• Title/Summary/Keyword: Illuminance difference

Search Result 57, Processing Time 0.021 seconds

Prediction of Reduction Rates of Daylight Illuminance for Blind Conditions in a Small Office (소규모 사무실의 블라인드 조건에 따른 주광조도 감소비율 예측)

  • Gu, Renyan
    • Land and Housing Review
    • /
    • v.12 no.2
    • /
    • pp.79-89
    • /
    • 2021
  • This simulation based study analyzed the horizontal daylight distribution on the floor and ceiling of a small office space based on window orientations and interior window blind positions. South and north facing windows were each tested without window blinds and with window blinds at 45° and 180° (horizontal). The study showed that the illuminance value was highest 1m from the window. On the floor and ceiling, the difference in illuminance value was the greatest and least in December and June, respectively. The indoor illuminance value was highest when there was no window blind and under south-facing conditions. The greatest illuminance difference occurred between window blinds positioned at 45° and 180°. Under north-facing conditions, windows without blinds or with blinds at 45° had the least impact on indoor illuminance with illuminance being more evenly distributed.

Image Sensor Module for Detecting Space Illuminance in Indoor Environment (실내 환경의 공간조도 검출을 위한 이미지센서모듈)

  • Moon, Seong-Jae;Lim, Yeong-Seog
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.7
    • /
    • pp.771-778
    • /
    • 2019
  • The traditional illuminance intensity detection method using a single sensor has a problem that uniformity of illuminance detection is deteriorated depending on the measurement position due to the narrow FOV characteristic. In order to overcome this problem, a method of detecting an average illuminance value through a plurality of illuminance sensors is used, but the complexity and detection error are increased. In this paper, we propose a illuminance intensity detection method based on a single image sensor with wide FOV. The proposed method can solve the problems such as system complexity and error increase of existing illuminance sensor. The test results show that the difference of average value is 12% using a illuminance sensor, 10.7% using five illuminance sensors, and 6.2% using an image sensor compared with the reference value using the color difference illuminometer. It is confirmed that the proposed method can easily and accurately detect the space illuminance with improved uniformity.

Analysis of the Illuminance Distribution on the Blackboard in Classroom of the Elementary and Senior (Junior) High School (초.중.고교의 흑판조도분포 분석)

  • Kim, Tae-Hyoun;Sun, Sang-Kweon;Park, Tong-Wha
    • Proceedings of the KIEE Conference
    • /
    • 1997.07e
    • /
    • pp.1764-1766
    • /
    • 1997
  • In this paper, the illuminance distribution of blackboards on classroom in elementary, junior, and senior high school was measured and analyzed. Generally, average illuminance and uniformity of illuminance was 519[lx] and 0.543 (elementary: 389[lx], 0.387; junior: 632[lx], 0.570; senior: 527[lx], 0.608) respectively. When all lighting fixtures in each classroom were turned on, average illuminance was higher about 65% than lights-out, and, in case that local lighting fixtures exist, was higher 27% than absence, but uniformity of illuminance turned bad on the contrary ($0.462{\rightarrow}0.676$). According to classification into direction of windows on classroom. facing north, both were bad. In case of classroom to slant to east or west, the difference of illuminance at the forenoon and afternoon was big, and uniformity of illuminance was also bad.

  • PDF

Evaluation of Daylighting Performance in Office Building with Detailed Global Illuminance Data of Selected Korean Cities (정밀 전천공조도 데이터를 활용한 국내 주요도시 업무용 건물의 자연채광 활용성능 평가)

  • Choi, Su-Hyun;Shin, Sang-Yong;Seo, Dong-Hyun
    • Journal of the Korean Solar Energy Society
    • /
    • v.36 no.6
    • /
    • pp.37-46
    • /
    • 2016
  • In this study, long-term global illuminance data for 19 selected cities are calculated from modeled solar radiation data, AEER's TMY2. Perez model in Daysim daylight simulation tool is used for the solar radiation to illuminance conversion. And then, daylight availability in an unit office space is evaluated for the 19 cities. For this evaluation, various daylight performance indices are reviewed since static daylight performance index such as daylight factor (DF) and annual average global illuminance value is not suitable for actual performance evaluation in terms of visual comfort and light energy saving of a space. This study evaluated daylighting performance of prototypical office space module by introducing DA (daylight autonomy) and UDI (Useful Daylight Illuminance) index for major cities of Korea. Result shows that there is upto 18% of illuminance level difference with annual average global illuminance data, but if we consider useful daylight in a space the illuminance level difference among the cities are only within 5%. This means that for sustainable building design especially in daylight design, amount of annual global illuminance is not important factor even in cloudy cities. Daylight design and daylight harvesting system would return similar energy saving impact regardless of building location.

Analyses of the Impact of Atmospheric Conditions to Daylight Illuminance in a Small Space (기상인자의 변화에 따른 소규모 공간에서의 주광조도분석)

  • Kim, Soo-Young
    • Journal of the Korean Solar Energy Society
    • /
    • v.24 no.2
    • /
    • pp.17-23
    • /
    • 2004
  • Daylight illuminance levels in a small space were calculated using the Superlite program under limited conditions of the turbidity and thickness of condensible water of atmosphere. Three sky conditions(clear sky with direct sun, clear sky with no direct sun, overcast sky with no direct sun) were used. The atmospheric conditions significantly impacted the illuminance levels under especially a clear sky with direct sun. The overcast sky with no direct sun provided no difference for the illuminance levels in the space. As the calculation points moved away from a window, reflected illuminance levels gradually increased but direct illuminance levels significantly decreased.

The prediction of reduction ranges of daylight illuminance in small office for sky and shading conditions (천공 및 차양조건에 따른 소규모 사무실의 주광 조도 감소범위 예측)

  • Jang, Seo Yeon
    • Land and Housing Review
    • /
    • v.10 no.3
    • /
    • pp.33-41
    • /
    • 2019
  • This study examines the distributions of daylight illuminance in a small office space under clear and cloudy sky conditions. Three shading conditions using Venetian blinds were applied for the analysis of daylight illuminance. Computer simulations using the Lightscacpe were conducted for the daylight conditions applied to the office space. Results indicate that the illuminance differences between clear and cloudy sky for south-facing conditions were greater than those for north-facing conditions. The differences in December and June were the greatest and smallest, respectively. For the north-facing conditions, the daylight illuminance at 10:00, 12:00 and 14:00 in June and September under the cloudy sky was higher than those under the clear sky conditions. For all daylight conditions, the biggest amount of illuminance reduction occurred when the shading device conditions were changed from the no blind to the 45 degree blinds. As the distance from window increased, the shading effect that occurred when the shading device conditions were changed from the horizontal blind to the 45 degree blinds increased.

A Study on the Sense of Continuity between Two Rooms by Adjusting the Illuminance and The Color Temperature of Lighting (조명의 조도 및 색온도 제어에 의한 실내 두 공간의 공간감 변화)

  • 윤혜림
    • Korean Institute of Interior Design Journal
    • /
    • no.33
    • /
    • pp.83-89
    • /
    • 2002
  • This paper describes the experiments to examine the sense of continuity produced by lighting between physically separated spaces. Tolerable limits of illuminance were measured for providing a sense of continuity between two rooms connected by a window. In the experiments the illuminance and color of lighting of the subjects room were changed while those of the other room were kept constant. The results show that the observers could certainly determine the range of optimum illuminance for them to recognize continuity, and the variance of the results between observers is very small. Moreover, the tolerable range of illuminance was almost constant as far as the color difference was less than some critical value. This finding would be helpful in designing a lighting system for providing a sense of continuity.

Study on the UV illuminance to improve on attraction effect of fluorescent bait cage for pots (통발용 형광 미끼통의 유인 효과 개선을 위한 자외선 조도에 관한 연구)

  • Chang, Ho-Young
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.47 no.4
    • /
    • pp.316-326
    • /
    • 2011
  • In this study, the entrapped number is investigated on the UV light with different illuminance to fluorescent bait cage for swimming crab in order to find the appropriate illuminance which has the best attraction effect of fluorescent bait cage for pots. In addition, preference to the light, arrival time and residence time at light area are compared and analyzed to fluorescent bait cage and non-fluorescent bait cage for American lobster at the UV light and ordinary light according to the illuminance condition. Pot with red non-fluorescent bait cage at the no lighting (<0.01lux), pot with blue fluorescent bait cage at the 20W UV lighting (0.16lux) and pot with blue fluorescent bait cage at the 30W UV lighting (0.22lux) were soaked for 6 hours and the entrapped number of swimming crab was examined. The mean entrapped number of swimming crab in pot with red non-fluorescent bait cage at the no lighting (<0.01lux) was 1.0, but the mean entrapped number of swimming crab in pot with blue fluorescent bait cages at the 20W UV lighting (0.16lux) and 30W UV lighting (0.22lux) were 1.4 and 0.4, respectively (P<0.05). The rate of preference to the blue fluorescent bait cage at the UV lighting shows 1.6-4.8 times higher than that of preference to the red non-fluorescent bait cage at the ordinary lighting. In addition, The rate of preference to the blue fluorescent bait cage at the UV lighting is higher when the illuminance of ordinary light is same as or is lower than that of UV light (P<0.05). However, the preference to the light depending on gender shows no significant difference (P>0.05). The arrival time to UV light area of lobster is shown as 1.2-2.4 times faster than that to ordinary light area. Generally, it is shown that arrival time to UV light area is faster than the arrival time to ordinary light area when the illuminance of ordinary light is the same as or lower than that of UV light (P<0.05). However, arrival time to the light area depending on gender shows no significant difference (P>0.05). The residence time at UV light area of lobster is 1.2-1.7 times longer than that at ordinary light area. The residence time depending on different illuminance of ordinary light and genders showed no significant difference (P>0.05).

A Development of a LED Stand Using Illuminance Sensor for Efficient Energy Saving (효율적인 에너지 절감을 위한 센서 LED 스탠드 개발)

  • Chun, Sung-Yong;Shin, Ji-Yea;Park, Shin-Won;Yi, Hwa-Cho;Lee, Chan-Su
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.9
    • /
    • pp.1-7
    • /
    • 2012
  • In this paper, we present a new lighting control method considering ambient light in addition to the required lighting illumination for efficient energy saving of a LED stand. We estimate accurate environmental illuminance using a cheap illuminance sensor by modeling measured- and actual-illuminance using quadratic polynomial approximation. The relation between PWM(Pulse Width Modulation) duty ratio and illuminance intensity is modeled by a linear model. Illumination of the LED stand is controlled by estimating the difference of required illumination and the estimated ambient illumination. The developed LED stand has reduced electric energy consumption compared with a conventional manually controlled LED stand with the same lighting source. In addition, human subject evaluation shows that the LED stand, which is applied the proposed method, is more satisfactory than conventional ones since the proposed automatic controlled illumination produce more accurately required lighting and it is convenient.

An Experimental Study to Determine Proper Lighting Conditions in Powder Rooms

  • Kim, Hyun-Ji;Lim, Jang-Hyeon;Kim, Hoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.12
    • /
    • pp.54-62
    • /
    • 2013
  • In this study, a mock powder room was installed with variable LED lighting environments in order to conduct the experiments. The experimental conditions include luminaire type, illuminance ratio, vertical illuminance and color temperatures. The evaluation methods used were the Semantic Differential Method and a subjective evaluation on activities through observation. The SD evaluation result factor analysis categorizes ideas into three factors: brightness, emotion, and glare. The vertical bracket or the combined luminaire (luminous panel+ Vertical bracket) has better brightness than luminous panel. A vertical illuminance of 500lx is not significantly difference as compared to 600lx, allowing 500lx to be considered standard. The emotional atmosphere is evaluated as being better at lower color temperature. The luminous panel is the best for reducing glare while the vertical bracket is the worst. The best conditions differ according to the illuminance ratio of the luminous panel and vertical bracket. In the subjective evaluation (satisfaction with lighting environment, suitability to activity) the combined luminaire and 4000K received the best evaluation.