• Title/Summary/Keyword: IVR

Search Result 65, Processing Time 0.024 seconds

Design and Implementation of IVR Server Using VoiceXML (VoiceXML을 이용한 IVR 서버 설계 및 구현)

  • Lee, Chang-Ho;Jang, Won-Jo;Kang, Sun-Mee
    • Speech Sciences
    • /
    • v.9 no.3
    • /
    • pp.47-59
    • /
    • 2002
  • A new brilliant service using human-voice and DTMF (Dual Tone Multi Frequency) technique is expected nowadays in order to obtain valuable information on the internet more easily. VoiceXML (Voice eXtensible Markup Language) is the right choice that makes the new service possible. In this paper, the design and implementation of IVR (Interactive Voice Response) server using VoiceXML is described, where it connects with internet and IVR server efficiently. IVR server using VoiceXML is composed of two groups: VoiceXML document handling and VoiceXML execution. Scenario part of IVR server corresponds to VoiceXML document, the execution is performed by VoiceXML execution.

  • PDF

Impact of the Fidelity of Interactive Devices on the Sense of Presence During IVR-based Construction Safety Training

  • Luo, Yanfang;Seo, JoonOh;Abbas, Ali;Ahn, Seungjun
    • International conference on construction engineering and project management
    • /
    • 2020.12a
    • /
    • pp.137-145
    • /
    • 2020
  • Providing safety training to construction workers is essential to reduce safety accidents at the construction site. With the prosperity of visualization technologies, Immersive Virtual Reality (IVR) has been adopted for construction safety training by providing interactive learning experiences in a virtual environment. Previous research efforts on IVR-based training have found that the level of fidelity of interaction between real and virtual worlds is one of the important factors contributing to the sense of presence that would affect training performance. Various interactive devices that link activities between real and virtual worlds have been applied in IVR-based training, ranging from existing computer input devices (e.g., keyboard, mouse, joystick, etc.) to specially designed devices such as high-end VR simulators. However, the need for high-fidelity interactive devices may hinder the applicability of IVR-based training as they would be more expensive than IVR headsets. In this regard, this study aims to understand the impact of the level of fidelity of interactive devices in the sense of presence in a virtual environment and the training performance during IVR-based forklift safety training. We conducted a comparative study by recruiting sixty participants, splitting them into two groups, and then providing different interactive devices such as a keyboard for a low fidelity group and a steering wheel and pedals for a high-fidelity group. The results showed that there was no significant difference between the two groups in terms of the sense of presence and task performance. These results indicate that the use of low-fidelity interactive devices would be acceptable for IVR-based safety training as safety training focuses on delivering safety knowledge, and thus would be different from skill transferring training that may need more realistic interaction between real and virtual worlds.

  • PDF

A narrative review on immersive virtual reality in enhancing high school students' mathematics competence: From TPACK perspective

  • Idowu David Awoyemi;Feliza Marie S. Mercado;Jewoong Moon
    • The Mathematical Education
    • /
    • v.63 no.2
    • /
    • pp.295-318
    • /
    • 2024
  • This narrative review explores the transformative potential of immersive virtual reality (IVR) in enhancing high school students' mathematics competence, viewed through the lens of the technological, pedagogical, and content knowledge (TPACK) framework. This review comprehensively illustrates how IVR technologies have not only fostered a deeper understanding and engagement with mathematical concepts but have also enhanced the practical application of these skills. Through the careful examination of seminal papers, this study carefully explores the integration of IVR in high school mathematics education. It highlights significant contributions of IVR in improving students' computational proficiency, problem-solving skills, and spatial visualization abilities. These enhancements are crucial for developing a robust mathematical understanding and aptitude, positioning students for success in an increasingly technology-driven educational landscape. This review emphasizes the pivotal role of teachers in facilitating IVR-based learning experiences. It points to the necessity for comprehensive teacher training and professional development to fully harness the educational potential of IVR technologies. Equipping educators with the right tools and knowledge is essential for maximizing the effectiveness of this innovative teaching approach. The findings also indicate that while IVR holds promising prospects for enriching mathematics education, more research is needed to elaborate on instructional integration approaches that effectively overcome existing barriers. This includes technological limitations, access issues, and the need for curriculum adjustments to accommodate new teaching methods. In conclusion, this review calls for continued exploration into the effective use of IVR in educational settings, aiming to inform future practices and contribute to the evolving landscape of educational technology. The potential of IVR to transform educational experiences offers a compelling avenue for research and application in the field of mathematics education.

The Experience in Dose Measurement of IVR with Glass Dosimeter System

  • Nishizawa, Kanae;Moritake, Takashi;Iwai, Kazuo;Matsumaru, Yuji;Tsuboi, Koji;Maruyama, Takashi
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.269-271
    • /
    • 2002
  • It is reported that exposure for the patient and the medical staff from IVR is large. Direct measurement of patient exposure is difficult, since the measurement disturbs reading of images. The fluorescence glass-dosimeter system consisting of small-size glass chips is developed in recent years. Owing to its small size and physical characteristics, direct monitoring of surface dose may be feasible. The dose measurement for patient and medical staff during head interventional radiology (IVR) examinations was tried by using the fluorescence glass-dosimeter system. A dose response of the glass dosimeter is almost linear in large dose range but its energy dependency is high. About 20% variation of sensitivity was observed in the effective energy of 45-60keV which was used in IVR. In spite of this shortcoming, the fluorescence glass-dosimeter system is a convenient means for a dose monitoring during IVR performance.

  • PDF

A Systems Engineering Approach to Ex-Vessel Cooling Strategy for APR1400 under Extended Station Blackout Conditions

  • Saja Rababah;Aya Diab
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.19 no.2
    • /
    • pp.32-45
    • /
    • 2023
  • Implementing Severe Accident Management (SAM) strategies is crucial for enhancing a nuclear power plant's resilience and safety against severe accidents conditions represented in the analysis of Station Blackout (SBO) event. Among these critical approaches, the In-Vessel Retention (IVR) through External Reactor Vessel Cooling (IVR-ERVC) strategy plays a key role in preventing vessel failure. This work is designed to evaluate the efficacy of the IVR strategy for a high-power density reactor APR1400. The APR1400's plant is represented and simulated under steady-state and transient conditions for a station blackout (SBO) accident scenario using the computer code, ASYST. The APR1400's thermal-hydraulic response is analyzed to assess its performance as it progresses toward a severe accident scenario during an extended SBO. The effectiveness of emergency operating procedures (EOPs) and severe accident management guidelines (SAMGs) are systematically examined to assess their ability to mitigate the accident. A group of associated key phenomena selected based on Phenomenon Identification and Ranking Tables (PIRT) and uncertain parameters are identified accordingly and then propagated within DAKOTA Uncertainty Quantification (UQ) framework until a statistically representative sample is obtained and hence determine the uncertainty bands of key system parameters. The Systems Engineering methodology is applied to direct the progression of work, ensuring systematic and efficient execution.

Establishment of Quality Control System for Angiographic Unit (IVR장치의 성능 평가 기준 개발)

  • Kang, Byung-Sam;Son, Jin-Hyun;Kim, Seung-Chul
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.1
    • /
    • pp.236-244
    • /
    • 2011
  • Recently, the number of interventional procedures has increased dramatically as an alternative of invasive surgical procedure. The need for the quality control program of the angiographic units has also increased, because of concerns about the increased patient dose and the importance of image quality of angiographic units for the successful procedures. The purpose of this study was to propose an optimal guideline for the quality control program of the angiographic units. We reviewed domestic and international standards about medical imaging system and we evaluated the quality of 61 angiographic units in Korea with the use of NEMA 21 phantom. According to the results of our study, we propose a guideline for the quality control program of the angiographic units. Quality control program includes tube voltage test, tube current test, HVL test, image-field geometry test, spatial resolution test, low-contrast iodine detectability test, wire resolution test, phantom entrance dose test. Proposed reference levels are as follows: PAE < $\pm$ 10% in tube voltage test, PAE < $\pm$ 15% in tube current test, minimum 2.3 mmAl at 80 kVp in HVL test, minimum 'acceptable' level at image-field geometry test, 0.8 lp/mm for detector size of 34-40cm, 1.0 lp/mm for detector size of 28-33cm, 1.2 lp/mm for detector size of 22-27cm in spatial resolution test, minimum 200mg/cc in low contrast iodine detectability test, phantom entrance dose should be under 10R/min, 0.012 inch wire should be seen at static wire resolution test, and 0.022 inch wire should be seen at moving wire resolution test.

Design and Implementation of Fault-Tolerant IVR for Multi-Channel Service (다중 채널 서비스를 위한 결함허용 IVR 설계 및 구현)

  • Han, Yun-Ki;Koo, Yong-Wan
    • Journal of Internet Computing and Services
    • /
    • v.9 no.3
    • /
    • pp.103-117
    • /
    • 2008
  • General customer uses internet, SMS(Short Message Service), ATM(Automated Teller Machine), DM(Direct Mail), and telephony services, etc, for service of big businesses and small and medium enterprises, securities, financial institutions, bank. In particular, the case of Fire insurance & Securities, financial institutions, banks must meet Real-Time constrain control through QoS(Quality of Service) ensure. In this paper, we design and implement a system model about Fault-Tolerance IVR(Interactive Voice Response) of Multi Channel Service based on CRM(Customer Relationship Management) environment for the first inbound position of customer. The proposed model can be widely used in Large-scale Customer Response service.

  • PDF

Evaluation of Radiation Entrance Surface Dose Rates for Interventional Radiology Equipment (인터벤션 방사선발생장치에서 입사표면선량률 평가)

  • Kang, Byung-Sam;Chang, Kwang-Hyun
    • Journal of radiological science and technology
    • /
    • v.43 no.5
    • /
    • pp.353-357
    • /
    • 2020
  • IVR procedures are on the rise, and patient doses are on the rise. It is necessary to evaluate fluoroscopy dose in IVR procedure. Evaluate ESD on IVR equipment as a reference to DRL settings, I would like to present the direction of improvement in the ESD rate test criteria for fluoroscopy dose. The experimental method is measured with 6cc ionization chamber under the 20cm PMMA Phantom. Radiation is subject to abdominal procedure. The average dose rate of the incident surface was 21.6 ± 11.4 mGy/min. The highest dose equipment was 58.5 mGy/min, and there was no equipment exceeding the domestic standard of 100 mGy/min. However, there were five units above 50 mGy/min. To reduce fluoroscopy dose, it is recommended to reduce pulse rate, The dose increases as the image receptor ages. It is recommended to modify the domestic inspection criteria to 50 mGy/min.

Edge-Preserving Directional Regularization Technique for Disparity Estimation and Intermediate View Reconstruction of Stereoscopic Images (경계-보존 방향성 평활화를 이용한 양안 영상의 변이 추정과 중간 시점 영상의 재구성)

  • 김미현;강문기;이철희;최윤식;손광훈
    • Journal of Broadcast Engineering
    • /
    • v.4 no.1
    • /
    • pp.59-67
    • /
    • 1999
  • In this paper, we study two important topics in stereoscopic image communication system. One is a disparity estimation (DE) method to obtain the depth information of a scene at the transmitter and the other is an intermediate view reconstruction(IVR) method at the receiver. We propose a new DE method using an edge-preserving directional regularization technique. The proposed DE method smooths disparity vectors in smooth regions and preserves edges without over-smoothing problem. It provides better reconstructed stereoscopic images and improved coding efficiency than the existing regularization techniques. In addition. we propose a new IVR method using interpolation and extrapolation techniques. The proposed IVR method preserves edge regions as well as occlusion regions well. Thus. it gives better intermediate views than the existing IVR methods.

  • PDF