• Title/Summary/Keyword: ISQ change

Search Result 14, Processing Time 0.022 seconds

Implant stability installed with CAD-CAM assisted flapless surgery : A pilot study (CAD-CAM assisted flapless 수술법으로 식립된 임플란트의 안정성 : 기초연구)

  • Park, Chan-Jin;Kim, Dae-Gon;Cho, Lee-Ra;Kashiwagi, Kosuke;Kawazoe, Takayoshi;Tanaka, Masahiro
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.4
    • /
    • pp.405-413
    • /
    • 2011
  • It was proposed that technologies derived from CAD-CAM and computed tomography may be useful for flapless implant treatment procedures. The aims of this study were to validate the reliability of this concept in a prospective 12-month clinical study. Twelve patients with fully edentulous areas in their mandibles were included in this study. A total of 71 implants were inserted in interforaminal regions by use of a CAD/CAM drill template($NobelGuide^{TM}$), specially designed for flapless implant surgery. To assess the degree of pain and discomfort, the patients were examined at 2 days and 1 week after surgery. Patient satisfaction and implant functionality were further evaluated at follow-up intervals of 1, 3, 6, and 12 months postoperatively. One implant failed early in 1 patient. All of the other implants were in a good functional state throughout the study. The mean marginal bone loss after 1 year of follow-up was 0.3 mm (SD, 0.1) at center, 0.5 mm (SD, 0.1) at canine and 0.7 mm (SD, 0.2) at distal fixtures, respectively. Statistically, there was not significant differences among each sites(P>.05)The mean ISQ change after 1 year of follow-up was -1.05 (SD, 2.76) at center, -0.85 (SD, 2.59) at canine and -1.27 (SD, 2.18) at distal fixtures, respectively. This prospective pilot study showed that the use of CAD/CAM technology and flapless implant surgery may be considered reliable for fully edentulous mandible of patients.

A Comparative Study on the Articles between 1982 ISC(Cargo) and 2009 ISC(Cargo) (1982 협회동맹파업약관(적하)와 2009 협회동맹파업약관(적하)의 비교 연구)

  • Kwon, O
    • International Commerce and Information Review
    • /
    • v.12 no.3
    • /
    • pp.335-359
    • /
    • 2010
  • The purpose of this study is to interpret the articles revision of the 2009 ISC(Cargo) compared to the 1982. The result of this study is summarized as followings: 1) the 'clause' attached to article in 1982 ISC(Cargo) was deleted in the revision of 2009 ISC(Cargo). 2) 2009 ISC(Cargo) is characterized as the marine insurance firms' acceptance of new environment change, limitation in causation and subject-matter insured, expansion of insurance period, and limited revision. 3) The assured has a large range of choice in 2009 ISC(Cargo) even though both 1982 ISqCargo) and 2009 ISC(Cargo) would be existed further. 4) There are few studies which have a focus on the impact of the relationship between responsibility of the insurer and opportunity of the assured on rate of premium. In the future, the studies on clauses, relationship among clauses, relationship between clause and rate of premium are needed in the 2009 ICC(Air), 2009 IWC(Air Cargo), 2009 ISC(Air Cargo), 2009 IWC(sending by post) et al.

  • PDF

Effect of rhPMP-2 coated implants on alveolar ridge augmentation in dogs (성견에서 골형성단백질이 코팅된 임플란트가 치조골 증대에 미치는 영향)

  • Park, Chan-Kyung;Kim, Jong-Eun;Shin, Ju-Hee;Ryu, Jae-Jun;Huh, Jung-Bo;Shin, Sang-Wan
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.3
    • /
    • pp.202-208
    • /
    • 2010
  • Purpose: This study was aimed to evaluate the effect of rhPMP-2 coated implants on alveolar ridge augmentation in dogs. Materials and methods: Six Beagle dogs were used in this study. Six 8.0 mm long anodized surface titanium implants were placed 5 mm into the mandibular alveolar ridge following 6 month of healing period after extraction. Each animal received three implants coated with rhBMP-2 and three uncoated control implants using the randomized split-mouth design. Radiographic examinations were undertaken immediately at implant placement (baseline), at weeks 4 and 8 after implant placement. The amount of bone augmentation was evaluated by measuring the distance from the uppermost point of the coverscrew to the marginal bone. Implant Stability Quotient (ISQ) values were measured immediately at implant placement and 8 weeks after implant placement. For the statistical analysis, Man-Whitney ranksum test and Wilcoxon signed rank test of SPSS 12.0 software were used (P=.05). Results: The BMP group exhibited radiographic vertical bone augmentation about $0.6{\pm}0.7$ mm at 8 weeks later while controls showed bone loss about $0.4{\pm}0.6$ mm. There was significant difference among the rhBMP-2 group and controls in bone level change (P<.05). The ISQ values were significantly higher in the BMP-2 group than the control group at 8 weeks later (P<.05), while there was no significant difference at surgery. Conclusion: Within the limitation of this study, the rhBMP-2 coated on anodized implant could stimulate vertical alveolar bone augmentation, which may increase implant stability significantly on completely healed alveolar ridge.

The effect of drill design on stability and efficacy of dental implants (치과용 임플란트의 안전성과 유효성에 대한 드릴 디자인의 효과)

  • Yoon, Ji-Hoon;Jeon, Gye-Rok;Yun, Mi-Jung;Huh, Jung-Bo;Jeong, Chang-Mo
    • The Journal of the Korean dental association
    • /
    • v.53 no.2
    • /
    • pp.132-142
    • /
    • 2015
  • Purpose : The objective of this research was to investigate an optimization of drill design factors for implant stability and efficacy through comparative evaluation by the cutting time, heat generation and initial stability. Materials and Methods : Three design factors were considered for the purpose of drill design optimization; the number of flute(2 flute, 3 flute), helix angle($15^{\circ}$, $25^{\circ}$) and drill tip shape(straight, 2-phase). Design factors were selected through comparative evaluation by temperature change, cutting time and ISQ value. Results : Heat generation and cutting time are influenced by all design factors(p<0.05). Drill tip shape was the only factors which influenced to the largest initial stability(p<0.05). Conclusion : Drills with 2 flutes, 2-phase formed drill tip, and 25 degrees of helix angle exhibit a better performance than other design.