• Title/Summary/Keyword: ITS 기술표준

Search Result 671, Processing Time 0.033 seconds

Some Lessons Learned from Previous Studies in Cooperative Driving Automation (협력형 자율주행 기술 개발 동향과 시사점)

  • Jeon, Hyeonmyeong;Yang, Inchul;Kim, Hyoungsoo;Lee, Junhyung;Kim, Sun-Kyum;Jang, Jiyong;Kim, Jiyoon
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.21 no.4
    • /
    • pp.62-77
    • /
    • 2022
  • A cooperative driving automation system is imperative to overcome the limitation of the stand-alone automated driving technology. By definition, a cooperative driving automation system refers to a technology in which an automated vehicle cooperates with other vehicles or infrastructure to increase driving efficiency and safety. Specifically, in this study, the technical elements necessary for the cooperative driving automation technology and the technological research trends were investigated. Subsequently, implications for future cooperative driving automation technology development were drawn through the research trends. Finally, the importance of cooperative driving automation technology and infra-guidance service for automated vehicles were discussed.

Cu Blackening through CuO Oxidation for the Application of Camera Lens Spacers in Mobile Phones (휴대폰 카메라 렌즈 스페이서 적용을 위한 구리의 흑화)

  • Lee, Yeji;Kim, Yong Ha;Kim, Chang Hyun;Won, Yong Sun
    • Clean Technology
    • /
    • v.27 no.1
    • /
    • pp.17-23
    • /
    • 2021
  • Black polymer spacers are currently used for physically separating aligned camera lenses in camera modules of mobile phones. However, the mechanical properties of polymer spacers have their limits, especially in the current trend of using more lenses in thinner camera modules. Thus, copper (Cu) becomes a good candidate for those polymer spacers because of its superior mechanical properties and its inherent blackness due to its black surfaced oxides, such as copper (II) oxide (cupric oxide, CuO). The latter property is critical in quality control because the closer the color of a spacer is to black, the less light interference and flaring phenomena can occur. A standard Cu blackening process and its operational conditions were proposed in this study through a comprehensive analysis of previous research and patents. The Cu blackening process is composed of cleaning, deoxidizing, activating, blackening and sealing. The effects of operational parameters, such as the temperature of each unit process and the activator concentration, were then investigated by measuring the blackness of the Cu strips with a colorimeter. The proposed operational conditions were determined by whether the blackness of Cu strips was within the on-spec. value used in the field.

The Research Relating to QA of the Absorbed Dose in the 10 MeV E-beam Facility in Accordance with the International Standards (국제표준에 따른 10 MeV급 전자빔 조사시설의 흡수선량 품질보증에 관한 연구)

  • Ha, Tae-Sung;Ahn, Cheol;Jung, Pyeong-Hwan;Cho, Jeong-Hee;Lee, Jong-Seok;Lee, Hye-Nam;Yoo, Beong-Gyu
    • Journal of radiological science and technology
    • /
    • v.33 no.4
    • /
    • pp.387-394
    • /
    • 2010
  • In the field of healthcare, the conventional sterilization treatments have been replaced by irradiation methods which are in accordance with internationally well established quality standards. The quality control in radiation sterilization assures that the absorbed dose of the irradiated material is in agreement with its requirements and standards. The electron beam irradiation requires technical assessments of more process parameters than gamma irradiation does. Korea has witnessed wide uses of electron accelerators since early 2000 but there hasn't been research experiences relating to quality system in accordance with international standards. The new large scale e-beam irradiation system with the specification of 10 MeV, 8 kW was installed and operated in 2008 by Seoul Radiology Services Co. It consists of the electron accelerator, product handling system, safety, documentation and control subsystems into an integrated system to meet the requirement of the Good Manufacturing Practice such as process quality assurance and management of product tracking records. To implement the international standard such as EN ISO11137, it is necessary to understand the purposes aimed in the standard and carry out the tests following the procedures required. This study presented the specification of the e-beam facility and showed what its design requirements and features are. The test results on a variety of process parameters were presented and validated it they are within the required limits.

Interference Analysis for Deployment of the Efficient Village Broadcasting Radio System (마을방송 시스템의 효율적 구축을 위한 간섭분석)

  • Kang, Young-Heung
    • Journal of Advanced Navigation Technology
    • /
    • v.21 no.4
    • /
    • pp.359-364
    • /
    • 2017
  • Since the existing analog village broadcasting system has some technical problems in applying and degradations in performance due to its old equipments, it had been required recently to be changed to a wireless digital system and to develop the standardization. However, it is important to analyze the interference between villages in deploying the efficient digital wireless village broadcasting system. In this paper, simulations for co-channel and adjacent channel interference have been carried out considering digital private mobile radio(dPMR) and digital mobile radio(DMR) systems as a representative mobile radio. These results for frequency reuse and channel separation drawn from the separation distance between villages in co-channel interference and the frequency offset in adjacent interference can be helpful to establish a standard and the testing service in the near future.

Curriculum Development of Computer Engineering based on NCS (National Competency Standards) (국가직무능력표준을 활용한 컴퓨터공학 교과과정개발)

  • Kwon, Oh-Young;Jang, Kyung-Sik;Min, Jun-Ki
    • Journal of Practical Engineering Education
    • /
    • v.7 no.1
    • /
    • pp.67-76
    • /
    • 2015
  • National Competency Standard (NCS) is a national standard for competencies which are required of an employee to achieve his job successfully. For a university with four-year course, since there is no plan to redesign its subjects by applying NCS and some issues with regard to industrial aspects consistently incur, it should be verified that NCS can be applied to the curriculum of a university following the introduction to new National Qualification Test with the progress evaluation based on NCS. Thus, in this paper, we show the feasibility of applying NCS to the curriculum of a computer engineering department and present the redesign to curriculum using NCS.

Measurement and Analysis of Propagation for the Digital Radio Village Broadcasting System (디지털 마을방송 시스템 구축을 위한 전파 측정 및 분석)

  • Choi, Da-Som;Kang, Young-Heung
    • Journal of Advanced Navigation Technology
    • /
    • v.20 no.6
    • /
    • pp.568-573
    • /
    • 2016
  • Since the existing analog village broadcasting system has some technical problems in applying and degradations in performance due to its old equipments, it had been required to be changed to a digital system and to develop the standardization from now. Therefore, we have analyzed the service coverage in various environments in order to construct an effective digital wireless village broadcasting system. Also, a precise prediction of field strength should be set up in various propagation environments to design a digital radio stations with reliable transmit power. Using these results the received power and the propagation characteristics in various environments can be predicted to establish a standard and the testing service will be deployed in the near future.

Implementation and Verification of IMT-Advanced Simulator for 4G Evaluation (4G 기술 평가를 위한 IMT-Advanced 시뮬레이터 구현 및 검증)

  • Kim, Dae-Jung;Chung, Kwang-Sue
    • Journal of KIISE:Information Networking
    • /
    • v.37 no.6
    • /
    • pp.466-476
    • /
    • 2010
  • This paper proposes a novel simulator which is capable of loading different modules enabling to update the simulator easily when the 4G mobile communication technologies are revised. This simulator is not only designed based on IMT-Advanced channel model but also confirmed its reliability through mutual verification with Matlab based simulator developed by Winner+. The proposed simulator was evaluated on the basis of evaluation requirements on the IMT-Advanced. By comparing with experimental results for IEEE and 3GPP, it was also proved for the simulator to have a better performance.

Complex Bandpass Sampling Technique and Its Generalized Formulae for SDR System (SDR 시스템을 위한 Complex Bandpass Sampling 기법 및 일반화 공식의 유도)

  • Bae, Jung-Hwa;Ha, Won;Park, Jin-Woo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.7C
    • /
    • pp.687-695
    • /
    • 2005
  • A bandpass sampling technique, which is a method directly downconverting a bandpass signal to a baseband or a low IF signal without analog mixers, can be an alterative choice for the SDR system to minimize the RF front-end. In this paper, a complex bandpass sampling technique for two bandpass-filtered signals is proposed. We derived generalized formulae for the available sampling range, the signal's IF and the minimum sampling frequency taking into consideration the guard-bands for the multiple RE signals. Thru the simulation experiments, the advantages of the . complex bandpass sampling over the pre-reported real bandpass sampling are investigated for applications in the SDR design.

Invasive Brain Stimulation and Legal Regulation: with a special focus on Deep Brain Stimulation (침습적 뇌자극기술과 법적 규제 - 뇌심부자극술(Deep Brain Stimulation)을 중심으로 -)

  • Choi, Min-Young
    • The Korean Society of Law and Medicine
    • /
    • v.23 no.2
    • /
    • pp.119-139
    • /
    • 2022
  • Brain stimulation technology that administers electrical and magnetic stimulation to a brain has shown a significant level of possibility for treating a wide range of various neurological and psychiatric disorders. Depending on its nature, the technology is defined either as invasive or non-invasive, and deep brain stimulation (DBS) is one of the most well-known invasive brain stimulation technologies. Currently categorized as grade 4 medical device in accordance with Guideline On Medical Devices And Their Grades, a Notification of Ministry of Food and Drug Safety (MFDS), the DBS has been used as a stable treatment for several diseases. At the same time, the DBS technology has recently achieved substantial advancement, encouraging active discussions for its use from various perspectives. On the contrary, debates over legal regulation related to the use of DBS has relatively been smaller in numbers. In this context, this article aims to 1) introduce the DBS technology and its safety in setting out the tone; 2) touch upon major legal issues that would potentially rise from its use for four different purposes of treatment, clinical study, areas of non-standard treatment where no other methods are available, and enhancement; and finally 3) highlight disputes concerning common emerging issues observed in the aforementioned four purposes from the viewpoint of legal responsibility and liability of using the DBS, which are benefit-risk assessment, physicians' duty of information, patients' capacity to consent, control for device, and insurance coverage.

A Study on the Tendency of Dose value According to Dose calibrator Measurement Depth and Volume (Dose calibrator 측정 깊이와 용량의 변화에 따른 선량 값의 성향에 대한 고찰)

  • Kim, Jin Gu;Ham, Jun Cheol;Oh, Shin Hyun;Kang, Chun Koo;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.24 no.1
    • /
    • pp.20-26
    • /
    • 2020
  • Purpose It is intended to figure out the errors derived from changes in depth and volume when measuring the Standard source and 99mTc-pertechnetate by using a Dose calibrator. Then recommend appropriate measurement depth and volume. Materials and Methods As a Dose calibrator, CRC-15βeta and CRC-15R (Capintec, New Jersey, USA) was used, and the measurement sources were 57Co, 133Ba, 137Cs and 99mTc-pertechnetate was also adopted due to its high frequency of use. The Standard source was respectively measured the changes according to its depth without changing the volume, in a range of 0 cm to 15 cm from the bottom of the ion chamber. 99mTc-pertechnetate was measured at each depth by changing the volume with 0.1 mL, 0.3 mL, 0.5 mL, 0.7 mL and 0.9 mL Respectively. And the depth range was from 0 cm to 15 cm at the bottom of the ion chamber. Results In the case of Standard source 57Co, 133Ba, 137Cs and 99mTc-pertechnetate, there were significant differences according to the measurement depth(p<0.05). 99mTc-pertechnetate has a negative correlation coefficient according to the depth, and the error of the measured value was negligible at a depth from 0 cm to 7 cm at 0.3 mL and 0.5 mL, and the range of error increased as the volume increased. Conclusion In clinical practice, it is sometimes installed differently than the Standard depth recommended by the equipment company. If it's measured at the recommended depth and volume, it could be thought that unnecessary exposure of the operator and the patient will be reduced, and more accurate radiation exams will be possible in quantitative analysis.