• Title/Summary/Keyword: ITS장비

Search Result 1,253, Processing Time 0.035 seconds

Development of Ultrasound Phantom for Volume Calibration (부피 측정을 위한 초음파 팬텀 개발)

  • Kim, Hye-Young;Lee, Ji-Hae;Lee, Kyung-Ja;Suh, Hyun-Suk;Lee, Re-Na
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.227-230
    • /
    • 2008
  • The purpose of this study was to design and construct an ultrasound phantom for volume calibration and evaluate the volume measurement accuracy of a 2 dimensional ultrasonic system. Ultrasound phantom was designed, constructed and tested. The phantom consisted of a background material and a target. The background was made by mixing agarose gel with water. A target, made with an elastic material, was filled with water to vary its volume and shape and inserted into background material. To evaluate accuracy of a 2 dimensional ultrasonic system (128XP, ACUSON), three different shapes of targets (a sphere, 2 ellipsoids and a triangular prism) were constructed. In case of ellipsoid shape, two targets, one with same size length and width (ellipsoid 1) and another with the length 2 times longer than width (ellipsoid 2) were examined. The target volumes of each shape were varied from 94cc to 450cc and measurement accuracy was examined. The volume difference between the real and measured target of the sphere shape ranged between 6.7 and 11%. For the ellipsoid targets, the differences ranged from 9.2 to 10.5% with ellipsoid 1 and 25.7% with ellipsoid 2. The volume difference of the triangular prism target ranged between 20.8 and 35%. An easy and simple method of constructing an ultrasound phantom was introduced and it was possible to check the volume measurement accuracy of an ultrasound system.

  • PDF

A Study on the Efficiency Evaluation of Ultrasound Therapy Using Varicose Vein Simulated Tissue Phantom and Tissue Equivalent Phantom (하지정맥류 모사 생체조직 팬텀과 조직등가 팬텀을 이용한 초음파 치료효과 평가에 관한 연구)

  • Kim, Ju-Young;Jung, Tae-Woong;Shin, Kyoung-Won;Noh, Si-Cheol;Choi, Heung-Ho
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.3
    • /
    • pp.427-433
    • /
    • 2018
  • Because of the expectation of the non-invasive treatment effect, Various studies on the treatment of varicose veins using focused ultrasound are reported. In this study, the bio-tissue phantom and tissue equivalent phantom that can be applied to estimation of ultrasonic varicose veins treatment effect. Each phantom was evaluated for its usefulness by evaluating the acoustic characteristics and the shrinkage rate according to the ultrasonic irradiation. A multi-layer structure phantom with three layers of skin, fat, and muscle was constructed considering the structure of the tissue where the varicose veins occurred. The materials constituting each layer were made to have characteristics similar to human body. In addition, the multi-layered phantoms with blood vessel mimic tube, with bovine blood vessel, and with animal tissue were fabricated. The degree of shrinkage of blood vessel mimic material and vascular tissue according to ultrasonic irradiation was evaluated using B-mode image. As the results of this study, it was thought that the proposed phantom could be used effectively in the evaluation of ultrasonic varicose veins treatment. In addition, it is thought that these phantoms could be applied to the development of varicose vein treatment device using the focused ultrasound and the verification of the therapeutic effect.

Case Study on Bodyboard Design Development though User's needs (사용자 욕구조사를 통한 해양레저용품(Bodyboard)디자인 컨셉개발)

  • Kang, Bum-Kyu
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.5
    • /
    • pp.135-145
    • /
    • 2013
  • One of the words that describe unique features of human beings is "Homo Ludens (Playing Man)". As humans enjoy abundant and prosperous lives and the quality of life is further improved, play is increasingly becoming a central value of human life. As part of play, ocean leisure is getting popular these days, and in turn demands for ocean leisure-related products in Korea, most of which are dependent on foreign markets, are growing. Therefore, it is required that local companies are quick to turn their eyes on the fast developing market. This research aims to help develop a design concept for bodyboard, more suitable for the domestic market, by analyzing products and reflecting customers' needs. The findings of this study are as follows: first, it is desirable that the target of bodyboard in domestic market is young people aged between 14 and 29 and its price ranges from 40,000 to 100,000 won; second, a tube-type bodyboard is appropriate for beaches in Korea mostly with small and gentle waves, as also shown in a survey that over 65% of those surveyed prefer a tube-type bodyboard, and lastly, the CMFF (Color, Material, Form, and Function) strategy was newly developed in this study in order to create new concept bodyboards.

Factors Affecting the Minimum Detectable Activity of Radioactive Noble Gases (방사성 노블가스 측정을 위한 최소검출방사능 산출의 조절인자)

  • Park, Ji-young;Ko, Young Gun;Kim, Hyuncheol;Lim, Jong-Myoung;Lee, Wanno
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.16 no.3
    • /
    • pp.301-308
    • /
    • 2018
  • Anthropogenic radioactive noble gases formed by nuclear fission are significant indicators used to monitor the nuclear activity of neighboring countries. In particular, radioactive xenon, owing to its abundant generation and short half-life, can be used to detect nuclear testing, and radioactive krypton has been used as a tracer to monitor the reprocessing of nuclear fuels. Released radioactive noble gases are in the atmosphere at infinitesimal amounts due to their dilution in the air and their short half-life decay. Therefore, to obtain reliable and significant data when performing measurement of noble gases in the atmosphere, the minimum detectable activity (MDA) for noble gases should be defined as low as possible. In this study, the MDA values for radioactive xenon and krypton were theoretically obtained based on the BfS-IAR system by collecting both noble gases simultaneously. In addition, various MDA methods, confidence level and analysis conditions were suggested to reduce and optimize MDA with an assessment of the factors affecting MDA. The current investigation indicated that maximizing the pretreatment efficiency and performance maintenance of the counter were the most important aspects for Xe. In the case of Kr, since sample activities are much higher than those of Xe, it is possible to change the target MDA or to simplification of the analysis system.

Development of Conductive Polycaprolactone (PCL)-resin based on Reduced Graphene Oxide(rGO)/Polypyrrole (Ppy) composite for 3D-printing application (3D 프린팅 응용을 위한 환원그래핀/폴리피롤 복합체 기반의 전도성 폴리카프로락톤 레진의 개발)

  • Jeong, Hyeon Taek;Jung, Hwa Yong;Cho, Young Kwang;Kim, Chang Hyeon;Kim, Yong Ryeol
    • Journal of the Korean Applied Science and Technology
    • /
    • v.35 no.3
    • /
    • pp.935-939
    • /
    • 2018
  • 3D Printing technology is developing in various prototypes for medical treatment, food, fashion as well as machinery and equipment parts production. 3D printing technology is also able to fully be utilized to other industries in terms of developing its technology which has been reported in many field of areas. 3D printing technology is expected to be used in various applications related to $4^{th}$ industrial revolution such as finished products and parts even it is still carried out in the prototype model. In this study, we have investigated and developed conductive resin for 3d printing application based on reduced graphene oxide(rGO)/Polypyrrole(Ppy) composite and polycaprolactone(PCL) as a biodegradable polymer. The electrical properties and surface morphology of the conductive PCL resin based on therGO/Ppy composite were analyzed by 4point-probe and scanning electron microscope(SEM). The conductive PCL resin based on rGO/Ppy composite is expected to be applicable not only 3D printing, but also electronic materials in other industrial fields.

Development of an Electro Impedance Spectroscopy device for EDLC super capacitor characterization in a mass production line (EDLC 슈퍼 캐피시터 특성 분석을 위한 양산용 전기화학 분석 장치 개발)

  • Park, Chan-Hee;Lee, Hye-In;Kim, Sang-Jung;Lee, Jung-Ho;Kim, Sung-Jin;Lee, Hee-Gwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.12
    • /
    • pp.5647-5654
    • /
    • 2012
  • In this paper, we developed an electro impedance spectroscopy (EIS) device, which are primarily used for the analysis of fuel cells or batteries, to widen its coverage to the next generation super capacitor EDLC characterization. The developed system was composed of a signal generator that can generate various signal patterns, a potentiostatic generator, and a high speed digital filter for signal processing and measurement program. The developed system is portable, which is not only suitable laboratory use but also for mass production line. The special features of the system include a patterned output signal from 0.01 to 20 kHz, and a fast Fourier transform (FFT) analysis of current signals, both of which are acquired simultaneously. Our tests showed similar results after comparing the analysis from our newly-developed device showing the characteristics of EDLC complex impedance and the analysis from an equivalent impedance which was applied to an equivalent circuit. Now, we can expect a fast inspection time from the application of the present system to the super capacitor production line, based on time-varying changes in electrochemical impedance.

Comparison of the Real-time Measurements for PM2.5 and Quality Control Method (PM2.5 자동측정장비 비교 및 정도관리 방안)

  • Park, Mikyung;Park, Jin Su;Jo, Mira;Lee, Yong Hwan;Kim, Hyun Jae;Oh, Jun;Choi, Jin Soo;Ahn, Joon Young;Hong, You Deog
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.33 no.6
    • /
    • pp.616-625
    • /
    • 2017
  • Measurements using five real-time particle samplers were compared to measurements using three NRM (National Reference Method system) filter-based samplers(Gravimetric method) at Incheon, Korea, between May and August, 2014. The purpose of this study was to suggest the quality assurance/quality control (QA/QC) method of each instrument for use in a real-time continuous particle sampler to measure the mass of airborne particles with an aerodynamic diameter less than $2.5{\mu}m$ ($PM_{2.5}$). Five real-time particle samplers of BAM1020, FH62C_14, TEOM, PM-711 and SPM-613 were evaluated by comparing its measured 23 hr average $PM_{2.5}$ concentrations with those measured with NRM filter-based samplers simultaneously. The parameters(e.g. Inlet heating condition, Slope factor, Film response, Intercept, Background, Span value) of the real-time samplers were optimized respectively by conducting test performance evaluation during 7 days in field sampling. For example, inlet heating temperature of TEOM sampler controls $35{\sim}40^{\circ}C$ to minimize the fluctuation of the real-time measurement data and background value of BAM1020 is the key factor affecting the accuracy of $PM_{2.5}$ mass concentration. We classified the $PM_{2.5}$ concentration according to relative humidity (80%) to identify water absorbed in aerosols by measuring the ${\beta}$-ray samplers(BAM1020, FH62C_14) and TEOM. ${\beta}$-ray samplers were not strongly affected by relative humidity that the difference of the average $PM_{2.5}$ concentration was about 5%. On the other hand, The TEOM sampler overestimated $PM_{2.5}$ mass concentration about 15% at low relative humidity (<80%).

A Practical Quality Model for Evaluation of Mobile Services Based on Mobile Internet Device (모바일 인터넷 장비에 기반한 모바일 서비스 평가를 위한 실용적인 품질모델)

  • Oh, Sang-Hun;La, Hyun-Jung;Kim, Soo-Dong
    • Journal of KIISE:Software and Applications
    • /
    • v.37 no.5
    • /
    • pp.341-353
    • /
    • 2010
  • Mobile Internet Device (MID) allows users to flexibly use various forms of wireless internet such as Wi-Fi, GSM, CDMA, and 3G. Using such Internet, MID users can utilize application services. MID usage is expected to grow due to the benefits of portability, Internet accessibility, and other convenience. However, it has resource constraints such as limited CPU power, small memory size, limited battery life, and small screen size. Consequently, MIDs are not capable to hold large-sized complex applications and to process a large amount of data in memory. An effective solution to remedy these limitations is to develop cloud services for the required application functionality, to deploy them on the server side, and to let MID users access the services through internet. A major concern on running cloud services for MIDs is the potential problems with low Quality of Service (QoS) due to the characteristics of MIDs. Even measuring the QoS of such services is more technically challenging than conventional quality measurements. In this paper, we first identify the characteristics of MIDs and cloud services for MIDs. Based on these observations, we derive a number of quality attributes and their metrics for measuring QoS of mobile services. A case study of applying the proposed quality model is presented to show its effectiveness and applicability.

DEVELOPMENT OF NANO-FLUID MOVEMENT MEASURING DEVICE AND ITS APPLICATION TO HYDRODYNAMIC ANALYSIS OF DENTINAL FLUID (미세 물 흐름 측정장치의 개발과 상아세관액의 수력학에의 응용)

  • Lee, In-Bog;Kim, Min-Ho;Kim, Sun-Young;Chang, Ju-Hea;Cho, Byung-Hoon;Son, Ho-Hyun;Back, Seung-Ho
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.2
    • /
    • pp.141-147
    • /
    • 2008
  • This study was aimed to develop an instrument for real-time measurement of fluid conductance and to investigate the hydrodynamics of dentinal fluid. The instrument consisted of three parts; (1) a glass capillary and a photo sensor for detection of fluid movement, (2) a servo-motor, a lead screw and a ball nut for tracking of fluid movement, (3) a rotary encoder and software for data processing. To observe the blocking effect of dentinal fluid movement, oxalate gel and self-etch adhesive agent were used. BisBlock (Bisco) and Clearfil SE Bond (Kuraray) were applied to the occlusal dentin surface of extracted human teeth. Using this new device, the fluid movement was measured and compared between before and after each agent was applied. The instrument was able to measure dentinal fluid movement with a high resolution (0.196 nL) and the flow occurred with a rate of 0.84 to 15.2 nL/s before treatment. After BisBlock or Clearfil SE Bond was used, the fluid movement was decreased by 39.8 to 89.6%.

Initial Risk Assessment of Acetanilide with Respect to Human Health (아세트아닐리드의 초기 인체위해성 평가)

  • Lee, Su-Rae;Park, Seon-Ju;Lee, Mi-Kyung;Nam, U-Kyung;Chung, Sun-Hwa;Seog, Geum-Su;Park, Kwang-Sik;Kim, Kyun;Kim, Yong-Hwa
    • Environmental Analysis Health and Toxicology
    • /
    • v.15 no.1_2
    • /
    • pp.31-37
    • /
    • 2000
  • Acetanilide may be released into the environment through air and wastewater from its production and use sites and exposed to human. Acetanilide is known to produce an analgesic effect and may pose adverse effects on human health by overly exposure. According to the EUSES system, acetanilide showed a high MOS (Margin of safety) value exceeding 6$\times$10$^4$ on a regional exposure, which is safe enough for public health. Whereas the lowest MOS value in dermal exposure was estimated as 3$\times$10$^{-4}$ on a local basis (workplace), the risk could be partly counteracted by taking preventive measures such as using mask and globes and good ventilation in the work places. Acetanilide may pose a potential risk for workers by dust inhalation. For the sake of health protection in the work places, additional data should be accumulated with respect to repeated dose toxicity, reproduction toxicity and developmental toxicity, etc. It is, therefore, recommended that acetanilide should be a candidate for further work to supplement the lacking data until it is proved to be safe in the occupational health aspects.

  • PDF