• Title/Summary/Keyword: Illumination measurement

Search Result 234, Processing Time 0.022 seconds

A Study on the Outdoor Lighting Plan at Hoam Park in Chungju (충주 호암공원 야간경관 조명실태 및 개선방안에 관한 연구)

  • Chung, Yu Gun
    • KIEAE Journal
    • /
    • v.6 no.4
    • /
    • pp.51-56
    • /
    • 2006
  • As tourist and cultural city, Chungju city struggles to exploit the new tourism resources including lighting scenic spots. This study aims to analyze the present lighting situations and suggest the alternatives for improving outdoor lightings of Hoamji Park - one of the most famous landmark in Chungju city. For the purpose, field surveys and experiments were performed on selected settings. Illumination levels were measured to compare with the KS standard by using MINOLTA T-10 instruments and some findings were discussed. As a result, some alternatives to improve the park's night images including new lighting concept, lighting fixtures and installations were suggested.

Development of Holographic Particle Velocimetry System and Its Application to Spray Droplets (홀로그래피 입자속도 측정시스템의 개발과 분무 액적에의 적용)

  • Choo, Y.J.;Kang, B.S.
    • Journal of ILASS-Korea
    • /
    • v.10 no.3
    • /
    • pp.17-28
    • /
    • 2005
  • The Holographic Particle Velocimetry system can be a promising optical tool for the measurements of three dimensional particle velocities. In this study, diffused illumination holographic system to measure the sizes and 3D velocities of moving particles based on automatic image processing was developed. First of all basic optical systems for pulse laser recording, continuous laser reconstruction, and image acquisition, were constructed. To determine the position of particles in the optical axis, new three auto-focusing parameters(AEP), namely, Correlation Coefficient, Sharpness Index, and Depth Intensity were introduced and verified. The developed system was applied to spray droplets to validate the capability of the system. Three dimensional positions of particles viewed from two sides were decided using AFP and then 3D velocities of Particles were extracted by particle tracking algorithm. Comparison of measurement results of sizes and 3D velocities of particles with those obtained by laser instrument, PDPA, showed good consistency of the developed holographic system.

  • PDF

Characteristics of Polymer Solar Cells Depending on the Thickness of Active Layer

  • Lee, Dong-Gu;Noh, Seung-Uk;Suman, C.K.;Kim, Jun-Young;Lee, Seong-Hoon;Lee, Chang-Hee
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.1204-1207
    • /
    • 2009
  • We investigated the device performance of bulk heterojunction solar cells depending on the active layer thickness. For the systematic comparison, the polymer solar cells comprising RR-P3HT:PCBM (1:0.8 (wt%:wt%)) blend films with different thickness were characterized by impedance spectroscopy, and J-V measurement in dark and solar simulated illumination. The device with 120 nm thickness of active layer exhibited maximum power conversion efficiency of 3.5 % under AM 1.5 100mW/$cm^2$ illumination condition.

  • PDF

Development of Coaxial Monitoring System in Laser Arc Hybrid Welding for Automotive Body Application (자동차 차체 적용을 위한 레이저-아크 하이브리드 용접의 동축 모니터링 시스템 개발)

  • Park, Young-Whan;Rhee, Se-Hun;Kim, Cheol-Hee
    • Journal of Welding and Joining
    • /
    • v.27 no.6
    • /
    • pp.9-16
    • /
    • 2009
  • In this paper, the coaxial monitoring system to capture image of weld pool was developed in laser-arc hybrid welding. In order to obtain the reliable image, green laser was used as a illumination system and measuring components such as band pass filter, ND (Neutral Density) filter and shutter speed was designed and optimized. Using this monitoring system, weld pool images were captured according to laser power, welding speed, welding current and interspace between laser and arc through the experiment. ANOVA (Analysis of Variation) was carried out to identify the influence of process variables on bead widths extracted from captured images of monitoring system. Welding speed and current were major factor to affect weld pool.

Relaxation of Photogenerated Carriers under He, $H_2, Co_2 and\; O_2$ on ZnO

  • 한종수;김혜정;진준
    • Bulletin of the Korean Chemical Society
    • /
    • v.19 no.6
    • /
    • pp.676-680
    • /
    • 1998
  • The relaxation process of photogenerated carriers was investigated using conductivity measurement on ZnO under He, $H_2,\; CO_2\; and\; O_2$. The process was well explained with the rate constant of reaction or recombination of hole and electron, $k_h \;and\; k_e ( k_h > k_e)$, respectively. Generally, $k_h$ increased with the pressure of the gases. The slope of $k_h$ with respect to the pressure increased in the order of $H_2{\le}He, while $k_h$ of $O_2$ was sensitive to the history of the sample. The relaxation process on ZnO which was exposed to oxygen at 298 K and 573 K was observed during the illumination at 298 K and it was found that the rate constant of hole decreased with illumination time. From the result, it was suggested that the rate constant of photogenerated excess carriers was affected by the surface barrier of the semiconductor.

Study on Optimized Manual Development and Optimum Lighting System within Luminance-based Tunnel (휘도기반 터널내 운전자 적정조명시스템 개발 연구)

  • Lee, Mi-Ae;Kim, Yeon-Hwa;Han, Seung-Hun;Kim, Ji-Heon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.4
    • /
    • pp.18-29
    • /
    • 2015
  • The purposes of this research and development are as follows: first, to provide pleasant driving environments inside tunnels; second, to improve the current illumination environments lacking in diffusion luminance meters to meet tunnel lighting standards; and, third, to reduce the consumption of tunnel lighting energy accounting for approximately 65% of tunnel maintenance costs because of inadequate visual environments and tunnel operations. Further details are listed below. Firstly, an image luminance meter for tunnels that can implement the L20-method which is a tunnel luminance method that follows the international standards of CIE88, which was developed in order to improve and change the existing illumination-based tunnel lighting operation system to a luminance-based system. (The margin of error of below 5% according to the results of a test by an authorized agency and field test). Secondly, early illumination control is possible since the lighting control system that can be operated based on luminance enables interlocking control of the inside and outside of a tunnel using ethernet communication. Thirdly, guidelines for field application of the system are proposed. In addition, the luminance inducers of tunnels are found and the reflexibility of each facility that may reduce luminance of the boundaries is also proposed. Fourthly, as a result of a test bed, power consumption of luminance-based lighting operations decreased by 15.6% compared to illumination-based operations. Applying the feedback controls and maintenance factors of internal/external luminance meters, it reduced by 36.4%. Therefore, we became able to provide a luminance-based lighting operation system that complies with tunnel lighting design standards and provides a visual environment for drivers.

Heat Sink of LED Lights Using Engineering Plastics (엔지니어링 플라스틱의 LED조명 방열판 적용)

  • Cho, Young-Tae
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.12 no.4
    • /
    • pp.61-68
    • /
    • 2013
  • As an advance study for the development of a heat sink for special purpose high power illumination, an investigation was made to find feasibility for the application of copper plated EP to a heat sink of small LED light of less than 10W installed in commercial product. In this study, the plated heat sink with EP copper was fabricated for the conventional LED light. It was used actually for finding heat radiation property and effectiveness of the heat sink accompanied with measurement of luminous intensity. The heat is radiated by transfer and dissipation only through the copper plated surface due to extremely low heat conductivity of EP in case of EP heat sink; however the total area of the plate plays the function of heat transfer as well as heat radiation in case of the aluminum heat sink. It seems that the volume difference of heat radiating material is so big that the temperature $P_1$ is 9.0~12.3% higher in 3W and 42.7~54.0% higher in case of 6W volume difference of heat radiating material is so big that the temperature $P_1$ is 9.0~12.3% higher in 3W and 42.7~54.0% higher in case of 6W even though heat transfer rate of copper is approximately 1.9 times higher than that of aluminum. It was thought that this is useful to utilize for heat sink for low power LED light with the low heating rate. Also, the illumination could be greatly influenced by the surrounding temperature of the place where it is installed. Therefore, it seems that the illumination installation environment must be taken into consideration when selecting illumination. Further study was expected on order to aims at development of an exterior surface itself made into heat radiation plate by application of this technology in future.

Delayed Luminescence Characteristics of Human Hands (사람 손의 지연발광 특성)

  • Yang, Joon-Mo;Choi, Chun-Ho;Soh, Kwang-Sup;Lim, Woo-Taek;Lee, Han-Sang;Chae, Seung-Byung;Yoon, Se-Yeol;Lee, Kyung-Il;Shin, Eun-Seok;Choi, Sun-Mi
    • Korean Journal of Optics and Photonics
    • /
    • v.17 no.1
    • /
    • pp.81-88
    • /
    • 2006
  • Delayed luminescence from human hands after illumination by light at different wavelength bands was studied. A delayed luminescence measurement system equipped with photomultiplier tube (PMT), fiber optics and automatic mechanical shutter system was developed. Three spectrum band-pass filters, fer which transmissions are on 350${\~}$450 nm, 450${\~}$550 nm and 550${\~}$650 nm, were used to select irradiation wavelength, and 150W metal-halide lamp was used as an illumination source. Six volunteers put their palms (dorsa) onto the measurement system, and after light illumination, delayed luminescence were measured for 10 minutes. The results show that delayed luminescence after shorter wavelength illumination was higher than that a(ter longer wavelength one. These results indicate the existence of accepters in human skin which can be excited at short wavelengths. Furthermore, each subjects showed different delayed luminescence curve patterns. Reactive oxygen species (ROS) are known to have important roles on delayed luminescence, and this research suggests that ROS concentration can be measured noninvasively with optical methods.

Light Scattering Characteristics of Defects on Silicon Wafer Surface (실리콘 웨이퍼 미세 표면결함의 광산란 특성 평가)

  • Ha T.H.;Song J.Y.;Miyoshi Takashi;Takaya Yasuhiro
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.1083-1086
    • /
    • 2005
  • Light scattering measurement system that can evaluate light scattering characteristic from defects on silicon wafer surface has been developed. The system uses $Ar^+$ laser as an illumination source, and a highly sensitive photomultiplier tube (PMT) for detecting scattered light from defects. Unlike with conventional measurement system, our system has ability to measure scattered light pattern from wide range of scattering angles with changeable incidence condition. It is shown that our developed system is effective to discriminate the types and sizes of defects from basic experimental results using a microscatch and a PSL sphere.

  • PDF

Classification of Measurement Methods of Surface Plasmon Resonance Biosensors by SK Index (SK 지수를 이용한 표면 플라즈몬 공명 바이오 센서의 측정방법의 분류)

  • Lee, Seung-Ki
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.5
    • /
    • pp.342-349
    • /
    • 2004
  • SK (SPR Kinds) index, which can categorize the complicated measurement methods of surface plasmon resonance by simple method, has been proposed and verified. SK index is composed of three digits, where each digit presents the type of immobilized ligand, the type of illumination and the kinds of varying parameter, sequentially. The measurement method of (33#) series among SK indices shows the possibility of the multi-sensing capability, by which the response of 2-dimensional array of immobilized ligands can be detected simultaneously. The proposed possibility of multi-sensing capability has been verified by the modeling that is based on Fresnel reflection model.