• 제목/요약/키워드: Ice Slurry Formation

검색결과 18건 처리시간 0.025초

가압 판형 열교환기에 의한 수용액의 아이스슬러리 생성 (Ice Slurry Formation of a Solution in a Pressurized Plate Heat Exchanger)

  • 이동규;김병선;백종현;홍희기;강채동
    • 설비공학논문집
    • /
    • 제18권7호
    • /
    • pp.596-602
    • /
    • 2006
  • Ice adhesion and blockage problems have been issued in continuous ice slurry making process. So we composed continuous ice slurry making device using a commercial small plate heat exchanger (PHX), and investigated character of ice formation. An experiment of ice formation was peformed with an aqueous solution of ethylene glycol 7 mass%. In the experiment, the effect of the pressurization on ice slurry formation during the cooling process was investigated. The pressurization test for the aqueous solution was performed by setting valves at the PHX inlet and outlet. At the results, the time of continuous ice formation increased as the pressure of the plate heat exchanger increased for cooling temperature of $-5^{\circ}C$. Also continuous ice formation at the cooling temperature of $-7^{\circ}C$ showed a possibility. It was found that the pressurization may contribute to suppress the dissolution of supercooled aqueous solution in the PHX.

판형 열교환기에서 유동 과냉도 및 냉각속도가 연속제빙에 미치는 영향 (Effect of supercooling and cooling rate on a continuous ice slurry formation using a plate heat exchanger)

  • 이동규;백종현;홍희기;강채동
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.138-143
    • /
    • 2006
  • The peculiarity of ice slurry, such as liquidity, high heat transfer rate and easy storage can also find to supercooled type dynamic ice storage system(DISS) which is one of the DISS. However, in order to accomplish continuous ice formation in the system without mechanical moving parts, supercooled aqueous solutionshould be formed stable through cooling heat exchanger and be dissoluted in storage tank. In previous research, the time of ice slurry increased as the pressure of the cooling heat exchanger(PHX) increased. In this study, a cooling experiment of an ethylene glycol 7mass% solution was performed with various inlet temperature of the PHX, which has constant brine inlet temperature of $-7^{\circ}C$. The temperature in the storage tank maintained to freezing point of the solution. At results, the time of ice slurry formation increased as the supercooling degree decreased and the cooling rate increased.

  • PDF

판형 열교환기를 이용한 과냉각수용액에서 유동과냉도 및 냉각속도가 연속제빙에 미치는 영향 (Influence of the Supercooling Degree and Cooling Rate on a Continuous Ice Formation by a Supercooled Aqueous Solution in Flow Using a Plate Heat Exchanger)

  • 이동규;백종현;홍희기;강채동
    • 설비공학논문집
    • /
    • 제19권9호
    • /
    • pp.647-653
    • /
    • 2007
  • In dynamic ice storage system(DISS), ice slurry is formed not only from solution freezing by mechanical removing parts but also supercooled solution. However, in order to perform continuous ice formation in the system without mechanical moving parts, supercooled aqueous solution should be formed stable through cooling heat exchanger and be dissolved uniformly in storage tank. In previous study, the time of ice slurry increased as the pressure of the cooling heat exchanger(PHX) increased. In this study, a cooling experiment of an ethylene glycol 7mass% solution was performed with various inlet temperature of the PHX, which has constant brine inlet temperature of $-7^{\circ}C$. The temperature in the storage tank maintained to freezing point of the solution. At results, the time of ice slurry formation increased as the supercooling degree decreased and the cooling rate increased.

수용액의 교반/냉각을 동반한 슬러리 얼음의 빙부착 (Adhesion of Ice Slurry in an Aqueous Solution Cooling with Stirring)

  • 강채동;손권;백종현;홍희기
    • 설비공학논문집
    • /
    • 제14권12호
    • /
    • pp.1071-1077
    • /
    • 2002
  • Ice adhesion on cooling wall is very important in continuous ice formation. The purpose of the present study is to investigate the possibilities of a three-component aqueous solution as a thermal storage material for the continuous ice formation. By freezing under stirring the solution of 300 mL in a stainless steel vessel which was immersed and cooled in a temperature controlled bath, an ice slurry was formed experimentally with measuring the temperature and stirring load variation. From the experiment, the ice adhesion was suppressed when the supercooling degree decreased and the concentration of aqueous solution increased.

냉각면 성상이 빙부착에 미치는 영향 (Effect on the Adhesion of Ice Slurry by the Characteristic of Cooling Surface)

  • 승현;홍희기;강채동
    • 설비공학논문집
    • /
    • 제17권2호
    • /
    • pp.183-190
    • /
    • 2005
  • In the process of ice-slurry making, ice adhesion on cooling wall or in narrow flow Path disturbs continuous ice formation. In this study, the effect on the ice adhesion to cooling surface by some freezing experiments was investigated, quantitatively. Three types of solutions were frozen in various coating vessels with stirring. In the experiment, the ice adhesion between cooling wall and Ice-slurry was evaluated by measuring stirring power. From the result, the stirring power of slurry mixture in PTFE-coating vessel was smaller than those in PE-coating, PFA-coating and bare SUS vessel. Especially, in EG H PG 1.S/ HD 1.5 mass$\%$ solution, the stirring power in the PE-coating vessel was smaller than that in the PFA-coating or SUS vessel.

역전 유동층 내의 유동해석 및 슬러리아이스 생성에 관한 연구 (Flow pattern analysis and a study on formation of slurry ice in the reversing flow)

  • 오철;최영규
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2011년도 전기공동학술대회 논문집
    • /
    • pp.202-202
    • /
    • 2011
  • Thermal energy storage(TES) cooling system using cheaper electricity of off-peak time has been applied to relief a significant portion of the peak demand of electricity during the daytime in summer. Slurry ice type thermal energy storage cooling system is one kind of more efficient ice-thermal energy storage cooling system than Ice-on-Coil type or Encapsulated type TES cooling system, even though, which are more popular TES system. This study is experimented to observe flow pattern and formation of slurry ice in reversing flow to improve efficiency of heat transfer between fluid and freezing tube.

  • PDF

다성분계 수용액의 교반/냉각에 의한 빙부착 (Adhesion of Ice Slurry in a Multi-component Aqueous Solution with Stirring and Cooling)

  • 강채동;강용태;홍희기
    • 설비공학논문집
    • /
    • 제14권12호
    • /
    • pp.1063-1070
    • /
    • 2002
  • To resist ice adhesion on cooling wall is concerned to continuous ice formation in thermal storage system. In this study, ice slurries were formed with two ecological aqueous solution, one is ethanol+silanol and the other is propylene glycol+silanol. By freezing under stirring the solution of $300m\ell$ in a stainless steel vessel which was immersed and cooled in a temperature controlled bath, the shape of ice slurry and the strength of ice adhesion on wall was observed with measuring the temperature and stirring load variation. As the concentration is smaller and the supercooling degree is larger, the ice adhesion is easy to occur. When the stirring load is larger than$ 2.1\times10^{-5}W$, the ice adhesion occurred.

역전 유동층에 의한 슬러리아이스 생성에 관한 연구 (A study on formation of slurry ice by the reversing flow)

  • 오철;문성배;최영규
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제30권3호
    • /
    • pp.376-381
    • /
    • 2006
  • This study is experimented to observe an influence of experimental conditions on production characteristics of slurry ice by putting ball into test section to disturb ice adhesion. And at this experiment it used ethylene glycol-water solution and the concentration is 20wt%. The experimental apparatus was constructed of ethylene glycol-water solution and slurry ice storage tank. brine tank, pumps for ethylene glycol-water solution and brine circulating, a mass flow-meter data logger for fluid temperature measuring and a vertical circular tube with two copper tubes as test section. The experiments were carried out under various conditions, with mean velocity of fluid at the entry ranging from 0.07 to 0.13m/s and ball diameter is 10mm, 15mm. Also ball filling rate is 33%, 50%.

역전 유동층 내에서의 슬러리아이스 생성에 관한 실험적 연구 (An experimental study on formation of slurry ice in reversing flow)

  • 최영규;윤석훈;오철
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2006년도 전기학술대회논문집
    • /
    • pp.49-50
    • /
    • 2006
  • This study experimented to observe an influence of experimental conditions on production characteristics of slurry ice by putting ball into test section to disturb ice adhesion. And at this experiment it used ethylene glycol-water solution and the concentration is 20wt%. The experimental apparatus was constructed of ethylene glycol-water solution and slurry ice storage tank, brine tank. pumps for ethylene glycol-water solution and brine circulating, a mass flow-meter, data logger for fluid temperature measuring and a vertical circular tube with two copper tubes as test section. The experiments were carried out under various conditions, with mean velocity of fluid at the entry ranging from 0.07 to 0.13m/s and ball diameter is 10mm, 15mm. Also ball filling rate is 33%, 50%.

  • PDF

역전 유동층을 이용한 관군 내에서의 슬러리아이스 생성에 관한 연구 (A Study on Formation of Slurry Ice by using the Reversing Flow in a Bundle of Tube)

  • 오철;최영규
    • 한국항해항만학회지
    • /
    • 제35권5호
    • /
    • pp.365-370
    • /
    • 2011
  • 최근 지구 온난화와 더불어 급격한 기후 변화 등으로 여름철 주간 냉방 수요가 급격히 증가하고 있다. 이에 따른 전력 수요량 또한 증가하고 있다. 이런 이유로 세계적으로 에너지 이용 효율 향상에 대한 관심이 높아지고 있고, 최근 국내 및 국외의 축냉시스템을 이용한 주간 전력 피크값을 최소화 하는 연구개발과 실제 적용 사례가 늘어나고 있다. 빙축열시스템의 경우 그 경제적 효과가 높아 그 관심이 높아지고 있는 추세이다. 축냉시스템은 주간 냉방에 사용하는 냉열을 야간에 만들어 탱크에 저장해 두었다가 그것을 낮에 이용함으로써, 갑작스런 부하 증가에 적절히 대응할 수 있는 등 여러 가지 장점을 갖고 있다. 본 실험에서는 슬러리아이스 생성을 위해 냉각표면에서 생성된 슬러리아이스를 분리시키기 위해 유체보다 밀도가 낮은 역전유동 물질을 삽입하여 역전 유동층을 형성하였으며, 역전유동층의 유동에 의해 관군으로 구성되어 있는 냉각튜브 표면에 빙부착이 심화되기 전에 얼음 입자를 분리시켜 수 내지 수십 미크론 단위의 슬러리아이스를 생성하도록 하였다.