• Title/Summary/Keyword: IS-IS

Search Result 717,322, Processing Time 0.564 seconds

Effects of vitamin C as antioxidant on recovery of left ventricular function after ischemia and reperfusion in isolated rat heart (항산화제로서 비타민 C가 적출된 쥐심장에서 허혈 및 재관류후 좌심실 기능회복에 미치는 영향)

  • 류한영;이철주
    • Journal of Chest Surgery
    • /
    • v.29 no.6
    • /
    • pp.593-598
    • /
    • 1996
  • The large number of past investigation on extended myocardial protection clearly indicates that cold potassium cardioplegia and topical cooling have limited capabilities. Accordingly, more recent experimen- tal approaches have focused on the modalities of reperfusion and their implication on postischemic myo- cardial recovery. Oxygen may play a crucial role in the development of ischemic and reperfusion injury. Reactive oxygen radicals may be produced during ischemia or reperfusion after incomplete reduction of molecular oxygen or from other pathway and then induce fatal injury of the heart. The important obser- vation of oxygen-induced myocardial damage during reperfusion has led to the concept of applying oxy- gen free radical scavengers. So, this study is on dietary vitamin C supplementation as antioxidant in rats to determine whether or not they have a higher tolerance against cardiac ischemia-reperf'usion injury under Langendorff system. Male or female Sprague-Dawley rats (190-33Og) were randomly separated into two groups. Group A was not treated(n=10). Group B received vitamin C supplement (n=10). Experiment was performed 24 hours after vitamin C 200mg fed orally as injectable ascorbic acid. There were significant differences in contractile parameters between control and vitamin C-treated group. The RLVP (r te of post/preischemic left ventricular pressure) and Rdp/dt (rate of post/preischemic dp/dt) were significant statistically between two groups (p<0.05). But, RHR (rate of post/preischemic heart rate), time to first beat and sta'utilization were not significant. In conclusion, pretreatment with the antioxidant, ascorbic acid, was found to preserve left ventricular contractile function. But the precise mechanism of action of ascorbic acid has not as yet been determined, so further study will be required.

  • PDF

Intraoperative Measurement and Analysis of Coronary Artery Bypass Graft Flow (수술중 측정한 관상동맥 우회도관 혈류량의 분석)

  • Park, Kye-Hyun;Chae, Hurn;Yun, Yang-Ku;Lee, Jae-Woong;Kim, Kwhan-Mien;Jun, Tae-Gook;Kim, Jhin-Gook;Shim, Young-Mog;Park, Pyo-Won
    • Journal of Chest Surgery
    • /
    • v.30 no.8
    • /
    • pp.760-769
    • /
    • 1997
  • This study aimed to determine factors that influence blood flow through coronary bypass grafts and to analyze relationship between the graft flow and postoperative outcome. Blood flow through 146 bypass grafts(GBF) was measured with transit-time ultrasound flowmeter during coronary artery bypass grafting operations in 50 patients. Single and multiple regression analyses were done for relationships between the GBF and four variables: internal diameter of recipient coronary artery, myocardial value of bypassed branch(es), type of graft, and finding of preoperative myocardial perfusion scan. The relationship between GBF and postoperative scan finding was also analyzed. 1. The mean GBF was significantly higher in sequential grafts than in single vein grafts or in internal thoracic artery grafts(61.5 vs. 46.9 and 42.5 ml/min). 2. Myocardial value and recipient artery diameter were found to be the factors determining GBF. There was no correlation between GHF and presence of perfusion defect in the preoperative scan. 3. Myocardial value was found to be more important than recipient artery diameter in determinintg GBF. 4. Reversible perfusion defects were more frequently found in the areas upplied by grafts with low GBP. But this fact had only mild statistical significance. These results suggest that blood flow through a bypass graft is more determined by the size of its supplyinf: myocardium than by the size of recipient artery. So, we can expect effective improvement in myocardial flow reserve after grafting of small(1~1.5mm) coronary arteries, if they supply substantial area of myocardium.

  • PDF

Comparison of Outcomes According to the Hospitals of Antenatal Care in Very Low Birth Weight Infants (극소 저체중 출생아에서 산전 관리 기관에 따른 임상 경과 및 예후 비교)

  • Lee, Byoung-Kook;Lee, Heun-Ji;Min, Sung-Joo;Kim, Do-Hyun;Kim, Hee-Sup
    • Neonatal Medicine
    • /
    • v.16 no.2
    • /
    • pp.205-212
    • /
    • 2009
  • Purpose: The purpose of this study was to evaluate the differences according to the hospitals of antenatal care in premature infants. Methods: We retrospectively reviewed the medical records of premature infants with gestational ages <37 weeks and very low birth weights who were admitted immediately after birth to the neonatal intensive care unit (NICU) at the Dongguk University Ilsan Hospital between March 2007 and February 2009. The hospitals of antenatal care were divided into two levels (primary antenatal care hospital: hospitals with less than a level 2 NICU, secondary antenatal care hospital: hospitals with a level 3 NICU) based on the level of NICU in hospitals. In addition, total infants were divided into two groups (Immediate group: infants born within 24 hours of maternal admission, Delayed group: infants born after 24 hours of maternal admission). The differences between maternal and neonatal variables in each groups were studied. Results: Neonates in secondary antenatal care hospitals comprised 11.0% of the study neonates (10 of 91). We compared with two groups (primary antenatal care hospital and secondary antenatal care hospital), but there were no differences in all subjects. However, the 1 minute Apgar score ($\leq3$) was lower in the immediate group than the delayed group. Conclusion: Shorter duration of maternal admission to delivery was associated with a lower 1 minute Apgar score of neonates. These findings suggest that if maintenance of pregnancy is difficult when high-risk gravidas are transferred, clinicians must prepare for emergencies of neonates.

Obstetric and Neonatal Outcomes of the Teenage Pregnancy (청소년 임신에 따른 임산부와 신생아의 주산기 문제점)

  • Shin, Jeong-Hee;Bauer, Siegfried;Yoon, Young-Sun;Jeong, Hyun-Chul;Rhie, Young-Jun;Lee, Jang-Hoon;Woo, Chan-Wook;Choi, Byung-Min;Kim, Hai-Joong;Park, Sang-Hee;Song, Ji-Won
    • Neonatal Medicine
    • /
    • v.17 no.1
    • /
    • pp.94-101
    • /
    • 2010
  • Purpose:In recent years, Korea has showed a steady increase in the frequency of teenage birth, while the overall birth rate has declined. As the teenage birth is known as a high risk pregnancy itself, we examined perinatal complications of teenage mothers and whose neonates in aspects of medical problem, and social status and support. Methods:We examined the perinatal characteristics of teenage mothers and whose babies, who were hospitalized at Korea University Ansan Hospital from January 2004 to July 2009 using medical records retrospectively. Twenty-seven teenage mothers and their 28 babies were enrolled in this study. Results:Teenage mothers were all unmarried and showed high rates of preterm labor, maternal anemia, and unexpected delivery. Among them, 11 (40.7%) were from families that were separated. Eleven mothers (40.7%) did not have any antenatal care. There were high rates of prematurity and low birth weight (60.7% and 64.3%, respectively). The complication included: respiratory distress syndrome, patent ductus arteriosus and necrotizing enterocolitis. Fourteen babies (51.9%) were not going to be brought up by their biological parents. Conclusion:Teenage pregnancy had high rates of preterm labor and associated complications, often caused by the lack of proper antenatal care. Babies from unmarried mothers were likely to be adopted and this could be a social burden. Therefore, to reduce unplanned teenage pregnancy and births, sex education and social supports should be provided to all teenagers.

The Effect of Intravenous Contrast on SUV Value in $^{18}F$-FDG PET/CT using Diagnostic High Energy CT (진단용 고선량 CT를 이용한 $^{18}F$-FDG PET/CT 촬영시 정맥 조영제가 SUV 값에 미치는 영향)

  • Jeong, Young-Jin;Kang, Do-Young
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.3
    • /
    • pp.169-176
    • /
    • 2006
  • Purpose: According to the development of CT scanner in PET/CT system, the role of CT unit as a diagnostic tool has been more important. To improve the diagnostic ability of CT scanner, it is a key aspect that CT scanning has to be performed with high dose energy and intravenous (IV) contrast. So we investigated the effect of IV contrast media on the maximum SUV (maxSUV) of normal tissues and pathologic lesions using PET/CT scanner with high dose CT scanning. Materials & Methods: The study enrolled 13 patients who required PET/CT evaluation. At first, the patients were performed whole body non-contrast CT (NCCT-120 kVp, 130 mAs) scan. Then contrast enhanced CT (CECT) scan was performed immediately. Finally PET scan was followed. The PET omission data were reconstructed twice, once with the NCCT and again with the CECT. We measured the maxSUV of 10 different body regions that were considered as normal in ail patients. Also pathologic lesions were investigated. Results: There were not seen focal artifacts in PET images based on CT with IV contrast agent. Firstly, 130 normal regions in 13 patients were evaluated. The maxSUV was significantly different between two PET images (p<0.00)). The maxSUV was $1.1{\pm}0.5$ in PET images with CECT-corrected attenuation and $1.0{\pm}0.5$ in PET images with NCCI-corrected attenuation. The limit of agreement was $0.1{\pm}0.3$ in Bland-Altman analysis. Especially there were significant differences in 6 of 10 regions, apex and base of the right lung, ascending aorta, segment 6 & segment 8 of the liver and spleen (p<0.05). Secondly, 39 pathologic lesions were evaluated. The maxSUV was significantly different between two PET images (p<0.001). The maxSUV was $4.7{\pm}2.0$ in PET images with CECT-corrected attenuation and $4.4{\pm}2.0$ in PET images with NCCT-corrected attenuation. The limit of agreement was $0.4{\pm}0.8$ in Bland-Altman analysis. Conclusion: Although there were increases of maxSUVs in the PET images based on CT with IV contrast agent, it was very narrow in the range of limit of agreement. So there was no significant effect to clinical interpretation for PET images that were corrected attenuation with high dose CT using IV contrast.

Differential Diagnosis of Metastatic Bone Disease and Benign Bone Disease on Spine SPECT in Patients with Low Back Pain (요통 환자의 척추골 SPECT에서 골전이 병변과 양성골질환의 섭취 양상 분석을 통한 감별진단이 가능한가)

  • Lee, Seung-Hun;Choi, Yun-Young;Cho, Suk-Shin
    • The Korean Journal of Nuclear Medicine
    • /
    • v.35 no.6
    • /
    • pp.371-377
    • /
    • 2001
  • Purpose: One or more abnormal vertebrae detected on bone scintigraphy is a common finding in clinical practice, and it could pose a diagnostic dilemma especially in cancer patients. as either metastasis or benign disease may cause scintigraphic abnormality. The purpose of this study was to determine whether additional spine SPECT has a role in differentiating malignant from benign lesions in patients with back pain. Materials and Methods: We reviewed spine SPECT studios obtained over a three-year period in 108 patients. Among them, forty-five patients with abnormal SPECT and clinically followed records were evaluated (20 cancer patients were included). Uptake patterns were classified as follows: 1. Body: diffusely increased uptake, linear increased uptake of end plate, segmental increased uptake, and cold defect, 2. Posterior element: posterior to body (pedicle), posterior to Intervertebral disc space (facet joint), and spinous process. Lesions were correlated with radiological findings and with final diagnosis. Results: Sixty-nine bone lesions were detected on SFECT images, including 18 metastases, 28 degenerative diseases and 21 compression fractures. Cold defect (6) and segmental increased uptake (5) were dominant findings in metastasis; linear increased uptake (12), and facet joint uptake (15) were in degenerative change; and diffuse increased uptake (9), and linear increased uptake (9) were in compression fracture. Conclusion: Cold defect and segmental increased uptake of body were characteristic findings of metastasis, but care should be taken because compression fracture also shows segmental increased uptake in some cases. Degenerative disease was easily diagnosed because of the typical finding of linear increased uptake of end plate and facet joint. Therefore, additional bone SPECT after planar bone scan would be helpful for differentiating metastasis from benign condition in cancer patients.

  • PDF

Development of a Small Gamma Camera Using NaI(T1)-Position Sensitive Photomultiplier Tube for Breast Imaging (NaI (T1) 섬광결정과 위치민감형 광전자증배관을 이용한 유방암 진단용 소형 감마카메라 개발)

  • Kim, Jong-Ho;Choi, Yong;Kwon, Hong-Seong;Kim, Hee-Joung;Kim, Sang-Eun;Choe, Yearn-Seong;Lee, Kyung-Han;Kim, Moon-Hae;Joo, Koan-Sik;Kim, Byuug-Tae
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.4
    • /
    • pp.365-373
    • /
    • 1998
  • Purpose: The conventional gamma camera is not ideal for scintimammography because of its large detector size (${\sim}500mm$ in width) causing high cost and low image quality. We are developing a small gamma camera dedicated for breast imaging. Materials and Methods: The small gamma camera system consists of a NaI (T1) crystal ($60 mm{\times}60 mm{\times}6 mm$) coupled with a Hamamatsu R3941 Position Sensitive Photomultiplier Tube (PSPMT), a resister chain circuit, preamplifiers, nuclear instrument modules, an analog to digital converter and a personal computer for control and display. The PSPMT was read out using a standard resistive charge division which multiplexes the 34 cross wire anode channels into 4 signals ($X^+,\;X^-,\;Y^+,\;Y^-$). Those signals were individually amplified by four preamplifiers and then, shaped and amplified by amplifiers. The signals were discriminated ana digitized via triggering signal and used to localize the position of an event by applying the Anger logic. Results: The intrinsic sensitivity of the system was approximately 8,000 counts/sec/${\mu}Ci$. High quality flood and hole mask images were obtained. Breast phantom containing $2{\sim}7 mm$ diameter spheres was successfully imaged with a parallel hole collimator The image displayed accurate size and activity distribution over the imaging field of view Conclusion: We have succesfully developed a small gamma camera using NaI(T1)-PSPMT and nuclear Instrument modules. The small gamma camera developed in this study might improve the diagnostic accuracy of scintimammography by optimally imaging the breast.

  • PDF

Quantitative Measurement of Membrane $Na^+-K^+$ ATPase Activity using Thallium-201 : Comparison with Rubidium-86 (Thallium-201을 이용한 세포막 $Na^+-K^+$ ATPase 활성도 측정: Rubidium-86 측정법과의 비교)

  • Lee, Jae-Tae;Lee, In-Kyu;Sohn, Sang-Kyun;Lee, Kyu-Bo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.2
    • /
    • pp.121-128
    • /
    • 1998
  • Purpose: $Na^+-K^+$ ATPase activity has been estimated by the degree of inhibition of cation transport by cardiac glycosides (ouabain) using Rb-86 as a substrate. The biological characteristisc of T1-201 is known to be similar to those of potassium as a transport substrate in the presence of glucose, insulin or phobol myristate acetate (PMA). The purpose of this study was to measure ouabain sensitive $Na^+-K^+$ ATPase activity using T1-201 and compare with that using Rb-86. Materials and Methods: Smooth muscle cells isolated from rat aorta or human placental umbilical artery were cultured, and used to measure cellular $Na^+-K^+$ ATPase activity. $Na^+-K^+$ ATPase activity was measured as a percentage decrease in cellular uptake of T1-201 or Rb-86 by ouabain under the presence of glucose, insulin or PMA in media. Results: $Na^+-K^+$ ATPase activity measured with T1-201, as a transport substrate, was not different from those measured with Rb-86 in rat or human smooth muscle cell preparation. Incubation with high concentration glucose resulted in about 30% decrease in enzyme activity. In contrast, insulin or PMA resulted in 10-70% or 28% increases from baseline activity, respectively. Conclusion: These results suggests that 71-201 could replace Rb-86 in measurement of ouabain sensitive $Na^+-K^+$ ATPase activity in vitro. High level of glucose concentration decreased cellular $Na^+-K^+$ ATPase activity, but insulin or PMA increased it.

  • PDF

Biodistribution and Scintigraphy of Iodine-131-Iododeoxyadenosine in Rats Bearing Breast Cancer (흰쥐에서 Iodine-131-Iododeoxyadenosine의 생체분포 및 유방암 영상화에 관한 연구)

  • Kim, Seon-Gu;Kim, Chang-Guhn;Lee, Kang-Mo;Kim, Hye-Won;Min Byung-Cheol;Choi, See-Sung;Lee, Jong-Deuk;Yang, David J.;Kim, E. Edmund;Lee, Hyun-Chul;Won Jong-Jin
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.4
    • /
    • pp.374-381
    • /
    • 1998
  • Purpose: I-131 labeled (2'-deoxy-2'-iodo-${\beta}$-D-arabinofuranosyl) adenine (IAD) may be involved in DNA synthesis during active proliferation of tumor cells. We conducted this study to find out the biodistribution of IAD and it's feasibility for scintigraphic tumor imaging. Materials and Methods: Tosyl acetyl-adenosine was dissolved in acetonitrile, and I-131-NaI was added and heated to synthesize IAD. Female Fisher 344 rats innoculated with breast tumor cells were injected with 0.27 MBq of IAD. Rats were sacrificed at 0.5, 1, 2, 4, 24h and the % of injected dose per gram of tissue (%ID/g) was determined. For scintigraphy, rats bearing breast cancer were administered with 1.11 MBq of IAD and imaging was performed after 2 and 24h. Then, rat body was fixed and microtomized slice was placed on radiographic film for autoradiography. Results: %ID/g of tumor was 0.74 (0.5h),0.73 (1h), 0.55 (2h), 0.38 (4h), and 0.05 (24h), respectively. At 1h after injection, %ID/g of tumor was higher than that of heart (0.34), liver (0.42), spleen (0.47), kidney (0.69), muscle (0.14), bone (0.33) and intestine (0.51). However, %ID/g of tumor was lower than blood (1.06), lung (0.77), and thyroid (177.71). At 4h, %ID/g of tumor in comparison with other tissue did not change. Tumor contrast expressed by tumor to blood ratio was 0.69 and tumor to muscle ratio was 5.11 at 1h. However, these ratios did not improve through 24h. On autoradiogram and scintigraphy at 2 and 24 hour, the tumor was well visualized. Conclusion: This results suggest that IAD may have a potential for tumor scintigraphy. However, further work is needed to improve localization in tumor tissue.

  • PDF

Assessment of the Synovial Inflammation in Rheumatoid Arthritis with $^{99m}Tc$-labelled Polyclonal Human IgG(HIG): Prospective Comparison with Gadolinium Enhanced MRI ($^{99m}Tc$-labelled HIG 스캔을 이용한 류마티스 관절염 환자에서 활막염증의 평가 : 조영증강 자기공명영상과의 전향적인 비교)

  • Ryu, Young-Hoon;Lee, Jong-Doo;Suh, Jin-Suck;Park, Chang-Yun;Jeon, Pyoung;Na, Jae-Beom;Lee, Soo-Kon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.1
    • /
    • pp.84-91
    • /
    • 1995
  • Many clinical and laboratory tests have been employed to evaluate disease activity in rheumatioid arthritis. $^{99m}Tc$-labelled polyclonal IgG(HIG) has been demonstrated to accumulate in focal sites of infection or inflammation in both animals and human subjects. The purpose of this study was to distinguish arthritis with active inflammation from those without active inflammation and to correlate relative intensities of $^{99m}Tc$-labelled HIG uptake of the rheumatoid arthritis with clinical and MR indices of the joint inflammation. This study included twelve patients with active rheumatoid arthritis, two with ankylosing spondylitis and one with degenerative osteoarthritis without active inflammation. A Whole-body and spot images were obtained 4 hours after intravenous injection of 20mCi of $^{99m}Tc$-labelled HIG. Scintigrams were assessed visually by 3 experienced radiologists, and graded as normal or mildly and markedly increased uptake within the joints, and the degree of uptake was compared with clinical and radiologic severity of synovial inflammation. MRI studies were done on the involved joints consisted of wrist(n = 11), knee(n = 2) and hip joint(n= 2). Active synovitis was defined when marked elevation of ESR and gadolinium enhancement of synovium on MRI were demonstrated. Markedly increased radiotracer uptake was seen in 10 of 11 rheumatoid arthritic patients with active synovitis whereas normal or mildly increased uptakes were noted in others, including rheumatoid arthritic patient(n=1) and non-rheumatoid patients(n = 3) without active synovitis. This study showed that the localization of involved joints in rheumatoid arthritis could be detected with $^{99m}Tc$-labelled HIG and that the degree of uptake correlated well with the degree and activity of inflammation. In conclusion, $^{99m}Tc$-labelled HIG scan is a useful method in the evaluation of active inflammation in rheumatoid arthritis.

  • PDF