• Title/Summary/Keyword: ISO Regulation

Search Result 109, Processing Time 0.042 seconds

Study on the Electric Continuity Measurements of Green Car for Human Body Safety (친환경자동차의 인체 안전을 위한 전기적 연속성 측정 연구)

  • Kim, Hyang-Kon;Lee, Ki-Yeon;Kim, Dong-Ook;Choi, Hyo-Sang
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.3
    • /
    • pp.351-356
    • /
    • 2009
  • In this study, we analyzed and experimented about electric continuity for human body safety from green cars. And we compared power systems of HEV and examined about human body effect of current and time. We investigated internal and external standards and regulations for human body safety from high voltage electrical equipments. Indirect contact refers to contact between the human body and exposed conductive parts. According to UNECE R100, ISO 23273-3, ISO 6469-3 and Japanese Regulation Attachment 101, electric continuity between any two exposed conductive parts shall not exceed $0.1{\Omega}$. The value of electric continuity was measured below $0.1{\Omega}$ at the actual condition of green car. We expected that the results of these experiments can utilize to data for electrical safety of green car.

Analysis of Offensive Odorous Compounds Emitted From the Chemical Plants (화학공장에서 배출되는 악취규제물질의 분석 및 평가)

  • Choi, Jae-Sung;Kim, Jae-Woo
    • Journal of Environmental Science International
    • /
    • v.16 no.1
    • /
    • pp.33-38
    • /
    • 2007
  • The concentrations of offensive odorous compounds emitted from the two chemical plants in Chongju and Yeosu industrial complex in Korea were determined by uv/vis spectroscopy, gas chromatography, and high performance liquid chromatography. The odorous compounds examined in this study are ammonia, trimethyl amine, formaldehyde, acetaldehyde, propion aldehyde, butyl aldehyde, n-valeric aldehyde, iso-valeric aldehyde, hydrogen sulfide, methyl mercaptan, dimethyl sulfide and dimethyl disulfide. The concentrations of those were determined from the 10 sampling points of the two plants, respectively. The emission concentrations of all odorous com-pounds examined in the two plants were lower than those of the regulation standard levels of industrial complex in Korea, respectively. The propion aldehyde, n-valeric aldehyde, methyl mercaptan and dimethyl disulfide in Chongju and Yeosu plants, and butyl aldehyde and iso-valeric aldehyde in Yeosu plant were not detected at any sampling points examined.

Tool-Path Planning Algorithm for NURBS Surface Machining (NURBS 곡면가공을 위한 공구경로 계획 알고리즘)

  • 구태훈;지성철
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.154-157
    • /
    • 2003
  • This paper presents an efficient real-time tool-path planning method for interpolation of NURBS surfaces in CNC machining. The proposed tool-path planning method is based on an improved iso-scallop strategy and can provide better precision than the existing methods. The proposed method is designed such that tool-path planning is easily managed in realtime. It proposed a new algorithm, for regulation of a scallop height, which can efficiently generate tool-paths and can save machining time compared with the existing method. Through computer simulations, the performance of the proposed method is analyzed and compared with the existing method in terms of feedrate. total machining time and a degree of constraint on the scallop height.

  • PDF

Investigation on the Evaluation Method of Airborne Sound Insulation in Building and Building Elements (공기음 차단성능 평가방법의 고찰)

  • 양관섭;이태강;이근희;김선우
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.239-243
    • /
    • 2001
  • In evaluating sound performance of building, it is important to carry on tests and evaluations based upon residential sound performances. Korean Standards include test methods on sound performance, but don't include any code on evaluation methods. Therefore, evaluation methods from Japan or ISO have been used for evaluating sound performance in domestic so far. In this study, every regulation from ISO, JIS, ASTM, especially for airborne sound insulation against building and building element, is analyzed in order to apply to establishment of Korean Standards on a sound performance evaluation method in buildings.

  • PDF

Inhibitors of Inducible Nitric Oxide Synthase Expression from Artemisia iwayomogi

  • Ahn, Hanna;Kim, Ji-Yeon;Lee, Hwa-Jin;Kim, Yong-Kyun;Ryu, Jae-Ha
    • Archives of Pharmacal Research
    • /
    • v.26 no.4
    • /
    • pp.301-305
    • /
    • 2003
  • Nitric oxide (NO) is an important bioactive agent that mediates a wide variety of physiological and pathophysiological events. NO overproduction by inducible nitric oxide synthase (iNOS) results in severe hypotension and inflammation. This investigation is part of a study to discover new iNOS inhibitors from medicinal plants using a macrophage cell culture system. Two sesquiterpenes (1 and 2) were isolated from Artemisia iwayomogi (Compositae) and were found to inhibit NO synthesis ($IC_{50} 3.64 \mu g/mL and 2.81 \mu$g/mL, respectively) in lipopolysaccharide (LPS)-activated RAW 264.7 cells. Their structures were identified as 3-Ο-methyl-iso-secotanapartholide (1) and iso-secotanapartholide (2). Compounds 1 and 2 inhibited the LPS-induced expression of the iNOS enzyme in the RAW 264.7 cells. The inhibition of NO production via the down regulation of iNOS expression may substantially modulate the inflammatory responses.

Prediction of Whole Body Vibration for CE Operatorsusing the Vertical Human Body Model (수직 인체 모델을 이용한 건설 중장비 운전자의 전신진동 예측)

  • Ham, Jeonghoon;Kim, Sunghwan;Kang, Hyunseok;Park, Sangkyu
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2013.04a
    • /
    • pp.516-517
    • /
    • 2013
  • Whole body vibration is very important for operators in construction equipment (CE) industry. There is ISO 2631 regulation to protect operators of CE. Recently WBV is one of critical performance parameters of CE to give operators much better comfortable working environment. And there are many kinds of numerically simplified human body model for the motor industry. We applied one human body model in ISO 5982 for the CE development at early stage. And we've checked the validity of this model to consider WBV by the operator comfort point of view.

  • PDF

Investigation on the Laboratory Method of Measuring the Airborne Sound Insulation of a Suspended Ceiling (매단 천장의 실간 공기전달음 실험실 측정 방법 고찰)

  • 양관섭;이근희;김선우
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.1126-1131
    • /
    • 2002
  • Offices and other multipurpose buildings commonly have suspended ceilings installed over room dividing wall. But Korean Standards don't include any code on test methods and test facility of the suspended ceiling system. Therefore, test methods and test facility from ISO or ASTM have been used for evaluating sound performance in domestic so far. In this study, every regulation from ISO, ASTM, especially for airborne sound insulation against suspended ceiling system, is analyzed in order to apply to establishment of Korean Standards on test methods and test facility of suspended ceiling system and materials.

  • PDF

Uncertainty Analysis for Speed and Power Performance in Sea Trial using Monte Carlo Simulation (몬테카를로 시뮬레이션을 이용한 시운전 선속-동력 성능에 대한 불확실성 해석)

  • Seo, Dae-Won;Kim, Min-Su;Kim, Sang-Yeob
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.56 no.3
    • /
    • pp.242-250
    • /
    • 2019
  • The speed and power performance of a ship is not only a guarantee issue between the ship owner and the ship-yard, but also is related with the Energy Efficiency Design Index (EEDI) regulation. Recently, International Organization for Standardization (ISO) published the procedure of the measurement and assessment for ship speed and power at sea trial. The results of speed and power performance measured in actual sea condition must inevitably include various uncertainty factors. In this study, the influence for systematic error of shaft power measurement system was examined using the Monte Carlo simulation. It is found that the expanded uncertainty of speed and power performance is approximately ${\pm}1.2%$ at the 95% confidence level(k=2) and most of the uncertainty factor is attributed to shaft torque measurement system.

A Study on the Insulation Resistance Measurement Technique for Electrical Safety of Green Car (친환경자동차의 전기안전을 위한 절연저항 측정에 관한 연구)

  • Lee, Ki-Yeon;Kim, Dong-Ook;Kim, Hyang-Kon;Moon, Hyun-Wook
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.4
    • /
    • pp.597-601
    • /
    • 2009
  • Green car such as a hybrid electrical vehicle and fuel cell vehicle is developed as a commercial target. UN/ECE/WP29 is developing GTR of HFCV and establishing the regulation and standard of electrical safety by ELSA. The regulation and standard about Electrical safety of vehicle are prescribed in ISO, UN/ECE, FMVSS, Japanese Attachment and so on, in case of insulation resistance is referred to keep more than 100/Vdc, 500/Vac. However, accurate method to measure insulation resistance agreeable to structure of vehicle does not exist now, it is actually that correctness of measurement drops according to the feature of battery and fuel cell stack. In this paper, the method to measure insulation resistance for protection against electrical shock by direct contact or indirect contact in Green Car will be indicated by making a comparison between the insulation measurement in standard of electrical safety and the experiment results for HEV and HFCV.

A Test to Compare the Water Resistance Sun Protection Factor of General Water, Artificial Seawater, and Natural Seawater of Sunscreen (자외선 차단제의 일반 물, 인공 해수, 자연 해수의 내수성 차단지수를 비교하기 위한 시험)

  • Hyoung Hoon Hwang;Eun Young Kang;Su Yeong Kim;Hui Jeong Jung;Jun Seong Yang;Won Kyu Hong;Hong Suk Kim
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.49 no.4
    • /
    • pp.349-354
    • /
    • 2023
  • Sunscreen is a product that protects against ultraviolet rays by blocking and scattering ultraviolet rays, and has now become a daily necessity beyond cosmetics. Applying sunscreen is a common and easy way to prevent skin damage caused by ultraviolet rays. Due to its significance, the evaluation of sunscreen has evolved since its regulation by the FDA in 1978, progressing to standardized methods established by ISO. Additionally, to assess the loss of sunscreen due to activities such as water exposure or sweating, the Ministry of Food and Drug Safety in Korea and ISO have established protocols for evaluating the water-resistant sun protection factor (SPF). However, existing evaluations of water resistance have been mainly confined to test methods involving plain water, and methods accounting for the impact of seawater during activities like beach leisure, sports, and recreation are yet to be established. Based on the existing guidelines for testing the water-resistant UV protection index, this study compared the water-resistant UV protection index in water, artificial seawater (salt water) and natural seawater (sea water) to evaluate the UV protection index in real-world situations such as marine leisure, sports, and leisure activities. Through these results, we were able to compare the differences between water resistance sun protection index tests in ordinary water, artificial seawater, and natural seawater, and suggest a method for water resistance sun protection index tests using natural seawater.