• Title/Summary/Keyword: Id-1

Search Result 1,043, Processing Time 0.034 seconds

The Biometric based Mobile ID and Its Application to Electronic Voting

  • Yun, Sung-Hyun;Lim, Heui-Seok
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.7 no.1
    • /
    • pp.166-183
    • /
    • 2013
  • It requires a lot of costs and manpower to manage an election. The electronic voting scheme can make the election system economic and trustful. The widespread use of smart phones causes mobile voting to be a major issue. The smart phone can be used as a mobile voting platform since it can carry out many services in addition to basic telephone service. To make mobile voting practical and trustful, we analyzed two subjects of study. Firstly, the way to make a biometric based mobile ID, which has legal binding forces. In mobile voting, user identification is accomplished on line since the voter should be able to vote wherever they go. The digital ID conducts a similar role to the need for a resident card. The user's identity is bound to the resident card legally. To bind the user's identity to the smart phone, we use USIM. Biometric recognition is also needed to authenticate the user, since the user cannot prove him or her on line face-to-face. The proposed mobile ID can be reissued by means of introducing a random secret value. Secondly, the mobile voting scheme is proposed where candidates can accept election results without doubt. The goal of an election is to select a leader among two or more candidates. Existing electronic voting schemes mainly focus on the study of ballot verification accomplished by voters. These approaches are not safe against collusion attacks where candidates and the election administration center are able to collude to fabricate election results. Therefore, a new type of voting and counting method is needed where candidates can directly take part in voting and counting stages. The biometric based multi-signature scheme is used to make the undeniable multi-signed ballot. The ballot cannot be verified without the help of all candidates. If candidates accept election results without a doubt, the fairness of the election is satisfied.

A Study dn Identity-Based Cryptosystems (ID를 이용한 암호시스템에 관한 고찰)

  • 권창영;김경신;원동호
    • Review of KIISC
    • /
    • v.4 no.1
    • /
    • pp.20-29
    • /
    • 1994
  • Shamir가1984년 개인정보(ID)를 이용한 암호시스템의 개념을 제안한 이래 Fiat-Shamir방식을 필두로 하여 Ohta, Guillou 등이 개인정보에 기반을 둔 서명법과 영지식 대화형 증명방식을 조합한 각종 개인식별 방식 및 디지탈 서명 방식들이 제안되어 왔다. 또한, Okamoto 등이 개인 정보를 이용한 키분배 방식을 제안하였다. 본고에서는 지금까지 제안된 개인정보를 이용한 암호시스템의 대표적인 방식들에 대해 그들의 특징과 장단점을 비교 분석하였다.

  • PDF

Design of Detection system against Security Tool Evasion Attack using a VDS(Vulnerability diagnostication Script) (취약점 진단 스크립트를 이용한 보안도구 우회공격 탐지 시스템 설계)

  • 박명호;육상조;이극
    • Proceedings of the Korea Multimedia Society Conference
    • /
    • 2003.11a
    • /
    • pp.1-4
    • /
    • 2003
  • 최근에 침입 탐지 시스템은 네트워크 보안의 강화를 위해서 방화벽과 침입탐지 시스템 상호간의 연동으로 침입자의 연결 상태를 차단하는 방법도 개발되었다. 하지만 방화벽뿐만 아니라 침입탐지 시스템도 공격자에 의한 우회공격에 대해서는 아직 상당부분 방어할 수 없다. 또한 우회공격 탐지 모듈도 기존의 IDS와 Rule의 중복이 불가피하다. 본 논문은 취약점 진단 스크립트를 통해 IDS의 취약점 진단 후 IDS우회탐지공격 시스템의 Rule을 최적화 하여 우회공격을 효율적으로 탐지 해내는 시스템을 제안한다.

  • PDF

Clean mobile robot for wafer transfer (Wafer 낱장 반송용 이동 로봇의 개발)

  • 성학경;이성현;김성권
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.161-161
    • /
    • 2000
  • The clean mobile robot for wafer transfer is AGV that carry each wafer to each equipment. It has wafer handling technology, wafer ID recognition technology, position calibration technology using vision system, and anti-vibration technology. Wafer loading/unloading working accuracy is within ${\pm}$1mm, ${\pm}$3$^{\circ}$. By application of this AGV, we can reduce the manufacturing tack time and bring cost down of equipment.

  • PDF

Coordinated Load-Balancing in Chord System (Chord 시스템에서의 협력을 통한 로드 밸런싱 기법)

  • 강영상;염헌영
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2003.04d
    • /
    • pp.289-291
    • /
    • 2003
  • Peer-to-Peer Network에서의 object위치 정보의 배치 및 라우팅 방법인 Chord시스템은 node ID와 object ID생성에 있어서 SHA-1과 같은 해쉬 함수를 사용한다. Chord object위치 정보 관리에 있어서 해쉬에 의해 저절로 load-balancing을 기대하나 실험에 의하면 노드별 load에는 상당한 편차가 있음이 나타난다. 그러므로 이 논문에서는 각 node간 협력을 통하여 보다 효과적인 load-balancing을 제공하는 CLCS 기법을 제안한다.

  • PDF

A Study on the Synthesis and Its Biodistribution of C-11 and F-18 Labelled Choline (C-11 및 F-18 표지 콜린의 합성과 체내동태에 관한 연구)

  • Yang, Seung-Dae;Kim, Sang-Wook;Suh, Yong-Sup;Chun, Kwon-Soo;Ahn, Soon-Hyuk;Hur, Min-Goo;Lim, Sang-Moo;Hong, Sung-Woon;Yu, Kook-Hyun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.3
    • /
    • pp.185-191
    • /
    • 2001
  • Objectives: Recently, $[methyl-^{11}C]-({\beta}$-Hydroxyethyl)trimethylammonium ($[^{11}C]$choline) Has been discovered to be a very effective tracer in imaging various human tumors using positron omission tomography. Because of the short half-life of C-11, it is very difficult to use in a routine imaging procedure and needs a frequent synthesis of $[^{11}C]$choline. This can be supplemented by the substitution of $[^{11}C]$choline with $[methyl-^{18}F]$fluorocholine. Here, we would like to report ceil uptake and biodistribution of $[^{11}C]$choline and $[^{18}F]$fluorocholine as a basic study. Methods: $[^{11}C]$Choline was prepared by the treatment of $[^{11}C]CH_3I$ with N,N-dimethylaminoethanol and $[^{18}F]$fluorocholine was synthesized from reaction of $CH_2Br[^{18}F]F$ with N,N-dimethylaminoethanol. The radiochemical purity was checked by high performance liquid chromatography (HPLC). The blodistribution of $[^{11}C]$choline and $[^{18}F]$fluorocholine was determined in balb/c mouse at 5 min, 20 min, 40 min and 80 min. The cell uptake was measured using glioma (9L) and colon adenocarcinoma (SW620). Results: The radiochemical purity was more than 98% after purification. In the liver, uptake did not change over time; the uptake was 20%ID/g for $[^{11}C]$choline and 13%ID/g for $[^{18}F]$fluorocholine. In the kidney, radioactivity decreased over time; the uptake was 15%ID/g for $[^{11}C]$choline and 20%ID/g for $[^{18}F]$fluorocholine, 80 min post-injection. The cell uptake of $[^{11}C]$choline was 4.93% for glioma (9L) and 18.69% for colon adenocarcinoma (SW620). For $[^{18}F]$fluorocholine, 1.77% for glioma (9L) and 2.77% for colon adenocarcinoma (SW620). Conclusion: $[^{11}C]$Choline and $[^{18}F]$fluorocholine showed a different cell uptake tendency, depending on cancer cell line.

  • PDF

An Anti-Collision Algorithm with 4-Slot in RFID Systems (RFID 시스템에서 4 슬롯을 이용한 충돌방지 알고리즘)

  • Kim, Yong-Hwan;Kim, Sung-Soo;Ryoo, Myung-Chun;Park, Joon-Ho;Chung, Kyung-Ho
    • Journal of the Korea Society of Computer and Information
    • /
    • v.19 no.12
    • /
    • pp.111-121
    • /
    • 2014
  • In this paper, we propose tree-based hybrid query tree architecture utilizing time slot. 4-Bit Pattern Slot Allocation(4-SL) has a 8-ary tree structure and when tag ID responses according to query of the reader, it applies a digital coding method, the Manchester code, in order to extract the location and the number of collided bits. Also, this algorithm can recognize multiple Tags by single query using 4 fixed time slots. The architecture allows the reader to identify 8 tags at the same time by responding 4 time slots utilizing the first bit($[prefix+1]^{th}$, F ${\in}$ {'0' or '1'}) and bit pattern from second ~ third bits($[prefix+2]^{th}{\sim}[prefix+3]^{th}$, $B_2{\in}$ {"00" or "11"}, $B_1{\in}$ {"01" or "10"}) in tag ID. we analyze worst case of the number of query nodes(prefix) in algorithm to extract delay time for recognizing multiple tags. The identification delay time of the proposed algorithm was based on the number of query-responses and query bits, and was calculated by each algorithm.

A Multicenter Survey on the Current Status of Pediatric Blood Cultures in Korea (소아 대상 혈액배양검사 현황 파악을 위한 국내 다기관 설문조사)

  • Lee, Young Joon;Lee, Ji Young;Kong, Seom Kim;Yeon, Gyu Min;Hong, Yoo Rha;Oh, Chi Eun
    • Pediatric Infection and Vaccine
    • /
    • v.25 no.1
    • /
    • pp.17-25
    • /
    • 2018
  • Purpose: Blood culture is an essential diagnostic tool and requires clear indications, proper techniques, and quality control. We aimed to investigate whether blood cultures in children are appropriate for indications, are performed correctly, and receive proper quality control. Methods: We conducted an online survey targeting pediatric infectious diseases (ID) specialists working in general hospitals and neonatologists (Neo) working at hospitals operating a neonatal intensive care unit in Korea. Results: Approximately 81.1% (30/37) of pediatric ID specialists and 72.2% (52/72) of Neo responded to the survey. Some of the respondents (33.3% of ID and 59.6% of Neo) performed blood culture as a regular test irrespective of the indication. Approximately 40% of ID and 65.4% of Neo ordered only one set of blood culture in patients suspected with bacteremia. The most commonly used disinfectant for skin preparation was povidone-iodine, while the skin preparation method varied by institution. Approximately two-thirds of the institutions were monitoring the blood culture contamination rate, whereas relatively few provided staff with feedback on that rate. In addition, less than half of the institutions were providing regular staff training on blood culture (40% of ID and 28.8% of Neo). Conclusions: The indication and methods of blood culture for children varied according to institution, and few hospitals exert effort in improving the quality of blood culture. Institutions have to strive constantly toward improvement of blood culture quality and evidence-based recommendations for pediatric blood cultures should be standardized.

Absolute Renal $^{99m}Tc-DMSA$ Uptake and Renal Scan in Children with Vesicoureteral Reflux (방광요관역류를 가진 소아의 DMSA 스캔과 절대 신섭취율의 평가)

  • Bae, Sang-Kyun;Lee, Dong-Soo;Yang, Hyung-In;Choi, Chang-Woon;Chung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon;Choi, Yong;Kim, Gwang-Myung;Choi, Hwang;Yeon, Kyung-Mo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.26 no.2
    • /
    • pp.327-332
    • /
    • 1992
  • $^{99m}Tc-dimercaptosuccinic$ acid (DMSA) 주사후 일정시간에 측정한 절대적 신섭취량은 기능이 살아있는 신피질량과 관계있다. 소아의 신기능은 출생후 계속 성숙되어 생후 약 $1\sim2$년에 성인의 기능에 도달하는데 DMSA섭취도 성인과는 다른 양상을 보일 것으로 기대되며 신질환에서 절대적 신섭취율의 평가는 연령을 고려해야 할 것이다. 저자들은 DMSA 스캔을 시행한 소아 환자를 대상으로 스캔상 피질 결손이 없으며 양측신의 섭취율이 비슷하고 혈중 크레아티닌치가 정상인 경우를 대조군으로 하여 연령별 DMSA의 절대적 신섭취율을 구하였고 방광요관역류를 가진 환아를 대상으로 DMSA스캔을 시행하고 신섭취율을 조사하였다. 1) 대조군은 모두 65명으로 좌우측 신섭취율의 유의한 차이는 없었으며 연령에 따라 2세경에 플라토에 도달하였는데 한쪽 신장의 평균섭취율은 3개월 미만이 $14.5{\pm}3.1%$ ID, 3개월에서 6개월 미만이 $17.2{\pm}2.1%$ID, 6개월에서 1년 미만이 $18.4{\pm}1.3%$ID, 1년에서 1년6개월 미만이 $19.3{\pm}1.1%$ID, 1년 6개월에서 2년 미만이 $21.9{\pm}2.0%$ID, 2세이상 15세이하가 $20.1{\pm}0.6%$ID였으며 전체 평균섭취율은 $19.4{\pm}0.5%$ID (injected dose, $mean{\pm}S.E.$)였다. 2) 방광요관역류를 가진 환아는 55명 (일측성 56명, 양측성 29명)으로 109신장을 대상으로 하였다. 방광요관역류의 정도와 피질결손의 수와는 대체로 비례관계가 있었으나 방광요관역류가 없으면서 피질결손이 있는 경우가 25신장중 2예 (8%)였으며, 방광요관역류가 있는 84신장중 27예 (32.1%), 이중에서 방광요관역류가 3도 이상인 62신장중 13예 (21%)에서는 피질결손이 없었다. 3) 이환신의 DMSA 섭취율을 연령에 따른 대조군의 섭취율에 대한 비(섭취율비)로 나타내면 한쪽에 역류가 있을 때 이환신의 경우 $0.55{\pm}0.06$, 정상신의 경우 $1.34{\pm}0.05$이었으며, 양쪽에 역류가 있을 때는 평균 $0.82{\pm}0.08$ $(mean{\pm}S.E.)$ 이었다. 4) 피질결손이 있는 신장의 절대 DMSA 신섭취율은 감소되어 있었고 상대측 신장의 섭취율은 피질 결손이 있더라도 대상적인 증가의 경향을 보였다. 이상의 결과로 소아에서 DMSA 절대적 신섭취율의 연령에 따른 변화를 알 수 있었으며 방광요관역류의 정도와 피질결손의 정도가 반드시 비례하지만은 않아서 시간경과에 따른 추후 검사가 필요하리라 생각된다. 또한 방광요관역류가 있는 환아에서 DMSA 섭취율로 신기능을 평가할 때, 특히 영유아에서 연령에 따른 고려가 있어야 할 것으로 보인다.

  • PDF

SAW TECHNOLOGY 1

  • 황금찬
    • 전기의세계
    • /
    • v.30 no.3
    • /
    • pp.152-158
    • /
    • 1981
  • 본고의 내용은 다음과 같다. 1. SAW와 SAW의 전파 2. 여기 및 검출(ID transducer)

  • PDF