• 제목/요약/키워드: Illumination Maintenance

검색결과 30건 처리시간 0.024초

시뮬레이션 프로그램을 활용한 교실조도 분식 및 개선안 (An Analysis of Classroom Illuminance with Simulation Program end Improvement of Classroom Illumination)

  • 신현만;장우진
    • 조명전기설비학회논문지
    • /
    • 제23권6호
    • /
    • pp.14-23
    • /
    • 2009
  • 학교 조명실태를 조사하고 교실 1실에 설치된 조명기구의 수량별로 분류하고, 분류된 형태별로 조도를 측정하여 조도실태를 분석하였다. 책상면 조도는 학교시설기준을 만족하나 칠판용 국부조명을 설치하지 않은 경우 칠판조도가 학교시설기준에 미치지 못하였다. 교실 마감재 반사율 측정과 램프교체 및 램프청소 실험 등, 실제로 측정한 자료를 기초로 하여 시뮬레이션한 결과 현실적으로 전반조명 9등과 칠판용 국부조명이 필요하였으며, 유지관리를 고려한 설계가 요구됨을 알 수 있었다.

강의실 조명설계의 경제성 평가 (Economical Efficient Evaluation of Lighting Design in Lecture Room)

  • 김덕구;오성보
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 춘계학술대회 논문집
    • /
    • pp.268-273
    • /
    • 2004
  • The visual environment in an educational building, apart from providing the comfortable seeing conditions needed for the performance of a wide variety of work tasks, must also satisfy the psychological and emotional needs of learners. This paper presents study on actual illumination environment of college and comparison of economical efficiency in order to figure out illumination problems. Furthermore, it attempts to suggest an optimum design of lecture room illumination through computer simulation. We try to evaluate economical efficiency of lighting design in lecture room under the illumination plan which is based on illumination maintenance and uniformity ratio that KS. illumination standard sets.

  • PDF

Approximate and Three-Dimensional Modeling of Brightness Levels in Interior Spaces by Using Artificial Neural Networks

  • Sahin, Mustafa;Oguz, Yuksel;Buyuktumturk, Fuat
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권4호
    • /
    • pp.1822-1829
    • /
    • 2015
  • In this study, artificial neural networks were used to determine the intensity of brightness in interior spaces. The illumination elements to illuminate indoor spaces were considered, not individually, but as a system. So, during the planned maintenance periods of an illumination system, after its design and installation, simple brightness level measurements must be taken. For a three-dimensional evaluation of the brightness level in indoor spaces in a speedy and accurate manner, the obtained brightness level measurement results and artificial neural network model were used. Upon estimation of the most suitable brightness level for indoor spaces by using the artificial neutral network model, the energy demands required by the illumination elements decreased. Consequently, in this study, with estimations of brightness levels, the extent to which the artificial neutral networks become successful was observed and more correct results have been obtained in terms of both economy and usage.

에너지 효율로 본 상업용 건물의 적정 창호에 관한 연구 (The optimal window system of office buildings considering energy efficiency)

  • 유호천;오영호;박승길
    • 한국태양에너지학회 논문집
    • /
    • 제25권4호
    • /
    • pp.53-60
    • /
    • 2005
  • The purpose of this study is to improve energy efficiency of windows in office buildings through the evaluation of their heating, cooling and illumination load. Energy efficiency is influenced by window size which is determined at the early stage of building design. The process of this study is as follows. First, energy performance is analysed according to the various rates of windows through computer simulation (ECOTECT). Then, the annual heating, cooling and illuminating loads according to the different window sizes are compared one another. Results indicated that the optimal window size considering energy efficiency is 50% of the surface area. When the window size is 50% of the surface area, annual maintenance expense is also smallest. Since the cost of cooling is larger than that of heating, too low indoor air temperature in summer is unfavorable based on the reasonable annual maintenance expenses.

시뮬레이션프로그램을 활용한 교실조도 분석 및 개선방안 (An Analysis of Classroom Illuminance with Simulation Program and Improvement of Classroom Illumination)

  • 신현만;장우진
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2009년도 춘계학술대회 논문집
    • /
    • pp.129-134
    • /
    • 2009
  • 학교 조명실태를 조사하고 교실 1실에 설치된 조명기구의 수량별로 분류하고, 분류된 형태별로 조도를 측정하여 조도실태를 분석하였다. 책상면 조도는 학교시설기준을 만족하나 칠판용 국부조명을 설치하지 않은 경우 칠판조도가 학교시설기준에 미치지 못하였다. 교실 마감재 반사율 측정과 램프교체 및 램프청소 실험 등 실제로 측정한 자료를 기초로 하여 시뮬레이션 한 결과 현실적으로 전반조명 9등과 칠판용 국부조명이 필요하였으며, 유지관리를 고려한 설계가 요구됨을 알 수 있었다.

  • PDF

휘도기반 터널내 운전자 적정조명시스템 개발 연구 (Study on Optimized Manual Development and Optimum Lighting System within Luminance-based Tunnel)

  • 이미애;김연화;한승훈;김지헌
    • 조명전기설비학회논문지
    • /
    • 제29권4호
    • /
    • pp.18-29
    • /
    • 2015
  • The purposes of this research and development are as follows: first, to provide pleasant driving environments inside tunnels; second, to improve the current illumination environments lacking in diffusion luminance meters to meet tunnel lighting standards; and, third, to reduce the consumption of tunnel lighting energy accounting for approximately 65% of tunnel maintenance costs because of inadequate visual environments and tunnel operations. Further details are listed below. Firstly, an image luminance meter for tunnels that can implement the L20-method which is a tunnel luminance method that follows the international standards of CIE88, which was developed in order to improve and change the existing illumination-based tunnel lighting operation system to a luminance-based system. (The margin of error of below 5% according to the results of a test by an authorized agency and field test). Secondly, early illumination control is possible since the lighting control system that can be operated based on luminance enables interlocking control of the inside and outside of a tunnel using ethernet communication. Thirdly, guidelines for field application of the system are proposed. In addition, the luminance inducers of tunnels are found and the reflexibility of each facility that may reduce luminance of the boundaries is also proposed. Fourthly, as a result of a test bed, power consumption of luminance-based lighting operations decreased by 15.6% compared to illumination-based operations. Applying the feedback controls and maintenance factors of internal/external luminance meters, it reduced by 36.4%. Therefore, we became able to provide a luminance-based lighting operation system that complies with tunnel lighting design standards and provides a visual environment for drivers.

프리즘 필름을 이용한 조명기구 설계 연구 (A Study on Light Guide Luminaire Design using Prismatic Film)

  • 정학근;한수빈;정봉만;이의준
    • KIEAE Journal
    • /
    • 제2권2호
    • /
    • pp.33-38
    • /
    • 2002
  • There are a number of practical uses for devices which are capable of piping large amounts of light: illumination of areas where there would be maintenance, safety, or security problems with electronic light sources; piping sunlight into indoor areas for illumination; and the conversion of high luminous efficacy, good color quality, high intensity discharge lamps into more acceptable linear of area sources of light. Prism light guides are hollow structures which pipe light by means of total internal reflectin(TIR). These devices are unique in their ability to combine the efficiency of TIR with the relatively low cost of hollow structure. An important application stems from their ability to transform a point source of light such as an incandescent or discharge lamp into a linear or area source of light or illumination. We report the development of an economical, flexible prismatic film for fabricating the light guide wall. This guide geometries and films are currently under development.

아파트 단지(團地) 외부공간(外部空間)의 빛 환경(環境)에 관(關)한 연구(硏究) (A Luminous Environment of Outdoor Spaces in Apartment Complexes)

  • 권소영;하미경;이효창
    • 한국주거학회:학술대회논문집
    • /
    • 한국주거학회 2006년도 추계학술발표대회 논문집
    • /
    • pp.237-241
    • /
    • 2006
  • The Qualitative improvements of outdoor spaces are unsatisfactory in comparison with that of indoor environment in existing apartments. Lately construction companies are differentiating the outdoor spaces of apartment complexes to meet needs of residents. However, high-rise buildings inherently have limitations on providing exposure to the outdoor settings and inappropriate lightings could have serious impacts on physical and psychological health of residents. Therefore, the purpose of this study is to provide useful information for the luminous environment of outdoor spaces through the analysis of current apartment complexes' lighting plans. Outdoor space of branded apartment complexes in Seoul, built after the year 2003, were researched. Through site visits, illumination level and lighting plans were investigated classified into entry area, passage area, plaza, rest area, exercise area, and play area. With the result, illumination level of apartment complexes researched was lower than KS illumination standard in all areas and the lighting plans were mostly shown in different condition of first intended lighting plan because of insufficiency of maintenance in lighting system. Therefore, it is need to provide better luminous environment to make outdoor space more lively and energetic at the night time.

  • PDF

터널 조명등 교체에 따른 전력사용량 및 조도 개선 효과: 저압나트륨램프 LED로 교체 (Effect of tunnel lighting replacement on power usage and illumination improvement: replacing low pressure sodium lamp with LED)

  • 이규필;김정흠
    • 한국터널지하공간학회 논문집
    • /
    • 제22권2호
    • /
    • pp.185-196
    • /
    • 2020
  • 국내 터널조명에는 저압나트륨램프, 고압나트륨램프, 형광램프 등이 주요 광원으로 사용되고 있으며, 터널 유지관리 비용 가운데 터널조명을 위한 전력요금은 가장 높은 비율을 차지하고 있는 것으로 알려져 있다. 따라서 터널조명은 낮은 소비전력, 장수명 등의 장점을 갖는 LED로 교체 중에 있다. 본 연구에서는 터널조명 LED 교체에 따른 효과 분석을 위하여 기존 터널조명이 저압나트륨램프인 8개소 터널에 대하여, LED 교체 전·후 터널 조도측정결과 및 1년간의 월별 전력사용량을 조사하였으며, 분석결과 터널조명 광원을 저압나트륨램프에서 LED로 교체 후 1년간 터널조명용 전력사용량은 26.1~59.6% 감소하였으며, 조도는 34.1~293% 향상된 것으로 나타났다.

SFC로 설계된 공정제어에서 Remote Control에 의한 선택 시퀀스 제어 방법 (A Method of Select Sequence Control by Remote Control in Process Control designed by SFC)

  • 유정봉
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.134-136
    • /
    • 2007
  • Sequential Function Chart(SFC) is very easy to grasp the sequential flow of control logic and has the compatability for a maintenance, In process control, when an error is occurred, to execute other routine by force, we control the process by remote control. In this paper, we proposed the method of select sequence control by remote control in process control designed by Sequential Function Chart(SFC).

  • PDF