• Title/Summary/Keyword: Identical image

Search Result 200, Processing Time 0.026 seconds

Correlation analysis of periodontal tissue dimensions in the esthetic zone using a non-invasive digital method

  • Kim, Yun-Jeong;Park, Ji-Man;Cho, Hyun-Jae;Ku, Young
    • Journal of Periodontal and Implant Science
    • /
    • v.51 no.2
    • /
    • pp.88-99
    • /
    • 2021
  • Purpose: Direct intraoral scanning and superimposing methods have recently been applied to measure the dimensions of periodontal tissues. The aim of this study was to analyze various correlations between labial gingival thickness and underlying alveolar bone thickness, as well as clinical parameters among 3 tooth types (central incisors, lateral incisors, and canines) using a digital method. Methods: In 20 periodontally healthy subjects, cone-beam computed tomography images and intraoral scanned files were obtained. Measurements of labial alveolar bone and gingival thickness at the central incisors, lateral incisors, and canines were performed at points 0-5 mm from the alveolar crest on the superimposed images. Clinical parameters including the crown width/crown length ratio, keratinized gingival width, gingival scallop, and transparency of the periodontal probe through the gingival sulcus were examined. Results: Gingival thickness at the alveolar crest level was positively correlated with the thickness of the alveolar bone plate (P<0.05). The central incisors revealed a strong correlation between labial alveolar bone thickness at 1 and 2 mm, respectively, inferior to the alveolar crest and the thickness of the gingiva at the alveolar crest line (G0), whereas G0 and labial bone thickness at every level were positively correlated in the lateral incisors and canines. No significant correlations were found between clinical parameters and hard or soft tissue thickness. Conclusions: Gingival thickness at the alveolar crest level revealed a positive correlation with labial alveolar bone thickness, although this correlation at identical depth levels was not significant. Gingival thickness, at or under the alveolar crest level, was not associated with the clinical parameters of the gingival features, such as the crown form, gingival scallop, or keratinized gingival width.

A Study on Design Characteristics of Chanel's and Fendi's Collections under the Direction of Karl Lagerfeld (칼 라거펠트 디렉팅의 샤넬과 펜디에 대한 디자인 특성 연구)

  • Bae, Woo Ri;Kim, Yoon Kyoung;Lee, Kyoung Hee
    • Fashion & Textile Research Journal
    • /
    • v.23 no.6
    • /
    • pp.709-725
    • /
    • 2021
  • The study focused on the design features of Chanel and Fendi, directed by Carl Lagerfeld, creative director of Chanel and Fendi until his recent death. The range of the study was from the 2017 S/S Collection to the 2019 F/W Collection, which collected a total of 767 fashion photographs, including 483 Chanel, 284 Fendi, with tops, bottoms and dresses at VOGUE (https://www.vogue.com). According to the data analysis criteria organized based on prior research and related literature, it was classified in the order of form, color, material, pattern, decoration, fashion image, item and coordination, and content analysis was conducted based on statistical analysis. Overall, the design characteristics of the Chanel collection, directed by Karl Lagerfeld, were rectangle form, tone in tone coloring, combination of identical materials, geometric patterns, and classical images as the main design characteristics of the Chanel collection. The design characteristics shown in the Fendi collection directed by Karl Lagerfeld were rectangle form, tone in tone coloration, hard material combination, abstract pattern, and total coordination. Comparing the design features of Chanel and Fendi, directed by Karl Lagerfeld, is as follows. Chanel and Fendi's designs show a lot of rectangle form, tone-in-tone colors, hard-materials and combination of the same material.

Comparison of Shallow Model Tunnel Test Using Image Processing and Numerical Analysis (이미지 프로세싱을 이용한 얕은 터널 모형실험과 수치해석의 비교)

  • Lee, Yong-Joo
    • Journal of the Korean Geotechnical Society
    • /
    • v.22 no.7
    • /
    • pp.5-12
    • /
    • 2006
  • In this study, 2D shallow tunnel model test using close range photogrammetric technique was conducted with aluminium rods simulating continuum granular material. Numerical analysis was also carried out in order to identify the behaviour of subsurface deformations caused by shallow tunnelling. Direction and magnitude of displacement vectors from the model test were identical to the result of numerical analysis based on the model data. In particular, it is shown that the vector direction was toward a point below the tunnel invert level. A narrow "chimney or tulip like" pattern of vertical displacement was confirmed by both the model test and numerical analysis. This behaviour is consistent with the field data. In addition to the qualitative comparison, the quantitative result of subsurface settlements according to 2D volume loss showed good agreement between the model test and numerical analysis. Therefore, close range photogrammetric technique applied in the model test may be used to validate the result from the continuum numerical analysis.

Dosimetric Evaluation of Synthetic Computed Tomography Technique on Position Variation of Air Cavity in Magnetic Resonance-Guided Radiotherapy

  • Hyeongmin Jin;Hyun Joon An;Eui Kyu Chie;Jong Min Park;Jung-in Kim
    • Progress in Medical Physics
    • /
    • v.33 no.4
    • /
    • pp.142-149
    • /
    • 2022
  • Purpose: This study seeks to compare the dosimetric parameters of the bulk electron density (ED) approach and synthetic computed tomography (CT) image in terms of position variation of the air cavity in magnetic resonance-guided radiotherapy (MRgRT) for patients with pancreatic cancer. Methods: This study included nine patients that previously received MRgRT and their simulation CT and magnetic resonance (MR) images were collected. Air cavities were manually delineated on simulation CT and MR images in the treatment planning system for each patient. The synthetic CT images were generated using the deep learning model trained in a prior study. Two more plans with identical beam parameters were recalculated with ED maps that were either manually overridden by the cavities or derived from the synthetic CT. Dose calculation accuracy was explored in terms of dose-volume histogram parameters and gamma analysis. Results: The D95% averages were 48.80 Gy, 48.50 Gy, and 48.23 Gy for the original, manually assigned, and synthetic CT-based dose distributions, respectively. The greatest deviation was observed for one patient, whose D95% to synthetic CT was 1.84 Gy higher than the original plan. Conclusions: The variation of the air cavity position in the gastrointestinal area affects the treatment dose calculation. Synthetic CT-based ED modification would be a significant option for shortening the time-consuming process and improving MRgRT treatment accuracy.

Development of an FPGA-based Sealer Coating Inspection Vision System for Automotive Glass Assembly Automation Equipment (자동차 글라스 조립 자동화설비를 위한 FPGA기반 실러 도포검사 비전시스템 개발)

  • Ju-Young Kim;Jae-Ryul Park
    • Journal of Sensor Science and Technology
    • /
    • v.32 no.5
    • /
    • pp.320-327
    • /
    • 2023
  • In this study, an FPGA-based sealer inspection system was developed to inspect the sealer applied to install vehicle glass on a car body. The sealer is a liquid or paste-like material that promotes adhesion such as sealing and waterproofing for mounting and assembling vehicle parts to a car body. The system installed in the existing vehicle design parts line does not detect the sealer in the glass rotation section and takes a long time to process. This study developed a line laser camera sensor and an FPGA vision signal processing module to solve this problem. The line laser camera sensor was developed such that the resolution and speed of the camera for data acquisition could be modified according to the irradiation angle of the laser. Furthermore, it was developed considering the mountability of the entire system to prevent interference with the sealer ejection machine. In addition, a vision signal processing module was developed using the Zynq-7020 FPGA chip to improve the processing speed of the algorithm that converted the profile to the sealer shape image acquired from a 2D camera and calculated the width and height of the sealer using the converted profile. The performance of the developed sealer application inspection system was verified by establishing an experimental environment identical to that of an actual automobile production line. The experimental results confirmed the performance of the sealer application inspection at a level that satisfied the requirements of automotive field standards.

Development of Geometrical Quality Control Real-time Analysis Program using an Electronic Portal Imaging (전자포탈영상을 이용한 기하학적 정도관리 실시간 분석 프로그램의 개발)

  • Lee, Sang-Rok;Jung, Kyung-Yong;Jang, Min-Sun;Lee, Byung-Gu;Kwon, Young-Ho
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.2
    • /
    • pp.77-84
    • /
    • 2012
  • Purpose: To develop a geometrical quality control real-time analysis program using an electronic portal imaging to replace film evaluation method. Materials and Methods: A geometrical quality control item was established with the Eclipse treatment planning system (Version 8.1, Varian, USA) after the Electronic Portal Imaging Device (EPID) took care of the problems occurring from the fixed substructure of the linear accelerator (CL-iX, Varian, USA). Electronic portal image (single exposure before plan) was created at the treatment room's 4DTC (Version 10.2, Varian, USA) and a beam was irradiated in accordance with each item. The gaining the entire electronic portal imaging at the Off-line review and was evaluated by a self-developed geometrical quality control real-time analysis program. As for evaluation methods, the intra-fraction error was analyzed by executing 5 times in a row under identical conditions and procedures on the same day, and in order to confirm the infer-fraction error, it was executed for 10 days under identical conditions of all procedures and was compared with the film evaluation method using an Iso-align$^{TM}$ quality control device. Measurement and analysis time was measured by sorting the time into from the device setup to data achievement and the time amount after the time until the completion of analysis and the convenience of the users and execution processes were compared. Results: The intra-fraction error values for each average 0.1, 0.2, 0.3, 0.2 mm at light-radiation field coincidence, collimator rotation axis, couch rotation axis and gantry rotation axis. By checking the infer-fraction error through 10 days of continuous quality control, the error values obtained were average 1.7, 1.4, 0.7, 1.1 mm for each item. Also, the measurement times were average 36 minutes, 15 minutes for the film evaluation method and electronic portal imaging system, and the analysis times were average 30 minutes, 22 minutes. Conclusion: When conducting a geometrical quality control using an electronic portal imaging, it was found that it is efficient as a quality control tool. It not only reduces costs through not using films, but also reduces the measurement and analysis time which enhances user convenience and can improve the execution process by leaving out film developing procedures etc. Also, images done with evaluation from the self-developed geometrical quality control real-time analysis program, data processing is capable which supports the storage of information.

  • PDF

A Construction of the Multistep Optimal Three-Dimensional Finite Elements for the Mandible Structure Analysis (하악 구조체 분석을 위한 다단계 최적 3 차원 유한 요소 형성)

  • Lee, Hyeong-U;;Lee, Seong-Hwan;Kim, Chang-Heon;Kim, Tae-Yun
    • The Transactions of the Korea Information Processing Society
    • /
    • v.3 no.7
    • /
    • pp.1906-1916
    • /
    • 1996
  • For the medical analysis of the three-dimensional structure such as the mandible, it is necessary to reconstruct the structure into the finite number of analyzable elements. The information of the three-dimensional structure can be obtained from the cross-sections of the magnetic resonance image (MRI). A region corresponding to the structure is extracted from the inner part of the cross- section. By the triangulation of the sampled cross-section image, two-dimensional finite elements are generated. Three-dimensional finite elements are constructed by matching the two dimensional finite elements each other in space. In this paper a construction method of the optimal three-dimensional finite elements has been suggested, which uses the adjacent information abstracted from the triangulated two-dimensional finite elements. The elements are classified into the identical property sets by using the adjacent information of the traingulated two-dimensional elements. After applying the multistep matching algorithm to the classified two-dimensional finite elements, the optimal three-dimensional finite elements can be construccted. By analyzing the constructed finite elements, it is possible to get much more useful medical information about the three-dimensional struture of mandible.

  • PDF

Breeding of Fragrant Yellow Phalaenopsis and Scent Pattern Analysis by GC/SAW Electronic Nose System (유향성 황색계 호접란 육성 및 전자코를 이용한 향기패턴 분석)

  • Been, Chul-Gu
    • Horticultural Science & Technology
    • /
    • v.28 no.4
    • /
    • pp.656-663
    • /
    • 2010
  • In order to improve the consumer acceptance of fragrant yellow hybrids of $Phalaenopsis$ ($Phal.$), crosses between yellow hybrid varieties were made and the obtained hybrids were investigated for horticultural characteristics as well as difference in fragrance patterns. Cross combination of $Phal.$ Brother lawrence and $Phal.$ Brother saragold yielded good seedling population of 500 plants. Segregation was noticed in color density, spot and stripe patterns on yellow color base of petal and also in fragrance. Six lines with multi-branch on flower stalk and strong fragrance flower were finally selected. Volatile fragrance components were compared among $Phal.$ Brother lawrence, $Phal.$ Brother saragold and their hybrids by GC/SAW electronic nose. In the derivative pattern of chromatogram and polar derivative pattern of fragrance, similar dominant peaks appeared on retention time 7-9 s and some hybrid lines had two strong peaks on retention time 20-25 s, respectively. Also in polar frequency pattern of fragrance obtained by $VaporPrint^{TM}$ image analysis among parent flowers and hybrids, an identical strong peak near 8 s of retention time was shown. This single fragrance component is considered a key element of fragrance in $Phal.$ Brother lawrence, $Phal.$ Brother saragold and their hybrids. This peak could be used as a marker for the breeding of fragrance in $Phalaenopsis$.

Explicating Personal Health Informatics Experience (퍼스널 헬스케어 디바이스 사용자 경험 연구)

  • Shin, Dong-Hee;Cho, Hoyoun
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.1
    • /
    • pp.550-566
    • /
    • 2017
  • Recent advances in wearable devices and quantified-self movement increase the number of personal informatics application that may cause an concern to health industry and user. In this light, the goal of this study is to identify more effective ways of design and evaluation of personal informatics application for self-tracking and delivering health information to users. For this goal, this study conducted areal-world study that processes such that user can assess, be aware of, and self-reflect on their data and behavior activity. In doing so, this study aims to determine the psychological effects of forms of health feedback (comparative vs. non-comparative) and presentation modes (text vs. image) on users' tendencies toward health conservation. Results from a between-subjects experiment revealed that health information in a comparative and textual format was more effective in encouraging health conservation in participants than identical information presented in a non-comparative and image format. In addition, participants' level of health consciousness emerged as a significant predictor. Through this analysis of quantitative data and inferences, this study make a number of contributions to the user affordance research and its methodology of health informatics study and designing personal informatics application that support user's behavior change in various contexts.

Reverse-time migration using the Poynting vector (포인팅 벡터를 이용한 역시간 구조보정)

  • Yoon, Kwang-Jin;Marfurt, Kurt J.
    • Geophysics and Geophysical Exploration
    • /
    • v.9 no.1
    • /
    • pp.102-107
    • /
    • 2006
  • Recently, rapid developments in computer hardware have enabled reverse-time migration to be applied to various production imaging problems. As a wave-equation technique using the two-way wave equation, reverse-time migration can handle not only multi-path arrivals but also steep dips and overturned reflections. However, reverse-time migration causes unwanted artefacts, which arise from the two-way characteristics of the hyperbolic wave equation. Zero-lag cross correlation with diving waves, head waves and back-scattered waves result in spurious artefacts. These strong artefacts have the common feature that the correlating forward and backward wavefields propagate in almost the opposite direction to each other at each correlation point. This is because the ray paths of the forward and backward wavefields are almost identical. In this paper, we present several tactics to avoid artefacts in shot-domain reverse-time migration. Simple muting of a shot gather before migration, or wavefront migration which performs correlation only within a time window following first arriving travel times, are useful in suppressing artefacts. Calculating the wave propagation direction from the Poynting vector gives rise to a new imaging condition, which can eliminate strong artefacts and can produce common image gathers in the reflection angle domain.