• Title/Summary/Keyword: Illuminance Measurement

Search Result 79, Processing Time 0.029 seconds

Measurement of Bangudae Rock Joint Using Non-adhesive, Non-contact Inclinometer Slope Laser Measuring System (비부착, 비접촉 방식의 계측기를 이용한 반구대암각화 암반 절리면의 계측)

  • Kim, Jae Hyun;Lee, Sang Ok;Chung, Kwang Yong;Han, Min Su
    • Journal of Conservation Science
    • /
    • v.37 no.6
    • /
    • pp.617-625
    • /
    • 2021
  • Daegokcheon Stream in Daegok-ri, Ulju-gun, is an area with a developed valley and bedrock from Gajisan Provincial Park to the confluence of the Taehwa River across the Yangsan Fault. To measure the rock of Bangudae petroglyphs, the mineralogical weathering, joints, and scours or cavities at the bottom were confirmed. The measurement was carried out for a short period of time on the joint of the bedrock on which the Bangudae petroglyphs were engraved. Compared to the measured value obtained using existing optical fiber (Ch4 150 ㎛), a displacement value of 300 ㎛ was obtained using the non-attached, non-contact type of measuring instrument. In the future, it is inferred that this instrument could be used for various cultural properties if the HSV-value suitable for illuminance and various measurement experiences are stored.

Measurement and Simulation of Interior Luminous Environment for the Decision Process of Building Remodeling (건물 개보수의 의사결정과정에서 필요한 실내의 빛환경 측정 및 시뮬레이션 -사례중심으로-)

  • 최안섭;성민기
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.15 no.5
    • /
    • pp.8-13
    • /
    • 2001
  • The make a decision for building remodeling, the economical value of the remodeled building should be analyzed and existing situation of the building system should be checked. For the energy issues related to the building remodeling process, careful diagnosis and re-designs of existing system should be proposed. In this research, the luminous environment for Seoul K Co. headquaters and Seoul S hotel were measured and then the re-design processes of building illumination systems were researched. With measured illuminance quantities of there cases, computer simulations for the existing situation and re-design were conducted.

  • PDF

A Study on Driver's Perception over the Change of the Headlamp's Illuminance : 2. Driver's Perception Property (전조등 조도변동에 대한 운전자의 인식연구 : 2. 운전자의 시인 특성)

  • Kim, Gi-Hoon;Lee, Chang-Mo;Jung, Seun-Gun;Jo, Duk-Su;Suk, Dae-Ill;Jo, Mun-Seong;Kim, Hyng-Keon;Kim, Huyn-Ji;An, Ok-Hee;Kim, Hoon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.10
    • /
    • pp.1-12
    • /
    • 2007
  • Through this experiment driver's perception were measured. An analysis of the perception measurement result analyzed the subject's obstacle perception response time according to voltage patterns. The difference in the reaction time between men and women was also analyzed. Futhermore, the obstacle perception response time was analyzed according to the rate of the brightness of the headlamp. The relative delay time was analyzed In reference to times when there was no voltage change.

A Study on the Standby Power Characteristics of Sensor Luminaires (광원별 센서등기구의 대기전력 특성에 관한 연구)

  • Park, Chang-Yong;Seo, Jeong-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.10
    • /
    • pp.9-15
    • /
    • 2014
  • Standby power, so called an electric vampire, is a power which is consumed by appliances and office equipments connected to power sources while the devices are not performing. Sensor luminaires consist of PIR(Pyroelectric Infrared Ray) sensor, illuminance sensor(CdS), and light source. The sensor luminaires are one of the devices that consume a huge amount of standby power; it stands by for an average sum of 23 hours a day and performs only when moving subjects are detected under it, which barely takes up an hour per day. The purpose of this study is to provide basic materials to the selection of standby power items and to enable to explore a way to decrease the standby power by measuring and analyzing the power consumption of sensor luminaires. According to the results, the average standby power of LED sensor luminaires is 1.1W which is significantly higher than other products, and decrease in the standby power consumption of SMPS is important through the measurement.

A Study on Driver's Perception over the Change of the Headlamp's Illuminance : 4. Test and analysis of Driver's brain wave (전조등 조도변동에 대한 운전자의 인식연구 : 4. 운전자의 뇌파측정 및 분석)

  • An, Ok-Hee;Kim, Hyun-Jin;Kim, Gi-Hoon;Kim, Hoon;Kim, Hyun-Ji
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2006.05a
    • /
    • pp.125-130
    • /
    • 2006
  • In this study, tests of brain waves were carried out to investigate the driver's physiological characteristics by the change of the headlight. The participants were 20 men in their 20s and twenty-three different conditions in combinations of waveform of light, voltage, and alteration time were used. The measurement of the brain waves was performed by internationally standardized 10-20 method using LXE3232-RF. The results were analyzed by Power Spectrum Analysis using alpha-, and beta-wave and by the analysis of different brain domains using Brain wave Map. The results were as follows. 1. From the results of the Brain wave Map analysis, it was suggested that A waveform increases mental stress and B waveform affects mental and visual stress. The longer the stimulation time, the more stress level was detected. 2 The voltage alteration time of B waveform should be kept less than 1500msec, and the voltage should not fall below 11.5V.

  • PDF

The Field Survey of Indoor Environment of the Office Building (오피스 건물의 실내 환경 실태 조사)

  • Yang, Young Kwon;Kang, In Sung;Chung, Min Hee;Moon, Jin Woo;Park, Jin Chul
    • KIEAE Journal
    • /
    • v.16 no.3
    • /
    • pp.71-76
    • /
    • 2016
  • Purpose: This study aimed at improving the indoor environment of the office building by measuring the indoor environment and conducting a survey. Method: The measurement was conducted from January 13 to March 16 in 2012, targeting 44 sites in same office building located in Seoul, South Korea. The lists of measurement such as dry-blub temperature, relative humidity, formaldehyde (HCHO), asbestos, carbon monoxide (CO), carbon dioxide (CO2), volatile organic compounds (VOCs) and particle pollution (PM10) were measured. In addition, illuminance which belongs to light environment and noise in sound[acoustical] environment were measured respectively. Result: The buildings showed overall pleasant conditions. In terms of the thermal, air, sound, and visual environment, each measurements were satisfied with the requirements in standard, within pleasant ranges, except several sites. However, the survey results were revealed that the office workers were mostly dissatisfied with their indoor environment. Given that the measured values were mostly within standards, the results of survey might have resulted from a compensation mentality biased toward the subjects in psychological terms.

Design and Implementation of Wireless Lighting LED Controller using Modbus TCP for a Ship (Modbus TCP를 이용한 선박용 무선 LED 제어기의 설계 및 구현)

  • Jeong, Jeong-Soo;Lee, Sang-Bae
    • Journal of Navigation and Port Research
    • /
    • v.41 no.6
    • /
    • pp.395-400
    • /
    • 2017
  • As a serial communications protocol, Modbus has become a practically standard communication protocol and is now a commonly available means of connecting industrial electronic devices. Therefore, all devices can be connected using the Modbus protocol with the measurement and remote control on ships, buildings, trains, airplanes and more. The existing Modbus that has been used is based on serial communication. Modbus TCP uses Ethernet communication based on TCP / IP which is the most widely used Internet protocol today; so, it is faster than serial communication and can be connected to the Internet of Things. In this paper, we designed an algorithm to control LED lighting in a wireless Wi-Fi environment using the Modbus TCP communication protocol, and designed and implemented a LED controller circuit that can check external environmental factors and control remotely through the integrated management system of a ship. Temperature, humidity, current and illuminance values, which are external environmental factors, are received by the controller through the sensors, and these values are communicated to the ship's integrated management system via the Modbus protocol. The Modbus can be connected to Master devices via TCP communication to monitor temperature, humidity, current, illuminance status and LED output values, and also users can change the RGB value remotely in order to change to the desired color. In addition, in order to confirm the implementation of the controller, we developed a simulated ship management system to monitor the temperature, humidity, current and illumination conditions, and change the LED color of the controller by changing the RGB value remotely.

The comparison between measurement and prediction values for the vertical illuminances by relux program in the survey region (상용 조명해석 프로그램(Relux)을 이용한 가로등 주택침입광 예측값과 실측값 비교)

  • Jung, Dae-Kwan;Park, Hyung-Kyu;Jung, Joon-Sig
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.1
    • /
    • pp.98-104
    • /
    • 2018
  • The assessment of the light trespass in terms of light pollution is difficult due to the complexity of light environments. As a result, the light pollution research has examined the influences of light pollution using simulation program such as RELUX. However, there still exists a differences between the real measurement value and the simulation value for the light trespass. In this paper, we analyzed the light trespass using the RELUX simulation program, and compared results with real measurement values. In this study, the regions (Seoul, Incheon, etc.) were investigated regarding the light trespass for outdoor lighting. The survey of vertical illuminance was analyzed measuring point (more than 2 point) out the window that was expected to light trespass for the higher anticipated to illumination. The illuminational predicted values for the RELUX program were compared with maximum one. As a result of this study, the illuminational errors between the measurement values and predicted values for the simulation were examined from -0.97 lx to 0.65 lx except 2.08 lx and -7.70 lx. The light trespass was analyzed the higher by how much the located close to the height, length, width of the outdoor lighting for the window. For measuring predicted values using RELUX, it was not sufficiently considered in the simulation conditions because of environmental factors and investigator error etc. Limitations of this study include the limited number of measurements, and greater field data is required in future studies.

A Study on the Sanitary Condition of Kitchens in Food Court/Cafeterias - An Observation on Seasonal Variations (휴게음식점 주방의 환경위생상태에 관한 조사연구 - 계절별 변화를 중심으로 -)

  • Kim, Jong-Gyu;Park, Jeong-Yeong;Kim, Joong-Soon
    • Journal of Environmental Health Sciences
    • /
    • v.38 no.2
    • /
    • pp.118-127
    • /
    • 2012
  • Objectives: This study was undertaken to assess the sanitary conditions in the kitchens of food court/cafeterias and determine seasonal variations. Methods: We measured environmental factors (air temperature, relative humidity, illumination intensity, noise level), and dropping airborne microbes (bacteria and fungi) in the kitchens of eight food court/cafeterias in four seasons (January, April, July, and October). Air temperature and relative humidity were measured with in/out thermo-hygrometers at 1.2-1.5 m above floor level. Illuminance measurement was performed through the multiple point method of Korean Standards (KS). Noise level was measured by the standard methods for the examination of environmental pollution (noise and vibration) of Korea. The estimation of dropping airborne bacteria and fungi was performed through use of Koch's method. Results: The highest kitchen air temperature was in July, and the lowest in January. The average temperature surpassed $21^{\circ}C$ throughout the seasons, suggesting a higher temperature than required for the safe handling of food. Humidity in all the kitchens was measured in the range of 50-60%. Half of the kitchens showed illumination intensities below 300 Lux in April. It was found that the sound pressure level of noise in almost all of the kitchens was higher than 85 dB (A). The highest levels of dropping airborne bacteria and fungi were noted in July. The numbers of airborne bacteria were higher than those of fungi. The levels of dropping airborne bacteria and fungi were affected by air temperature, relative humidity, season, and place. Conclusions: This study indicates that the kitchen environments were unqualified to supply safe food. The hygiene level of the kitchens should be improved.

Study on the Development of Large Capacity LED Streetlight Luminaire with adjustable Light Distribution Characteristic (배광특성 조절이 가능한 대용량 LED 가로등기구 개발에 관한 연구)

  • Lee, Wan-Bum
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.12
    • /
    • pp.8901-8907
    • /
    • 2015
  • Conventional streetlight with the not-adjustable light distribution characteristic is generating light pollution such as glare, damage to the crops and disturbed sleep, because beam of streetlight is not distributed evenly according to the surrounding areas and road conditions. In this paper, we proposed the new structure LED streetlight controlled light irradiation angle according to the surrounding areas and road conditions. Proposed LED streetlight are available to the adjustable light distribution characteristic using the half-circle angle control device. Result of measurement and simulation, beam angle is made available to control at least from $100^{\circ}$ up to $154^{\circ}$, average illumination exceeded 15% of KS regulation and overall uniformity exceeded more than 50% of KS regulation. the Developed large capacity LED streetlight luminaire is considered to minimize glare and light pollution and optimize uniformity ratio of illuminance.