Reduction of Radiation Exposure by Modifying Imaging Manner and Fluoroscopic Settings during Percutaneous Pedicle Screw Insertion

  • Kim, Hyun Jun;Park, Eun Soo;Lee, Sang Ho;Park, Chan Hong;Chung, Seok Won
    • Journal of Korean Neurosurgical Society
    • /
    • 제64권6호
    • /
    • pp.933-943
    • /
    • 2021
  • Objective : Percutaneous pedicle screw (PPS) fixation is a needle based procedure that requires fluoroscopic image guidance. Consequently, radiation exposure is inevitable for patients, surgeons, and operation room staff. We hypothesize that reducing the production of radiation emission will result in reduced radiation exposure for everyone in the operation room. Research was performed to evaluate reduction of radiation exposure by modifying imaging manner and mode of radiation source. Methods : A total of 170 patients (680 screws) who underwent fusion surgery with PPS fixation from September 2019 to March 2020 were analyzed in this study. Personal dosimeters (Polimaster Ltd.) were worn at the collar outside a lead apron to measure radiation exposure. Patients were assigned to four groups based on imaging manner of fluoroscopy and radiation modification (pulse mode with reduced dose) : continuous use without radiation modification (group 1, n=34), intermittent use without radiation modification (group 2, n=54), continuous use with radiation modification (group 3, n=26), and intermittent use with radiation modification (group 4, n=56). Post hoc Tukey Honest significant difference test was used for individual comparisons of radiation exposure/screw and fluoroscopic time/screw. Results : The average radiation exposure/screw was 71.45±45.75 µSv/screw for group 1, 18.77±11.51 µSv/screw for group 2, 19.58±7.00 µSv/screw for group 3, and 4.26±2.89 µSv/screw for group 4. By changing imaging manner from continuous multiple shot to intermittent single shot, 73.7% radiation reduction was achieved in the no radiation modification groups (groups 1, 2), and 78.2% radiation reduction was achieved in the radiation modification groups (groups 3, 4). Radiation source modification from continuous mode with standard dose to pulse mode with reduced dose resulted in 72.6% radiation reduction in continuous imaging groups (groups 1, 3) and 77.3% radiation reduction in intermittent imaging groups (groups 2, 4). The average radiation exposure/screw was reduced 94.1% by changing imaging manner and modifying radiation source from continuous imaging with standard fluoroscopy setting (group 1) to intermittent imaging with modified fluoroscopy setting (group 4). A total of 680 screws were reviewed postoperatively, and 99.3% (675) were evaluated as pedicle breach grade 0 (<2 mm). Conclusion : The average radiation exposure/screw for a spinal surgeon can be reduced 94.1% by changing imaging manner and modifying radiation source from real-time imaging with standard dose to intermittent imaging with modified dose. These modifications can be instantly applied to any procedure using fluoroscopic guidance and may reduce the overall radiation exposure of spine surgeons.

RNCC 기반 다시기 RapidEye 위성영상의 정밀 상호좌표등록 (RNCC-based Fine Co-registration of Multi-temporal RapidEye Satellite Imagery)

  • 한유경;오재홍
    • 한국측량학회지
    • /
    • 제36권6호
    • /
    • pp.581-588
    • /
    • 2018
  • 본 연구는 다시기 영상의 활용이 유리한 RapidEye 영상의 활용성을 증대시키기 위하여, 이들 간에 지역적으로 존재하는 기하오차를 최소화 하는 정밀 상호좌표등록 기법을 제안하였다. 이를 위해, RapidEye 영상과 함께 제공되는 RPCs (Rational Polynomial Coefficients)를 이용하여 다시기 정사영상을 생성하고, 정사영상 간의 정밀 상호 좌표등록을 수행하였다. 정사영상을 생성하기 위해서 수치지도에서 추출된 DEM (Digital Elevation Model)을 활용하였으며, 정밀 상호좌표등록을 수행하기 위하여 RNCC (Registration Noise Cross Correlation) 기법을 적용하였다. 영광지역에 대해 2015년 5월부터 2016년 11월까지 획득된 RapidEye 1B 영상 총 4장을 활용하여 실험을 진행하였으며, 밴드별(blue, green, red, red edge, near-infrared)로 적용된 정밀 상호좌표등록 결과 비교분석을 통해 각 밴드가 보이는 상호좌표등록 적용 가능성 여부를 판단하였다. 실험 결과, RapidEye 영상의 모든 밴드를 활용하여 상호좌표등록이 가능하였으며, 상호좌표등록을 하지 않았을 때보다 다시기 영상 간 정량적/정성적으로 향상된 기하 일치도를 보였다. 특히 red와 red edge 밴드를 이용할 경우 다시기 영상 촬영시기의 계절적 차이에 관계없이 안정적인 상호좌표등록 결과를 보임을 확인하였다.

RGB 이미지를 이용한 관절 추정 네트워크와 결합된 FBX 형식 애니메이션 생성 시스템 (FBX Format Animation Generation System Combined with Joint Estimation Network using RGB Images)

  • 이유진;김상준;박구만
    • 방송공학회논문지
    • /
    • 제26권5호
    • /
    • pp.519-532
    • /
    • 2021
  • 최근 게임, 영화, 애니메이션 다양한 분야에서 모션 캡처를 이용하여 신체 모델을 구축하고 캐릭터를 생성하여 3차원 공간에 표출하는 콘텐츠가 증가하고 있다. 마커를 부착하여 관절의 위치를 측정하는 방법에서 촬영 장비에 대한 비용과 같은 문제를 보완하기 위해 RGB-D 카메라를 이용하여 애니메이션을 생성하는 연구가 진행되고 있지만, 관절 추정 정확도나 장비 비용의 문제가 여전히 존재한다. 이에 본 논문에서는 애니메이션 생성에 필요한 장비 비용을 줄이고 관절 추정 정확도를 높이기 위해 RGB 이미지를 관절 추정 네트워크에 입력하고, 그 결과를 3차원 데이터로 변환하여 FBX 형식 애니메이션으로 생성하는 시스템을 제안한다. 먼저 RGB 이미지에 대한 2차원 관절을 추정하고, 이 값을 이용하여 관절의 3차원 좌표를 추정한다. 그 결과를 쿼터니언으로 변환하여 회전한 후, FBX 형식의 애니메이션을 생성한다. 제안한 방법의 정확도 측정을 위해 신체에 마커를 부착하여 마커의 3차원 위치를 바탕으로 생성한 애니메이션과 제안된 시스템으로 생성한 애니메이션의 오차를 비교하여 시스템 동작을 입증하였다.

3D Printing 기술을 활용한 Digital Craft 융합적 사례 연구 (A Study on the Digital Craft Convergence Cases Using 3D Printing Technology)

  • 장지수;정진헌
    • 한국인터넷방송통신학회논문지
    • /
    • 제22권3호
    • /
    • pp.105-110
    • /
    • 2022
  • 4차 산업혁명이라는 흐름에 따라 서로 다른 분야의 결합을 통해 새로운 분야가 생기는 융복합의 시기를 맞아 예술 분야 중 크래프트 영역의 확장성에 관해 연구하고자 하였다. 연구 내용은 디지털 크래프트의 정의와 가치에 대한 이론적 배경을 토대로 3D 프린팅 기술을 활용한 크래프트 사례를 분석한 것이다. 연구 결과, 3D 프린팅 기술을 활용한 크래프트 작품은 융합적 표현 방식에 따라 크게 네 가지의 형태로 나누어 볼 수 있었다. 첫 번째로 혼합형은 전통 크래프트 형식에서 크게 벗어나지 않으면서도 조화롭게 제작된 것이 가장 큰 특징이었다. 두 번째로 부품형은 일정한 형태와 세밀한 작업이 장점인 디지털 기술의 특징이 가장 잘 나타난 형태로 제작되었다. 세 번째로 구조형은 3D 프린터로 출력한 결과물을 베이스로 하여 전통 크래프트 기법이 덧입혀져 아날로그 감성이 묻어나는 작품이 되었다. 네 번째로 연결형은 본 연구의 분석 사례 중에서 독창성과 고유성이 가장 크게 엿보인 작품이었다. 디지털 기술이 널리 활용되고 있는 만큼, 효과적인 작업 방향성에 관하여 지속적인 연구가 필요하다고 판단된다.

도시 공공공간 조명디자인 유형과 장소성에 관한 연구 (A Study on the Type and Sense of Place of the Lighting Design of Urban Public Space)

  • 마동칭;윤지영
    • 한국과학예술포럼
    • /
    • 제27권
    • /
    • pp.101-114
    • /
    • 2017
  • 본 논문은 도시 공공공간, 조명 디자인과 장소성과의 관련성에 의거하여, 도시 디자인에서 장소성을 표현하는 도시 조명디자인의 유형을 분류하고 유형별 특성을 파악하는데 그 목적이 있다. 우선 선행 연구고찰을 토대로, 공공공간의 조명디자인의 장소성 평가를 위한 6개 디자인 평가요소를 추출하였고, 12개의 우수 조명 디자인 사례에 대해 분석하였다. 연구결과 12개 사례에 대해 기본형, 은유플롯형, 인터랙티브형, 미디어 복합형 등의 4개 유형으로 공공공간 조명디자인을 분류하였고 각 유형별로 주도적인 디자인 평가요소와 그 특성을 파악하였다. 연구 결과로는, 첫째, 기능성, 지속 가능성, 심미성은 도시 공공공간 조명을 통한 장소성을 실현시키는 기본적 요소라고 할 수 있다. 둘째, "은유 플롯형"에 속한 사례는 6가지이며, 이 유형의 사례는 특정 지역에 대한 테마 즉 스토리텔링의 발굴이기 때문에, 조명 디자인에서도 뚜렷하고 명확한 지역 정체성을 형성할 수 있다. 셋째, "인터랙티브형"과 "미디어복합형"은, 새로운 매개 기술 및 최첨단의 조명 방식이 개입되었기 때문에, 도시 조명디자인의 의미와 외연이 광범위하게 확장되었다고 할 수 있다. 연구 결과를 통하여 도시 공공공간의 조명디자인의 유형과 특성을 파악하여 장소성을 강화하고 도시 이미지를 향상시킬 수 있는 도시 공공공간의 조명디자인 개발을 위한 기초자료를 제공하고자 한다.

No-Touch Radiofrequency Ablation Using Twin Cooled Wet Electrodes for Recurrent Hepatocellular Carcinoma Following Locoregional Treatments

  • Seong Jun Hong;Jae Hyun Kim;Jeong Hee Yoon;Jeong Hoan Park;Jung-Hwan Yoon;Yoon Jun Kim;Su Jong Yu;Eun Ju Cho;Jeong Min Lee
    • Korean Journal of Radiology
    • /
    • 제25권5호
    • /
    • pp.438-448
    • /
    • 2024
  • Objective: To evaluate the therapeutic outcomes of no-touch radiofrequency ablation (NT-RFA) using twin cooled wet (TCW) electrodes in patients experiencing recurrent hepatocellular carcinoma (HCC) after undergoing locoregional treatments. Materials and Methods: We conducted a prospective, single-arm study of NT-RFA involving 102 patients, with a total of 112 recurrent HCCs (each ≤ 3 cm). NT-RFA with TCW electrodes was implemented under the guidance of ultrasonography (US)-MR/CT fusion imaging. If NT-RFA application proved technically challenging, conversion to conventional tumor puncture RFA was permitted. The primary metric for evaluation was the mid-term cumulative incidence of local tumor progression (LTP) observed post-RFA. Cumulative LTP rates were estimated using the Kaplan-Meier method. Multivariable Cox proportional hazard regression was used to explore factors associated with LTP. Considering conversion cases from NT-RFA to conventional RFA, intention-to-treat (ITT; including all patients) and per-protocol (PP; including patients not requiring conversion to conventional RFA alone) analyses were performed. Results: Conversion from NT-RFA to conventional RFA was necessary for 24 (21.4%) out of 112 tumors. Successful treatment was noted in 111 (99.1%) out of them. No major complications were reported among the patients. According to ITT analysis, the estimated cumulative incidences of LTP were 1.9%, 6.0%, and 6.0% at 1, 2, and 3 years post-RFA, respectively. In PP analysis, the cumulative incidence of LTP was 0.0%, 1.3%, and 1.3% at 1, 2, and 3 years, respectively. The number of previous locoregional HCC treatments (adjusted hazard ratio [aHR], 1.265 per 1 treatment increase; P = 0.004), total bilirubin (aHR, 7.477 per 1 mg/dL increase; P = 0.012), and safety margin ≤ 5 mm (aHR, 9.029; P = 0.016) were independently associated with LTP in ITT analysis. Conclusion: NT-RFA using TCW electrodes is a safe and effective treatment for recurrent HCC, with 6.0% (ITT analysis) and 1.3% (PP analysis) cumulative incidence of LTP at 2 and 3-year follow-ups.

인조 번호판을 이용한 자동차 번호인식 성능 향상 기법 (Improved Method of License Plate Detection and Recognition using Synthetic Number Plate)

  • 장일식;박구만
    • 방송공학회논문지
    • /
    • 제26권4호
    • /
    • pp.453-462
    • /
    • 2021
  • 자동차 번호인식을 위해선 수많은 번호판 데이터가 필요하다. 번호판 데이터는 과거의 번호판부터 최신의 번호판까지 균형 있는 데이터의 확보가 필요하다. 하지만 실제 과거의 번호판부터 최신의 번호판의 데이터를 획득하는데 어려움이 있다. 이러한 문제를 해결하기 위해 인조 번호판을 이용하여 자동차 번호판을 생성하여 딥러닝을 통한 번호판 인식 연구가 진행되고 있다. 하지만 인조 데이터는 실제 데이터와 차이가 존재하며, 이러한 문제를 해결하기 위해 다양한 데이터 증강 기법을 사용한다. 기존 데이터 증강 방식은 단순히 밝기, 회전, 어파인 변환, 블러, 노이즈등의 방법을 사용하였다. 본 논문에서는 데이터 증강 방법으로 인조데이터를 실제 데이터 스타일로 변환하는 스타일 변환 방법을 적용한다. 또한 실제 번호판 데이터는 원거리가 많고 어두운 경우 잡음이 많이 존재한다. 단순히 입력데이터를 가지고 문자를 인식할 경우 오인식의 가능성이 높다. 이러한 경우 문자인식 향상을 위해 본 논문에서는 문자인식을 위하여 화질개선 방법으로 DeblurGANv2 방법을 적용하여 번호판 인식 정확도를 높였다. 번호판 검출 및 번호판 번호인식을 위한 딥러닝의 방식은 YOLO-V5를 사용하였다. 인조 번호판 데이터 성능을 판단하기 위해 자체적으로 확보한 자동차 번호판을 수집하여 테스트 셋을 구성하였다. 스타일 변환을 적용하지 않은 번호판 검출이 0.614mAP를 기록하였다. 스타일 변환을 적용한 결과 번호판 검출 성능이 0.679mAP 기록하여 성능이 향상되었음을 확인하였다. 또한 번호판 문자인식에는 화질 개선을 하지 않은 검출 성공률은 0.872를 기록하였으며, 화질 개선 후 검출 성능이 0.915를 기록하여 성능 향상이 되었음을 확인 하였다.

고군산 선유팔경(仙遊八景)의 설정과정과 집경(集景) 특성 (A Study on the Setting Process and Formational Characteristics of the Seonyu Eight Scenic in Gogunsan Islands)

  • 정우진;황국웅
    • 한국전통조경학회지
    • /
    • 제37권4호
    • /
    • pp.32-50
    • /
    • 2019
  • 본 연구는 고군산 선유팔경이 설정된 경위와 각 경점의 경관특성을 고찰한 것으로 요약된 결론은 다음과 같다. 첫째, 1969년 이래 설정된 경점은 수차례 그 내용과 순서가 바뀌었고 표제어 또한 일정한 변천과정이 확인된다. 70년대까지 알려진 팔경은 공식적인 팔경명이 없거나 고군산팔경으로 명명된 경우가 많았으며, 무산십이봉이 제외된 구성을 보인다. 또한 팔경의 경점이 시기별로 제각각인 유형도 나타나는데, 따라서 선유팔경의 초기 형태는 인근 지역의 팔경을 참조하되, 고군산군도 특히 선유도의 경승이 취사선택된 것이었음을 알 수 있다. 둘째, 현재와 같은 팔경 요소가 모두 충족되어 나타나는 2000년대 초의 선유팔경은 순번이 명시되어 있고 표제어가 네 글자로 정제되어 있어 전통적인 팔경의 명명법을 따르고 있다. 이때 제1경이 망주폭포로 설정되고 선유낙조가 제8경으로 구분되기도 하였는데, 현재는 제1경이 선유낙조, 제2경이 망주폭포의 순서로 확정되었다. 이러한 경처 순서의 변화는 시기별 대표 경관자원이 달랐다는 점을 잘 보여준다. 셋째, 정체성과 완결성이 약한 점은 선유팔경에 내재된 문제점으로 지적된다. 무엇보다 설정주체와 설정시기가 모호하며, 선행되는 옥구팔경, 임피팔경 등 인근 지역의 팔경사례를 답습한 흔적이 역력하다. 또한 경관대상에 대한 지식정보, 조망하는 시점의 명시, 역사·문화적 배경 등이 모호하여 정제되지 않은 불완전한 체계를 갖는 것으로 평가된다. 넷째, 제1경 선유낙조는 전체 경점을 대표하는 것을 넘어 팔경 전체를 지배하는 주도적인 이미지를 갖는다. 일시적 경관인 낙조가 제일의 경관이 될 수 있었던 것은 그것이 선유도의 아름다운 자연적 요소들이 융합하여 만들어진 경관의 총체로 인식되었기 때문이었다. 따라서 선유낙조를 기점으로 선유도 및 고군산군도 전체 경관을 탐색해 보고자 하는 기왕의 인식을 활용하여, 다른 고군산군도 경관자원의 가치 고양시킬 여지는 충분하다고 판단되며, 이를 위해서 각 경점의 정체성과 완결성을 강화하는 작업이 추가되어야 할 것으로 사료된다.

외부 반출 PET/CT 영상 현황 및 개선점 (Current Status and Improvements of Transfered PET/CT Data from Other Hospitals)

  • 김계환;최현준;이홍재;김진의;김현주
    • 핵의학기술
    • /
    • 제14권2호
    • /
    • pp.38-40
    • /
    • 2010
  • 이 논문은 먼저 서울대병원 PET/CT 외부 반입 영상 자료의 현황을 파악하고 이를 바탕으로 현재 각 병원 간 전송을 위해 사용되는 PET/CT 영상 자료의 현황과 문제점에 대해 알아보고자 한다. 2010년 1월부터 4월까지 외부 병원에서 의뢰한 PET/CT 영상 판독 의뢰가 있었던 64개 병원을 대상으로 하였다. 각 병원들의 PET/CT 영상 자료에 대해 개별 PET과 CT 영상 자료 제공 여부, PET/CT 융합 영상 제공 여부 등을 조사하였다. 그리고 외래 판독 의뢰가 많았던 병원 상위 5개 병원의 핵의학과 책임자에게 전화를 통한 설문 조사를 실시하였다. 질문 항목은 각 병원 핵의학과에서는 외부 병원 반출용 PET/CT 영상 자료의 구성에 대해 알고 있는지 여부와 핵의학과 자체에서 외부 병원 영상을 처리하는지 여부이다. 서울대병원에 판독이 의뢰된 64개 병원의 PET/CT 영상 CD 자료에 대해 조사하였다. 이 중 횡단면 PET 영상을 제공해준 병원은 조사된 전체 병원의 73%, 횡단면 CT 영상을 제공해준 병원은 조사된 전체 병원의 73%에 불과하였으며 횡단면 융합 영상을 제공해준 병원은 조사된 전체 병원의 77%, MIP 영상을 제공해준 병원은 조사된 전체 병원의 86%였다. 그리고 병원마다 보내는 데이터들이 다 제각각이었다. 어떤 경우는 DICOM 표준형식의 횡단면 PET/CT 영상 등 모든영상이 포함된 경우도 있고 반대로 MIP 영상과 2차원 캡쳐 영상이 없는 경우도 있다. 최소한의 영상을 포함시키는 것도 중요하지만 불필요하게 많은 영상 정보들은 저장 매체의 용량과 영상의 복사 등의 이동 시간에도 비효율적이다. 가장 중요한 DICOM 표준 형식의 횡단면 PET/CT 영상을 전혀 포함하지 않은 병원들을 대상으로 한 전화 설문에서는 핵의학과 자체에서 외부 반출용 PET/CT 영상 자료의 구성에 대해 모르고 있었으며 핵의학 영상 자료를 PACS에 올리고 외부 반출용 영상 CD 제작을 타 부서에서 진행하고 있었다. 현재 각 병원들에서 외부 병원으로 복사하여 보내는 PET/CT 영상 자료 CD는 전체 대상 병원의 27% 이상에서 제한적인 영상만을 포함하고 있어 외부 병원 영상을 받아 환자진료에 이용하는 병원에서는 제한된 영상 정보로 인한 PET/CT 검사의 판독 및 활용 상의 어려움, 재촬영에 따른 추가 의료비 지출이 상당한 문제가 되고 있다. 각 병원들에서 외부 병원으로 보내는 PET/CT 영상 자료에는 최소한 DICOM 표준 형식의 전체 횡단면 PET 영상과 전체 횡단면 CT 영상을 필수적으로 포함시키도록 하고 불필요한 영상을 최소화하는 학회 차원에서의 외부 반출 PET/CT 영상에 대한 가이드라인 마련이 필요하다고 사료된다.

  • PDF

의료용 방사능측정기의 측정 정확도 평가 (Comparison of Radioactivity Measurement with Radionuclide Calibrators in Nuclear Medicine Centers)

  • 손혜경;김지혜;임천일;양현규;박기정;오헌진;김혁주;김동섭
    • 한국의학물리학회지:의학물리
    • /
    • 제21권1호
    • /
    • pp.16-21
    • /
    • 2010
  • 우수한 핵의학 영상의 획득과 불필요한 환자 피폭을 최소화하기 위한 가장 중요한 요소 중 하나가 방사성의약품의 방사능을 정확하게 측정하는 것이다. 이를 위해서는 각 의료기관에서 사용하고 있는 방사능측정기에 대한 적절한 품질관리가 수행되어야 한다. 따라서 본 연구에서는 국내 의료기관이 보유하고 있는 방사능측정기의 품질관리를 지원하고 의료기관이 사용하고 있는 방사능측정기의 측정 정확도를 평가하고자 방사능비교측정을 수행하였다. 방사능비교측정은 I-131, Tc-99m, I-123을 이용하여 각각 수행하였다. I-131을 이용한 방사능 비교측정에는 45개 기관의 58개 방사능측정기가 참여하였고, Tc-99m의 경우 58개 기관의 74개 방사능측정기가 참여하였으며, I-123의 경우는 45개 기관 60개 방사능 측정기가 참여하였다. 편차가 ${\pm}10%$를 벗어나는 측정기에 대해서는 추가적인 비교측정을 수행하였으며, 그 결과 일부 측정기는 편차가 ${\pm}10%$ 이내로 개선되었다. 비교측정 결과 편차가 ${\pm}5%$ 이내인 측정기가 각각 81% (I-131), 61% (Tc-99m), 67% (I-123)이었고, 편차가 5%< $|{\Delta}|{\leq}|10%$ 이내인 측정기는 각각 17% (I-131), 20% (Tc-99m), 15% (I-123)이었으며, 편차가 ${\pm}10%$를 초과한 측정기는 각각 2% (I-131), 19% (Tc-99m), 18% (I-123)이었다. 본 연구의 결과로부터 방사능비교측정은 의료기관의 방사능 측정 정확도를 향상시키고, 방사능측정기의 측정 정확도 저하여부를 확인하기 위해 지속적으로 수행되어져야 할 것으로 생각한다.