The effect of drill design on stability and efficacy of dental implants |
Yoon, Ji-Hoon
(Department of Biomedical Engineering School of Medicine, Pusan National University)
Jeon, Gye-Rok (Department of Biomedical Engineering School of Medicine, Pusan National University) Yun, Mi-Jung (Department of Prosthodontics School of Dentistry Pusan National University) Huh, Jung-Bo (Department of Prosthodontics School of Dentistry Pusan National University) Jeong, Chang-Mo (Department of Prosthodontics School of Dentistry Pusan National University) |
1 | Romeo E, Lops D, Margutti E, Ghisolfi M, Chiapasco M, Vogel G. Long-term survival and success of oral implants in the treatment of full and partial arches: a 7-year prospective study with the ITI dental implant system. Int J Oral Maxillofac Implants 2004;19:247-59. |
2 | Han DH, Bae EK. Longitudinal clinical study on the efficacy of osseointegrated dental implants in partially edentulous Korean patients: an 8-years prospective study. J Korean Acad Prosthodont 2001;39(6):698-708. |
3 | Seo JY, Shim JS, Lee JH, Lee KW. Clinical and radiographical evaluation of implant-supported fixed partial prostheses. J Korean Acad Prosthodont 2006;44(4):394-404. |
4 | el Askary AS, Meffert RM, Griffin T. Why do dental implants fail? Part I. Implant Dent 1999;8:173-85. DOI |
5 | el Askary AS, Meffert RM, Griffin T. Why do dental implants fail? Part II. Implant Dent 1999;8:265-77. DOI |
6 | Kim YG. Risk Factor in Implant Dentisty. Well pub. 2006;191-218. |
7 | Albrektsson T, Branemark PI, Hansson HA, Lindstro J. Osseointegrated titanium implants. : Requirements for ensuring a long lasting, direct bone anchorage in man. Acta Orthop Scand Vol. 1981;52:155-170. DOI |
8 | Lundskog, J. Heat and bone tissue. An experimental investigation of the thermal properties of bone tissue and threshold levels for thermal injury. Scand J Plast Reconstr Surg. 1972;suppl 9:1-80. |
9 | Eriksson RA, Albrektsson T, Grane B, McQueen D. Thermal injury to bone. A vital microscopic description of heat effects. Int J Oral Surg 1982;1:115-121. |
10 | Eriksson RA, Albrektsson T. Temperature threshold levels for heat-induced bone tissue injury. A vital microscopic study in rabbit. J Prosthet Dent 1983;50:101-107. DOI |
11 | Eriksson RA, Albrektsson T. The effect of heat on bone regeneration: An experimental study in rabbit using the bone growth chamber. J Oral Maxillofac Surg 1984;42:705-711. DOI |
12 | Matthews LS, Hirsch C. Temperatures measured in human cortical bone when drilling. J Bone Joint Surg 1972;54:297-308. DOI |
13 | Eriksson RA, Adell R. Temperatures during drilling for the placement of implants using the osseointegration technique. J Oral Maxillofac Surg 1986;44:4-7. DOI |
14 | Watcher R, Stoll P. Increase of temperature during osteotomy. In vitro and in vivo investigations. Int J Oral Maxillofac Surg 1991;20:245-249. DOI |
15 | Cordioli G, Majzoub Z. Heat generation during implant site preparation: An in vitro study. Int J Oral Maxillofac Implants 1997;12:186-193. |
16 | ISO, ISO 14971:2007 Medical devices - Application of risk management for medical devices, ISO, 2007. |
17 | Yun JH, Jeon GR, Kim YJ, Jeong CM. Effect of simplified procedure of newly designed implant drill on the temperature changes and cutting time. J Korean Res Soc Dent Mater 2012;39(1):9-16. |
18 | Sener BC, Dergin G, Gursoy B, Kelesoglu E, Slih I. Effects of irrigation temperature on heat control in vitro at different drilling depths. Clinical Oral Implants Research 2009;20:294-298. DOI |
19 | Oh HJ, Wikesjo UM, Kang HS, Ku Y, Eom TG, Koo KT. Effect of implant drill characteristics on heat generation in osteotomy sites: a pilot study. Clinical Oral Implants Research 2011;22:722-726. DOI |
20 | Sharawy M, Misch CE, Weller N, Tehemar S. Heat generation during implant drilling: the significance of motor speed. J Oral Maxillofac Surg. 2002;60(10):1160-9. DOI |
21 | Fanuscu MI, Chang TL, Akca K, Effect if surgical techniques on primary implant stability and periimplant bone. J Oral Maxillofac Surg 2007;65:2487- 2491. DOI |