• 제목/요약/키워드: ITV

검색결과 34건 처리시간 0.033초

Efficient approach for determining four-dimensional computed tomography-based internal target volume in stereotactic radiotherapy of lung cancer

  • Yeo, Seung-Gu;Kim, Eun Seog
    • Radiation Oncology Journal
    • /
    • 제31권4호
    • /
    • pp.247-251
    • /
    • 2013
  • Purpose: This study aimed to investigate efficient approaches for determining internal target volume (ITV) from four-dimensional computed tomography (4D CT) images used in stereotactic body radiotherapy (SBRT) for patients with early-stage non-small cell lung cancer (NSCLC). Materials and Methods: 4D CT images were analyzed for 15 patients who received SBRT for stage I NSCLC. Three different ITVs were determined as follows: combining clinical target volume (CTV) from all 10 respiratory phases ($ITV_{10Phases}$); combining CTV from four respiratory phases, including two extreme phases (0% and 50%) plus two intermediate phases (20% and 70%) ($ITV_{4Phases}$); and combining CTV from two extreme phases ($ITV_{2Phases}$). The matching index (MI) of $ITV_{4Phases}$ and $ITV_{2Phases}$ was defined as the ratio of $ITV_{4Phases}$ and $ITV_{2Phases}$, respectively, to the $ITV_{10Phases}$. The tumor motion index (TMI) was defined as the ratio of $ITV_{10Phases}$ to $CTV_{mean}$, which was the mean of 10 CTVs delineated on 10 respiratory phases. Results: The ITVs were significantly different in the order of $ITV_{10Phases}$, $ITV_{4Phases}$, and $ITV_{2Phases}$ (all p < 0.05). The MI of $ITV_{4Phases}$ was significantly higher than that of $ITV_{2Phases}$ (p < 0.001). The MI of $ITV_{4Phases}$ was inversely related to TMI (r = -0.569, p = 0.034). In a subgroup with low TMI (n = 7), $ITV_{4Phases}$ was not statistically different from $ITV_{10Phases}$ (p = 0.192) and its MI was significantly higher than that of $ITV_{2Phases}$ (p = 0.016). Conclusion: The $ITV_{4Phases}$ may be an efficient approach alternative to optimal $ITV_{10Phases}$ in SBRT for early-stage NSCLC with less tumor motion.

호흡 동조 구동 팬톰을 이용한 호흡패턴에 따른 4DCT, Slow-CT의 내부표적체적 변화 연구 (Study of Variation of Internal Taget Volume between 4DCT and Slow-CT in Respiratory Patterns Using Respiratory Motion Phantom)

  • 이순성;최상현;민철기;지영훈;김미숙;유형준;김찬형;김금배
    • 한국의학물리학회지:의학물리
    • /
    • 제25권1호
    • /
    • pp.53-63
    • /
    • 2014
  • 본 연구에서는 호흡 동조 구동 팬톰을 이용하여 5가지의 호흡패턴에 따른 4DCT와 Slow-CT의 내부표적체적(ITV) 변화를 비교 분석하였다. 각 호흡패턴마다 호흡주기 1~4초와 표적 진폭 1~3 cm를 적용하여 4DCT와 Slow-CT를 각 3회 촬영하였다. 촬영한 영상들은 Eclipse 치료계획 시스템으로 표적을 윤곽 묘사하고 내부표적체적(ITV) 길이와 체적을 측정하였으며, 4DCT, Slow-CT의 ITV 길이와 체적의 평균값을 이론값과 비교하여 분석하였다. 4DCT에서의 ITV 길이와 체적은 호흡주기가 길수록, 표적 진폭이 짧을수록 이론값과의 차이가 감소하는 경향을 보였다. Slow-CT에서는 표적 진폭이 커질수록 4DCT와 마찬가지로 이론값과의 차이가 커졌으나 호흡주기에 따른 ITV 길이와 체적의 변화는 호흡주기 1초에서 가장 이론값 비슷하였고 2~4초 내에서는 재현성의 변화가 근소했다. 호흡패턴에 따라서는 4DCT, Slow-CT 모두 ITV 길이와 체적에 대해 A패턴에서 가장 높은 재현성을 보였고, B, C, D패턴은 서로 비슷한 차이를 보였으며 E패턴은 다른 네 패턴에 비해 이론값과의 차이가 가장 컸다. 4DCT에 대한 Slow-CT의 ITV 길이와 체적의 차이는 모든 호흡패턴에 대하여 호흡주기가 길수록, 표적 진폭이 클수록 증가하였다. 4DCT와 Slow-CT 영상간의 ITV 길이 및 체적에 대한 재현성을 비교했을 때 Slow-CT가 4DCT에 비해 평균적으로 약 22% 낮았으며, 호흡패턴에 따라 상, 하 방향에 대해 표적의 재현성이 달라졌다. A, B, C패턴의 경우 상, 하 방향으로 3 mm, E패턴은 상 방향에 비해 하 방향에서 5 mm의 차이를 보인 반면에 D패턴에서는 상 방향으로는 차이가 없었으나 하 방향으로 1.45 cm의 차이가 났다. 따라서 4DCT에 대하여 Slow-CT에 표적 움직임을 고려한 여유를 설정할 경우에는 호흡패턴에 따라 상, 하 방향에 다른 여유를 정의해야 한다고 판단된다. 향후 환자의 호흡신호를 바탕으로 CT 영상을 분석할 때 본 연구에서 수행한 데이터가 유용하게 사용될 것으로 사료된다.

영국 ITV Digital의 실패에 관한 연구 (Critical Analysis of ITV Digital in UK)

  • 김승수
    • 한국언론정보학보
    • /
    • 제20권
    • /
    • pp.7-32
    • /
    • 2003
  • 디지털방송은 나라마다 전략 산업으로 확정되어 급속히 발전하는 중이다. 디지털 방송은 지상파방송, 위성방송, CATV에 이르기까지 방송의 구조를 근본적으로 바꾸는 힘을 갖고 있다. 경제적으로 보면 디지털 방송은 천문학적인 비용이 들어가는 사업이다. 그래서 디지털방송정책은 신중히 수립되어야 한다. 디지털방송 사업자 역시 다른 어떤 사업보다 신중한 자세로 사업을 진척시켜야 할 것이다. 하지만 디지털방송의 전도는 지극히 불투명하다 특히 디지털 지상파방송의 불투명성은 더 심각하다. 한국에서도 디지털 지상파방송은 충 70조 원까지 들어간다는 예측도 있지만 막대한 자본이 소요되는 사업이어서 정부, 방송사, 수용자, 학계 누구하나 디지털 방송사업에 소극적인 자세를 보이고 있다. 이런 상황에서 우리보다 먼저 디지털 지상파방송을 실시한 나라를 참고하면 많은 교훈을 얻을 수 있을 것이다. 이에 필자는 영국 ITV Digital 방송의 실패 원인을 분석함으로써 한국 디지털 지상파방송의 발전에 유용한 교훈을 얻으려 할 것이다.

  • PDF

ITV 시스템에서 MPEG-4 실시간 장면 랜더링 (MPEG-4 realtime rendering on ITV system)

  • 이윤주;김상욱
    • 한국정보과학회:학술대회논문집
    • /
    • 한국정보과학회 2000년도 봄 학술발표논문집 Vol.27 No.1 (B)
    • /
    • pp.417-419
    • /
    • 2000
  • 본 논문은 실시간 운영체제 기반의 ITV 시스템에서 MPEG-4 멀티미디어 장면을 실시간으로 랜더링하는 방법을 제시한다. MPEG-4 멀티미디어 스트림의 랜더링을 위한 장면 구성은 ITV 시스템에서 네트워크를 통해 전송되는 멀티미디어 스트림을 파싱 및 해석하여 장면그래프를 구성하고, 장면 랜더러가 이 장면 그래프를 이용하여 화면에 실시간으로 랜더링한다. MPEG-4 장면 랜더링 화면에서 사용자의 객체 교체나 객체 속성 변환 랜더링 이벤트가 발생하면, MPEG-4 장면 그래프를 실시간으로 갱신시켜 사용자 인터페이스에 랜더링한다.

  • PDF

Visibility of Internal Target Volume of Dynamic Tumors in Free-breathing Cone-beam Computed Tomography for Image Guided Radiation Therapy

  • Kauweloa, Kevin I.;Park, Justin C.;Sandhu, Ajay;Pawlicki, Todd;Song, Bongyong;Song, William Y.
    • 한국의학물리학회지:의학물리
    • /
    • 제24권4호
    • /
    • pp.220-229
    • /
    • 2013
  • Respiratory-induced dynamic tumors render free-breathing cone-beam computed tomography (FBCBCT) images with motion artifacts complicating the task of quantifying the internal target volume (ITV). The purpose of this paper is to study the visibility of the revealed ITV when the imaging dose parameters, such as the kVp and mAs, are varied. The $Trilogy^{TM}$ linear accelerator with an On-Board Imaging ($OBI^{TM}$) system was used to acquire low-imaging-dose-mode (LIDM: 110 kVp, 20 mA, 20 ms/frame) and high-imaging-dose-mode (HIDM: 125 kVp, 80 mA, 25 ms/frame) FBCBCT images of a 3-cm diameter sphere (density=0.855 $g/cm^3$) moving in accordance to various sinusoidal breathing patterns, each with an unique inhalation-to-exhalation (I/E) ratio, amplitude, and period. In terms of image ITV contrast, there was a small overall average change of the ITV contrast when going from HIDM to LIDM of $6.5{\pm}5.1%$ for all breathing patterns. As for the ITV visible volume measurements, there was an insignificant difference between the ITV of both the LIDM- and HIDM-FBCBCT images with an average difference of $0.5{\pm}0.5%$, for all cases, despite the large difference in the imaging dose (approximately five-fold difference of ~0.8 and 4 cGy/scan). That indicates that the ITV visibility is not very sensitive to changes in imaging dose. However, both of the FBCBCT consistently underestimated the true ITV dimensions by up to 34.8% irrespective of the imaging dose mode due to significant motion artifacts, and thus, this imaging technique is not adequate to accurately visualize the ITV for image guidance. Due to the insignificant impact of imaging dose on ITV visibility, a plausible, alternative strategy would be to acquire more X-ray projections at the LIDM setting to allow 4DCBCT imaging to better define the ITV, and at the same time, maintain a reasonable imaging dose, i.e., comparable to a single HIDM-FBCBCT scan.

실시간 OS용 ITV 개발 (ITV Development on Realtime OS)

  • 김상욱;신규상;마평수;신용경;이윤주;김원국;조창식
    • 한국정보처리학회:학술대회논문집
    • /
    • 한국정보처리학회 2000년도 제13회 춘계학술대회 및 임시총회 학술발표 논문집
    • /
    • pp.159-164
    • /
    • 2000
  • 이 논문에서는 조립형 실시간 OS에서 운용되는 지능형 텔레비젼(Intelligent Television, ITV)을 개발한다. 인터넷에서의 웹기반 TV에 대하여 여러 연구가 있었지만, 실시간 운영체제가 아니어서 여러 문제를 가지고 있다. 이 논문은 실시간 OS에서의 ITV 개발에서 MPEG-4 프리젠터를 중심으로 설명한다. 즉, 미디어 서버에서 분배 관리기, MPEG-4 압축, 미디어 재생기까지의 일련의 미디어 전송 과정을 거쳐 프리젠테이션 과정을 기술한다. 이 논문의 ITV는 한국전자통신연구원에서 개발 중인 실시간 운영체제에서 운용되며, MPEG-1은 물론 MPEG-4 스트림을 지원함으로써 사용자 상호작용이 효율적이다. 또한, MPEG-7 스트림으로 확장될 수 있다. 이 연구의 결과는 QoS는 물론 전송과 재생 속도의 향상을 가져오므로 디지털 TV(DTV) 등에 활용될 수 있다.

  • PDF

내부표적체적 설정을 통한 방사선치료계획 평가 (Radiation Treatment Planning Evaluation by Internal Target Volume Settings)

  • 박호춘;한재복;최남길
    • 한국콘텐츠학회논문지
    • /
    • 제15권8호
    • /
    • pp.416-423
    • /
    • 2015
  • 본 연구에서는 내부표적체적을 통한 방사선치료계획을 분석하여 호흡연동방사선치료에 주로 이용되는 호기상태의 치료계획체적과 비교 분석하여 정상조직이 받은 선량을 알아보았다. 2013년 12월부터 2014년 6월까지 모 대학교병원 방사선종양학과에서 복부부위에 호흡연동방사선치료를 받은 환자 25명을 대상으로 하였으며, 암의 종류는 liver(64%), CBD(8%), gastric(8%), GB(8%), pancreas(8%), SMA(4%)이었다. ITV와 PTV 체적의 평균치는 $471.44cm^3$, $425.48cm^3$ 로 체적의 증가를 알 수 있었고, PTV구간에서 ITV구간으로 선택한 구간의 증가로 인해 정상조직체적 또한 증가함을 알 수 있었다. 그리고 정상조직체적의 증가, target volume 증가, 치료조사야 면적증가의 차이와 정상조직이 받은 선량평균치의 차이에서는 right kidney가 유의한 증가를 보였다. 호흡평균치에 따른 정상조직이 받은 선량평균치의 차이는 없었고 target moving과 정상조직의 선량평균치의 차이에서는 both kidney가 유의한 차이를 나타내었다. 결론적으로 PTV구간과 ITV구간 체적 설정을 통한 치료방법이 모두 정상조직의 보호선량에 적합하였으며, 처방선량의 95% 이상이 분포하였으므로 환자의 치료목적에 따라 선택적으로 사용되어도 무방할 것이라 사료된다.

토끼모델을 이용한 미니스크류 형상에 따른 토오크의 평가 - 원통형과 원추형 간의 비교 (The comparison of torque values in two types of miniscrews placed in rabbits: tapered and cylindrical shapes - Preliminary study)

  • 김경호;정주령;유현미;박동성;장인성;경승현
    • 대한치과교정학회지
    • /
    • 제41권4호
    • /
    • pp.280-287
    • /
    • 2011
  • Objective: This study compared the stability of cylindrical miniscrews (Cy, 7 mm in length) with that of tapered miniscrews (Ta, 5 mm in length), using torque values to determine if the healing time before loading affects the stability of the miniscrew and if the insertion torque is associated with the removal torque measured after a few weeks of healing. Methods: Ta and Cy with different thread lengths were placed in the tibias of 12 female New Zealand white rabbits (body weight: 3.0 - 3.5 kg), and the maximum insertion torque values (ITV) were measured. No orthodontic forces were applied so as to allow us to determine the pure effects of the different shapes. After 3 different healing periods (2, 4, and 6 weeks), maximum removal torque values (RTV) were measured immediately before the rabbits were sacrificed. Results: No miniscrews were loosened. There were no significant differences in ITV or RTV between the Ta and Cy nor were there any significant differences in the ITV and RTV between the 3 groups, which had different healing periods. There was a correlation between the ITV and RTV. Conclusions: Shorter Ta showed similar stability as Cy, as determined by torque values. This result strongly suggests that the tapered shape is more advantageous than the cylindrical shape. The RTV did not increase significantly over time. It is recommended that a miniscrew be loaded immediately; waiting a few weeks before loading should be avoided. The correlation between the ITV and RTV suggests that the ITV can be used to estimate a screw's future stability.

영상처리에 의한 차량속도 계측 시스템 구현 (Implementation of a Vehicle Speed Measurement System Using Image Processing)

  • 박형택;윤태원;황병원
    • 한국통신학회논문지
    • /
    • 제30권4C호
    • /
    • pp.276-282
    • /
    • 2005
  • 산업, 의용, 교통, 사회의 각 분야에서 응용되고 있는 산업용 텔레비전(Industrial Television : ITV)을 사용하여 동영상의 실시간 자동처리 방법에 의한 고속도로 및 일반도로상의 교통류 및 차량의 속도를 계측하는 시스템과 알고리즘을 개발하였다. 영상 계측 시스템에서는 ITV에 의한 실시간 처리를 가능하게 하기 위하여, 화면의 전화소를 처리하는 대신에 화면상에 미리 설정한 비교적 소수의 샘플점의 휘도 정보만을 취급하는 프레임 그레버를 사용하고, 그 시스템으로 각종 동영상의 처리 알고리즘을 개발하였다. 통과 차량의 대수의 계측은 시간적인 정보를 활용하는 것으로, 차량의 대략적인 윤곽을 그린 다음 그 윤곽의 선두 부분을 인식하는 기법에 의해서 1레인뿐만 아니라 많은 레인에 걸친 통과 차량을 계측할 수 있는 특징을 가지고 있다. 실제로, ITV 영상을 이용하여 고속도로 및 일반도로상에서 도로의 횡단 방향에 하나의 샘플열을 설치하고, 계측 알고리즘을 개발하였다. 또한 이 기법을 이용하여, 통과차량에 대하여 일정거리를 둔 2개의 샘플점 열을 설치하구 윤곽처리를 한 다음, 그 윤곽의 프레임수와 거리를 이용하여 차량의 속도를 계측하는 알고리즘을 개발하였다.