• 제목/요약/키워드: IVIS

검색결과 19건 처리시간 0.027초

Poloxamer 407 Hydrogels for Intravesical Instillation to Mouse Bladder: Gel-Forming Capacity and Retention Performance

  • Kim, Sang Hyun;Kim, Sung Rae;Yoon, Ho Yub;Chang, In Ho;Whang, Young Mi;Cho, Min Ji;Kim, Myeong Joo;Kim, Soo Yeon;Lee, Sang Jin;Choi, Young Wook
    • 대한비뇨기종양학회지
    • /
    • 제15권3호
    • /
    • pp.178-186
    • /
    • 2017
  • Purpose: Poloxamer 407 (P407) thermo-sensitive hydrogel formulations were developed to enhance the retention time in the urinary bladder after intravesical instillation. Materials and Methods: P407 hydrogels (P407Gels) containing 0.2 w/w% fluorescein isothiocyanate dextran (FD, MW 4 kDa) as a fluorescent probe were prepared by the cold method with different concentrations of the polymer (20, 25, and 30 w/w%). The gel-forming capacities were characterized in terms of gelation temperature (G-Temp), gelation time (G-Time), and gel duration (G-Dur). Homogenous dispersion of the probe throughout the hydrogel was observed by using fluorescence microscopy. The in vitro bladder simulation model was established to evaluate the retention and drug release properties. P407Gels in the solution state were administered to nude mice via urinary instillation, and the in vivo retention behavior of P407Gels was visualized by using an in vivo imaging system (IVIS). Results: P407Gels showed a thermo-reversible phase transition at $4^{\circ}C$ (refrigerated; sol) and $37^{\circ}C$ (body temperature; gel). The G-Temp, G-Time, and G-Dur of FD-free P407Gels were approximately $10^{\circ}C-20^{\circ}C$, 12-30 seconds, and 12-35 hours, respectively, and were not altered by the addition of FD. Fluorescence imaging showed that FD was spread homogenously in the gelled P407 solution. In a bladder simulation model, even after repeated periodic filling-emptying cycles, the hydrogel formulation displayed excellent retention with continuous release of the probe over 8 hours. The FD release from P407Gels and the erosion of the gel, both of which followed zero-order kinetics, had a linear relationship ($r^2=0.988$). IVIS demonstrated that the intravesical retention time of P407Gels was over 4 hours, which was longer than that of the FD solution (<1 hour), even though periodic urination occurred in the mice. Conclusions: FD release from P407Gels was erosion-controlled. P407Gels represent a promising system to enhance intravesical retention with extended drug delivery.

Developing Visual Complexity Metrics for Automotive Human-Machine Interfaces

  • Kim, Ji Man;Hwangbo, Hwan;Ji, Yong Gu
    • 대한인간공학회지
    • /
    • 제34권3호
    • /
    • pp.235-245
    • /
    • 2015
  • Objective: The purpose of this study is to develop visual complexity metrics based on theoretical bases. Background: With the development of IT technologies, drivers process a large amount of information caused by automotive human-machine interface (HMI), such as a cluster, a head-up display, and a center-fascia. In other words, these systems are becoming more complex and dynamic than traditional driving systems. Especially, these changes can lead to the increase of visual demands. Thus, a concept and tool is required to evaluate the complicated systems. Method: We reviewed prior studies in order to analyze the visual complexity. Based on complexity studies and human perceptual characteristics, the dimensions characterizing the visual complexity were determined and defined. Results: Based on a framework and complexity dimensions, a set of metrics for quantifying the visual complexity was developed. Conclusion: We suggest metrics in terms of perceived visual complexity that can evaluate the in-vehicle displays. Application: This study can provide the theoretical bases in order to evaluate complicated systems. In addition, it can quantitatively measure the visual complexity of In-vehicle information system and be helpful to design in terms of preventing risks, such as human error and distraction.

Screen Size를 고려한 최적 Menu Structure에 관한 연구 (A Study on the Navigation Menu Structure with Screen Size)

  • 김성민;최재호;정의승;최광수;전명훈;박준호;안정희
    • 한국HCI학회:학술대회논문집
    • /
    • 한국HCI학회 2008년도 학술대회 2부
    • /
    • pp.380-385
    • /
    • 2008
  • 자동차 환경에서 운전자가 주행 Workload라는 Main Task의 제약조건 하에서 Navigation의 효율적인 수행을 위해서는 Navigation에서 제공하는 기능들에 대한 빠른 이해가 필요하며, 이에 부합하는 Navigation Interface 설계를 위해 Navigation의 Screen Size의 제약 조건 하의 Menu Structure의 Width와 Depth 기반의 정보량의 수준과 이에 따른 Menu Structure Type의 연구가 중요한 Issue로 여겨지고 있다. 따라서 본 연구에서는 운전 상황과 유사한 환경을 구축하여 Navigation의 7인치와 4인치의 터치 스크린 기반의 Interface 환경에서 운전자에게 각각 다른 Menu Structure를 제시하고, 수행도와 선호도를 비교하였다.

  • PDF

Improvement of Skin Photoaging by Polysaccharide Extract Derived from Tremella fuciformis (White Jelly Mushroom)

  • Choi, Jae-Hwan;Kim, Bora
    • Natural Product Sciences
    • /
    • 제27권4호
    • /
    • pp.300-306
    • /
    • 2021
  • Chronic ultraviolet (UV) radiation causes photoaging, which represents skin damage, disrupts skin barrier function, and promotes wrinkle formation. We investigated that the polysaccharide extract of an edible basidiomycetous white jelly mushroom, Tremella fuciformis, (TF-Glucan®) exhibited statistically photoprotective activity by inhibiting matrix metalloproteases (MMPs) and increasing collagen synthesis, and an anti-inflammatory activity by inhibiting nitric oxide and pro-inflammatory cytokines at the concentrations of less than 1000 ㎍/ml, which is not cytotoxic (p < 0.05). Additionally, TF-Glucan® increased the expression of involucrin and filaggrin to prevent the disruption of UVB-induced barrier function (p < 0.05). TF-Glucan® was assessed as a safe material by the human primary skin irritation (1, 3, 5%), human repeated insult patch test (no sensitization at 5%), 3T3 NRU phototoxicity assay (no phototoxicity, PIF < 2, MPE < 0.1), eye irritation test test by BCOP (no category, IVIS ≤ 3) and local lymph node assay (negative at 10, 25, 50%) for identifying potential skin sensitizing. These results suggest that TF-Glucan® may be useful as an anti-photoaging ingredient for developing cosmeceuticals.

스티어링 휠의 터치패드를 이용한 정보 목록 검색 시 조작 : 반응 비율에 관한 연구 (Determination of the Optimal Control-Response Ratio for Data Searching Through a Touchpad Placed on the Steering Wheel)

  • 김종석;정의승;박성준;정성욱
    • 대한산업공학회지
    • /
    • 제35권2호
    • /
    • pp.141-149
    • /
    • 2009
  • As the number of personal computers installed in vehicles increases, a touchpad often used in a labtop computer can be used for the control of an in-vehicle information system (IVIS). Using a touchpad to control the system allows the user to select among large amount of information with a single touch of dragging. For safety and convenience of a driver, the touchpad could be placed on a steering wheel. This research is designed to calculate the most efficient Control-Response Ratio (C/R ratio) for the menu interaction of a touchpad on a steering wheel. Since the menu pointer's rate of movement and proper C/R ratio is determined by the amount of selected information, the amount of displayed information and the movement of a menu pointer was chosen to be independent variables. The dependent variables are a user's preference and task completion time. Two factor full factorial within subject design was used 16 subjects. The investigation revealed that the amount of selected information increased with increasing C/R ratio. The movement of the pointer became slower as the amount of information increased. The best C/R ratio was calculated for each amount of information and preference regression of the user's preference was drawn accordingly. Through this research, the automobile interior designer can benefit from the guidelines suggested for the touchpad control.

The Characterization of Anti-HER-2/neu Monoclonal Antibody using Different in vivo Imaging Techniques

  • Moon, Cheol;Kim, Eun Jung;Choi, Dan Bee;Kim, Byoung Soo;Kim, Sa Hyun;Choi, Tae Hyun
    • 대한의생명과학회지
    • /
    • 제21권1호
    • /
    • pp.23-31
    • /
    • 2015
  • Recently, specific antibodies have been used extensively to diagnose and treat various diseases. It is essential to assess the efficacy and specificity of antibodies, especially the in vivo environment. Anti-HER-2/neu mAb was evaluated as a possible transporting agent for radioimmunotherapy. The monoclonal antibody was successfully radio-labeled with $^{131}I$. In vitro binding assays were performed to confirm its targeting ability using another radio-iodine, $^{125}I$. Binding percentage of $^{125}I$ labeled anti-HER-2/neu mAb in HER-2/neu expressing CT-26 cells was found to be 4.5%, whereas the binding percentage of $^{125}I$ labeled anti-HER-2/neu mAb in wild-type CT-26 was only 0.45%. In vivo images were obtained and analyzed through $\gamma$-camera and an optical fluorescent modality, IVIS-200. $\gamma$-camera images showed that $^{131}I$ labeled anti-HER-2/neu mAb accumulated in HER-2/neu CT-26 tumors. Optical imaging based on near infrared fluorescence labeled anti-HER-2/neu mAb showed higher fluorescence intensities in HER-2/neu CT-26 tumors than in wild-type CT-26 tumors. Anti-HER-2/neu mAb was found to specifically bind to its receptor expressing tumor. Our study demonstrates that in vivo imaging technique is a useful method for the evaluation of an antibody's therapeutic and diagnostic potentials.

Lentivirus System을 이용한 Glucocorticoid 유도 Reporter 유전자 발현의 분석 (In vitro Analysis of Glucocorticoid-induced Reporter Gene Expression Using Lentivirus System)

  • 이미숙;김지연;허송욱
    • 한국해양바이오학회지
    • /
    • 제2권2호
    • /
    • pp.81-85
    • /
    • 2007
  • 글루코코르티코이드의 다양한 생리학적 과정은 이 호르몬에 의해 활성화된 수용체가 표적 유전자의 전사를 촉진 혹은 억제시킴으로써 일어나게 된다. 본 논문은 렌티바이러스 리포터 시스템을 이용하여 글루코코르티코이드 호르몬에 의한 GR 활성을 핵내에서 GRE에 의해 유도된 리포터 단백질인 mRFP 또는 루시퍼라아제의 발현을 통해 정성, 정량화 하였다. 그 결과 GR이 endogenous 하게 발현되는 HeLa 세포에서 코티졸을 처리하였을 때 활성화된 GR에 의해 GRE-inducible한 RFP와 루시퍼라아제의 발현이 각각 공초점 형광 현미경과 IVIS-200을 이용하여 형광 또는 BLI을 통해 증가함을 확인하였다. 이러한 결과를 통해 렌티바이러스 리포터 시스템을 이용한 연구는 세포 내에서 뿐 만 아니라 향후 생체내에서의 GR signaling을 모니터링하는데 유용하게 사용되어질 수 있을 것이다.

  • PDF

Case reports of iatrogenic vascular injury in the trauma field: what is the same and what is different?

  • Kim, Youngwoong;Choi, Kyunghak;Choi, Seongho;Keum, Min Ae;Kim, Sungjeep;Kyoung, Kyu-Hyouck;Kim, Jihoon T;Noh, Minsu
    • Journal of Trauma and Injury
    • /
    • 제35권2호
    • /
    • pp.123-127
    • /
    • 2022
  • Iatrogenic vascular injury (IVI) can occur with any technique or type of surgery performed around a blood vessel. Patients with severe trauma are at risk of IVI. In this study, we describe our experiences of IVI in the trauma field. We reviewed five patients who were diagnosed with an IVI and received either surgical or endovascular treatment. Of the five patients, one had an arterial injury, three had venous injuries, and one had an arteriovenous fistula, a form of combined arterial and venous injuries. Of the five patients, four had undergone orthopedic surgery. The IVIs of three patients were immediately identified in the operating room and simultaneous vascular repair was performed. The remaining one patient underwent additional surgery for occlusion related to entrapment of the superficial femoral artery by a surgical wire used during orthopedic surgery. Complications presumably related to the IVI were identified in two patients. IVI in trauma patients can be successfully managed, but significant morbidity can occur. If an IVI is suspected, immediate evaluation and management are required.

라멜라 액정상 메이크업 클렌징 제형 (Makeup Cleansing Formulation with Lamellar Liquid Crystal Phase)

  • 여혜림;이지현;김수지;노민주;장지희;김연준;윤명석;유권종;이준배
    • 대한화장품학회지
    • /
    • 제43권1호
    • /
    • pp.79-86
    • /
    • 2017
  • 본 연구는 두 개의 편광판 사이에서 홀로그램과 같은 독특한 외관을 갖는 라멜라 액정상 메이크업 클렌징 제형에 관한 것이다. 라멜라 액정상을 갖는 메이크업 클렌징 제형 연구는 오래전부터 많이 시도되어 왔지만, 탁도 증가 및 점도 상승 등의 문제로 실제 상용화에는 한계가 있었다. 본 연구에서는 이러한 문제를 해결하기 위해 계면활성제의 알킬 체인에 의한 액정상의 유동성 증가와 음이온 계면활성제 도입에 따른 정전기적 반발력 증가를 이용하였다. 이를 통해 액정상의 결정화를 억제하여 안정한 액정상 제형을 확보할 수 있었다. 또한, 본 연구에서는 객관적이고 정량적인 클렌징력 평가를 위해 형광물질과 in vivo imaging system (IVIS) 장비를 이용하여 in vitro 클렌징력 평가법을 새롭게 도입하였다. 이렇게 개발된 클렌징력 평가법을 이용하여 라멜라 액정상 메이크업 클렌징 제형의 우수한 메이크업 클렌징력을 확인할 수 있었다. 한편, 본 연구에서 개발된 라멜라 액정상 메이크업 클렌징 제형을 직교 배열된 두 편광판 사이에 두면 홀로그램과 유사한 특이적인 무늬를 관측할 수 있다. 이러한 현상은 액정상 제형을 통과하는 가시광선과 라멜라 구조 사이의 간섭현상에 의한 것으로 추정된다. 클렌징 제형에서의 라멜라 구조는 소각 X선 산란분석(SAXS)을 이용하여 Bragg spacing ratio가 1 : 2의 정수비로 관찰되는 것을 통해 확인하였다. 본 연구를 통해 개발된 라멜라 액정상 메이크업 클렌징 제형은 우수한 경시 안정성과 클렌징력, 그리고 편광판 사이에서 관찰되는 홀로그램과 유사한 독특한 외관으로 인해 향후 새로운 메이크업 클렌징 제품 개발에 도움이 될 것으로 기대된다.