• Title/Summary/Keyword: IS6110

Search Result 531, Processing Time 0.027 seconds

Pool Boiling Heat Transfer Coefficients Up to Critical Heat flux on Thermoexcel-E Enhanced Surface (Thermoexcel-E 촉진 표면에서 임계 열유속까지의 풀 비등 열전달계수)

  • Lee, Yo-Han;Kang, Dong-Gyu;Jang, Cheol-Han;Jung, Dong-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.9
    • /
    • pp.685-692
    • /
    • 2012
  • In this work, nucleate pool boiling heat transfer coefficients(HTCs) of 5 refrigerants of different vapor pressure are measured on horizontal Thermoexcel-E square surface of 9.53 mm length. Tested refrigerants are R32, R22, R134a, R152a and R245fa. HTCs are taken from 10 $kW/m^2$ to critical heat fluxes for all refrigerant at $7^{\circ}C$. Wall and fluid temperatures are measured directly by thermocouples located underneath the test surface and in the liquid pool. Test results show that critical heat fluxes(CHFs) of Thermoexcel-E enhanced surface are greatly improved as compared to that of a plain surface in all tested refrigerants. CHFs of all refrigerants on the Thermoexcel-E surface are increased up to 100% as compared to that of the plain surface. The improvement of Thermoexcel-E surface in CHF, however, is lower than that of the low fin surface. HTCs on Thermoexcel-E surface increase with heat flux. But after certain heat flux, HTCs began to decrease due to the difficulty in bubble removal caused by the inherent complex nature of this surface. Therefore, at heat fluxes close to the critical one, sudden decrease in HTCs needs to be considered in thermal design with Thermoexcel-E surface.

Study on a Shape Deformation of Water Meniscus for the Rectangular and Circular Tips Moving Horizontally (사각 및 원형 팁의 횡운동에 의한 물 메니스커스 형상변화에 관한 연구)

  • Kim, Sang-Sun;Son, Sung-Wan;Ha, Man-Yeong;Yoon, Hyun-Sik;Kim, Hyung-Rak
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.12
    • /
    • pp.843-851
    • /
    • 2011
  • A two-dimensional immiscible water meniscus deformation phenomena on a moving tip in a channel has been investigated by using lattice Boltzmann method involving two-phase model. We studied the behavior of a water meniscus between the tip and a solid surface. The contact angles of the tip and a solid surface considered are in the range from $10^{\circ}$ to $170^{\circ}$. The velocity of the tip used in the study are 0.01, 0.001, and 0.0001. The shapes of tip considered are rectangular and circular. The behavior of water confined between the tip and a solid surface depends on the contact angles of the tip and a solid surface, and the tip velocity. When the tip is moving, we can observe the various behaviors of shear deformation of a water meniscus. As time goes on, the behavior of a water meniscus can be classified into three different patterns which are separated from the tip or adhered to the tip or sticked to a solid surface according to the contact angles and the tip velocity.

Effect of Rear-Vortex of a Convergent-Divergent Duct on the Flow Acceleration Installed in a Vertical Structure (수직구조물 후방의 와류현상이 구조물에 설치된 벤투리관의 유체가속 효과에 미치는 영향에 관한 해석 연구)

  • Chung, Kwang-Seop;Kim, Chul-Ho;Cho, Hyun-Sung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.2
    • /
    • pp.94-100
    • /
    • 2013
  • A convergent-divergent nozzle or venturi nozzle has been used to accelerate the wind speed at its throat. The wind speed at the throat is inversely proportional to its area according to the continuity equation. In this numerical study, an airflow phenomena in the venturi system placed at a vertical structure was investigated to understand the vortex effect occurred at the rear-side of the vertical structure on the air speed increment at the throat of the venturi system. For this study, a venturi system sized by $20(m){\times}20(m){\times}6(m)$ was modelled and the area ratio(AR) of the model venturi was 2.86. To see the vortex effect on the air flow acceleration in the venturi throat, two different boundary conditions was defined From the study, it was found that the pressure coefficient(CP) of the venturi system with the vortex formed at the exit of the venturi was about 2.5times of the CP of the venturi system without the vortex effect. The velocity increment rate of the venturi system with the vortex was 61% but 9.5% only at the venturi system without the vortex. Conclusively, it can be said that the venturi system installed in a vertical structure has very positive effect on the flow acceleration at its throat due to the vortex formed at the rear-side of the vertical structure.

Prediction of Transport Properties for Transportation of Captured CO2. 1. Viscosity (수송조건 내 포집 이산화탄소의 전달물성 예측. 1.점성)

  • Lee, Won Jun;Yun, Rin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.4
    • /
    • pp.195-201
    • /
    • 2017
  • In this study, the viscosity of a $CO_2-gas$ mixture was investigated for the transportation of the captured $CO_2-gas$ in pipelines and for the designing of a thermal system, both of which involve the utilization of the $CO_2-gas$ mixture. The viscosities of the $CO_2-gas$ mixture, $CO_2+CH_4$, $CO_2+H_2S$, and $CO_2+N_2$ were predicted using three different models as follows : Chung, TRAPP, and REFPROP. The predictability values of the models were validated by comparing the estimated results with the experiment data for the $CO_2+CH_4$ and $CO_2+N_2$ under high-density conditions. The Chung model showed 2.41%, which is the lowest mean deviation of the prediction among the model. Based on the Chung model, the mixture mole fractions were changed from 0.9, 0.95, and 0.97, the mixture pressure was ranged from 80 bar to 120 bar by 10 bar, and the mixture temperature was varied from 310 K to 400 K by 10 K to observe the effects of the parameters on the mixture viscosity. Considering the high mole fraction of the $CO_2$ in the mixture, a significant variation of the mixture viscosity was observed close to the pseudo-critical temperature, and the viscosity for the $CO_2+H_2S$ mixture shows the highest values compared with those of the $CO_2+CH_4$ and $CO_2+N_2$.

Detection of Mycobacterium Tuberculosis in Bronchial Specimens Using a Polymerase Chain Reaction in Patients with Bronchial Anthracofibrosis (기관지 탄분 섬유화증 환자의 기관지내시경 검체에서 PCR을 이용한 결핵균의 검출)

  • Na, Joo-Ock;Lim, Chae-Man;Lee, Sang-Do;Koh, Youn-Suck;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong;Shim, Tae-Sun
    • Tuberculosis and Respiratory Diseases
    • /
    • v.53 no.2
    • /
    • pp.161-172
    • /
    • 2002
  • Background : To Investigate the association between bronchial anthracofibrosis (AF) and tuberculosis (TB), and the clinical utility of a polymerase chain reaction (PCR) on bronchial specimens for rapid diagno-sis of active pulmonary TB in patients with bronchial AF. Method : Thirty patients (25 women and 5 men ranging in age from 53 to 88), who were diagnosed with bronchial AF by a bronchoscopic exami-nation, were enrolled in this study. PCR targeting the IS6110 segment of Mycobacterium tuberculosis was performed on the bronchial wash fluid and anthracofibrotic bronchial tissue. The PCR results were compared with the bacteriological, histological, and clinical findings. Results : Eighteen of the 30 patients (60%) were associated with TB, nine of whom were confirmed as having active TB. The remaining 9 had a past history of TB. The sputum or bronchial aspirate AFB smear, culture, and histological findings were positive in 4 (13%), 9 (30%), and 5 (17%) patients, respectively. PCR of the AF tissue and bronchial wash fluid was positive in 5 (17%) and 11 (37%) of the 30 patients, respectively. PCR was more sensitive than the AFB smears for diagnosing pulmonary TB (22 % us 89 %, respectively, p<0.05). All 5 patients with positive AF tissue PCR results also had both histological findings and positive bronchial wash fluid PCR results. Of the 3 patients with positive PCR but negative bacteriological or histological results, 2 of these patients appeared to have active tuberculosis on a clinical basis. Conclusion: Although TB-PCR did not reveal an increased association between bronchial AF and TB compared with traditional methods, PCR on the bronchial wash fluid appears to be useful for the rapid diagnosis of pulmonary TB in patients with bronchial AF. TB-PCR on AF bronchial tissue itself did not yield additional benefits for diagnosing TB, which suggests that an AF lesion itself may not be an active or original site of the infection, but a secondary change of TB.

Development of the Aircap Module Attached to the Window Through Rolling (롤링을 통한 창호부착형 에어캡 모듈 개발)

  • Her, Ji Un;Seo, Jang Hoo;Kim, Yong Seong;Lee, Heang Woo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.11
    • /
    • pp.559-569
    • /
    • 2017
  • Various studies examining how to conserve building energy have been conducted recently. From such studies it has been determined that insulation performance of an aircap is viable and therefore aircaps are used as material for improving insulation performance of windows. However, the aircap for improving insulation performance of a window is attached on the front, causing infringement of the prospect right. Therefore, the purpose of this study is to develop an aircap module attached to the window through rolling, conducting performance verification throughfull-scale testbed and verifying its effectiveness. Findings of this study are as follow : 1) The module suggested in this study enables setting of an area wherein the aircap is attached through rolling so that the aircap rolls up using Velcro tape, and an insulation bar is suggested to block the gap between the aircap and window glass. 2) When the aircap is applied to the window, consumption of lighting energy increased during summer and winter by 2.8%~16.4% and 0%~76.2% respectively in comparison to no aircap application, indicating that it is unsuitable for conserving lighting energy. 3) In terms of conserving cooling and heating energy, an advantageous or effective aircap attachment method is the method whereby an aircap is attached to the front surface of a window. However, the method whereby an aircap is attached to a part of a window and where no aircap is attached increases consumption of cooling and heating energy during summer and winter by 6.0%~35.7% and 2.7%~41.6% respectively in comparison to the method wherein an aircap is attached to the front surface of a window. 4) In consideration of conserving cooling, heating and lighting energy, the attachment of an aircap to the front surface of window is the most appropriate method, and it is appropriate to attach the aircap at a position that is 1,500 mm or higher from the floor to secure the prospect right and minimize energy loss.

Energy Performance Evaluation of Low Energy Houses using Metering Data (실측데이터를 이용한 저에너지주택의 에너지성능평가)

  • Baek, Namchoon;Kim, Sungbum;Oh, Byungchil;Yoon, Jongho;Shin, Ucheul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.7
    • /
    • pp.369-374
    • /
    • 2015
  • This study analyzed analyzes the energy performance of six houses in Daejeon completed which were built in 2011. Observed The observed houses, which were all designed and constructed inof the same size and structure, are were highly insulated with triple Low-E coating windows; the insulation level of the walls is was $0.13W/m^2K$ and that of the roof is was $0.10W/m^2K$. As electric houses, all of the energy supplied to the houses, including for cooking, is was supplied by electricity. A and 3~4 kWp of photovoltaic system and a 3~5 kW of ground source heat pump (GSHP) were installed in each house tofor providing provide space heating/and cooling and hot water are installed. We constructed a Web-based remote monitoring system in order to understand energy consumption and the dynamic behavior of the energy system. T, and the results of our metering data analysis of 2013 are as follows. First, the annual residential energy consumption is was 4,400 kWh (${\sigma}=1,209$) and GSHP energy consumption is was 5,182 kWh (${\sigma}=1,164$). Second, residential energy consumption ranked highest in average energy usage, with at 45% of the total, followed by heating with at 30%, hot water supply with at 17% and cooling with at 6%. Third, the average energy independence rate is was 51.8%, the GFA (Gross gross floor area) criteria average energy consumption unit is was $48.7kWh/m^2yr$ (${\sigma}=10.1$), and the net energy consumption unit (except the energy yield of the PV systems) is was $24.7kWh/m^2yr$ (${\sigma}=8.8$).

Diagnosis of Tuberculous Cervical Lymphadenitis Using Polymerase Chain Reaction (경부 임파절에서 Polymerase Chain Reaction(PCR)을 이용한 결핵균의 진단에 관한 연구)

  • Kim, Ho-Joong;Hyun, In-Kyu;Lee, Myoung-Koo;Jung, Ki-Suck;Ahn, Hye-Kyung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.42 no.1
    • /
    • pp.35-41
    • /
    • 1995
  • Background: Tuberculous cervical lymphadenitis can be diagnosed by clinical findings, chest X-ray, Mantoux test, but confirmed only by excisional biopsy. The polymerase chain reaction(PCR) is now widely applied to test very small amount of pathogen and would be used to detect Mycobacterium tuberculosis in biopsied tissues and fine needle aspirates. Method: We carried out the PCR using IS-1 and IS-2 primers in 16 samples from tuberculous cervical lymphadenitis patients, and 13 samples from non-tuberculous cervical lymphadenopathy patients. Acid fast staining and culture for Mycobacterium were all negative. Results: All of 8 pathologically confirmed tuberculous cervical lymphadenitis samples showed positive PCR results, and of 5/8 clinically diagnosed samples were positive. None of 6 pathologically excluded samples were positive, and among 7 clinically undiagnosed samples 2 showed positive PCR results. Conclusion: In patients with suspected tuberculous cervical lymphadenitis, PCR could be used to detect Mycobacterium tuberculosis using biopsied tissues and even fine needle aspirates with good sensitivity and specificity.

  • PDF

Development of a Movable Drawer Type Light-Shelf with Adjustable Depth of the Reflector (반사판의 폭 조절이 가능한 서랍형 타입의 가동형 광선반 개발 연구)

  • Kim, Dasom;Lee, Haengwoo;Seo, Janghoo;Kim, Yongseong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.9
    • /
    • pp.343-349
    • /
    • 2016
  • Due to the recent increase in lighting energy consumption in buildings, there are a growing number of studies seeking solutions this problem. The effectiveness of light-shelves as natural lighting systems to solve this problem has been recognized, and various studies regarding such systems are being carried out currently. However, the lighting efficiency of light-shelves decreases if illumination intensity is low-such as at night time, and it also obstructs the views of building occupants. Therefore, the purpose of this study is to examine a movable drawer type light-shelf which allows for the width of the reflector to be adjusted and verify its performance through a simulated test-bed. The following conclusions were reached. 1) The purpose of this study is to solve the problem previously associated with the light-shelf system- of obstructed views-by responding to external environments and minimizing the width of the light-shelf at night time when the efficiency of the light-shelf declines. 2) The proper variables of the movable drawer type light-shelf which enables the width adjustment of the reflector were ascertained in this study according to four solar terms : a width of 0.6 m at an angle of $20^{\circ}$, a width of 0.4m with an angle of $20^{\circ}$, and a width of 0.1 m with an angle of $20^{\circ}$ were determined for the summer solstice, fall/spring equinoxes, and winter solstice respectively; revealing that width adjustment of the light-shelf is a significant factor. 3) The movable drawer type light-shelf which enables${\backslash}$width adjustment of the reflector suggested in this study can reduce the lighting energy consumption by 18.7% and 14.3% in comparison to previous light-shelves with a fixed width of 0.3 m and 0.6m, indicating that it is effective for saving energy.

Identification of Mycobacteria Using Polymerase Chain Reaction and Sputum Sample (객담을 이용한 Mycobacteria의 검출과 중합효소 연쇄반응의 민감성 비교)

  • Jang, Hyung Seok
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.47 no.2
    • /
    • pp.83-89
    • /
    • 2015
  • Although Mycobacterium tuberculosis complex strains remain responsible for the majority of diseases caused by mycobacterial infections worldwide, the increase in HIV (human immuno deficiency virus) infections has allowed for the emergence of other non-tuberculous mycobacteria as clinically significant pathogens. M. tuberculosis was detected by two-tube nested polymerase chain reaction (PCR) and non-tuberculous mycobacteria was detected by PCR-restriction fragment length polymorphism (RFLP) with Msp I. Result of niacin test is equal to result of two-tube nested PCR after culture for M. tuberculosis. In this study, acid fast bacilli stain (AFB. stain) >2+ case, Detection of Mycobacteria is similar to result before culture and after culture. AFB. stain <1+ case, result of mycobacteria is distinguished. Conclusionly, these results suggest that identification of mycobacteria must go side by side both culture and PCR for more fast and accuracy.