• 제목/요약/키워드: Illuminance difference

검색결과 57건 처리시간 0.028초

축소모형을 이용한 광선반의 시환경 특성 평가 연구 (Visual Performance Evaluation Study of a Scaled Light-Shelf Model)

  • 조일식;김병수;이진숙
    • 한국태양에너지학회 논문집
    • /
    • 제23권3호
    • /
    • pp.63-71
    • /
    • 2003
  • According to the recent report, the lighting energy consumption of commercial buildings reaches to $30%\sim40%$ of the total energy consumption. It is more than that of cooling & heating energy consumption and it is the major target of energy-saving policy. It is obvious that they are interested in natural lighting device such as Light-shelf for the purpose of raising the lighting energy-saving efficiency. In most of highly developed countries, a thorough study on Light-shelf makes it possible to propose a practical plan while at home there leaves much to be desired to study a guiding principle of optimum plan in spite of its efficiency based on experiments using scale4 model and analysis of simulation. Aiming at making an optimum plan of Light-shelf suitable for the domestic situation, this study is worked by experiments using light-shelf and analysis of variables using illumination program. The experiments is to analyse the efficiency of Light-shelf on condition of the sky and the analysis is to make the simulation using illumination program. This study is composed of 1) the analysis of light with some variables such as presence of light-shelf and degree of angle using 1/2 scaled model 2) making the simulation using Lightscape, illumination program, In brief, concerning presence of light-shelf, it causes little difference in its efficiency in the overcast sky, whereas it decreases an illuminance of window side and provides inner side with the light, which decreases the ratio of the maximum to the minimum inner illuminance and makes the inner of illuminance to range evenly in the clear sky. On degree of angle, as the daylight increases in proportion of degree of angle, the ratio of the maximum to the minimum inner illuminance decreases, which makes it possible to increase the proportion of inner daylight.

조도 차이를 이용한 어류 차단 효과 분석 (Analysis of Fish Blocking Effect using Illuminance Difference)

  • 강준구;강수진;김종태
    • 한국산학기술학회논문지
    • /
    • 제18권9호
    • /
    • pp.76-83
    • /
    • 2017
  • 어류는 빛에 대해 민감한 반응을 보이므로 이를 이용한 어류 관리 기술 개발이 필요하다. 따라서 본 연구에서는 빛을 이용한 어류 차단 시설을 개발하였으며 국내 대표 외래어종인 배스와 블루길을 대상으로 조도 차이를 이용한 차단 효과를 분석하였다. 빛은 발광 다이오드를 이용해 발생시켰으며 바닥에서 수직 방향으로 향하게 설치하였다. 유속은 어류의 소상능력을 고려하여 총 3단계(0.2, 0.1, 0.05 m/s)로 구분하였으며 학습효과를 방지하기 위해 양육수조에서 1일 이상 휴식한 어류를 대상으로 실험하였다. 실험은 차단시설 적용 시 소상하는 어류 개체수와 차단시설 종료 후 소상하는 개체 수를 비교하는 방식으로 수행하였으며 차단 시설의 효과를 높이기 위해 일몰 후 수행하였다. 실험 결과 조도 차이에 따른 어류 차단효과는 높았으며 전반적으로 배스의 차단율이 블루길보다 낮았다. 전체 실험 개체수를 기준으로 배스의 차단율은 96.33%, 블루길의 차단율은 99.00%이며 소상 개체수를 기준으로 하면 배스는 91.73%, 블루길은 98.73%로 나타났다.

A Study on the Actual Condition of Illumination Environment in Public Libraries in Daegu

  • Seo, Ji-Eun;Kim, Hyun-Ji;Kim, Sung-Hwa;An, Ok-Hee
    • 조명전기설비학회논문지
    • /
    • 제23권3호
    • /
    • pp.1-9
    • /
    • 2009
  • This study investigated the actual condition focusing on the lighting environment which is a major element in aspect of indoor environment of a public library and assessed user satisfaction. Research results are as follows: Firstly, numbers of lighting fixtures per dimension of a reading room in a public library were inconsistent due to the lack of definite regulations, which was found to have negative effect on night time illuminance. Secondly, it was assessed that illuminance between the day time influenced by natural lighting and in the nighttime without natural lighting has more than 10-fold difference. Therefore, such a condition is judged to be inappropriate for lighting environment of a reading room where users spend a long time studying and thus, it is considered that an appropriate measures should be taken. Thirdly, as the survey result on users' satisfaction with lighting environment was revealed to be lesser than 3 points, lighting plan in consideration of its users should be progressed.

실내공간의 복합 환경 조건이 인체의 생리 및 심리반응에 미치는 영향 (The Combined Environmental Factors on the Human Physiological and Psychological Responses in Indoor Space)

  • 윤인
    • 한국산업융합학회 논문집
    • /
    • 제15권3호
    • /
    • pp.87-94
    • /
    • 2012
  • Kruithof demonstrated the preferred combination of illuminance levels and color temperatures. However, as Benett pointed out, difference of themal variables in such preference may be expected. The purpose of this study is to clarify the combined effects of lighting conditions(illuminance, color temperature), operative temperature on the human physiological and psychological responses. In order to observe operative temperature change in preference of color temperatures for three illumination levels, three subjects were exposed to two different conditions of color temperatures of 2,850K, 4,200K and 6,850K combined with operative temperatures(OT) of $25{\sim}31^{\circ}C$ at 100~1000lx. Thermal sensation vote and comfortable sensation vote, brightness perception vote were reported in each experiment conditions. The following results were obtained : 1) When illuminace level was at 100lx in operative temperatures of OT $20^{\circ}C$, $25^{\circ}C$, $30^{\circ}C$, Color temperature affect not themal sensation but Warm-cool sensation. 2) Operative temperatures affect not brightness perception vote but visual comfort sensation vote, satisfactive sensation vote, warm-cool sensation vote and themal sensation vote.

LED 조명의 분광 분포에 따른 건물에너지 소비 (Energy consumption by Spectral Power Distribution Of LED lighting)

  • 정호연;김효인;김곤;윤근영
    • KIEAE Journal
    • /
    • 제12권3호
    • /
    • pp.101-106
    • /
    • 2012
  • Lighting energy accounts for approximately 20% of the electrical energy used worldwide. Thus, High efficiency Light emitting diode(LED)lighting is getting more popular as the next generation lighting replaced to traditional lighting fixtures. Also, LED lighting not only has a long lifetime but also can realize a variety visual environments through the wavelengh control. The lighting energy varies depending on the Spectral Power Distribution(SPD) even though the Illuminance level is same. Therefore, This study indicates that the difference of indoor energy consumption under the same illuminance level when Spectral Power Distribution(SPD) is different. As a result, Lighting energy consumption under red-color emphasizing SPD is about 10% lower than under blue-color emphasizing SPDs.

자연채광방식의 응용에 따른 시각적 쾌적성에 관한 연구 (A Study on Visual Comfort for Light Control Method of Applied Daylighting)

  • 한상필;한상철
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.140-145
    • /
    • 2012
  • The purpose of this study is to understand the change of impression by comparing the uniformity lighting with the compound lighting. In previous study, we proposed a light controlling method to harmonize daylight from a window and artificial lights from a ceiling and obtained the results to support our method. We referred this method as the Adjusted Compound-Lighting Model (AC Model). The model claims that lighting in a room with a side-window are perceived as harmonious when the overall light distribution in the room is well approximated by a compound of lights from the window and the entire ceiling. The experiment is carried out with the scaled-models and mock-up spaces that were supposed to be an office space. One is lit by the uniform lighting and the other by the compound lighting in each experimental space. In order to present varying illuminance distributions, thetwo variables were used in this study. One was the ratio of thelight from the window and ceiling in the standard and evaluation box. The standard box was provided by the ratio of 20% to 40% from the window and 80% to 60% from the ceiling as two lighting ratio patterns [Wu20(=Cu80) and Wu40(=Cu60)]. And the evaluation box was provided by the light ratio of 0% to 40 from the window and 100% to 60% from the ceiling [Wcp0(=Ccp100), Wcp20(=Ccp80) and Wcp40(=Ccp60)]. The other variable was themean illuminance level in both boxes. Two level of mean illuminance (700lx and 300lx) were used in this experiment. Each lighting condition was established at equal horizontal mean illuminance level, held constant near 700lx or 300lx in both boxes. Both of them were similar in the shape of distribution when there were same ratios of lights from the window and the ceiling. Subjects were asked to evaluate the point of difference by semantic differential rating on their overall impression after comparing with two rooms. The results showed that the impressions of compound lighting were more positive score than that of uniformity lighting on the items of 'dim-bright', 'dislike-like', 'artificial-natural' and 'closed-open', and that there was no significant difference in impressions between two spaces on other items.

  • PDF

주행 중 운전자의 HUD 인지성과 활용성 평가 (Evaluation for the cognition and usability of HUD while driving)

  • 윤보람;박다은;김보경;조주영;박영경
    • 감성과학
    • /
    • 제17권3호
    • /
    • pp.117-128
    • /
    • 2014
  • 자동차사고의 주요 원인으로 운전자의 주의분산이 지목됨이 따라 운전자의 전방주시율을 높여주는 HUD(Head Up Display)에 대한 중요성이 높아지고 있다. 최근에는 다양한 콘텐츠가 포함된 HUD 제품들이 등장하면서 주행중 인지부하가 증가할 가능성이 높아졌다. 이에 본 논문은 현재 자동차에 사용되고 있는 HUD에 제시된 콘텐츠가 운전자에게 미치는 영향에 대해 알아보기 위하여 조도환경과 성별의 차이를 두어 인지적 측면과 활용적 측면에 대한 실험을 진행하였다. 실험 결과, HUD가 제공하는 콘텐츠는 외부 조도와 차량 내의 내부 조도의 차이가 클수록 시인성이 높아 인지부하가 줄어들었다. 또한 HUD 콘텐츠의 경우 주행과 직접적인 관련이 높을수록 인지율이 높았으며, 운전과 관련성이 낮은 콘텐츠의 경우 운전자의 집중을 저해하는 것을 확인하였다.

박물관의 조명환경 계획에 대한 소고 (An Approach to the Design of Museum Luminous Environment)

  • 김홍범
    • 보존과학연구
    • /
    • 통권16호
    • /
    • pp.139-154
    • /
    • 1995
  • In this paper the fundamental elements relevant to schematic daylighting design for museum are discussed and suggested. The illuminance difference between outdoor and exhibition space in consideration of the constraints necessary for the conservation of artifacts can be solved by conversion into Luminance. Also it is considered that transition zone in two stages should be provided for adaption before entering exhibition space and overall luminance within the visual field along viewing circulation should be balanced including the apertures designed for introducing the daylight or visual linking.

  • PDF

거실 거주자의 주요 행위에 적합한 조명환경 평가 실험 (Experimental Evaluation of the Lighting Environment for Main Activities of the Residents in Living Room)

  • 김현지;우성준;김훈
    • 조명전기설비학회논문지
    • /
    • 제27권9호
    • /
    • pp.6-14
    • /
    • 2013
  • The position of the light source, illuminance distribution, and color temperature were evaluated in each lighting environment for the three main activities in a living room - 'watching TV,' 'reading' and 'relaxing.' In 'watching TV', the experiment was done to estimate the degree of comfort felt by the subjects when they watch static video and moving video, respectably, with different ambient brightness, with or without partial lighting above the TV set, and with different color temperatures. In 'reading', the comfortableness was estimated by the illuminance ratio of the ambient lighting to the lighting for reading and by the difference in color temperature. And in 'relaxing', the comfortableness was estimated by means of the ambient brightness, use/no use of a relaxing lamp, and color temperature. This experiment determined the general satisfaction for each visual act and the optimum lighting environment to reduce glare.

SLR 디지털카메라의 식생관측센서로서의 유효성 검토 (The Availability Examination for Vegetation Measurement of The SLR Digital Camera)

  • 김종환;김응남;전병덕;삼산화일
    • 한국측량학회지
    • /
    • 제27권1호
    • /
    • pp.683-692
    • /
    • 2009
  • 디지털 카메라를 이용한 지상형 원격탐사 기술은 농작물의 생육관리, 법면 녹화의 모니터링 및 환경 평가와 같은 식생평가분야에 유용한 기술로서 기대되고 있다. 본 논문에 서늘 일반적인 목적으로 판매되고 있는 디지털 카메라의 식생 평가분야에의 적용 가능성에 대하여 검토하였다. 그 결과, $\gamma$보정, 적정노출보정을 실시함으로써 시계열 관측 데이터간의 상면조도와 입사 에너지간의 관계를 분석할 수 있었다. 또한, 지상형 원격탐사에 있어서의 촬영 각도, 조도의 영향을 보정하기 위한 모델식을 제안하였다. 평가시험에서는 분광광도계와 디지털 카메라에 의해 구한 NDVI에는 높은 상관관계가 있음을 알 수 있었다.