• Title/Summary/Keyword: IVIS

Search Result 19, Processing Time 0.023 seconds

Poloxamer 407 Hydrogels for Intravesical Instillation to Mouse Bladder: Gel-Forming Capacity and Retention Performance

  • Kim, Sang Hyun;Kim, Sung Rae;Yoon, Ho Yub;Chang, In Ho;Whang, Young Mi;Cho, Min Ji;Kim, Myeong Joo;Kim, Soo Yeon;Lee, Sang Jin;Choi, Young Wook
    • The Korean Journal of Urological Oncology
    • /
    • 제15권3호
    • /
    • pp.178-186
    • /
    • 2017
  • Purpose: Poloxamer 407 (P407) thermo-sensitive hydrogel formulations were developed to enhance the retention time in the urinary bladder after intravesical instillation. Materials and Methods: P407 hydrogels (P407Gels) containing 0.2 w/w% fluorescein isothiocyanate dextran (FD, MW 4 kDa) as a fluorescent probe were prepared by the cold method with different concentrations of the polymer (20, 25, and 30 w/w%). The gel-forming capacities were characterized in terms of gelation temperature (G-Temp), gelation time (G-Time), and gel duration (G-Dur). Homogenous dispersion of the probe throughout the hydrogel was observed by using fluorescence microscopy. The in vitro bladder simulation model was established to evaluate the retention and drug release properties. P407Gels in the solution state were administered to nude mice via urinary instillation, and the in vivo retention behavior of P407Gels was visualized by using an in vivo imaging system (IVIS). Results: P407Gels showed a thermo-reversible phase transition at $4^{\circ}C$ (refrigerated; sol) and $37^{\circ}C$ (body temperature; gel). The G-Temp, G-Time, and G-Dur of FD-free P407Gels were approximately $10^{\circ}C-20^{\circ}C$, 12-30 seconds, and 12-35 hours, respectively, and were not altered by the addition of FD. Fluorescence imaging showed that FD was spread homogenously in the gelled P407 solution. In a bladder simulation model, even after repeated periodic filling-emptying cycles, the hydrogel formulation displayed excellent retention with continuous release of the probe over 8 hours. The FD release from P407Gels and the erosion of the gel, both of which followed zero-order kinetics, had a linear relationship ($r^2=0.988$). IVIS demonstrated that the intravesical retention time of P407Gels was over 4 hours, which was longer than that of the FD solution (<1 hour), even though periodic urination occurred in the mice. Conclusions: FD release from P407Gels was erosion-controlled. P407Gels represent a promising system to enhance intravesical retention with extended drug delivery.

Developing Visual Complexity Metrics for Automotive Human-Machine Interfaces

  • Kim, Ji Man;Hwangbo, Hwan;Ji, Yong Gu
    • Journal of the Ergonomics Society of Korea
    • /
    • v.34 no.3
    • /
    • pp.235-245
    • /
    • 2015
  • Objective: The purpose of this study is to develop visual complexity metrics based on theoretical bases. Background: With the development of IT technologies, drivers process a large amount of information caused by automotive human-machine interface (HMI), such as a cluster, a head-up display, and a center-fascia. In other words, these systems are becoming more complex and dynamic than traditional driving systems. Especially, these changes can lead to the increase of visual demands. Thus, a concept and tool is required to evaluate the complicated systems. Method: We reviewed prior studies in order to analyze the visual complexity. Based on complexity studies and human perceptual characteristics, the dimensions characterizing the visual complexity were determined and defined. Results: Based on a framework and complexity dimensions, a set of metrics for quantifying the visual complexity was developed. Conclusion: We suggest metrics in terms of perceived visual complexity that can evaluate the in-vehicle displays. Application: This study can provide the theoretical bases in order to evaluate complicated systems. In addition, it can quantitatively measure the visual complexity of In-vehicle information system and be helpful to design in terms of preventing risks, such as human error and distraction.

A Study on the Navigation Menu Structure with Screen Size (Screen Size를 고려한 최적 Menu Structure에 관한 연구)

  • Kim, Seong-Min;Choe, Jae-Ho;Jung, Eui-S.;Choi, Kwang-Soo;Jeon, Myoung-Hoon;Park, Jun-Ho;Ahn, Jeong-Hee
    • 한국HCI학회:학술대회논문집
    • /
    • 2008.02b
    • /
    • pp.380-385
    • /
    • 2008
  • To perform the navigation functions more efficiently, the navigation menu structure should be provided easy to understand to the driver in the vehicle environment that is restricted by driving workload, According to these conditions, to design better navigation interface, it is important to study on the navigation menu structure that is depend on the screen size and the information width and depth. Therefore, in this study we provided the different menu structures of 7-inch touchscreen LCD and 4-inch touchscreen LCD to the driver respectively in the driving simulator. Then, we compared the preference of each menu structures with the different touchscreen LCD.

  • PDF

Improvement of Skin Photoaging by Polysaccharide Extract Derived from Tremella fuciformis (White Jelly Mushroom)

  • Choi, Jae-Hwan;Kim, Bora
    • Natural Product Sciences
    • /
    • v.27 no.4
    • /
    • pp.300-306
    • /
    • 2021
  • Chronic ultraviolet (UV) radiation causes photoaging, which represents skin damage, disrupts skin barrier function, and promotes wrinkle formation. We investigated that the polysaccharide extract of an edible basidiomycetous white jelly mushroom, Tremella fuciformis, (TF-Glucan®) exhibited statistically photoprotective activity by inhibiting matrix metalloproteases (MMPs) and increasing collagen synthesis, and an anti-inflammatory activity by inhibiting nitric oxide and pro-inflammatory cytokines at the concentrations of less than 1000 ㎍/ml, which is not cytotoxic (p < 0.05). Additionally, TF-Glucan® increased the expression of involucrin and filaggrin to prevent the disruption of UVB-induced barrier function (p < 0.05). TF-Glucan® was assessed as a safe material by the human primary skin irritation (1, 3, 5%), human repeated insult patch test (no sensitization at 5%), 3T3 NRU phototoxicity assay (no phototoxicity, PIF < 2, MPE < 0.1), eye irritation test test by BCOP (no category, IVIS ≤ 3) and local lymph node assay (negative at 10, 25, 50%) for identifying potential skin sensitizing. These results suggest that TF-Glucan® may be useful as an anti-photoaging ingredient for developing cosmeceuticals.

Determination of the Optimal Control-Response Ratio for Data Searching Through a Touchpad Placed on the Steering Wheel (스티어링 휠의 터치패드를 이용한 정보 목록 검색 시 조작 : 반응 비율에 관한 연구)

  • Kim, Jong-Seok;Jung, Eui-S.;Park, Sung-Joon;Jeong, Seong-Wook
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.35 no.2
    • /
    • pp.141-149
    • /
    • 2009
  • As the number of personal computers installed in vehicles increases, a touchpad often used in a labtop computer can be used for the control of an in-vehicle information system (IVIS). Using a touchpad to control the system allows the user to select among large amount of information with a single touch of dragging. For safety and convenience of a driver, the touchpad could be placed on a steering wheel. This research is designed to calculate the most efficient Control-Response Ratio (C/R ratio) for the menu interaction of a touchpad on a steering wheel. Since the menu pointer's rate of movement and proper C/R ratio is determined by the amount of selected information, the amount of displayed information and the movement of a menu pointer was chosen to be independent variables. The dependent variables are a user's preference and task completion time. Two factor full factorial within subject design was used 16 subjects. The investigation revealed that the amount of selected information increased with increasing C/R ratio. The movement of the pointer became slower as the amount of information increased. The best C/R ratio was calculated for each amount of information and preference regression of the user's preference was drawn accordingly. Through this research, the automobile interior designer can benefit from the guidelines suggested for the touchpad control.

The Characterization of Anti-HER-2/neu Monoclonal Antibody using Different in vivo Imaging Techniques

  • Moon, Cheol;Kim, Eun Jung;Choi, Dan Bee;Kim, Byoung Soo;Kim, Sa Hyun;Choi, Tae Hyun
    • Biomedical Science Letters
    • /
    • v.21 no.1
    • /
    • pp.23-31
    • /
    • 2015
  • Recently, specific antibodies have been used extensively to diagnose and treat various diseases. It is essential to assess the efficacy and specificity of antibodies, especially the in vivo environment. Anti-HER-2/neu mAb was evaluated as a possible transporting agent for radioimmunotherapy. The monoclonal antibody was successfully radio-labeled with $^{131}I$. In vitro binding assays were performed to confirm its targeting ability using another radio-iodine, $^{125}I$. Binding percentage of $^{125}I$ labeled anti-HER-2/neu mAb in HER-2/neu expressing CT-26 cells was found to be 4.5%, whereas the binding percentage of $^{125}I$ labeled anti-HER-2/neu mAb in wild-type CT-26 was only 0.45%. In vivo images were obtained and analyzed through $\gamma$-camera and an optical fluorescent modality, IVIS-200. $\gamma$-camera images showed that $^{131}I$ labeled anti-HER-2/neu mAb accumulated in HER-2/neu CT-26 tumors. Optical imaging based on near infrared fluorescence labeled anti-HER-2/neu mAb showed higher fluorescence intensities in HER-2/neu CT-26 tumors than in wild-type CT-26 tumors. Anti-HER-2/neu mAb was found to specifically bind to its receptor expressing tumor. Our study demonstrates that in vivo imaging technique is a useful method for the evaluation of an antibody's therapeutic and diagnostic potentials.

In vitro Analysis of Glucocorticoid-induced Reporter Gene Expression Using Lentivirus System (Lentivirus System을 이용한 Glucocorticoid 유도 Reporter 유전자 발현의 분석)

  • Lee, Mi-Sook;Kim, Ji-Yeon;Her, Song
    • Journal of Marine Bioscience and Biotechnology
    • /
    • v.2 no.2
    • /
    • pp.81-85
    • /
    • 2007
  • Glucocorticoid hormone regulates numerous physiological processes, such as regulation of metabolism, and anti-inflammatory and immunosuppressive actions via the activation and repression of gene expression. Here we described a lentivirus-based reporter vector system expressing red fluorescent protein (mRFP) or firefly luciferase (Luc) under the control of a glucocorticoid-responsive element that allows observation of the temporospatial pattern of glucocorticoid induced GR-mediated signaling on a cellular level. Moreover, usage of the chromatin insulator of the chicken ${\beta}$-globin locus induced a marked increase of sensitivity of glucocorticoid inducible promoter of a reporter gene. Use of this method will be applicable of screening for agonist and antagonist of GR in vitro, and also a reporter gene assay for the in vivo determination of the GR-mediated gene activation.

  • PDF

Case reports of iatrogenic vascular injury in the trauma field: what is the same and what is different?

  • Kim, Youngwoong;Choi, Kyunghak;Choi, Seongho;Keum, Min Ae;Kim, Sungjeep;Kyoung, Kyu-Hyouck;Kim, Jihoon T;Noh, Minsu
    • Journal of Trauma and Injury
    • /
    • v.35 no.2
    • /
    • pp.123-127
    • /
    • 2022
  • Iatrogenic vascular injury (IVI) can occur with any technique or type of surgery performed around a blood vessel. Patients with severe trauma are at risk of IVI. In this study, we describe our experiences of IVI in the trauma field. We reviewed five patients who were diagnosed with an IVI and received either surgical or endovascular treatment. Of the five patients, one had an arterial injury, three had venous injuries, and one had an arteriovenous fistula, a form of combined arterial and venous injuries. Of the five patients, four had undergone orthopedic surgery. The IVIs of three patients were immediately identified in the operating room and simultaneous vascular repair was performed. The remaining one patient underwent additional surgery for occlusion related to entrapment of the superficial femoral artery by a surgical wire used during orthopedic surgery. Complications presumably related to the IVI were identified in two patients. IVI in trauma patients can be successfully managed, but significant morbidity can occur. If an IVI is suspected, immediate evaluation and management are required.

Makeup Cleansing Formulation with Lamellar Liquid Crystal Phase (라멜라 액정상 메이크업 클렌징 제형)

  • Yeo, Hye Lim;Lee, Ji Hyun;Kim, Su Ji;Noh, Minjoo;Jang, Ji Hui;Kim, Youn Joon;Yoon, Moung Seok;Yoo, Kweon Jong;Lee, Jun Bae
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.43 no.1
    • /
    • pp.79-86
    • /
    • 2017
  • This study is related to a lamellar liquid crystal make-up cleansing formulation with a hologram-like unique appearance between two polarizing plates. Make-up cleansing formulations with a lamellar liquid crystal phase have been extensively studied for a long time, but there have been limitations in practical commercialization because of increasing turbidity and viscosity. In this study, to solve this problem, alkyl chains of surfactants were modified to increase the fluidity of the liquid crystal phase, and electrostatic repulsion force was increased by introducing anionic surfactant. The lamellar liquid crystal make-up cleansing formulation which introduced anionic surfactants can easily inhibit crystallization through electrostatic repulsion force, thereby showing excellent stability overtime, maintaining transparent appearance and viscosity. In addition, we have newly introduced an in vitro cleansing evaluation method using fluorescent material and in vivo imaging system (IVIS) for objective and quantitative cleansing ability evaluation. The excellent cleansing ability of lamellar liquid crystal cleansing formulation has been confirmed by newly developed evaluation method. On the other hand, when lamellar liquid crystal make-up cleansing formulation was placed between orthogonally arranged two polarizing plates, a specific pattern like a hologram can be observed. This phenomenon is presumably interpreted as the interference between the visible light passing through the liquid crystal formulation and the lamellar structure. The lamellar structure of cleansing formulation was confirmed by SAXS analysis, exhibiting Bragg spacing ratio of 1 : 2. The lamellar liquid crystal make-up cleansing formulation prepared in this study would be useful for future application in make-up cleansing due to its excellent stability, cleansing ability, and unique hologram-like pattern placed between two polarizing plates.