• Title/Summary/Keyword: Identify contamination

Search Result 234, Processing Time 0.028 seconds

The Effects of Bed-rock Formations on Water Quality and Contamination : Statistical Approaches (수자원의 수질과 오염에 대한 기반암의 영향 연구 : 통계학적 접근)

  • 이병선;우남칠
    • Economic and Environmental Geology
    • /
    • v.36 no.6
    • /
    • pp.415-429
    • /
    • 2003
  • This study was objected to identify the difference of water quality and the characteristics of water contamination in adjacent bed-rock areas of Upper Hwajeonni and Guryongsan Formations in Miwon, Choongchungbuk-do, Korea. Water samples showed mainly (Ca, Mg)-$HCO_3$ type in Upper Hawjeonni Formation and (Ca, Mg)-$SO_4$ and (Ca, Mg)-$HCO_3$ types in Guryongsan Formation indicating the enrichment of $SO_4$ in major compositions. Groundwater quality could be divided into two groups based on the major weathering processes, implied by the ratio of bicarbonate to silica. Carbonate-silicate weathering predominates in Upper Hwajeonni Formation, and silicate weathering in Guryongsan Formation. Stream-water quality also appeared to be controlled by water-rock interaction. Cluster analysis identified three groups of groundwater and four groups of stream-water with distinctive geochemical characteristics. The results of factor analysis indicated that the levels of each chemical constituent in water samples derived from both natural weathering reactions and anthropogenic contamination sources. To delineate the pollution potential of water resources, Modified Pollution Index(M.P.I.) was developed. M.P.I. scores of water samples ranged from -0.08 to 0.18, with mostly positive along the rock quarry in Guryongsan Formation areas. M.P.I. scores appeared to be a useful predictor of metal contamination of water resources.

Current Status and Technologies for Treating Groundwater Arsenic Pollution in Bangladesh (방글라데시 지하수 내 비소 오염 현황 및 처리기술)

  • Tashdedul, Haque Md;Reyes, Nash Jett DG.;Jeon, Minsu;Kim, Lee-Hyung
    • Journal of Wetlands Research
    • /
    • v.24 no.2
    • /
    • pp.142-154
    • /
    • 2022
  • Arsenic (As) contamination in groundwater is one of the main problems in Bangladesh. As toxicity causes serious human health problems such as edema, skin cancer, bladder cancer, lung cancer, hyperkeratosis, premature birth, and black foot disease. As contamination in groundwater mainly originates from the geological characteristics of the area due to the influence of anthropogenic activities. Since most of the people in Bangladesh rely on tube well for drinking water, it is necessary to investigate the current status of As pollution and identify the treatment technologies that can be used to provide arsenic-free drinking water in water-scarce areas. A total of 92 papers were reviewed in this study to present a complete overview of the recent status of groundwater As contamination in Bangladesh and different low-cost remediation technologies. A method for evaluating the relative feasibility of different treatment technologies was also utilized to determine the most appropriate technologies for groundwater As treatment in Bangladesh. The districts with the highest groundwater As contamination include Brahamanbariya, Tangail, Barisal, Pabna, Patuakhali, Kurigram, Magura, and Faridpur, with concentrations exceeding 0.05 mg/L. Only six districts had relatively low groundwater arsenic concentrations (0.01 mg/L), including Kushtia, Khagrachari, Jessore, Dinajpur, Meherpur, and Munshiganj. There were a number of technologies used for treating As in water, but aerated electrocoagulation, Mg-Fe-based hydrotalcite-like compound, and electro-chemical As remediation (ECAR) reactor were found to be the most feasible treatment methods for As. Overall, the investment, operational, and maintenance costs, availability of materials, and expertise requirements should be considered when selecting the most appropriate treatment method for As in water.

A Correlation Study on Surface Contamination of Semiconductor Packaging Au Wire by Components of Rinse (반도체 패키지용 Au Wire의 표면처리용 린스 성분에 따른 표면오염 비교 연구)

  • Ha-Yeong Kim;Yeon-Ryong Chu;Jisu Lim;Gyu-Sik Park;Jiwon Kim;Dahee Kang;Yoon-Ho Ra;Suk Jekal;Chang-Min Yoon
    • Journal of Adhesion and Interface
    • /
    • v.25 no.2
    • /
    • pp.63-68
    • /
    • 2024
  • In this study, the contamination of gold(Au) wire according to the types of rinse applied for surface treatment in the wire bonding process is investigated and confirmed. For the surface treatment, rinses containing silicon(Si) or those based on organic materials are mainly employed. To identify their effects, surface treatment is conducted on Au wire using two types of rinse at a 1.0 wt% concentration, referred to as Si-including and Oil-based rinse-coated Au wire. Subsequently, a simulation experiment is performed to verify the reactivity of dust containing Si components that could occur in the semiconductor process. Through optical microscopy (OM) and scanning electron microscopy(SEM) analysis, it is observed that a larger amount of dust is adsorbed on the surface of Si-including rinse-coated Au wire compared with the Oil-based rinse-coated Au wire. This is attributed that the rinse containing Si components is relatively polar, causing polar interactions with dust, which also has polarity. Therefore, it is expected that using a rinse without Si components can reduce contamination caused by dust, thereby decreasing the defect rate in the practical wire bonding process.

Design of Gas Identification System with Hierarchical Rule base using Genetic Algorithms and Rough Sets (유전 알고리즘과 러프 집합을 이용한 계층적 식별 규칙을 갖는 가스 식별 시스템의 설계)

  • Bang, Yonug-Keun;Byun, Hyung-Gi;Lee, Chul-Heui
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.8
    • /
    • pp.1164-1171
    • /
    • 2012
  • Recently, machine olfactory systems as an artificial substitute of the human olfactory system are being studied actively because they can scent dangerous gases and identify the type of gases in contamination areas instead of the human. In this paper, we present an effective design method for the gas identification system. Even though dimensionality reduction is the very important part, in pattern analysis, We handled effectively the dimensionality reduction by grouping the sensors of which the measured patterns are similar each other, where genetic algorithms were used for combination optimization. To identify the gas type, we constructed the hierarchical rule base with two frames by using rough set theory. The first frame is to accept measurement characteristics of each sensor and the other one is to reflect the identification patterns of each group. Thus, the proposed methods was able to accomplish effectively dimensionality reduction as well as accurate gas identification. In simulation, we demonstrated the effectiveness of the proposed methods by identifying five types of gases.

Studies on Fungal Contamination and Mycotoxins of Rice Straw Round Bale Silage (사료용 볏짚 곤포사일리지의 곰팡이 및 Mycotoxin 오염 연구)

  • Sung, Ha-Guyn;Lee, Joung-Kyong;Seo, Sung
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.31 no.4
    • /
    • pp.451-462
    • /
    • 2011
  • The purpose of this study was to investigate fungi and mycotoxin contamination of the rice straw bale silage in Korean. It was tested the 33 samples of rice straw round bale silage with various condition which fed cattle in the farm. The level of fungal contamination was $2.1{\times}10^6\;cfu\;g^{-1}$ in the average and $9.2{\times}10^8\;cfu\;g^{-1}$ in the maximum. The fungal contamination was detected in the all of normal samples which good condition of rice straw bale silage. When the fungi was isolate and identify, it was found 28 species and mycotoxin producing fungi were 8 species as following as Aspergillus flavus, Aspergillus fumigatus, Fusarium culmorum, Fusarium verticillioides, Penicillium carneum, Penicillium paneum, Penicillium roqueforti, Penicillium viridicatum. Specially, Penicillium paneum was found 42% of samples and Aspergillus sp. (A. flavus, A. fumigatus) are 21% of samples. In case of mycotoxin contamination, the 42% of samples are detected more than one kind of mycotoxin. Some samples are contaminated three kinds of mycotoxin. This study was not found aflatoxin ($B_1$, $B_2$, $G_1$, $G_2$) and fumonisin ($B_1$, $B_2$), but were detected the contamination of ochratoxin A (1.0~5.8 ug/kg), deoxynivalenol (DON, 156.0~776.7 ug/kg) and zearalenone (ZON, 38.0~750.0 ug/kg). Therefore, the above results show that rice straw round bale silage expose on hazard factors as mycotoxigenic fungi and mycotoxin contamination, and than need more research about mycotoxin in animal feed to protect animal and human healthy.

Source identification and Pathway analysis of Nitrate contamintation in "Cultural village", Jeungpyeong

  • 전성천;이강근;배광옥;정형재
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2002.04a
    • /
    • pp.254-257
    • /
    • 2002
  • The purposes of this research are to identify the source and to analyze the pathway of nitrate contamination in "cultural village", Jeungpyeong. In order to examine recharge processes and flow pattern that closely related to the influent of nitrate contaminant, the flow field was simulated and the oxygen and hydrogen stable isotopes were analyzed. The nitrogen isotope was used to delineate contaminant sources. The shallow groundwater was mainly composed of precipitation, but leakage of domestic water and sewage contributed to the recharge. Nitrate contaminants were possibly from the leakage of sewage and animal waste. The nitrate concentration decreased due to dilution by low concentration water.ion water.

  • PDF

Enhanced least square complex frequency method for operational modal analysis of noisy data

  • Akrami, V.;Zamani, S. Majid
    • Earthquakes and Structures
    • /
    • v.15 no.3
    • /
    • pp.263-273
    • /
    • 2018
  • Operational modal analysis is being widely used in aerospace, mechanical and civil engineering. Common research fields include optimal design and rehabilitation under dynamic loads, structural health monitoring, modification and control of dynamic response and analytical model updating. In many practical cases, influence of noise contamination in the recorded data makes it difficult to identify the modal parameters accurately. In this paper, an improved frequency domain method called Enhanced Least Square Complex Frequency (eLSCF) is developed to extract modal parameters from noisy recorded data. The proposed method makes the use of pre-defined approximate mode shape vectors to refine the cross-power spectral density matrix and extract fundamental frequency for the mode of interest. The efficiency of the proposed method is illustrated using an example five story shear frame loaded by random excitation and different noise signals.

Analysis of Salt Contamination in the domestic coast area (국내 해안지역의 오손특성 분석)

  • Kim, Dong-Myung;Kim, Byung-Sook;Lee, Nam-Woo;Choi, Sun-Kyu
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.504-505
    • /
    • 2006
  • We installed the measurement equipment which measure the equivalent Salt Deposit Density(ESDD) of the domestic coast area in the selected 112 place and investigated the influence of the wind which blow at the point of 500m from coast installing a wind vane, wind gauge for realtime measurement. During september${\sim}$december, 2005, ESDD which passively measured at the point of 50m from coast is maximum C grade in the Homigot of Pohang, B grade in the Gochang and A grade in the remaining point. Also ESDD which is measured in the east coast, west coast respectively is the more the distance being far from the coast to inland, the more ESDD rapidly decreasing but each area of the south coast is difficult to identify the decreased tendency because of very low measurements.

  • PDF

경기도 일죽 지역 천부 지하수질의 연간 변화

  • 김연태;정성욱;현승규;신우식;우남칠
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.09a
    • /
    • pp.489-492
    • /
    • 2003
  • This study is objected to identify the annual variation of shallow groundwater quality in the study area, Hwabong-Jangam, Iljuk-Meon, Kyunggi-Do. The previous study in 2002 shown a wide-spread contamination of shallow groundwater by nitrate mainly originated from wastes of livestock facilities. In the year 2003, groundwater quality of the area has worsened due to the agricultural activities including the application of organic fertilizer and agro-chemicals to improve soil quality. In addition, a leaking septic tank, identified in the previous study, is still expanding its influence on the nearby wells.

  • PDF

Mycoflora in Broiler Houses (Broiler양계사내(養鷄舍內)의 진균총(眞菌叢))

  • Choi, Won-pil;Yeo, Sang-geon;Lee, Hun-jun
    • Korean Journal of Veterinary Research
    • /
    • v.24 no.1
    • /
    • pp.36-39
    • /
    • 1984
  • The present survey was undertaken to determine the mycoflora of broiler houses. Attempts were made to isolate and identify fungi in the dust, feed, litter and water from 21 broiler houses. A total of 166 isolates of fungi was identified as yeast spp. (44%), Aspergillus spp. (30.7%), Verticillium spp. (7.2%), Penicillium spp. (3.6%), Paecilomyces spp. (3.6%), Scopulariopsis spp. (3.0%), Cephalosporium spp. (3.0%), Chrysosporium spp. (2.4%), Cladosporium spp. (1.8%) and Absidia spp. (0.6%). Isolated of Aspergillus(A) spp. and Penicillium(P) spp. were identified as A. fumigatus, A. flavus, A. terreus, A. nidulans, A. niger, P. citrinum and P. palitan. Fungal contamination of the broiler houses predominated in the dust. The important point is that must of the isolates were pathogenic fungi.

  • PDF