• 제목/요약/키워드: Illumination optics

검색결과 135건 처리시간 0.023초

유치원 원아의 시력측정 (A Test of Visual Acuity to Kindergarten's Children)

  • 강현식;서용원;강인산
    • 한국안광학회지
    • /
    • 제1권1호
    • /
    • pp.53-56
    • /
    • 1996
  • 유치원 원아 109명 218안을 대상으로 시력 및 조절마비제를 사용하지 않은 상태에서 타각적 굴절이상을 측정한 결과, 만3세의 평균시력이 0.6, 만 4세의 평균시력이 0.7, 만 5세의 평균시력이 1.0으로 나타났다. 이는 일본 어린이와 비교하면 약간 떨어지지만 연령이 증가함에 따라 시력도 발달해가는 경향을 보이고 있다. 굴절이상에 있어서는 혼합난시가 14.7%, 원시 18.8%, 근시 66.5%로 나타났다.

  • PDF

Straylight analysis for preliminary filter and baffle design for New Generation GOCI

  • Oh, Eun-Song;Ahn, Ki-Beom;Jung, Kil-Jae;Ryu, Dong-Ok;Kim, Sug-Whan
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 2010년도 한국우주과학회보 제19권1호
    • /
    • pp.25.4-26
    • /
    • 2010
  • We present a three-mirror anastigmat(TMA) optical system for New Generation GOCI. In order to reduce the ghost optimized filter and baffle. By using carefully chosen antireflective coating and tilted filter angle, we fulfilled the design SNR requirement of 1500. We then designed a new entrance baffle and an internal baffle capable of producing the ghost ratio better than 0.01% of the nominal signal. The entrance baffle limits FOV to $0.75^{\circ}$ (E/W) $\times$ $0.60^{\circ}$ (S/N), and prevents the system from strong sun illumination, and the internal baffle prevents stray and scattered ray from entering into the telescope cavity. From these filter and baffle design, we confirmed that the instrument signal to noise ratio can be met with the current conceptual opto-mechanical design.

  • PDF

Stray Light Analysis of High Resolution Camera for a Low-Earth-Orbit Satellite

  • Park, Jun-Oh;Jang, Won-Kweon;Kim, Seong-Hui;Jang, Hong-Sul;Lee, Seung-Hoon
    • Journal of the Optical Society of Korea
    • /
    • 제15권1호
    • /
    • pp.52-55
    • /
    • 2011
  • We discuss the effect of stray light on a high-precision camera in an LEO(Low Earth Orbit) satellite. The critical objects and illumination objects were sorted to discover the stray light sources in the optical system. Scatter modeling was applied to determine a noise effect on the surface of a detector, and the relative flux of a signal and noise were also calculated. The stable range of reflectivity of the beam splitter was estimated for various scattering models.

낮은 조도에서 스마트폰 시청 후 시력 변화 (Change of Refractive Error after Watching Smart-phone under Low Intensity of Illumination)

  • 김봉환;한선희;권상진;김도훈;김미성;정현승;김학준
    • 한국안광학회지
    • /
    • 제19권1호
    • /
    • pp.105-109
    • /
    • 2014
  • 목적: 본 연구는 낮은 조도에서 1시간 동안 스마트폰을 시청 한 이후 시력변화와 NIBUT를 비교하였다. 방법: 20대(평균나이 $20.7{\pm}2.4$세)의 안질환이 없고 건강한 눈을 가진 50명(남자 22명, 여자 28명)을 대상으로 실험을 하였다. 낮은 조도(0 lx)에서 스마트폰(Galaxy 2, Samsung, KOREA)을 시청 전과 한 시간 시청 후의 타각적 굴절이상도 검사, 원거리 교정 시력과 NIBUT를 측정하였다. 타각적 측정은 Auto-chart Project(CP-1000, Dongyang, Korea), Phoropter(VT-20, Dongyang, Korea), Auto refractor-keratometer(MRK-3100, Huvitz, Korea)를 이용하였다. 결과: 낮은 조도에서 스마트폰을 시청하기 전과 한 시간 시청 후의 굴절이상도의 변화는 $-3.20{\pm}2.00$ D에서 $-3.38{\pm}2.00$ D로 변화했고(p=0.006), 원거리 교정시력의 변화는 $0.93{\pm}0.08$에서 $0.91{\pm}0.10$으로 변화했으며(p=0.000), NIBUT의 변화는 $10.48{\pm}7.00$ 초에서 $10.29{\pm}6.47$ 초로 변화했다(p=0.761). 결론: 낮은 조도에서 스마트폰을 지속적으로 시청하는 것은 일시적인 원거리 시력의 변화를 초래하였고, 적절한 휴식은 원거리 시력과 눈물 안정성에 미치는 영향을 줄여줄 것으로 사료된다.

패턴 분해능 및 초점심도 향상에 대한 사입사 조명 (Off-Axis Illumination)

  • 박정보;이성묵
    • 한국광학회지
    • /
    • 제10권6호
    • /
    • pp.453-461
    • /
    • 1999
  • 본 연구에서는 파장 0.248$\mu$m의 KrF Eximer Laser를 광원으로 하고 NA가 0.65인 광학계를 사용하는 리소그래피 시스템에서, 환형(annular)조명과 4구(quadrupole)조명의 조건들을 바꾸어 가며 구현하고자 하는 패턴의 분해능과 초점심도 향상에 어떠한 영향을 주는지 알아보았다. 그 결과, 환형 조명에서는 원형 마스크와 광학적 근접효과를 보정하기 위해 보조 패턴을 삽입한 마스크의 경우, 최적의 분해능과 초점심도를 보이는 조명조건이 다름을 알 수 있었다. 또한, 사구 조명의 경우에는 일반적으로 사용되는 45$^{\circ}$위치의 X자형 배치를 주요 패턴의 방향에 따라 적절히 바꾸어 주면 분해능과 초점심도를 향상시킬 수 있음을 확인하였다.

  • PDF

Dark Field Digital Holographic Microscopy Based on Two-lens 360-degree Oblique Illumination

  • Zhang, Xiuying;Zhao, Yingchun;Yuan, Caojin;Feng, Shaotong;Wang, Lin
    • Current Optics and Photonics
    • /
    • 제4권3호
    • /
    • pp.193-199
    • /
    • 2020
  • In this paper we propose a dark-field digital holographic microscopy system based on 360-degree oblique illumination. This setup is constructed without using a dark-field objective. The principle of 360-degree oblique illumination of vortex beam and dark-field digital holographic microscopy are introduced theoretically and experimentally. By analyzing the reconstructed image of a dark-field digital hologram of a USAF 1951 target, it is proved that the imaging resolution can be improved by this method. And also, comparison and analysis are made on the reconstructed image of a bright-dark field digital hologram of a pumpkin stem slice, the result shows that the imaging contrast is also enhanced with this method, and it is effective for dark-field digital holographic microscopy imaging of large transparent biological samples.

나사산 전면검사 비전시스템의 영상 균일도 향상을 위한 조명 광학계 설계 및 해석 (Design and Analysis of Illumination Optics for Image Uniformity in Omnidirectional Vision Inspection System for Screw Threads)

  • 이창훈;임영은;박근;나승우
    • 한국정밀공학회지
    • /
    • 제31권3호
    • /
    • pp.261-268
    • /
    • 2014
  • Precision screws have a wide range of industrial applications such as electrical and automotive products. To produce screw threads with high precision, not only high precision manufacturing technology but also reliable measurement technology is required. Machine vision systems have been used in the automatic inspection of screw threads based on backlight illumination, which cannot detect defects on the thread surface. Recently, an omnidirectional inspection system for screw threads was developed to obtain $360^{\circ}$ images of screws, based on front light illumination. In this study, the illumination design for the omnidirectional inspection system was modified by adding a light shield to improve the image uniformity. Optical simulation for various shield designs was performed to analyze image uniformity of the obtained images. The simulation results were analyzed statistically using response surface method, from which optical performance of the omnidirectional inspection system could be optimized in terms of image quality and uniformity.

초광각 변환기를 이용한 전방위 조명 광학계의 설계 (Optical Design of an Omnidirectional Illumination System Using an Ultra Wide Converter)

  • 이주호;유재명
    • 한국광학회지
    • /
    • 제35권1호
    • /
    • pp.18-23
    • /
    • 2024
  • 미술관 등 전시 공간에서의 조명은 바닥보다는 주로 전시물이 붙어 있는 벽면에 비춰져야 한다. 일반적으로 사용되는 LED 조명은 LED에 확산판이 결합된 형태로서 각도별 배광 분포가 일정한 램버시안 광원에 가까우며, 수직 입사가 이뤄지는 바닥면에 조명이 집중된다. 따라서 이러한 일반적 형태의 조명 방법은 벽면을 조명하기에는 적합하지 않으며, 벽면에 조명을 집중시키기 위해서는 각도별 배광 분포 중 각도가 큰 영역에서의 광량이 커지도록 해야 한다. 본 연구에서는 광원에서의 발산각을 180도로 확산시키기 위해 초광각 변환기를 사용하는 조명 광학계에 대해 논의하고자 한다.

생물 광자의 이차원 영상을 위한 렌즈계 최적화와 장치 구성 (Optimum Lens Organization and System Set-up for 2-Dimensional Imaging of Biophoton)

  • 이승호;심성보;김재순;양준모;이창훈;소광섭
    • 한국광학회지
    • /
    • 제15권6호
    • /
    • pp.519-526
    • /
    • 2004
  • 초 미약 생물광자의 이차원적 영상을 얻기 위해 고속 초고감도 CCD 사진기를 검출기로 사용한 실험 장치를 고안하였다. 본 장치에는 식물의 잎으로부터 방출하는 지연광 (delayed luminescence)를 발생시키기 위한 조명 장치를 설치하였으며, 조명 장치와 검출기에 있는 셔터들은 서로 연동되어 동작하도록 이루어졌다. CCD 사진기에 사용된 렌즈계는, 상용렌즈들로만 구성되었는데, 시료에서 나오는 생물광자의 집광 효율 (collection efficiency)을 높이도록 최적화된 렌즈 설계에서 나온 결과를 기초로 하였다. 이 장치들을 다용도 암 상자에 장착하여 사철나무 잎에서 나오는 지연광의 영상을 성공적으로 얻었다.

주파수 필터링 함수에 따른 시간 및 주파수 영역 광음향 측정에 대한 신호 대 잡음비 분석 (Signal-to-noise Ratio in Time- and Frequency-domain Photoacoustic Measurements by Different Frequency Filtering)

  • 강동열
    • 한국광학회지
    • /
    • 제30권2호
    • /
    • pp.48-58
    • /
    • 2019
  • 구면 초점 초음파 측정기에 의해 구형의 광 흡수체로부터 측정된 시간(즉, 펄스 형태 광원) 및 주파수 영역(즉, 처프 형태 광원) 광음향 신호의 신호 대 잡음비(signal-to-noise ratio)를 이론 및 시뮬레이션으로 분석하였다. 이전 문헌과 마찬가지로 시간 영역 광음향 측정에 의한 신호 대 잡음비 값이 주파수 영역 광음향 측정의 경우보다 더 높았는데 이 근본적인 이유를 최대허용노광량(maximum permissible exposure)에 따른 광원의 세기와 주파수 필터링을 통한 두 측정 모드의 광음향 스펙트럼들에 대한 분석을 통해 이해하였다. 또한, 분석의 결과로서 주파수 영역 광음향의 처프 형태 광원에 대한 정합 필터링에 더해 DC 스펙트럼 부분을 제거하니 신호 대 잡음비가 5 dB 정도 상승하는 것을 발견하였다. 특히, 주파수 필터 함수의 주파수 상한 값의 변화에 따라 신호대 잡음비 값이 급격하게 변동하였는데 신호 대 잡음비가 최대가 되는 주파수 상한 값이 두 광음향 측정 모드에서 서로 다르게 나타남을 관찰하였다.