• Title/Summary/Keyword: Ice Service

Search Result 77, Processing Time 0.022 seconds

Electrical signal characteristics of conductive asphalt concrete in the process of fatigue cracking

  • Yang, Qun;Li, Xu;Wang, Ping;Zhang, Hong-Wei
    • Smart Structures and Systems
    • /
    • v.14 no.3
    • /
    • pp.469-477
    • /
    • 2014
  • As a kind of intelligent materials, conductive asphalt concrete has a broad application prospect including melting ice and snow on the pavement, closing cracks in asphalt concrete, sensing pavement damage, and so on. Conductive pavement will be suffered from fatigue failure as conventional pavement in the process of service, and this fatigue damage of internal structure can be induced by electrical signal output. The characteristics of electrical signal variation of conductive asphalt concrete in the process of fatigue cracking were researched in this paper. The whole process was clearly divided into three stages according to resistance changes, and the development of fatigue damage wasn't obvious in stage I and stage II, while in stage III, the synchronicity between the resistance and damage began to appear. Thus, fatigue damage variable D and initial damage value $D_0$ represented by the functions of resistance were introduced in stage III. After calculating the initial damage value $D_0$ under different stress levels, it was concluded that the initial damage value $D_0$ had no noticeable change, just ranged between 0.24 and 0.25. This value represented a critical point which could be used to inform the repair time of early fatigue damage in the conductive asphalt pavement.

Instrumental Methods for Differentiation of Frozen-thawed from Fresh Broiler Breast Fillets

  • Jung, Samooel;Lee, Jae-Cheong;Jung, Yeon-Kuk;Kim, Min-Kyu;Son, Hwa-Young;Jo, Cheo-Run
    • Food Science of Animal Resources
    • /
    • v.31 no.1
    • /
    • pp.27-31
    • /
    • 2011
  • To differentiate between frozen-thawed and fresh broiler breast fillets, different methods such as optical microscopy and measurement of drip loss, pH, torrymeter and K-value were performed. A total of 10 samples of fresh and frozen-thawed breast fillets were stored in a refrigerator ($4^{\circ}C$) for 5 d. Optical microscopy of the frozen-thawed breast fillets found structural changes caused by ice crystals, which may have significantly increased drip loss compared to fresh breast fillet. The pH and K-value could not be distinguished between the two breast fillets during storage. However, the torrymeter values of the fresh and frozen-thawed breast fillets were significantly different (p<0.05). The results indicate that both optical microscopy and torrymeter measurement can be effective methods for differentiating between fresh and frozen-thawed breast fillets. However, optical microscopy may be difficult to implement in the marketplace since it requires much time and effort. Thus, the determination of the torrymeter value is the easiest and most rapid instrumental method among those tested for the differentiation of frozen-thawed chicken breast fillet from fresh one.

Measurement of Delivery Service Environment for Cold Chain EPS Packaging System of Fresh Food (신선식품 콜드체인 EPS 패키징 시스템의 택배 유통환경 계측)

  • KORAKOT, CHAROENSRI;Kim, SY;Shin, YJ;Jung, HM;Park, JM
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.28 no.1
    • /
    • pp.67-73
    • /
    • 2022
  • The food cold chain refers to a technology and distribution supply chain applied to maintain a constant temperature suitable for the product from production (harvest) to delivery to consumers. In particular, in Korea, the insulation material used in the food cold chain is mostly EPS (Expanded Polystyrene), which is used as a transport container for various food cold chains. However, according to the government's eco-friendly policy, companies charge environmental contributions to the use of EPS, but due to its low price and convenience of handling, it is still used as a container for delivering food. In this study, in order to measure the domestic delivery environment of general refrigerated foods, changes in impact, temperature, and humidity during transport of the EPS packaging system containing foods and ice pack refrigerants were measured. As a result, there were 2?3 sections in which a high impact force of 40 G or more was generated during transport. This can cause damage to the product and EPS container. The difference in temperature and humidity changes by parcel transport routes is more than 30%, so it is necessary to present accurate standards for the domestic cold chain distribution environment. As a result of microbial experiments. the transportation period had a dominant effect on the increase in total viable count and E. coli count.

A Exploratory Study on the Development of Star Menus in the Western Restaurants of the Hotels Focused on the Tourism Hotels in Seoul (호텔 양식당의 스타메뉴 개발에 관한 탐색적 연구 -서울지역 특1급 호텔을 중심으로-)

  • Lee, Eun-Jung;Lee, Jong-Kil
    • Journal of the Korean Society of Food Culture
    • /
    • v.21 no.6
    • /
    • pp.629-637
    • /
    • 2006
  • This exploratory study is to analyze the status of star menus and suggest the development strategy of star menus in the western restaurants of the tourism hotels in Seoul. The data was collected from the chefs who have been working over 15-years in tourism hotels in Seoul by judgement sampling. The questionnaire was composed of Miller and Pavesic's 'Fifty tips for a successful menu' and Khan's 'The evaluation of menu item development', The 30-menu items were selected from the 1st survey on the menu items that were high in both popularity and contribution margin by menu engineering method. The selected menu items were analyzed by 14 lists: simplicity, ready availability of ingredients, quality, flavor, presentation, preparation, service method, nutrition quality, preference, profitability, serving temperature, descriptive copy of menu and publicity. As a result of the study, appetizer category was recorded the highest score by 4.09. Smoked salmon, Tomato and mozzarella cheese, Cream of mushroom, Cream of asparagus, French onion soup, Grilled beef tenderloin, Grilled rib-eye steak, Roasted lamb rack, King prawn, Seafood spaghetti, Chef's salad, Caesar salad, Organic salad, Fruit plate, Italian tiramisu and Yogurt ice cream were recorded high score. The development strategy of star menu is belows : the menu writer must consider the productivity, effectiveness, popularity and profitability, the regular customers want varieties and creativity in the menu and the operators have to include the star menu items in the set menu.

Development and performance evaluation of traction system for steep gradient and sharp curve track (급구배 및 급곡선 궤도 추진시스템 개발 및 성능 평가)

  • Seo, Sungil;Mun, Hyung-Suk;Moon, Ji-Ho;Suk, Myung-Eun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.9
    • /
    • pp.493-501
    • /
    • 2016
  • In this study, core technologies of a traction system on a mountain tram operating on the track of mountain road full of sharp curves and steep gradients were developed. In domestic mountain resort areas, sometimes the transportation service is not provided in winter because of ice and heavy snow on roads, so a mountain railway service independent of the climate and geographic conditions is needed. A traction system was designed taking into account of the power of a traction motor to climb the gradient of 120 ‰, which is common in domestic mountainous areas. and power transmission system was designed to consider the installation space for the traction system. In addition, a reduction gear and a propeller shaft were developed. An elastic pinion was developed and applied to the rack & pinion bogie system for steep gradient so that noise and vibration generated by contact between the steel gears could be reduced. Impact comparison tests showed that the vibration level of the elastic pinion is one-third lower than that of previous steel pinion. Independent rotating wheels and axles were developed for the bogie system to operate on the sharp curve of a 10 meter radius. In addition, the band braking system was developed to enhance the braking force during running on the steep gradient. A test for the braking force showed it exerts the required braking force. The performance of the developed core components were verified by the tests and finally they were applied to the bogie system running on the track of steep gradient and sharp curve.

Recent Progress in Air Conditioning and Refrigeration Research -A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2000 and 2001- (공기조화, 냉동 분야의 최근 연구 동향 -2000년 및 2001년 학회지 논문에 대한 종합적 고찰 -)

  • 강신형;한화택;조금남;이승복;조형희;김민수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.12
    • /
    • pp.1102-1139
    • /
    • 2002
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering in 2000 and 2001 has been done. Focus has been put on current status of research in the aspect of heating, cooling, ventilation, sanitation and building environment. The conclusions are as follows. (1) Most of fundamental studies on fluid flow were related with heat transportation of facilities. Drop formation and rivulet flow on solid surfaces were interesting topics related with condensation augmentation. Research on micro environment considering flow, heat, humidity was also interesting for comfortable living environment. It can be extended considering biological aspects. Development of fans and blowers of high performance and low noise were continuing topics. Well developed CFD technologies were widely applied for developing facilities and their systems. (2) Most of papers related with heat transfer analysis and heat exchanger shows dealt with convection, evaporation, and channel flow for the design application of heat exchanger. The numerical heat transfer simulation studies have been peformed and reported to show heat transfer characteristics. Experimental as well as numerical studies on heat exchanger were reported, while not many papers are available for the system analysis including heat exchanger. (3) A review of the recent studies on heat pump system shows that performance analysis and control of heat pump have been peformed by various simulations and experiments. The research papers on multi-type heat pump system increased significantly. The studies on heat pipe have been examined experimently for change of working characteristics and strut lure. Research on the phase change has been carried out steadily and operation strategies of encapsulated ice storage tank are reported experimentally in several papers. (4) A review of recent studies on refrigeration/air conditioning system have focused on the system performance and efficiency for new alternative refrigerants. Evaporation and condensation heat transfer characteristics are investigated for tube shapes and new alternative refrigerants. Studies on components of refrigeration/air conditioning system are carried to examine efficiency for various compressors and performance of new expansion devices. In addition to thermophysical properties of refrigerant mixtures, studies on new refrigerants are also carried out, however research works on two-phase flow seemed to be insufficient. (5) A review of the recent studies on absorption cooling system indicates that heat and mass transfer phenomena have been investigated to improve absorber performance. Various experimental data have been presented and several simulation models have been proposed. A review of the recent studies on duct and ventilation shows that ventilation indices have been proposed to quantify the ventilation performance in buildings and tunnels. Main efforts have been focused on the applications of ventilation effectiveness in practice, either numerically using computational fluid dynamics or experimentally using tracer gas techniques. (6) Based on a review of recent studies on indoor thermal environment and building service systems, research issues have mainly focused on many innovative ideas such as underfloor air-conditioning system, personal environmental modules, radiant floor cooling and etc. Also, the new approaches for minimizing energy consumption as well as improving indoor environmental conditions through predictive control of HVAC systems, various activities of building energy management and cost-benefit analysis for economic evaluation were highlighted.

Recent Progress in Air Conditioning and Refrigeration Research - A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2002 and 2003 - (공기조화, 냉동 분야의 최근 연구 동향 -2002년 및 2003년 학회지 논문에 대한 종합적 고찰 -)

  • Chung Kwang-Seop;Kim Min Soo;Kim Yongchan;Park Kyoung Kuhn;Park Byung-Yoon;Cho Keumnam
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.12
    • /
    • pp.1234-1268
    • /
    • 2004
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering in 2002 and 2003 has been carried out. Focus has been put on current status of research in the aspect of heating, cooling, air-conditioning, ventilation, sanitation and building environment/design. The conclusions are as follows. (1) Most of fundamental studies on fluid flow were related with heat transportation in diverse facilities. Drop formation and rivulet flow on solid surfaces were interesting topics related with condensation augmentation. Research on micro environment considering flow, heat transfer, humidity was also interesting to promote comfortable living environment. It can be extended considering biological aspects. Development of fans and blowers of high performance and low noise were continuing research topics. Well developed CFD technologies were widely applied for analysis and design of various facilities and their systems. (2) Heat transfer characteristics of enhanced finned tube heat exchangers and heat sinks were extensively investigated. Experimental studies on the boiling heat transfer, vortex generators, fluidized bed heat exchangers, and frosting and defrosting characteristics were also conducted. In addition, the numerical simulations on various heat exchangers were performed and reported to show heat transfer characteristics and performance of the heat exchanger. (3) A review of the recent studies shows that the performance analysis of heat pump have been made by various simulations and experiments. Progresses have been made specifically on the multi-type heat pump systems and other heat pump systems in which exhaust energy is utilized. The performance characteristics of heat pipe have been studied numerically and experimentally, which proves the validity of the developed simulation programs. The effect of various factors on the heat pipe performance has also been examined. Studies of the ice storage system have been focused on the operational characteristics of the system and on the basics of thermal storage materials. Researches into the phase change have been carried out steadily. Several papers deal with the cycle analysis of a few thermodynamic systems which are very useful in the field of air-conditioning and refrigeration. (4) Recent studies on refrigeration and air-conditioning systems have focused on the system performance and efficiency enhancement when new alternative refrigerants are applied. Heat transfer characteristics during evaporation and condensation are investigated for several tube shapes and new alternative refrigerants including natural refrigerants. Efficiency of various compressors and performance of new expansion devices are also dealt with for better design of refrigeration/air conditioning system. In addition to the studies related with thermophysical properties of refrigerant mixtures, studies on new refrigerants are also carried out. It should be noted that the researches on two-phase flow are constantly carried out. (5) A review of the recent studies on absorption refrigeration system indicates that heat and mass transfer enhancement is the key factor in improving the system performance. Various experiments have been carried out and diverse simulation models have been presented. Study on the small scale absorption refrigeration system draws a new attention. Cooling tower was also the research object in the respect of enhancement its efficiency, and performance analysis and optimization was carried out. (6) Based on a review of recent studies on indoor thermal environment and building service systems, it is noticed that research issues have mainly focused on several innovative systems such as personal environmental modules, air-barrier type perimeterless system with UFAC, radiant floor cooling system, etc. New approaches are highlighted for improving indoor environmental conditions and minimizing energy consumption, various activities of building energy management and cost-benefit analysis for economic evaluation.

Evaluation of Crack Resistance of Cold Joint as Usage of Sealing Tape (실링 테이프 적용에 따른 시공조인트 균열 저항성 평가)

  • Lee, JaeJun;Lee, Seonhaeng;Kim, Du-Byung;Lee, Jinwook
    • International Journal of Highway Engineering
    • /
    • v.20 no.3
    • /
    • pp.1-9
    • /
    • 2018
  • PURPOSES : In order to evaluate a crack resistance at cold joint, sealing tape was adopted to apply at cold joint instead of typical tack coat material(RSC-4). The sealing tape was made by hot sealing material. The crack resistance as function of environmental and traffic loading was measured with visual observation. METHODS : In this study, the crack resistance was evaluated as function of environmental and traffic loading. The freeze-thaw method was adopted for environmental loading of asphalt pavement. condition. The damage of cold joint under freeze-thaw action is initiated by ice expansion load and accelerated by the interfacial damage between new and old asphalt pavement. The traffic loading was applied with wheel tracking machine on the cold joint area of the asphalt pavement for 3 hours at $25^{\circ}C$. The evaluation of crack resistance was measured with visual observation. The freeze-thaw results shows that the sealing tape was significantly increased the crack resistance based on. RESULTS : To estimate the crack resistance at cold joint area due to the environmental loading, the Freeze-thaw test was conducted by exposing the product to freezing temperature(approximately $-18^{\circ}C$) for 24 hours, and then allowing it to thaw at $60^{\circ}C$ for 24 hours. The tack coat material(RSC-4) was debonded after 21 cycles of the Freeze-thaw test. The first crack was observed after 14 freeze-thaw cycle with RSC-4 material. But, the sealing tape was not debonded after 24 cycle test. Also, the sealing tape shows the better performance of the crack resistance under the traffic loading with wheel track test. The crack was generated the under traffic loading with RSC-4(tack coating), however, the crack was not shown with sealing tape. It indicates that the sealing tape has a strong resistance of tensile stress due to traffic loading. CONCLUSIONS :Based on limited laboratory test result, a performance of crack resistance using the sealing tape is better than that of general tack coat material(RSC-4). It means that the sealing tape is possible to extend a pavement service life because the crack, one of the main pavement distresses, will be delayed.

A Strategic Quality Initiative and Its Opportunities to Improve Healthcare Environment (진료환경개선을 위한 우선적 전략과제 설정 및 그 적용)

  • Tark, Kwan-Chul;Park, Hyun-Ju;Park, Chang-Il;Kang, Jin-Kyung
    • Quality Improvement in Health Care
    • /
    • v.5 no.2
    • /
    • pp.324-334
    • /
    • 1998
  • Background : Strategic planning is an organizationwide or systemwide, ongoing look into the future usually of 2~3 years, based on objective analysis of the current environment and trends, but it can incorporate both short-term and long-term goals. The strategic planning process includes external analysis, internal analysis, issue analysis, development of mission, vision and values, and lastly development of organizational goals and objectives. As a part of the strategic quality planning process, certain service lines, important organizationwide functions, or key processes supporting these functions can be prioritized to expedite and roll out certain strategic goals. This is called strategic quality initiatives. Methods : We organized a quality improvement team, a subgroup of 21st century vision planning corps of our medical center, and pursued QI activities for improvement of healthcare environment, particularly in the admission setting. We developed a strategic quality initiative based on the results of patient satisfaction surveys, and carried out functions of self-directed work team. Results : The strategic goal was to be the benchmark for peer group hospitals in Korea for providing cost-effective best-practice. The QI team included 3 medical doctors, 1 nurse, 1 social worker, and 1 QI consultant as well as many operational members to support services and quality initiatives met every Tuesday for 18 weeks. Outcome objectives were to improve patient satisfaction score. The issues included in the objectives were comfort, temperature, noise, cleanliness of the admission wards, quality and education of patient meals, matters regarding the admission process, and an appurtenant facility such as restaurant or convenience store. Every issue was discussed and recommendations, conclusions and opportunities were implemented. Conclusions : By developing a strategic quality initiative as a part of the strategic quality planning process, and pursuing a self-directed work team, certain sen/ice lines, important organizationwide functions, or key processes supporting these functions can be improved effectively within a short period. Strategic quality initiatives serve to support, or roll out, certain strategic goals that are relevant to performance improvement and development of specific measurable outcome objectives, and associated performance measure for each initiative. Each strategic quality initiative should include a statement of intent outcome objectives, and performance measures. We will come back with follow up of the strategic quality initiative, for improvement of healthcare environment, and results of patient satisfaction re-survey.

  • PDF

A Study on the Optimization of District Heating and Cooling Facilities (지역냉난방사업의 설비 최적화에 관한 연구)

  • Kim, Jin Hyung;Choi, Byung Ryeal
    • Environmental and Resource Economics Review
    • /
    • v.15 no.3
    • /
    • pp.505-530
    • /
    • 2006
  • For the district heating and cooling business, it is required to install energy-saving facilities using energy from waste and land fill gases such as combined heat and power(CHP). The current issues that this business faces can be summarized as below: which facilities including CHP can be economically introduced and how much of their capacities should be. Most of such issues are clearly related to the optimal plant design of the district heating and cooling business, and the prices of energy services such as heating and cooling energy, and electricity. The purpose of this study is to establish linear program model of least cost function and to practice the empirical test on a assumed district heating and cooling business area. The model could choose the optimal type of energy-producing facilities among various kinds available such as CHP's, absorption chillers, the ice-storage system, etc. CHP with the flexible heat and power ratio is also in the set of available technologies. And the model show us the optimal ration of heat producing facilities between CHP and historical heat only boiler in the service area. Some implications of this study are summarized as below. Firms may utilize this model as a tool for the analysis of their optimal size of the facilities and operation. Also, the government may refer the results to regulate resonable size of business.

  • PDF