Browse > Article
http://dx.doi.org/10.6110/KJACR.2013.25.2.094

Effect of Rear-Vortex of a Convergent-Divergent Duct on the Flow Acceleration Installed in a Vertical Structure  

Chung, Kwang-Seop (School of Architecture, Seoul National University of Science and Technology)
Kim, Chul-Ho (Department of Mechanical and Automotive Engineering, Seoul National University of Science and Technology)
Cho, Hyun-Sung (NID Fusion Graduate School, Seoul National University of Science and Technology)
Publication Information
Korean Journal of Air-Conditioning and Refrigeration Engineering / v.25, no.2, 2013 , pp. 94-100 More about this Journal
Abstract
A convergent-divergent nozzle or venturi nozzle has been used to accelerate the wind speed at its throat. The wind speed at the throat is inversely proportional to its area according to the continuity equation. In this numerical study, an airflow phenomena in the venturi system placed at a vertical structure was investigated to understand the vortex effect occurred at the rear-side of the vertical structure on the air speed increment at the throat of the venturi system. For this study, a venturi system sized by $20(m){\times}20(m){\times}6(m)$ was modelled and the area ratio(AR) of the model venturi was 2.86. To see the vortex effect on the air flow acceleration in the venturi throat, two different boundary conditions was defined From the study, it was found that the pressure coefficient(CP) of the venturi system with the vortex formed at the exit of the venturi was about 2.5times of the CP of the venturi system without the vortex effect. The velocity increment rate of the venturi system with the vortex was 61% but 9.5% only at the venturi system without the vortex. Conclusively, it can be said that the venturi system installed in a vertical structure has very positive effect on the flow acceleration at its throat due to the vortex formed at the rear-side of the vertical structure.
Keywords
Venturi duct; Computational Fluid Dynamics; Vortex effect;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Douglas, J. F. et al., 2001, Fluid Mechanics, Prentice Hall, pp. 406-447.
2 PHOENICS PIL Manual, 2011, Version 2010, CHAM Ltd.
3 Cengel, Y. A. and Cimbala, J. M., 2009, Fluid Mechnaics Fundamentals and Applications, Mc- Graw-Hill International, 2nd edition, pp. 472-476.
4 Patankar, S. V., 1980, Numerical Heat Transfer and Fluid Flow, Hemisphere Publishing Corp.
5 Thompson, R. L., 1991, Body Fitted Coordinate, John Wiley and Sons, Inc.