• 제목/요약/키워드: Iliac fixation

검색결과 52건 처리시간 0.029초

자가 비골이식술을 이용한 족관절 유합술: 2예 보고 (Ankle Arthrodesis Using Auto Fibula Bone Graft: Two Cases Report)

  • 이창호;윤원식;오진록
    • 대한족부족관절학회지
    • /
    • 제15권2호
    • /
    • pp.102-106
    • /
    • 2011
  • Recently, development and improvement in joint replacement therapy, the need for arthrodesis has been decreasing. However, result of joint replacement is not always satisfactory, and most cases are rather indicative to ankle arthrodesis than ankle replacement. Often, ankle arthrodesis can be more beneficial salvage method to treat cases with failure in joint replacement therapy, talar avascular necrosis with massive bone defect, talus fracture with severe comminution and bone defect and ankle dislocation. In cases with large bone defect that need to be treated with ankle arthrodesis using internal fixation, it is difficult to fill the defect with conventional auto-iliac bone or all-bone graft. Thus, we make a report on our experience in treating 2 cases with ankle arthrodesis using auto-fibular bone graft and plate fixation.

하악골의 불연속 결손부 재건 시 비혈행화 장골이식술의 골흡수율에 관한 연구 (Evaluation of Bone Resorption Rate after Nonvascularized Iliac Bone Graft for Mandibular Discontinuity Defect)

  • 최진욱;이충오;황희돈;김진욱;권대근;김진수;이상한
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제34권6호
    • /
    • pp.398-403
    • /
    • 2012
  • Purpose: Mandible resection and discontinuity defect created lead to aesthetic and functional problems. The iliac crest bone graft exhibits relative ease for bone harvesting, possibility of two team approach, ability to close the wound primarily, large amount of corticocancellous bone and relatively few complications. Whereas the use of free vascularized flaps has donor site morbidity and worse-fitting bone contour, the use of nonvascularized iliac bone graft has advantages in the operation time and patients' recovery time. So, nonvascularized iliac bone graft could be an attractive option. Methods: Twenty-one patients (M:F=1:1.1) underwent iliac crest bone harvesting for reconstruction of mandibular discontinuity defect (mean length : $61.6{\pm}17.8$ mm), from May 2005 to October 2011 at the Department of Oral and Maxillofacial Surgery in Kyungpook National University. The average age was $44.1{\pm}16.4$ years and the mean follow up periods was $28.2{\pm}22.7$ months. Bone resorption rate, according to age, sex, primary lesion, location and distance of defect, type of fixation plate, time of graft and pre-operative radiation therapy, were measured in each patient. Results: The mean bone resorption rate was $16.1{\pm}9.0%$. Bone resorption rate was significantly increased in mandibular defect that is over 6 cm in size (P=0.015, P<0.05) and the cases treated pre-operative radiation therapy (P=0.017, P<0.05). All was successfully fixed and maintained for the long-term follow-up. There were a few donor site complications and almost all patients were shown favorable outcome without severe bone resorption in this study. Conclusion: The nonvascularized iliac bone graft seems to be a reasonably reliable treatment option for reconstruction of mandibular discontinuity defects.

제 1, 2 경추간 판하철사고정술 없는 후방 경관절 나사못 고정술 및 골유합술 (Posterior C1-2 Transarticular Screw Fixation without C1-2 Sublaminar Wiring in Atlantoaxial Instability)

  • 신용환;황정현;성주경;황성규;함인석;박연묵;김승래
    • Journal of Korean Neurosurgical Society
    • /
    • 제29권11호
    • /
    • pp.1469-1475
    • /
    • 2000
  • Objective : The goal of this study was to evaluate the clinical outcome of the posterior C1-2 transarticular screw fixation without C1-2 sublaminar wiring in atlantoaxial instability. Methods : Between Apr. 1995 and Feb. 2000, we used this technique in treat randomly selected 17 patients (11 men, 6 women) who had atlantoaxial instability. The causes of instability were : type II-A odontoid process fracture(10 cases) ; type II-P odontoid process fracture(1 case) ; Os odontoideum(2 cases) ; transverse ligament laxity due to rheumatoid disease(1 case) ; and, transverse ligament injury without bone fracture(3 cases). All cases were operated with posterior C1-2 transarticular screw fixation with 3.5mm cortical screw and interlaminar iliac graft without sublaminar wire fixation. The mean follow-up period was 28 months(5 to 58 months) and the mean age at the time of operation was 41 years(15 to 68 years). All Patients were allowed to ambulate with Philadelphia neck collar on the first post-operation day. Results : Bony fusion was successfully achieved in all cases demonstrated at 3-month follow-up studies. There was no operative mortality or morbidity. Conclusion : The authors conclude that the posterior transarticular screw fixation without C1-2 sublaminar wiring provide adequate stability with high bony union rate in atlantoaxial instability of various causes.

  • PDF

개의 전배측 고관절 탈구에서 변형된 외골격 고정 적용 5례 (Modified External Skeletal Fixation for Craniodorsal Coxofemoral Luxation in 5 Dogs)

  • 정창수;임지혜;변예은;김완희;윤정희;권오경
    • 한국임상수의학회지
    • /
    • 제24권4호
    • /
    • pp.631-635
    • /
    • 2007
  • Luxation of the hip is the most common luxation seen in small animals. Luxations are classified by the direction in which the femoral head lies in relation to the acetabulum and craniodorsal luxations are the most common type. Recommendations for treatment are based on the presence of preexisting disease, the type and duration of luxation and severity of concurrent injuries. In this study modified external skeletal fixation was used for craniodorsal coxofemoral luxation in 5 dogs. Luxated head Joint was reduced and fixator pins were applied into the greater trochanter, the middle point of iliac body and the lateral surface of sacroiliac joint in a closed fashion. Reduction was successful in 4 of the 5 operated limbs. Complications noted in this study included pin tract drainage, pin loosening and secondary fracture at the pin insertion site.

축추-환추간 경관절 나사못 고정술 치료의 결과 및 합병증 (The Results and Complications of the C1-C2 Transarticular Screw Fixation Methods)

  • 최준웅;윤승환;박형천;박현선;김은영;하윤
    • Journal of Korean Neurosurgical Society
    • /
    • 제37권3호
    • /
    • pp.201-206
    • /
    • 2005
  • Objective: To evaluate the accuracy and safety of C1-C2 transarticular screw insertion, we retrospectively review surgical records and postoperative radiological findings. Methods: From January 2001 to October 2003, the C1-C2 transarticular screw fixation and posterior wiring with iliac bone grafts was performed in 16 patients. 6 patients had rheumatoid arthritis which caused cervical instability, 3 patients had os odontoideum, 3 patients had type 2 odontoid process fracture, 3 patients had traumatic transverse ligament injury and 1 patients who had been managed with C1-C2 wire fixation had psoriatic arthritis. Results: Osseous fusion was documented in 15 patients(93.8%). Only one patient was recorded screw loosening because of postoperative infection. One patient had only one screw placed because of abnormal anatomical structure, one patients was breakage of a Kirschner wire, and one screw was medial location to lateral mass of C1, but clinical results was excellent and radiological instability was not noted. Conclusion: The author's experience demonstrates that C1-C2 transarticular screw fixation with wired bone graft is a safe procedure with higher fusion rate but precaution is needed to avoid the neural damage, vertebral artery injury, and hardware failure.

상완골 간부 불유합에 대한 금속판 고정 및 자가골 이식술 (Compression Plate Fixation with Autogenous Bone Graft for Humerus Shaft Nonunion)

  • 조철현;송광순;배기철;김인규;권두현
    • Clinics in Shoulder and Elbow
    • /
    • 제12권1호
    • /
    • pp.33-37
    • /
    • 2009
  • 목적: 상완골 간부 골절의 불유합에 대해 그 원인을 분석하고, 금속판 고정 및 자가골 이식술을 통한 수술적 치료의 결과를 평가하고자 하였다. 대상 및 방법: 총 18예를 대상으로 하였으며, 평균 추시 기간은 28개월이었다. 불유합에 대해 금속판 고정 및 자가골 이식술을 시행하였고, 골결손이 심한 경우 골단축술을 병행하였다. 술후 추시 단순 방사선 검사로 골유합을 확인하였고, ASES 점수 평가법을 이용하여 임상적 평가를 시행하였다. 결과: 불유합의 원인은 처음 수술시 금속판을 시행한 12예의 경우에서는 불충분한 금속판 길이가 6예, 금속판의 파손 2예, 나사못의 이완이나 파손이 2예, 감염이 1예, 정신과적 문제로 인한 환자의 불응성이 1예였고, 금속정 고정술을 시행한 3예에서는 전 예에서 골절 부위의 신연이 원인이었으며, 외고정을 시행한 3예에서는 불충분한 고정이 원인이었다. 전 예에서 골유합을 얻을 수 있었으며, 골유합까지의 기간은 평균 24주였다. 임상적 결과는 우수가 11예, 양호가 6예, 보통이 1예였다. 결론: 불유합에 대한 수술 시 불유합 부위에 존재하는 섬유조직이나 괴사된 골조직을 철저하게 제거한 후, 충분한 길이의 금속판 내고정술 및 자가골 이식술을 이용하면 만족스러운 결과를 얻을 수 있을 것으로 사료된다.

Clavicle Nonunion: Matchstick Bone-grafting and Osteosynthesis

  • Park, Yong Bok;Yoo, Jae Chul;Park, Geun Min;Kum, Dong Ho;Tauheed, Mohammed;Jeong, Jeung Yeol
    • Clinics in Shoulder and Elbow
    • /
    • 제19권1호
    • /
    • pp.33-38
    • /
    • 2016
  • Background: This study was conducted to evaluate the surgical outcomes of plate fixation using autologous iliac bone graft shaped in the form of a matchstick in clavicle nonunion resulting from prior surgical or non-surgical management. Methods: From May 2005 to February 2013, 17 patients underwent surgery for clavicle nonunion. The mean age at the time of surgery was 48.8 years. The iliac bone was harvested and shaped into slivers approximately 3 cm long, which resembled matchsticks. After opening of the medullary canal, the plate and screws were applied and cancellous bone was placed at the nonunion site. Matchstick bone grafts which were longitudinally placed and encircled on the nonunion site were tied with periosteum using 3-4 stitches. Union was determined via postoperative plane X-ray. Clinical status was evaluated using the visual analogue scale score for pain, and Constant and American Shoulder Elbow Surgeon score. Results: All patients had a stable radiological union at the follow-up. The mean duration from index operation to nonunion operation was 13.2 months (7-32 months). The mean follow-up period was 20.1 months (8-56 months), and the mean duration until union was 11.2 weeks (8-16 weeks). All clinical scores were improved at the final follow-up (p<0.001). The mean segmental defect was $3.3{\pm}2.6mm$ (1-18 mm); and the difference in clavicular length between operative and non-operative site was $5.9{\pm}6.9mm$. Conclusions: Matchstick shaped autologous iliac bone grafting technique in clavicle nonunion is acceptable with a high union rate.

Strut Support with Tricortical Iliac Allografts in Unstable Proximal Humerus Fractures: Surgical Indication and New Definition of Poor Medial Column Support

  • Lee, Seung-Jin;Hyun, Yoon-Suk;Baek, Seung-Ha
    • Clinics in Shoulder and Elbow
    • /
    • 제22권1호
    • /
    • pp.29-36
    • /
    • 2019
  • Background: The execution of fibular allograft augmentation in unstable proximal humerus fractures (PHFs) was technically demanding. In this study, the authors evaluated the clinical and radiographic outcomes after tricortical iliac allograft (TIA) augmentation in PHFs. Methods: We retrospectively assessed 38 PHF patients treated with locking-plate fixation and TIA augmentation. Insertion of a TIA was indicated when an unstable PHF showed a large cavitary defect and poor medial column support after open reduction, regardless of the presence of medial cortical comminution in preoperative images. Radiographic imaging parameters (humeral head height, HHH; humeral neck-shaft angle, HNSA; head mediolateral offset, HMLO; and status of the union), Constant score, and range of motion were evaluated. Patients were grouped according to whether the medial column support after open reduction was poor or not (groups A and B, respectively); clinical outcomes were compared for all parameters. Results: All fractures healed radiologically (average duration to complete union, 5.8 months). At final evaluation, the average Constant score was 73 points and the mean active forward flexion was $148^{\circ}$. Based on the Paavolainen assessment method, 33 patients had good results and 5 patients showed fair results. The mean loss of reduction was 1.32 mm in HHH and 5.02% in HMLO. None of the parameters evaluated showed a statistically significant difference between the two groups (poor and not poor medial column support). Conclusions: In unstable PHFs, TIA augmentation can provide good clinical and radiological results when there are poor medial column support and a large cavitary defect after open reduction.

절단부위에 따른 수무지 재건의 기능적 평가 (Functional Evaluation of Thumb Reconstruction according to the Level of Amputation)

  • 이광석;박종웅;서동훈;정웅교
    • Archives of Reconstructive Microsurgery
    • /
    • 제7권2호
    • /
    • pp.135-145
    • /
    • 1998
  • In 1980 Morrison and O'Brien reported their experiences about the reconstruction of amputated thumb using wrap-around neurovascular free flap from the great toe with a nonvascularized iliac bone graft. From then it has been considered to be a good reconstructive procedure for the amputated thumb, but it's indication has been limited distal to the metacarpophalangeal(MP) joint. We have performed 37 cases of wrap-around free flap from the great toe for the reconstruction of thumb amputated at distal or proximal to the MP joint and investigated their functional results according to the level of amputation. Level of amputation was distal to the MP joint in 25 cases and proximal to it in 12 cases. Pinching and grasping power, two point discrimination and the amount of opposition to the other fingers were compared to the uninjured hand. Pinching and grasping power were not significantly different according to the level of amputation but the amount of two point discrimination was significantly high in the cases amputated proximal to the MP joint. The opposition of reconstructed thumb to the other fingers was completely possible in all cases amputated distal to the MP joint. In 12 cases amputated proximal to the MP joint of the thumb, opposition was completely possible in 6 cases in which the iliac bone block was fixated in the position of $30^{\circ}$ flexion and $45^{\circ}$ internal rotation but in 6 cases in the fixation of $30^{\circ}$ flexion and $30^{\circ}$ internal rotation, the opposition of reconstructed thumb to the ring and little fingers were impossible in 5 cases and only to the little finger in 1 case. In this study, we concluded that even if amputation proximal to the MP joint, it is no more contraindication of the wrap-around free flap procedure for thumb reconstruction, however in these cases we recommend iliac bone block fixation in the position of $30^{\circ}$ flexion and $45^{\circ}$ infernal rotation for the better functional outcome.

  • PDF

하악골 부분절제술후 이물성형재료에 의한 즉시재건술이 실패된 예에서 양측 장골뼈와 Miniplate Osteosynthesis 를 이용하여 재건시킨 법랑아세포종 치험 1예 (LATE RECONSTRUCTION OF PARTIALLY-RESECTED MANDIBLE AFTER REMOVAL OF AMELOBLASTOMA OF THE MANDIBLE)

  • 박형식;김선용;권준호;이상휘
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제12권1호
    • /
    • pp.171-179
    • /
    • 1990
  • This is a report on a case of delayed reconstruction after partial mandibularectomy for Ameloblastoma involving symphysis and bodies of the mandible by using of two large pieces of corticocancellous bone blocks obtained from both iliac crests. The authors failed immediate reconstruction with two kinds of Alloplasts(metal, methylmethacrylate) at two times of trial due to known infection and suggestive poor histocompatibility of materials aginst the host who has been suffered from long-term and active pulmonary tuberculosis. However we could get success late reconstruction of this problem-occured and curved area with two pieces of large corticocancellous blocks by using of miniplate osteosynthesis and biphasic external pin fixation. From our experience we are obtained some results as follows : 1. Alloplastic graft materials seemed to be dangerous to maintain successfuly in patient who has a long-term debilitating disease as a active pulmonary tuberculosis. 2. Biphasic external skeletal pin fixation appliance gave many advantages such as maintain functional position of the remained bodies and condyles of the mandible after removal of failed alloplasts and during control of inflammation of this area, assist supportive roles to fix and maintain bone grafts during healing, allow mandibular movement during healing and so offer to conduct normal functional stimuli to bone grafts during osteogenesis etc. 3. Bony union was successful between not only normal bones and grafted bones but also grafted bone pieces even though we used two pieces of large blocks of corticocancellous bone for graft. 4. Miniplate osteosynthesis was not affect any adverse effects to bone grafts but offered good role of fixation and maintenance for bone grafts.

  • PDF