• Title/Summary/Keyword: ITE type

Search Result 8, Processing Time 0.039 seconds

PCB layout for ITE digital hearing aids manufacture (귀속형 디지털 보청기 제작을 위한 PCB설계)

  • Jarng, Soon-Suck;Kim, Kyoung-Suck
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.577-579
    • /
    • 2004
  • Digital hearing aids enclose $6{\sim}8$ tiny components. Those electromechanical components are individually wired by soldering which is a manual labor and sometimes causes components' damage by heating. This paper suggests a PCB design for overcome these problems. Several PCBs are designed and manufactured and circuited to produce ITE(In The Ear) type hearing aids which are inserted in the ear canal. The most optimal size of the PCB design for the ITE hearing aid is presented in this paper.

  • PDF

PCB Layout for Digital Hearing Aids (디지털 보청기용 PCB 제작)

  • Jarng, Soon-Suck;Kim, Kyoung-Suck;Kwon, You-Jung
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1012-1015
    • /
    • 2004
  • Digital hearing aids enclose $6{\sim}8$ tiny components. Those electromechanical components are individually wired by soldering which is a manual labor and sometimes causes components' damage by heating. This paper suggests a PCB design for overcome these problems. Several PCBs are designed and manufactured and circuited to produce ITE(In-the-Ear) type hearing aids which are inserted in the ear canal. The most optimal size of the PCB design for the ITE hearing aid is presented in this paper.

  • PDF

ITE Hearing Aid Specification Testing Devise Development using Probe Microphones (프로브 마이크로폰을 사용한 귓속형 보청기 성능 검사장치 개발)

  • 장순석;권유정
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.1044-1047
    • /
    • 2003
  • An acoustic testing device composed of 2 probe microphones was developed for the electro-acoustic specification testing of the ITE (In-The-Ear) hearing aid (HA). The amplitude ratio and the phase difference between the incident pressure onto the HA microphone and the outward pressure of the HA receiver were measured by the present acoustic system. The microphones were particularly used because of small acoustic cavities where input and output pressures were present. The acoustic wall composed of clay completely blocks the propagation of the sound pressure between the small acoustic cavities. The system has an advantage of structural flexibility for the acoustic testing of different sizes and shapes of ITE-type HAs.

  • PDF

Design of Small Acoustic Filter for ITE Type Noise Protector (ITE 타입의 소음 차폐기용 소형 음향 필터의 설계)

  • Lee, Yun-Jung;Kim, Pil-Un;Chang, Yong-Min;Lee, Sang-Heun;Cho, Jin-Ho;Kim, Myoung-Nam
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.6
    • /
    • pp.479-487
    • /
    • 2004
  • The prevention of noise induced hearing loss is very important, because there is no treatment for it. There are some kinds of devices for hearing protection, and those are effective in preventing a noise induced hearing loss. However, people often resist the use of hearing protection devices because it is difficult to have a conversation. Therefore, a hearing protection device is must effective not only in hearing protection but also in preserving communication ability. In this paper, we proposed a small acoustic filter for ITE type noise protector to solving the problem about the difficulties of conversation. That is applied a principle of acoustic filters that have been used for a muffler of automobiles, guns, and etc. To find out the sound transmission characteristic at the eardrum, we regarded an acoustic filter and external ear canal as a coupled system. So, we simulated the coupled system with OrCad, and experimented with a designed acoustic filter and a 2 cc coupler which has the same transmission characteristic as the external ear canal has. We confirmed that it is possible to adjustment acoustic transmission characteristics through simulation of electrical model for acoustic filter and external ear and experiments using designed small acoustic filters.

PCB design for ITE digital hearing aids manufacture (귀속형 디지털 보청기 제작을 위한 PCB 설계)

  • Jarng Soon Suck;Kim Kyoung Suck
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • autumn
    • /
    • pp.235-238
    • /
    • 2004
  • 대부분의 보청기 이용자들은 자신이 장애를 겪고 있다는 사실이 알려지는 것을 꺼린다. 따라서 보청기 사용자들은 귀 바깥쪽으로 들어 나지 않는 귓속형(ITE type) 보청기를 선호한다. 하지만, 이러한 귓속형 보청기를 제작하는 것은 쉬운 일이 아니다. 보청기의 각각 부품들만을 볼 때는 그 크기가 소형이지만, 부품 모두를 귀속에 넣는다고 한다면, 공간의 확보는 꼭 필요한 사항이다. 또한 보청기는 하나의 칩(chip)에 부품이 전선(wire)을 통해 납땜이 되는 구조이다. 이는 전선의 단락을 유발할 뿐만 아니라 칩과 전선이 쉽게 떨어지며, 잦은 납Eoa 작업으로 인해 열적으로 칩의 파손까지도 일으킨다. 이를 보안하고자 여기에서는 보청기 소형화 방법으로 PCB(Printed Circuit Board)를 제시하였다. PCB 를 사용함으로써 전선의 사용을 최소화하고, 부품과 PCB 와의 직접적인 결합으로 인해 보다 견고한 보청기 제작을 목표로 하였다. 아울러 PCB 를 통한 부품의 실장으로 기존의 수작업이던 보청기 제작을 자동화와 제작 시간의 단축이라는 이점을 얻을 수 있다.

  • PDF

Design and Implementation of a Controllable White Noise Generator for Tinnitus Therapy (이명 치료를 위한 저절형 광역 소음발생개의 설계 및 구현)

  • Yi, Gyu-Dong;Lee, Jeong-Woo;Song, Byung-Seop;Lee, Sang-Heun;Cho, Jin-Ho;Kim, Myoung-Nam
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.1
    • /
    • pp.12-19
    • /
    • 2004
  • The tinnitus which is the one of the auditory disease is a phenomenon that the patients feel the sound in the ear or the head when there is no sound sources. There have been many therapies for this tinnitus so far, but it is known that the TRT (Tinnitus Retraining Therapy) is the most effective therapy. So we designed and developed the controllable white noise generator for TRT. It must be designed as small as possible for user's convenience, such as the ITE (In The Ear) type hearing aids. It used the thermal noise as the white noise source. And filter and tone control circuits are used at the end of the noise generation part to control the white noise characteristics. This link of the controllable circuits is used to change the white noise's characteristic for the various tinnitus patients' characteristic. we can confirm that the designed and implemented controllable white noise generator which is a ITE type operates properly by the experiments of filter and tone control circuit.

Chloroplast-type Ferredoxin Involved in Reactivation of Catechol 2,3-Dioxygenase from Pseudomonas sp.S-47

  • Park, Dong-Woo;Chae, Jong-Chan;Kim, Young-Soo;Iida, Toshiya;Kudo, Toshiaki;Kim, Chi-Kyung
    • BMB Reports
    • /
    • v.35 no.4
    • /
    • pp.432-436
    • /
    • 2002
  • Pseudomonas sp. S-47 is capable of degrading catechol and 4-chlorocatechol via the meta-cleavage pathway. XyITE products catalyze the dioxygenation of the aromatics. The sylT of the strain S-47 is located just upstream of the xylE gene. XylT of the strain S-47 is located just upstream of the xylE gene. XyIT is typical chloroplast-type ferredoxin, which is characterized by 4 cystein residues that are located at positions 41, 46, 49, and 81. The chloroplast-type ferredoxin of Pseudomonas sp. S-47 exhibited a 98% identity with that of P. putida mt-2(TOL plasmid) in the amino acid sequence, but only about a 40 to 60% identity with the corresponding enzymes from other organisms. We constructed two recombinant plasmids (pRES1 containing xylTE and pRES101 containing xylE without xylT) in order to examine the function of XyIT for the reactivation of the catechol 2,3-dioxygenase (XyIE) that is oxidized with hydrogen peroxide was recovered in the catechol 2,3-dioxygenase (C23O) activity about 4 mimutes after incubation, but the pRES101 showed no recovery. That means that the typical chloroplast-type ferredoxin (XyIT) of Pseudomonas sp. S-47 is involved in the reactivation of the oxidized C23O in the dioxygenolytic cleavage of aromatic compounds.

Custom-Made ITE Type Hearing Protection Device Using a Small Acoustic Filter

  • Lee, Yun-Jung;Kim, Pil-Un;Jung, Young-Jin;Chang, Yong-Min;Cho, Jin-Ho;Kim, Myoung-Nam
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.6
    • /
    • pp.376-383
    • /
    • 2006
  • Noise induced hearing loss (NIHS), the well-known occupational disease, is caused by continuous excessive noise. The prevention of NIHS is very important, because it is unrecoverable. There are some kinds of hearing protection device (HPD), and those are effective in preventing NIHS. But workers in noisy environment often resist to wearing them. Because they are ready - made products, so workers feel uncomfortable to wear. Also, they didn't maintain the conversation frequency range, so workers are hard to communicate in wearing them. To prevent hearing loss effectively, it is important that workers keep wearing HPD. Therefore, a HPD is needed to be comfortable to wear and be effective not only in hearing protection but also in preserving communication ability. So we proposed a custom - made hearing protection device in which a small acoustic filter is inserted. We designed several kinds of small acoustic filters and carried out some acoustic experiments for measuring characteristics of filters. We confirmed that acoustic transmission characteristic can be adjusted from experimental results using designed small acoustic filters. And we researched for the actual efficiency of a new developed custom - made hearing protection device using a small size acoustic filter. Also, we found out that workers are more satisfied with the new development than a former protection device from a workers' response.