangular bar of the detector system were reproduced. An image reconstruction algorithm and correction method based on muon scattering, which differs from the conventional PoCA algorithm, has been developed based on simulation data and verified by experimental data. Results: According to the simulation result, the detector system's position resolution is below 1 ~ mm in simulation and 2 mm in the experiment. A relatively legible 3D image of lead bricks in size of 20 cm × 5 cm × 10 cm used our inversion algorithm can be presented below 1× 104 effective events, which takes 16 h of acquisition time experimentally. Conclusion: The proposed method is a potential candidate to monitor the cosmic ray MT accurately. Monte Carlo simulations have been performed to discuss the application of the detector and the simulation results have indicated that the detector can be used in cosmic ray MT. The cosmic ray MT experiment is currently underway. Furthermore, the proposal also has the potential to scan the earth, buildings, and other structures of interest including for instance computerized imaging in an archaeological framework.

Three-dimensional Reconstruction of the Knee for Ligament Reconstruction

  • Kim, Sung-Hwan;Ha, Seung-Joo
    • Journal of International Society for Simulation Surgery
    • /
    • v.1 no.1
    • /
    • pp.19-22
    • /
    • 2014
  • As computer technology develops and this is applied to medical image field, three dimensional image reconstruction technology using computer simulation is utilized in various categories that include anatomical study and biomechanics study of human body. Especially orthopedic surgeons are able to investigate biomechanical function and be provided information for operations with this technology in terms of ligament reconstruction of knee. And this technology can be utilized in preparing preoperative planning and instructions and training. This review is about three dimensional image reconstruction technology which is utilized in ligament reconstruction of knee.

Reference Functions for Synthesis and Analysis of Multiview and Integral Images

  • Saveljev, Vladimir;Kim, Sung-Kyu
    • Journal of the Optical Society of Korea
    • /
    • v.17 no.2
    • /
    • pp.148-161
    • /
    • 2013
  • We propose one- and two-dimensional reference functions for processing of integral/multiview imaging. The functions provide the synthesis/analysis of the integral image by distance, as an alternative to the composition/decomposition by view images (directions). The synthesized image was observed experimentally. In analysis confirmed by simulation in a qualitative sense, the distance was obtained by convolution of the integral image with the reference functions.