• 제목/요약/키워드: IS6110

검색결과 531건 처리시간 0.028초

원형 CAV 댐퍼의 개발에 관한 연구 (A Study on the Development of a Circular CAV Damper)

  • 권영필
    • 설비공학논문집
    • /
    • 제25권11호
    • /
    • pp.612-616
    • /
    • 2013
  • A circular CAV damper has been developed, based on the investigation of the pressure loss, and the flow-resisting moment by the damper blade. When a torsional spring is attached to the damper axle, and the setting angle is adjusted to around $82^{\circ}$, the volume rate across the damper is almost independent of the static pressure. Such a CAV characteristic appears at an opening angle between $40^{\circ}$ and $60^{\circ}$, where the normalized moment decreases linearly with the angle. In addition, by adjusting the setting angle, the volume rate can be controlled to within 10% error, regardless of the pressure loss.

온실가스·에너지 절약보고서 작성방안에 관한 연구 (A Study on the Writing Methods for Greenhouse Gas and Energy Consumption Report)

  • 이제묘;도현수
    • 설비공학논문집
    • /
    • 제26권10호
    • /
    • pp.486-490
    • /
    • 2014
  • In our country, which imports 97% of the energy consumed, an energy saving policy is required. The price inflation of utility bills is caused by a steep rise in the prices of imported oil. This study aims to solve the difficulties that cause poor environmental conditions for workers in the energy services sector, and especially, to systematize energy consumption reports to manage energy goals by suggesting an example of written energy-saving reports. To this end, this research focuses on energy consumption of target facilities including office spaces in a main building and multi-use facilities of an office building. A system where all employees can participate is structured through the analysis of energy usage in the target buildings.

자동차용 블록식 온도감응 팽창밸브의 모델링 (Modelling of an Automotive Block Type Thermostatic Expansion Valve)

  • 원성필
    • 설비공학논문집
    • /
    • 제23권4호
    • /
    • pp.251-258
    • /
    • 2011
  • The objective of this study is to propose two empirical correlations to predict the mass flow rate through an automotive block type thermostatic expansion valve and then to evaluate the correlations. The first correlation is deduced by modifying the basic equation of the orifice meter for the mass flow rate and the second correlation is deduced by using the Buckingham's ${\pi}$ theorem. The first correlation showed very good agreement on the measured data for R134a, given by Monforte. Average relative deviation and standard deviation of it are 2.5% and 1.6%, respectively. The second correlation agreed on the same measured data with a little greater deviations. The two correlations may apply to common expansion valves which have different geometrical sizes of the same shape.

유로저항에따른 속도제어를 통한 Zone별 유량특성 연구 (A Study of Flow Characteristics through the Speed Control and Flow Resistance)

  • 오병길;김회서
    • 설비공학논문집
    • /
    • 제23권11호
    • /
    • pp.762-768
    • /
    • 2011
  • We use floor radiant heating system in the house of commons in winter Floor radiant heating system, which transfer heat by radiation, is one of the energy efficient and comfortable systems that. Floor radiant heating system is configured to be controlled by the room for energy-saving. Proper flow rate to a comfortable heating in the room is important. However, Using a constant speed circulation pump in separate rooms, heating system may cause an imbalance because of the difference of length of coil when operating in the rooms. In this study, our Research team examined heating imbalance due to the variation length through the coil length changes and flow control of the circulation pump.

암모니아-물 작동유체의 부분증발유동을 적용한 재생 랭킨사이클에 관한 연구 (Study on Regenerative Rankine Cycle with Partial-Boiling Flow Using Ammonia-Water Mixture as Working Fluid)

  • 김경훈
    • 설비공학논문집
    • /
    • 제23권3호
    • /
    • pp.223-230
    • /
    • 2011
  • The power cycle using ammonia-water mixture as a working fluid is a possible way to improve efficiency of the system of low-temperature source. In this work thermodynamic performance of the ammonia-water regenerative Rankine cycle with partial-boiling flow is analyzed for purpose of extracting maximum power from the source. Effects of the system parameters such as mass fraction of ammonia, turbine inlet pressure or ratio of partial-boiling flow on the system are parametrically investigated. Results show that the power output increases with the mass fraction of ammonia but has a maximum value with respect to the turbine inlet pressure, and is able to reach 22 kW per unit mass flow rate of source air at $180^{\circ}C$.

고분자 전해질 연료전지 가스확산층의 압축상태 평면 기체투과율 측정 (Measurement of In-plane Gas Permeability of Gas Diffusion Layers in Proton Exchange Membrane Fuel Cells under Compressive Strain)

  • 오창준;이용택
    • 설비공학논문집
    • /
    • 제28권9호
    • /
    • pp.367-372
    • /
    • 2016
  • Gas diffusion layer (GDL) of PEMFCs plays a role that it diffuses the reactant gases to the catalyst layer on the membrane and discharge water from the catalyst layer to the channel. Physical parameters related to the mass transport of GDL are mostly from the uncompressed GDLs while actual GDLs in the assembled stacks are compressed. In this study, the relation of compression and strain of GDLs with various Polytetrafluoroethylene (PTFE) loading is measured experimentally and In-plane gas permeability is measured at the condition that the GDLs are in compressive strain. The gas permeability decreased with the loading of PTFE and the presentation of gas permeability under compressive stain is expected to improve the accuracy of modeling work of mass transport in the GDL.

건축자재 내의 수분이 곰팡이 성장에 미치는 영향 (Influence of Moisture on Mold Growth in Building Materials)

  • 서장후
    • 설비공학논문집
    • /
    • 제24권12호
    • /
    • pp.852-857
    • /
    • 2012
  • Recently, the indoor air pollution by microbes such as fungi and mites have become a concern as important research topic on indoor air quality. Fungal growth is significantly affected by humidity. In this study, we examined the influence of relative humidity on the surface of building materials and the water content of building materials on the fungal growth rate by measuring the mycelium length of fungi in the fungal detector placed on the surface of building materials. As a result, even if the relative humidity on the surface of building materials is identical, the more water content of building materials is, the more fungi grow faster. It was suggested that fungal growth rate depends on not only the relative humidity on the surface of building materials but also the water content of building materials.

이온풍 공랭 방식 적용을 위한 방송용 LED 조명장치의 냉각 특성 해석 (Analysis of Cooling Characteristics of Broadcasting LED Light with Ion Wind Generator)

  • 박철우;이승준;김대중
    • 설비공학논문집
    • /
    • 제24권9호
    • /
    • pp.693-698
    • /
    • 2012
  • In the present work, numerical analyses of broadcasting LED light with ion wind generator have been carried out for enhancement of cooling performance. Ion wind generator is produced and experimented before analysis. With the use of result of experiments, broadcasting LED light model is computed. Ion wind velocity into LED light is varied with 0~3 m/s. Based on the numerical results, the area of duct-type ion wind generator was designed to reduce the volume flow rate of ion wind. The modified inlet geometry shows sufficient cooling capability. And, through modified ion wind generator, the volume flow rate of ion wind has been largely reduced.

배관계의 가스누설탐지를 위한 음향모델 연구 (A Study on an Acoustical Model for Gas Leak Detection in a Pipeline)

  • 양윤상;이동훈;고재필
    • 설비공학논문집
    • /
    • 제26권2호
    • /
    • pp.91-96
    • /
    • 2014
  • An acoustical model for detecting the leak location in a buried gas pipeline has been developed. This model is divided into an experimental model for sound diagnosis, and a theoretical model for sound prediction, which is based on the transfer matrix method, representing the sound pressure and the volume velocity as state variables. The power spectrum is measured by attaching only one microphone to the closed end pipe. It has been shown that the response magnitude of acoustic pressure signals calculated by the acoustical model depends upon the thickness and diameter of a pinhole. The validity for the acoustical model has been verified through a comparison between the measured and calculated results.

서울 및 부산지역의 가변 평형점온도에 따른 냉난방도일 산정법에 관한 연구 (Estimating Cooling and Heating Degree Days for Variable Base Temperature)

  • 임병찬;정순성;서동현
    • 설비공학논문집
    • /
    • 제26권2호
    • /
    • pp.79-85
    • /
    • 2014
  • In general, building energy performance is evaluated with a detailed transient building energy simulation program. However, energy evaluation tools with the bin method are still used, because of their simple and easy way to calculate building energy performance, without reducing their precision. In this research, several heating and cooling degree day methods are compared, and evaluated with their performance for variable base temperature. This analysis considered about ten years of the continuous outdoor temperature, in the Seoul and Busan areas. It is concluded that the simplified bin method is more or less acceptable for Seoul and Busan, compared with the detailed hourly bin method.