A Study on the Over-current Characteristics of IV Insulated Wire Sheath According to Accelerated Degradation (가속열화에 따른 IV절연전선 피복의 과전류 특성에 관한 연구)

  • Kim, Si-Kuk;Choi, Su-Gil
    • Fire Science and Engineering
    • /
    • v.32 no.2
    • /
    • pp.48-56
    • /
    • 2018
  • This paper reports the results of a study on the over-current characteristics of IV insulated wire sheath according to accelerated degradation. In order to examine the degradation of a IV insulated wire sheath through insulation, acceleration degradation experiments were performed using the Arrhenius equation of acceleration life test models; test samples with equivalent lives of 0, 10, 20, 30 and 40 years were prepared. Then allowed currents with over-current of 100%~500% were introduced to measure the times of first generation of smokes and carbonization in the wire sheath, and it was found that the times of first generation of smokes and carbonization in the wire sheath decreased as the equivalent life increased. In more detail, when 270% over-current is applied, the electrical fire risk of equivalent life of 40 years increased by approximately 3.2 times based on equivalent life of 0 years. Also, when the over-current was 255% and 260%, carbonization occurred only in the equivalent life of 40 years, and the fire risk according to the accelerated degradation was increased dramatically. In addition, FT-IR and SEM analyzes were used to confirm the characteristics and surface changes of IV insulated wire sheath according to the equivalent life.

A Study on the Performance Change of Insulation Sheath Due to Accelerated Degradation of IV and HIV Insulated Wire (IV 및 HIV 절연전선의 가속열화에 따른 절연피복의 성능변화에 관한 연구)

  • Choi, Su-Gil;Kim, Si-Kuk
    • Fire Science and Engineering
    • /
    • v.33 no.2
    • /
    • pp.114-123
    • /
    • 2019
  • The paper relates to a study on the changes in performance of insulation sheath resulting from accelerated degradation of IV and HIV insulated wire. To assume insulation degradation of IV and HIV insulated wire, accelerated life tests using Arrhenius equation were conducted among accelerated life test models, and experimental samples of 0 year, 10 years, 20 years, 30 years, and 40 years in equivalent life were produced. Whereas the maximum tensile load were increased as accelerated degradation of IV and HIV insulated wire progressed, elongation percentage, rupture time, and flexibility of insulated wires were found to be gradually reduced. According to the additional surface analysis results for the insulated wires per equivalent life using a scanning electron microscope, mechanical properties of the insulator were observed to be reduced as insulation degradation resulting from aging progressed since phenomena such as formation of crystalline structures and perforation, etc. occurred on the sample surface with progression of accelerated degradation. Consequently, institutional replacement of insulated wires and preparation of repair times considering performance degradation of the insulator installed inside buildings are considered necessary in order to prevent in advance the risks of electrical fire resulting from degradation in insulation performance.

Lifetime Prediction on PVC Insulation Material for IV and HIV Insulated Wire (IV와 HIV 절연 전선용 PVC 절연재료의 수명 예측)

  • Park, Hyung-Ju
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.1
    • /
    • pp.8-13
    • /
    • 2019
  • Weight and elongation changes of IV and HIV insulations were measured simultaneously at several given temperature of $80^{\circ}C$, $90^{\circ}C$ and $100^{\circ}C$. And the lifetime was predicted using the Arrhenius model. Based on the initial weight values, a 50% elongation reduction was seen at 6.96% for the IV insulation and 10.29% for the HIV insulation. The activation energy from the slope of the lifetime regression equation was calculated as 92.895 kJ/mol(0.9632 eV) for the IV insulation and 95.213 kJ/mol(0.9873 eV) for the HIV insulation. Also, the expected lifetime at the operating temperature of $30^{\circ}C$ to $90^{\circ}C$ is 2.02 to 94.32 years, and longer lifetime was predicted on HIV insulated wires than on IV insulated wires. As a result, it was found that the thermal characteristics of the HIV insulated wires were about 12.44% better than those of IV insulated wires under the same conditions of use.

The Properties Analysis of 600V Grade Polyvinyl Chloride Insulated Wire with Variation of Thermal Stress (열적 스트레스 변화에 따른 600V 비닐절연전선의 특성 분석)

  • 최충석
    • Fire Science and Engineering
    • /
    • v.15 no.1
    • /
    • pp.108-115
    • /
    • 2001
  • In this paper, we analyzed the properties change of electric wire when the thermal stress was applied to 600V grade polyvinyl chloride insulated wire (IV). In the structure analysis, normal wire has the properties of direction on the surface, but in case of deteriorated wire at above $400^{\circ}c$, it formed the carbide, the crack and the crystal. The surface composition rate of normal wire was Cu : 100%, but the section composition of the deteriorated wire at $800^{\circ}c$ showed Cu : 78.89%, O : 21.11%. In result of analyzing the differential scanning calory of copper wire, the new reaction peak was observed on the deteriorated wire at above $700^{\circ}c$. In case of the deteriorated wire as $150^{\circ}c$ at the differential thermal analysis, an endothermic reaction appeared at $264^{\circ}c$ lower than the reactive point of normal wire. The occupation rate of oxygen according to the deterioration of copper wire is about 20% at $500^{\circ}c$.

  • PDF

Copper Oxide Growing Characteristics of PVC Insulated Wire and Application to the Fire Investigation (비닐절연전선의 산화물 성장 특성과 화재조사에의 적용)

  • Kim, Hyang-Kon;Choi, Chung-Seog;Kim, Dong-Ook;Choi, Hyo-Sang
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.56 no.1
    • /
    • pp.37-44
    • /
    • 2007
  • This paper describes characteristics for copper oxide growth of polyvinyl chloride(PVC) insulated wires by series arc. In this experiment, 600V IV wires were used, and characteristics of oxide growth and ignition process were analyzed in case load was 300W, 460W and 600W, respectively. In the result of experiment, covering materials were molten, carbonized and ignited, whereas, oxidized materials were grown in conducting material. During copper oxide was growing, contact voltages and power dissipations increased. When there is copper oxide growth, the waveform of current showed sinusoidal waveform, and the waveform of voltage showed modified waveform. Oxidized materials were heated at about $905^{\circ}C$, surface structure showed irregular shapes, and cross-section showed multiple cracks. And, the results of this experiment were applied to the fire cause analysis of fire evidence collected at the fire scene.

Characteristics of Vinyl Insulated Wire with Thermal Treatment Conditions (열처리 조건에 따른 비닐절연전선의 특성 변화)

  • Choi, C.S.;Park, C.S.;Shong, K.M.;Lee, K.S.;Lee, D.C.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07d
    • /
    • pp.1401-1403
    • /
    • 1998
  • The composition, weight decrease, DTA, and surface structure of vinyl insulated wire with thermal treatment conditions have been investigated. The composition of Cu by EDX analysis indicates Cu, Cl, and O lines, and oxidation reaction results from thermal treatment. Thermal treated IV and HIV appeared chemical reaction at $269^{\circ}C$ and $265^{\circ}C$, respectively. SEM of thermal treated Cu at $250^{\circ}C$ disappears an elongation structure, and appears an original structure.

  • PDF

Analysis of Thermal Characteristics for the Fire Risk Assessment According to Partial Disconnection on the VCTF and IV Electric Wire (VCTF와 IV전선의 반단선에 의한 화재위험성 평가를 위한 열적특성 해석)

  • Kim, Doo-Hyun;Kim, Sung-Chul;Lee, Jong-Ho;Park, Jong-Young;Park, Young-Ho;Lee, Hyung-Jun
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.4
    • /
    • pp.47-52
    • /
    • 2008
  • Many researches on fire risk for normal electric wiring have been pursued in advanced countries such as the USA and Japan, but comparative studies of the partial disconnection and normal state of electric wires have not been conducted. Detection system for the cause of partial disconnection is not developed and prevention countermeasure for electrical fire by the cause is not effective. Therefore, in this paper, partial disconnection characteristics on electric wires were derived and analyzed by experiment and electrical-thermal finite element method(Flux 3D) on the model wires which consist of VCTF(PVC insulated PVC sheathed Cap Tyre Flexible Cord, KS C 3304) and IV(lndoorwire PVC, KS C 3302). VCTF is used in wiring portable electric appliances and the IV is used indoors. Interrelationships between partial disconnection premonitory symptom and current were derived and analyzed by the characteristics based on experiments and thermal analysis for electric wire according to current under normal state and 200% overload state of rated current.

A Study on the Composition Variation of 600v IV with Thermal Deterioration (열열화에에 따른 600V IV의 조성변화에 관한 연구)

  • 최충석;류선희;김형래;이경섭
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.53-56
    • /
    • 1999
  • The weight decreases of the thermal deteriorated IV were rapidly increased at 80$0^{\circ}C$ and over. At the results of the analysis of the metallurgical microscope photographs. the surface of the thermal deteriorated IV at 30$0^{\circ}C$ was mixed with the elongated and original structures of Cu. But the elongated structures could not detected at 90$0^{\circ}C$ and over. The surface structures of SEM were detected a lot of small rounded particles between crystallizations. The EDX spectra of the thermal deteriorated IV at 3$0^{\circ}C$ were uniformly detected CuL, CuK, OK, and CIK, regardless of the scanning length, but the spectra of CIK could not found at 90$0^{\circ}C$. At the DTA curves, the endothermic reactions were occurred at about 25$0^{\circ}C$ to 30$0^{\circ}C$ and 43$0^{\circ}C$, and the exothermic reactions were occurred at about 48$0^{\circ}C$ respectively.

  • PDF

Shrinkage rate and Structure analysis of IV according to Thermal deterioration (열열화 온도에 따른 IV의 수축률 및 조직분석)

  • Choi, Chung-Seog;Kim, Hyung-Rae;Song, Kil-Mok;Kim, Hyang-Kon;Kim, Dong-Ook;Kim, Dong-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1416-1418
    • /
    • 2002
  • In order to examine the thermal properties of the wire materials, we analyzed the shrinkage, the expansion and the form transformation, the surface structure according to the thermal deterioration temperature through the testing method for a heating shrinkage of Korean Industrial Standard(KS C 3004). For IV(600V grade polyvinyl chloride insulated wires), we measured the shrinkage and the expansion rate, analyzed the surface structure using SEM(Scanning Electron Microscope). In the result of this experiment, the shrinkage rate of IV 2.0mm covering was high in comparison with other wires. As the deterioration temperature rises gradually, the covering is molten and harden.

  • PDF

Development of Electrical Fire Detection System Applying Fuzzy Logic for Main Causes of Electrical Fire in Traditional Market Shops

  • Kim, Doo Hyun;Hwang, Dong Kyu;Kim, Sung Chul;Kim, Sang Ryull;Kim, Yoon Bok
    • International Journal of Safety
    • /
    • v.11 no.2
    • /
    • pp.15-21
    • /
    • 2012
  • This paper is aimed to develop an electrical fire detection system (EFDS) which can analyze the possibility of electrical fire for overcurrent, leakage current and arc signals of panel board in traditional market shop. The EFDS adopted fuzzy logic and precursory data for overcurrent, leakage current and arc signals to evaluate the possibility of electrical fire. The signals are obtained directly from panel board in traditional market shops and fuzzy membership function is obtained from experiment, simulation, expert's advice. The overcurrent data is acquired by thermal data of normal and abnormal states (partial disconnection) on the insulated electrical wire, in accordance with the increase of the current signal, The leakage current data is obtained under various environments. The arc signal is acquisited by waveforms of instantaneous value in time domain and frequency band in frequency domain. The Fuzzy algorithm for DB of EFDS consists of fuzzification, inference engine by Mamdani's method and defuzzification by center of gravity method. In order to verify the performance and reliability of EFDS, it was applied to Jeon-Ju traditional market shops (90 shops) in Korea. Results show that EFDS in this paper is useful in alarming the fire case, which will prevent severe damage to human beings and properties, and reduce the electrical fires in a vulnerable area of electrical disaster.