• Title/Summary/Keyword: Illuminance ratio

Search Result 76, Processing Time 0.023 seconds

Status of Facilities, Equipment, and Environmental Hygiene Management of School Foodservices in Daiyue-district, Taian-city, China (중국 태안시 다이웨구 학교급식소의 시설·기구·환경 위생관리 실태)

  • Cheng, Xiao Xia;Moon, Hye-Kyung
    • Journal of the FoodService Safety
    • /
    • v.2 no.2
    • /
    • pp.59-66
    • /
    • 2021
  • The results of the inspection based on the sanitation checklist and the measurement of refrigerator/freezer temperature, illuminance, and ATP were conducted at 12 school foodservices in Daiyue-district, Taian-city, Shandong Province, China, at the same time, and the results were as follows. Five items of 'Use sterilized cutting boards', 'Use sterilized knives', 'Use worktable after sterilization', 'Use sink after sterilization', 'Sterilize the interior/exterior of the refrigerator regularly' in the checklist inspection were found not to be performed (0%). Two items of 'Disinfect hands after washing', 'Equipped with hand sterilizer' and 'Sterilize the kitchen areas regularly' were investigated as being performed only in one foodservice (8%). The average illuminance of the receiving stand were 373.08±106.35 Lux, 8% when the standard (540 Lux or higher) was complied with, the average refrigerator temperature were 7.06±0.82℃, 38.9% when the standard (-2 to 5℃) was observed 8% of cases complying with the standard (below -18℃) at -8.56±0.76℃ were investigated. As a result of ATP measurement, the surfaces of knife edge, cutting board, refrigerator door handle, worktable, and sink, which are not sterilized at all, were not suitable (accept ratio 0%), sterilized food plate (accept ratio 54.2%) and utensil for preserved food (accept ratio 75%) had a relatively high accept ratio. China's hygiene regulations should be revised in the direction of strengthening disinfection practices for facilities, equipment, and the environment, and hygiene measures such as education on disinfection and preparation of economical disinfection methods should be established.

Actual Conditions on the Illumination Environment of the Study Rooms in the Youth of an Agriculture Village (농촌 청소년 공부방의 조명환경 실태조사)

  • Kim, Hyun-Ji;Jun, Kyoung-Sun;Lee, In-Hyo;An, Ok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.4
    • /
    • pp.1-7
    • /
    • 2009
  • This study investigated the actual conditions of the illumination environment from agricultural youth study room. The result, average space of the study room was 11.42[$m^2$]. The illuminant uses the fluorescent lamp mainly, Method of using illumination was only general illumination the case which uses 73.8[%]. Method of light distribution was a direct lighting mainly. The house which has a stand illumination was also 45.7[%], The percentage using the stand illumination which was a local illumination was nothing but in 20[%] of the whole subject of investigation, therefore eye work could not effective. The internal illuminance was average 131.82[lx], the desk illuminance was 253.64[lx] which was the minimum permitted limit and poor. Uniformity ratio of illuminance appeared with average 35.61[%]. The satisfaction with 3.93 points to be high for illumination environment, therefore it was thought that the recognition of illumination was very insufficient.

Investigation Research on Illuminance/Luminance Ratio Appropriateness Applied in Road Lighting (도로조명에 적용되는 조도/휘도비의 적정성 조사 연구)

  • Lee, Sang-Jin;Kim, Ki-Hoon;Han, Jong-Sung;Kim, Hoon
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.217-222
    • /
    • 2002
  • 노면 반사특성에 관한 연구와 함께 국내에서 도로조명 설계시 적용하는 조도 휘도 환산계수에 관한 연구는, 휘도가 기준이 되는 도로 조명을 설계하는 데에 있어서 매우 중요하다. 현재 조도 휘도 환산계수를 이용하여 설계한 도로조명이 적정하게 유지되고 있는지 알아내기 위하여 실제 도로에서의 조도 및 휘도 분포를 측정하고 조도휘도 환산계수를 계산하였다.

  • PDF

A Simplified Daylight Prediction Method for Designing Sawtooth Aperture

  • Kim, Kang-Soo;Lee, Jin-Mo
    • Architectural research
    • /
    • v.2 no.1
    • /
    • pp.41-46
    • /
    • 2000
  • The sawtooth skylight is an excellent daylighting concept for the uniform interior illuminance over large working areas. In computer simulation, it is difficult for an architect to get accurate daylight illuminances for the spaces where sawtooth apertures are applied. In this study, daylight prediction algorithms for sawtooth apertures are developed. The flux transfer method is applied for this study to predict daylight illuminances. The simplified equations from this study can be used effectively for preliminary prediction of daylight in sawtooth spaces.

  • PDF

A Lighting Plan and Operation Strategy for Underground Parking Garages in Residential Areas (주거단지 지하주차장의 조명계획 및 운영방법)

  • Chang, Soo-Jung;Choi, An-Seop
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.4
    • /
    • pp.47-54
    • /
    • 2005
  • The improvement of perspectives on dark and limited underground space could be an important factor in successful underground space development. The Current trend in the apartment underground parking garages requires not only quantitatively energy efficient design and operation but also qualitative improvement of the space. For this, we need to consider two factors: Firstly, to understand the characteristics of the lamps; Secondly, to improve the uniformity ratio of illuminance. In a winter season, a way to keep the uniformity and a method not to lower the indoor illuminance level by cold ambient air should be established. Therefore, a change in interval and arrangement of the lighting fixtures is required. Also, in their operations, the current time-fixed control method needs to be changed into the control which method considers the use pattern.

Crime Prevention Through Environmental Design of Underground Parking in Commercial Facilities - Field survey of Underground Parking Spaces in Department stores, Large Discount Mart and Mixed Used Commercial Facilities - (상업시설 지하주차장의 CPTED계획요소에 관한 연구 - 대형마트와 백화점, 복합상업시설 지하주차장 현장조사 -)

  • Min, Young Hee;Kwon, Ju-Young;Ha, Mi-Kyoung
    • Korean Institute of Interior Design Journal
    • /
    • v.25 no.3
    • /
    • pp.129-137
    • /
    • 2016
  • Dark and desolate underground parking spaces in commercial facilities are optimal spaces for crime. First, this study reviewed 15 precedent CPTED guidelines and related literatures, and as a result extracted 45 CPTED planning criteria for underground parking facilities. Secondly by field survey, we investigated six parking spaces in commercial facilities whether they were planned properly based on 45 checklist items, in six categories of CPTED principles. In result, target facilities showed average 46.8% relevance ratio, which means less than a half of 45 items of CPTED planning factors were not applied. Guidelines suggest desirable illuminance level of more than 100 lux, however the measurement of illuminance levels in some parking spaces showed below 50 lux. Relatively department stores were keeping CPTED guidelines better than large discount mart and mixed used facilities. Definition of territory of loading dock and customer area should be clarified, clear signage and color scheme in different zones should be represented with higher level of territorial responsibilities and surveillance in mixed used facilities for further improvement.

Experimental Evaluation of the Lighting Environment for Main Activities of the Residents in Living Room (거실 거주자의 주요 행위에 적합한 조명환경 평가 실험)

  • Kim, Hyun-Ji;Woo, Seong Jun;Kim, Hoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.9
    • /
    • pp.6-14
    • /
    • 2013
  • The position of the light source, illuminance distribution, and color temperature were evaluated in each lighting environment for the three main activities in a living room - 'watching TV,' 'reading' and 'relaxing.' In 'watching TV', the experiment was done to estimate the degree of comfort felt by the subjects when they watch static video and moving video, respectably, with different ambient brightness, with or without partial lighting above the TV set, and with different color temperatures. In 'reading', the comfortableness was estimated by the illuminance ratio of the ambient lighting to the lighting for reading and by the difference in color temperature. And in 'relaxing', the comfortableness was estimated by means of the ambient brightness, use/no use of a relaxing lamp, and color temperature. This experiment determined the general satisfaction for each visual act and the optimum lighting environment to reduce glare.

A Study on the Evaluation of Lighting Performance in an Office Space (사무공간의 조명성능 평가에 관한 연구)

  • 김한성;김영민;김강수
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.6
    • /
    • pp.16-22
    • /
    • 2003
  • The purpose of this study was to provide visual evaluation data in a workstation space when different lighting types were applied. For the performance evaluation, Radiance program was used for simulations, and the mock-up room(15.0x11.6x3m) was used for the actual test. The results of this study were as follows; 1) When the inidirect lighting simulation data using Radiance was compared with the actual data in a small workstation space, there was a 6.5% difference. Therefore, Radiance program was proved to be useful for the evaluation of lighting performance. 2) Higher light levels (higher light ratio (%)) were recorded in the straddled layout and lower light levels (lower light ratio (%)) were recorded in the centered layout condition in most cases. 3) Also, the results show that the indirect luminaires and the straddled layouts provide higher uniformity, whereas the direct luminaires and the centered layouts have lower uniformity.

Evaluation of the daylight performance of adjacent interior spaces in four-sided atrium according to the height ratio of atrium, and the transmittance of atrium canopy (4면형 아트리움의 높이비와 천창 투과율에 따른 인접 실내공간의 자연채광성능 평가)

  • Yu, Ha-Nui;Lee, Ju-Yun;Song, Kyoo-Dong
    • KIEAE Journal
    • /
    • v.10 no.5
    • /
    • pp.57-62
    • /
    • 2010
  • Studies on daylighting of buildings have been continuously increased due to the recent escalating oil price and low-carbon strategies in developed countries. Daylighting of buildings not only saves electric energy, but provide the occupants with a comfort visual environment. Atrium spaces are adopted by many modern buildings to improve daylight performance of deep interior spaces. Among the various types of atria, the four-sided type atrium is frequently adopted by library buildings, governmental buildings and office buildings. This study aims to suggest daylighting design data for adjacent occupied spaces by conducting dynamic simulations using Daysim program. Daylight Factor(DF), Daylight Autonomy(DA) and Useful Daylight Illuminance(UDI) levels for 12 measurement points in adjacent occupied spaces were calculated for square-shape four-sided atria with different SAR(Section Aspect Ratio) and different canopy transmittance.

Simple Model of Bright-room Contrast Ratio Measurement System for Plasma Display Panels with Contrast Enhancement Film

  • Beom, Tae-Won;Park, Gi-Chan;Park, Jong-Rak;Kim, Young-Sik;Zhang, Jun;Song, Bu-Seup;Chun, Jong-Pil;Yoon, Ki-Cheol;Jang, Won-Gun
    • Journal of the Optical Society of Korea
    • /
    • v.15 no.1
    • /
    • pp.38-43
    • /
    • 2011
  • We have developed a simple model of a bright-room contrast ratio (BRCR) measurement system for plasma display panels (PDPs) adopting a contrast enhancement film (CEF) by using an illumination design tool. Only four model parameters were used, namely, total ambient illumination power delivered by fluorescent lamps, a panel scattering rate, illuminance of PDP white patterns, and the absorption coefficient of a color adjusting film. These parameters were determined by simple optical measurements and matching simulations. The proposed model was employed to predict the BRCR values of four different CEF samples, and the simulated ones were found to be in agreement with measured ones within about 10% relative-error.